Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.1 LAccepted-AOC FLAT NO 101 UGF FRONT LHS RZ B 49A KAILASHPURI PALAM COLONY NEW DELHI 110045 | SOUTH WEST | DELHI | 110045 | L1 | Accepted-AOC Being L1 Bidder | |
| 2 | L2₹25.9 L+₹1.8 L (7.45%)Rejected-AOC B 87 SHAM NAGAR KHAYALA ROAD NEW DELHI 110018 | NEW DELHI | NEW DELHI | DELHI | 110018 | L2 | Rejected-AOC Not L1 Bidder | |
| 3 | L3₹26.0 L+₹1.9 L (7.86%)Rejected-AOC | L3 | Rejected-AOC Not L1 Bidder | |
| 4 | L4₹31.6 L+₹7.5 L (31.2%)Rejected-Finance A 303 VEENA CGHS LTD PLOT NO 5D SECTOR 22 DWARKA NEW DELHI 110077 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110077 | L4 | Rejected-Finance Non Bonafide | |
| 5 | L5₹34.3 L+₹10.2 L (42.4%)Rejected-AOC | L5 | Rejected-AOC Not L1 Bidder |
Tender Value
Refer Docs
EMD Value
₹95,400
Closing Date
12 Nov 2020, 6:00 pmClosed
GE U WATER SUPPLY DELHI CANTT10
GE U WATER SUPPLY DELHI CANTT10
OPERATION AND MAINT OF WATER SUPPLY INSTALLATION AT KABUL LINE SANYAT LINE TIGRIS ROAD AND SUMRAN LINE KARAM VIHAPUMP HOUSE INCLUDING REPAIR WORK IN THE AREA OF AGE U WATER SUPPLY NO II UNDER GE U WATER SUPPLY DELHI CANTT10
2020_MES_389059_1
GE/WS/D-115 of 2020-21
Open Tender
Civil Works
Item Rate
330 days
GE U WATER SUPPLY DELHI CANTT10
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE U WATER SUPPLY DELHI CANTT10
₹95,400
Yes
14 Dec 2020
22 Oct 2020
16 Nov 2020
22 Oct 2020
12 Nov 2020
5 Nov 2020
Amount
PART-I OPERATION AND MAINTENANCE OF E/M INSTALLATIONS
Operation & maintenance of Electric driven pump sets round the clock including Sunday and holidays in Three shifts per day of 08 hours each ( Ist shift from 0600 to 1400 hours,IInd shift from 1400 to 2200 hours and IIIrd shift from 2200 to 0600 hours) by deploying Experienced & qualified skilled One Pump operator in each shift at Kabul Line pump house complete including operation of valves for supply of water & periodical maintenance of Pump Sets such as gland packing, lubricants, cleaning properly to keep dust free all the time inclusive of daily, weekly , monthly and quarterly maintenance complete all as specified and as directed for the following pump sets :- (i) Centifugal pump set of capacity 50 HP -01 No (ii) Centifugal pump set of capacity 25 HP -01 No (iii) Centifugal pump set of capacity 70 HP -01 No (iv) Centifugal pump set of capacity 40 HP - 01 No (v) Submersible pump sets of 10 HP capacity -04 Nos (vi) Centifugal pump set of capacity 10 HP -01 No (vii) Non clogging monoblock pump set of 100 LPM, 1 HP - 01 No (viii) Operation and maintenance of chloronome plant - 01 No and Bleaching dozer - 01 No NOTE:- Quoted rate shall include the aspect mentioned in notes at srl no. 7 to 10.
Operation & maintenance of Electric driven pump sets round the clock including Sunday and holidays in Three shifts per day of 08 hours each ( Ist shift from 0600 to 1400 hours,IInd shift from 1400 to 2200 hours and IIIrd shift from 2200 to 0600 hours) by deploying Experienced & qualified skilled One Pump operator in each shift at Sanyat Line pump house complete including operation of valves for supply of water & periodical maintenance of Pump Sets such as gland packing, lubricants, cleaning properly to keep dust free all the time inclusive of daily, weekly , monthly and quarterly maintenance complete all as specified and as directed for the following pump sets :- (i) Centifugal pump set of capacity 40 HP -02 Nos (ii) Centifugal pump set of capacity 15 HP -02 Nos (iii) Submersible pump sets of 7.5/10 HP capacity -02 Nos (iv) Operation and maintenance of chloronome plant - 01 Nos and Bleaching dozer - 01 Nos NOTE:- Quoted rate shall include the aspect mentioned in notes at srl no. 7 to 10.
Operation and maintenance of electric driven pump set including its periodical maintenance round the clock including sunday and holiday in three shifts with one pump operator in each shifts of 8 hrs for operating the following capacity of pump set installed at Sumran Line (Karam Vihar) pump House including operation of valves for supply of water complete all as specified and directed by Engineer-in-charge and as detailed below :- (i) Centifugal pump set of capacity 30 HP -02 Nos (ii) Raw sewage submersible pump set 15 HP capacity - 02 Nos (iii) Submersible pump sets of 17.5/10 HP capacity -03 Nos (iv) Centifugal pump set of capacity 15 HP -01 No (v) Operation and maintenance of chloronome plant - 01 Nos and Bleaching dozer - 01 Nos (vi) Cleaning of strainer of sewage pit chamber by taking out the strainer, cleane thoroughly removing all waste and disposal particle and refixing (vii) Terrace pump up to 15.00 HP -14 Nos NOTE:- Quoted rate shall include the aspect mentioned in notes at srl no.7 to 10.
Operation and maintenance of electric driven pump set including its periodical maintenance round the clock including sunday and holiday in three shifts with one pump operator in each shifts of 8 hrs for operating the following capacity of pump set installed at Tigris road pump House including operation of valves for supply of water complete all as specified and directed by Engineer-in-charge and as detailed below :- (i) Centifugal pump set of capacity 25 HP -03 Nos (ii) Raw sewage submersible pump set 15 HP capacity - 02 Nos (iii) Submersible pump sets of 10 HP capacity -01 No (iv) Operation and maintenance of chloronome plant - 01 Nos and Bleaching dozer - 01 Nos (v) Cleaning of strainer of sewage pit chamber by taking out the strainer, cleane thoroughly removing all waste and disposal particle and refixing . (vi) Terrace pump up to 15.00 HP - 8 Nos NOTE:- Quoted rate shall include the aspect mentioned in notes at srl no.7 to 10.
Rates required to be quoted for executing the work as described in Srl.No. 2 to 5 here-in-before:-
Worker's wage per person as per existing rules
Employees Provident Fund as mentioned in the tender documents
Employees State Insurance Contribution as mentioned in the tender documents
Contribution of Bonus as mentioned in the tender documents
Over head & Profit on srl No 6.01 to 6.04
LWC as mentioned in the tender documents
Notes for Srl No. 2 to 5 :- The quoted rate against EPF, ESIC and Bonus shall be considered for payment on actual basis. Contribution towards EPF, ESIC and Bonus is payable only after submission of valid and authentic document in support of having paid the requisite amount to the workmen, ie proof of payment
Notes for Srl No. 2 to 5 :- The rates quoted by the contractor shall also deemed to be included for the following :- (i) Disinfection/ treatment of water by using chemicals as issued by department under Sch 'B' ,free for use, including operation and maintenance /repair/cleaning of Chlorine dozing pump and bleaching dozer including minor spares ie bleaching dozer, rubber bladder, PVC pipe heavy duty, nuts, bolts and washers etc all as directed. (ii) Operating connected accessories such as all type of sluice valve & connecting accessories. (iii) If any loss or damage takes place to the equipment, machinery, tools, stores, fitting and fixtures etc or any other equipment installed in the pump house premises during the contract period, the same shall be made good/borne by the contractor. (iv) General cleanliness and upkeeping existing plants and vegetation within the premises of the pump house/sump within the boundary wall by deploying additional manpower with T&P if required at any time and all as directed by Engineer-in-Charge
(iv) Mixing of Bleaching powder/Calcium based solid granular chemicals/ disinfectant Granules sodium dichloro Iso-Cyanurate chemicals/sodium Hypochloride including transportation of the same from MES store yard to installation is deemed to be included in the quoted unit rate of the items. (v) Bleaching powder/Calcium based solid granular chemicals/ disinfectant Granules sodium dichloro Iso-Cyanurate chemicals/ sodium Hypochloride shall be issued under sch 'B' free for mixing/pouring only and transportation of the same from MES store to installations shall deemed to be included in the unit rate of the items. (vi)Earth resistance of all the earthings shall be measured, twise a month and properly recorde in separate register as directed by Engr-in-Charge (vii) (a) The contractor shall keep the record of water testing and the same shall be signed by the contractor, Engineer -in- charge and medical representative. (b) Reading of all the water meter installed in the premises of installations shall be carried out twice a day & properly recorded in a seperate register as directed.
(viii) The contractor will submit the complete details of the tradesmen along with their qualification certificate before commencement of work. (ix) The contractor shall be responsible for watch and guard of installations round the clock 24 hours. Any loss or damage to the plant, equipment installed and Govt. property in the Pump house premises shall be made good/borne by the contractor. (x) The contractor shall be responsible for operation of terrace pump installed on terrace once in a week & shall be checked for serviceability(both voltage & amp) with tong tester & recorded in a separate register, failing which a panel recovery of Rs 2000/- per pump shall be made from his dues. (xi) If any new equipment/machinary installed during currency of the contract , the contractor shall run/operate the newly installed equipment without any extra cost.
PART-II REPAIR OF VARIOUS PUMP HOUSES UNDER AGE (U) W/S-II
Supply, installation and testing of flanged ends water meter ISI marked woltman type, Class 'B' of following sizes and making good connection with flanged ends, with gasket rubber sheet and nut & bolts fixing in horizontal/inclind/vertical position, including taking out unsv water meter complete all as specified and directed.. Note :- Flange joints including jointing materials shall deemed to be included in the unit rate of this item.
50 mm bore
80 mm bore
100 mm bore
Taking down the old unserviceable FASD (with MU relay) any size and supply and fixing new ML FASD (with MU relay) including stainless steel box of following starter and making good connection in existing LT panel complete all as specified and directed. Make : L&T
ML 1.5 FASD upto 25 HP relay max range 13-21 Amps
ML 3.0 FASD upto 50 HP relay max range 28-42 Amps
ML 4 FASD upto 75 HP relay max range 45-75 Amps
PART-III Sch of Credit to be quoted by Contractor
Old unsv water meter 50 mm
Old unsv water meter 80 mm
Old unsv water meter 100 mm
Old unsv ML 1.5 FASD starter
Old unsv ML 3.0 FASD starter
Old unsv ML 4 FASD starter
Notes for srl No. 14 to 15 :- Rate quoted in column 6 shall not be less than the estimated cost inserted by MES under column 5. In case bidder quotes rates less than the corresponding rate under column 5, the rate quoted shall be amended as per column 5 and total amount shall be amended accordingly.
somyaenterprises
M/S Satyam Associates
BRIJ MOHAN LAL AND CO.
SM CONSTRUCTION COMPANY
Vijay Electricals
Microsys Controls India
DHAIRYAE ENTERPRISES
Choice india
MAA SANTOSHI ENTERPRISES
AMIT ASSOCIATES
ONKAR ENGINEERS CONTRACTORS
Ridhi engineers and builders
ASHUTOSH BUILDERS
HIND CONSTRUCTIONS
New Era Engineers
V S BUILDER
stage.html
html • 0.09 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .