Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹3.5 L
EMD Value
₹7,070
Closing Date
6 Feb 2023, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer, MU.
Manipur University Canchipur, Imphal - 795005.
Construction of Type-II Qtr, Block-2 (2nd Floor), MU.
2023_MU_737551_1
No. 59/2022-23/ENGG/MU/Elect
Open Tender
Civil Works
Works
45 days
As Per Tender Document
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
The Registrar, Manipur University.
₹7,070
Canchipur MU.
7 Feb 2023
30 Jan 2023
7 Feb 2023
30 Jan 2023
6 Feb 2023
30 Jan 2023
2 Feb 2023
Amount
Sub-Head No. I (Wiring)
Wiring for Light point / Fan point / Exhaust Fan point / Call bell point with 1.5 mm2 PVC insulated Al. conductor single core cable in PVC casing & capping with piano type switch, suitable size PVC box and earthing the point with 1.5 mm2 PVC insulated Al conductor single core cable etc. as reqd.
1. Light Point - Group C
2. Fan Point - Group C
3. Exhaust fan Point - Group C
4. Calling Bell point - Group - C
Wiring for light point / Power Plug point with 2 x 4 mm2 PVC insutated Al. conductor single core cable in PVC casing & capping along with 1 no. 4 mm2 PVC insulated Al. conductor single core cable for loop earthing etc. as reqd.
Wiring for circuit / Sub - main wiring along with wire with ( the following size of ) PVC insulated Al. conductor single core cable in PVC cassing & capping etc. as reqd.
1. 2 x 1.5 mm2 + 1 x 1.5 mm2 earth wire
2. 2 x 2.5 mm2 + 1 x 2.5 mm2 earth wire
4. 2 x 6 mm2 + 1 x 6mm2 earth wire
Wiring for circuit / Sub - main wiring along with wire with ( the following size of ) PVC insulated Al. conductor single core cable in PVC cassing & capping etc. as reqd.
7.1. 2 x 16 mm2 + 1 x 16 mm2 earth wire
7.5 3 x 25 mm2 + 1 x 16 mm2 earth wire
Sub-Head No. II (Fitting & Switch Gear)
Providing and Fixings ( following capacity TP & N ) dis-connector fuse switch unit inside the existing cubical panel board with ISI marks HRC fuses including drilling holes in the cubical panel board, making connection as reqd.
3. 100 amp. TP & N
S/F Bus bar chamber with 4 strips bus bar of length 300 mm suitable for 100 amp capacity complete with all accessories i/c connection, earthing the body etc. as reqd.
Supply and fixing wall mounted metal board of welded contruction with minimum 35mm x 35mm x 6mm angle iron frame work with 25 mm x 6mm flate iron as intermediate members i/c painting etc. as reqd.
S/F ( following way), single/ double pole and neutral, sheet steel MCB distribution board, 240 V on surface / recessed complete with tinned copper bus bar neutral bus bar, earth bar, din bar, hinged front acrylic cover for the MCCB knobs detachable gland plate , interconnection, phosphatized and powder painted including earthing etc. as reqd. ( but without MCB / RCCB / Isolator)
S/F ( following rating) double pole 240 V isolator in the existing MCB DB complete with connection, testing and commissioning as reqd.
Supplying and fixing 5 amp to 32 amp rating 230 V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection, testing and commissioning etc. as reqd.
1. Single Pole
S/F 48 " sweep (1200 mm) A.C ceiling fan complete with down rod, canopy, 3 (three ) blades but without regulator etc. as reqd. ( Make Bajaj / Usha or similar )
S/F 305 mm sweep exhaust fan complete with all accessories i/c connection etc. as reqd.
S/F striplites batten type 4'- 1 x TLD 36/40W with electronic ballast strong steel body i/c connection etc. (TMC090 HF), philips
S/F 23 W CFL lamp
S/F brass batten/angle holder i/c connection etc as redq.
S/F call bell/buzzer suitable for DC/AC single phase 230 V complete as reqd.
S/F 3 pin 5 amp ceiling rose on the existing junction box / wooden block i/c connection etc. as reqd.
Supplying & Fixing stepped type electronic Fan Regulator on the existing modular plate switch box i/c connection but excluding modular plate etc. as reqd.
Supply & Fixing( following piano type switch / socket) on the existing switch box / cover i/c connection etc. as reqd.
1. 5 / 6 amps switch
3. 15/16 amp. Switch
4. 3 pin 5/6 amps socket outlet
6. 6 pin 15/16 amps socket outlet
Square PVC box 12mm to 32 mm ( 3 " x 3" )
Sub-Head No. III (Area Lighting)
Wiring for light point / Fan point / Exhaust Fan point / Call bell point with 1.5 mm2 FR PVC insutated copper conductor single core cable in surface / recessed PVC conduit with piano type switch phenolic laminated sheet suitable size MS-box and earthing the point with 1.5 mm2 FR PVC insulated copper conductor single core cable etc. as reqd.
2. Light point - Group C
Wiring for circuit / Sub- Main wiring along with earth wire with ( the following sizes of ) FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit etc. as reqd.
1. 2 x 2.5 mm2 + 1 x 2.5 mm2 earth wire
Providing and Fixings ( following capacity TP & N ) dis-connector fuse switch unit inside the existing cubical panel board with ISI marks HRC fuses including drilling holes in the cubical panel board, making connection as reqd.
1. 32 amp. TP & N
S/F Symmetric beam integral flood light luminaries HPSVT lamp up to 250 W grey powder coated die-cast Al. housing complete with all accessories i/c connection etc. ( Ref code no. BJEMFS - 250 SV WOB / 180377 ) ( BJOS 250 SV / MH )
Sub-Head No. IV (Earthing & Lighting Conductor)
Earthing with copper plate 600 mm x 600 mm x 6 mm thick i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) as reqd.
Extra for using salt and charcoal for G.I or copper plate earth electrode as reqd.
P/F 4 mm dia copper wire on surface or in recessed for loop earthing as reqd.
Providing and Fixing of lightning conductor finial made of 25 mm dia 300 long copper tube having single prong at top with 85 mm dia 3 mm thick copper plate i/c holes etc. complete as reqd.
Fixing of lightning conductor finial made of 25 mm dia 300 long copper / G.I tube having single prong at top with 85 mm dia 3 mm thick base plate i/c holes etc. complete as reqd.
Reveting, sweating and soldering lightning conductor tape reveting, sweating and soldering of copper / G.I tape ( with another copper / G.I tape base of the finial or any other metallic object as reqd.
Providing and fixing copper tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor as reqd. ( for horizontal run )
Providing and fixing copper tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor as reqd. ( for vertical run )
Providing, fixing and testing joint made of 20 mm x 3 m thick copper strip 125 mm long with 4 nos. of tinned brass bolt nuts, check and spring washer etc. complete as reqd.
S Ratankumar Singh
M/s KT Construction
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .