SE, EDC-II, Mathura
Near Kali Mata Mandir Cant, Mathura
Various 11 kv Line/Substations, DTR, PTR AUGMENTATION etc. works under business plan 2024-25 in the area of EDC II, Mathura on semi turnkey basis
2024_DVVNL_925918_4
06/EDC-II(M)/2024-25
Open Tender
Electrical Works
Turn-key
90 days
Mathura
Please see tender documents
2 documents required · 2 mandatory
₹5,900
Dvvnl, Agra
₹2.5 L
2 Aug 2024
28 Jun 2024
6 Jul 2024
28 Jun 2024
6 Jul 2024
28 Jun 2024
Amount
Supply of following material against various 11kv Lines/Sub-station, DTR, PTR augmentation etc. works as per RESPO Drawings/approved GTP/standard technical specifications
Stone Pad
Tee channel with clamp & B&N
Clamps for Tee Channel
"F" Bracket
Holding Clamp for (Cross Arm)
Complete Pole earthing by earth rod.
M.S. Angle Iron 75*75*8
Guarding Angle 75*75*8
Guarding Angle Clamp With NB
GI Wire 6swg
GI Wire 8swg
Danger Board With Clamp, N/B
Barbed Wire GI 6 swg
Number Plate 6*8 inches, painted with enemal paint, yellow base and black numbering
Top channel (125x65x2240mm)
Dropper Channel (100x50x2028mm)
MS Bracing Angle
Clamp for PCC with nut & Bolt
PG Clamp
Nut & Bolt with washer
Tee-off channeal with clamp & B&N
Stay Complete
3-Phase D.O. Fuse Set
Tail less unit complete with Structure for 63/100 KVA TF
M.S. Angle (75x75x6x2028mm) (T/F Base)
TF Clamp with Bolt nut
LT Shackle insulator
LT Clamp with Bolt nut
Eye Hook with Eye Bold AB Conductor
Piercing Connector
Distribution Box-3 Phase
Distribution Box Holding Clamp
Suspenstion Clamp
Copper L Piece 50*50*6 MM
3 Phase 11 kv DO Fuse Set Heavy Duty.
ACSR Insulated Weasal for jumpering
LT Protection Panel with 3 No. of Ckt by stud type tell less fuse unit compatable for installation of MCCB 1000 Amp.
All lugs 400 sqmm
Clamp angle for panel mounting support
L.T. XLPE Cable of size 3.5 x 240 Sqmm
L.T. XLPE Cable of size 3.5 x 150 Sqmm
L.T.XLPE Cable of size 3.5 x 120 Sqmm
Double Through Double Pole TPMO to be Mounted on Double Pole
LT Protection pannel with 03 No. of ckt by Stud type tell less fuse unit, Compatable for installtion of MCCB 400 Amp 4 pole
1x400 Sqmm LT PVC cable Single core
1x630 Sqmm LT PVC cable Single core
All Lugs 150 Sqmm
Supply, Heavy duty Connector (torque controlled shear bolted coppoer connector) (as per respo norms and of different sizes)
Fixing, erection and commissioning work of following material for various 11kv Line/Sub-station, DTR, PTR augmentation etc. works as per RESPO Drawings/Estimates. Work includes all cartage/carriage, T&P, and any other work which is required for completion of above said work as per satisfaction of supervisory engineer.
PCC Pole 8.5 Mtr. Long
ACSR Weasel Conductor
ACSR Rebbit Conductor
11 Kv Pin Insulator With Pins
11 Kv Polymer Disk Isulator 45 KN
11 kv VCB 600/300/5A, 350 MVA
11 kv VCB O/G 200/100/5A, 350 MVA
11 Kv XLPE Cable 3x300 sqmm
11 kv XLPE Cable 3x185 sqmm
11 kv out Door Jointing Kit 3*185 sqmm.
11 kv In Door Jointing Kit 3*185 sqmm.
T/F KVA 100 KVA Additional
T/F KVA 63 KVA Additional
T/F KVA 16 KVA Additional
ABC 3x95 Sq. mm cable
1x400 Sqmm LT PVC Cable Singel Core
Increasing Transformer 250 KVA (100 kva to 250 kva)
Increasing Transformer 100 KVA (63 kva to 100 kva) only commissioning and other related works are to be done, carriage of transformer is not to be done
Increasing Transformer 63 KVA (25 kva to 63 kva) only commissioning and other related works are to be done, carriage of transformer is not to be done
11KV XLPE CABLE SIZE 3*70
11/0.4KV 400KVA (COPPER wind) TF complete installation on trolly
11KV XLPE JOINTING KIT OUTDOOR 3*70
Double Through Double Pole TPMO to be Mounted on Double Pole
LT Protection pannel with 03 No. of ckt by Stud type tell less fuse unit, Compatable for installtion of MCCB 400 Amp 4 pole
1x400 Sqmm LT PVC cable Single core
All Lugs 150 Sqmm
Installation, Heavy duty Connector (torque controlled shear bolted connector)
Stone Pad
Tee channeal with clamp & B&N
Clamps for Tee Channel
"F" Bracket
Holding Clamp for (Cross Arm)
Complete Pole earthing by earth rod.
M.S. Angle Iron 75*75*8
Guarding Angle 75*75*8
Guarding Angle Clamp With NB
GI Wire 6swg
GI Wire 8swg
Danger Board With Clamp, N/B
Barbed Wire GI 6 swg
Number Plate 6*8 inches, painted with enemal paint, yellow base and black numbering
Top channel (125x65x2240mm)
Dropper Channel (100x50x2028mm)
MS Bracing Angle
Clamp for PCC with nut & Bolt
PG Clamp
Nut & Bolt with washer
Tee-off channeal with clamp & B&N
Stay Complete
3-Phase D.O. Fuse Set
Tail less unit complete with Structure for 63/100 KVA TF
M.S. Angle (75x75x6x2028mm) (T/F Base)
TF Clamp with Bolt nut
LT Shackle insulator
LT Clamp with Bolt nut
Eye Hook with Eye Bold AB Conductor
Piercing Connector
Distribution Box-3 Phase
Distribution Box Holding Clamp
Suspenstion Clamp
Copper L Piece 50*50*6 MM
3 Phase 11 kv DO Fuse Set Heavy Duty.
ACSR Insulated Weasal for jumpering
LT Protection Panel with 3 No. of Ckt by stud type tell less fuse unit compatable for installation of MCCB 1000 Amp.
All lugs 400 sqmm
Clamp angle for panel mounting support
L.T. XLPE Cable of size 3.5 x 240 Sqmm
L.T. XLPE Cable of size 3.5 x 150 Sqmm
L.T.XLPE Cable of size 3.5 x 120 Sqmm
GI Wire Chain Link Net for fencing Mesh D Fence Wire with foldable Gate height 1.52Mtr
LT Protection pannel with 03 No. of ckt by Stud type tell less fuse unit, Compatable for installtion of MCCB 400 Amp 4 pole
1x400 Sqmm LT PVC cable Single core
1x630 Sqmm LT PVC cable Single core
Al. Lugs 150 Sqmm
Supply, Heavy duty Connector (torque controlled shear bolted connector)
Completion of following work with all material, cartage/carriage, T&P, and any other required work for various 11kv Line/Sub-station, DTR, PTR augmentation etc. works as per RESPO Drawings/standard specifications/Estimates/as per satisfaction of supervisory engineer.
Stay Complete with Concreting
Concreting of Pole
Dismentling and safe carriage of Old ACSR Weasel Conductor to store centre Mathura/JE store
Dismentling and safe carriage of Old VCB to store centre Mathura/JE store
Welding of PCC Poles
Dismentling of old PCC Pole with accessories
Dismentling and safe carriage of old material to store centre Mathura/JE store
Water level Pipe Earthing of Panel's Neutral & TF Neutral & body
Chemical Earthing Panel body & fencing
Foundation of LT Protection Panel 30 cm Height
Painting of Fencing with red oxide & green paint
Painting of pole with red oxide, al paint & post office Paint
Interlocking of base in transformer area
Ganular sub base for laying of interlocking bricks
Toe wall for fencing
Reparing of Plinth if required
Miscellaneous Lug, Clamp, Washer, Nut, Etc.
T/F Plinth
T/F Fencing
T/F Earthing
GI Wire Chain Link Net for fencing Mesh D Fence Wire with foldable Gate height 1.52Mtr
Interlocking of base in transformer area
Toe Wall for Fencing
M/S Sushil Kumar
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .