Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹13.7 L
EMD Value
₹27,480
Closing Date
15 Dec 2025, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
DEVINDER KUMAR KAUSHIK
Electrical Rohtak
Prov. 200KVA T/F and street lights in Shopping Centre Sector-24, Panipat
2025_HBC_487722_1
20254EDBF52C ECB0 48F3 BF91 ABA92B507CF2247HSV
Open Tender
Electrical Works
Works
180 days
Panipat Panipat Panipat
2 documents required · 2 mandatory
₹500
₹27,480
Yes
17 Dec 2025
3 Dec 2025
16 Dec 2025
3 Dec 2025
15 Dec 2025
3 Dec 2025
[13.27]Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. [Through Rate]
[23.22.1.10]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.10. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 125 to 160 amp, 25 KA [Through Rate]
[23.22.5.2]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.2. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. Single Pole [Through Rate]
[23.6.6.4]MS CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.4. Supply and erection of MS conduit pipe 1.6 mm thick , ISI marked surface/recessed in slab/wall/ceiling etc. including cost of MS bends, inspection box and all other material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work. MS pipe of 40 mm dia. [Through Rate]
[24.1.1]EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required. [Through Rate]
[24.1.2]EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required. [Through Rate]
[24.1.8]EARTHING AND LIGHTENING ARRESTOR 8. Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material. [Through Rate]
[24.5.2.3]MISCELLANEOUS ITEMS 2.3. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 63/50 mm outer dia/inner dia [Through Rate]
Supply and erection of PCC pole as per IS: 1678-1960 specifications, 11Mtr. long 140mm x 200mm at top and 140mm x 400mm at bottom with working load of 400Kg buried 2.20M in ground or as per UHBVNL specification .
Supply and erection of 11 KV lighting arrestor as per relevant ISS specification
Supply and erection of 11 KV brown glazed 10 KN pin insulator with GI pin/ silicon type as per specification and approved make by DHBVN.
Supply and erection of fuse unit of L.T. side suitable for 200 KVA transformer complete with wooden board cleats, aluminum strips MS clamps and MS nut and bolts including all petty material required up-to the entire satisfaction of Engineer-in-Charge.
Supply and erection of ACSR conductor conforming to IS 398 (Part-II) 1976/1996, IS 4826-1976 IS 1521-1972 and IS 1778-1980 with latest amendments and erection of the same with accessories including stringing and sagging of conductor of various sizes i.e. 100mm2/80mm2/50mm2/30mm2/30mm2 PVC insulated as well as jointing and binding with insulator at supports in all respect up to the entire satisfaction of Engineer-in-Charge. 100sqmm ACSR
Supply and erection of L.T. Aerial bunched cable of size 120 Sqmm, 4 core plus 95 Sqmm including making of necessary connection of make Polycab, Havell’s Grandlay, complete in all respect up to the entire satisfaction of Engineer-in-charge
Supply, installation, testing, commissioning of 3 Phase 11KV/0.433 KV-250V, 200 KVA Oil immersed, naturally cooled, Aluminum Wound Outdoor type Distribution Transformers with CSP (Completely self protected) features with external micro-processor based four pole MCCB 300Amp. To 400 Amp, 50kA strictly conforming to Nigam’s technical specification No. CSC-V/R-I/DH/UH/P and D/2010-2011 read with amendment thereof and as per relevant ISS as amended from time to time and losses conforming to 4 stars rating of BEE as per Approved Specification of DHBVN/UHBVN including installation of transformer on existing platform up-to the entire satisfaction of Engineer-in-Charge. Voltage Rated Frequency Permitted at 75ºC i) Maximum load looses at 50% load at 75ºC = 780 Watt ii) Maximum losses at 100% load at 75ºC = 2300 Watt iii) Warranty = 78/72 Months shall be one time The above losses are maximum allowable and there would not be any positive tolerance.
Supply and erection of G.I. pipe bracket 1.0 mtr long made out of 32mm dia (B-class) Jindal, Hisar make, suitable for street light fitting including 2 nos. Clamps of M.S. Flat size 50x6mm, 6 nos. Nutt and Bolts of size 50x16mm with application of primer and painting complete in all respect up to the entire satisfaction of Engineer-in-Charge
Supply and erection of 11 KV G.O. switch suitable heavy duty with suitable copper male and female contents for 11 KV , G.I. pipe , nut and bolts complete as per ISS : 1816/1972 and ISS :2544/1963 with latest amendment thereof complete in all respect. New
Supply and erection of 63 Amps connection plate for incoming and outgoing cable in existing Panel/High Mast/Octagonal Pole etc. to be fitted with connector fixed on Bakelite sheet complete with nut and bolts.
S/E of 70/72 Watt LED street light luminaries with multiple LED with highly efficient high power LED light with lens, pressure die cast aluminum housing, reflector and enclosed with toughened glass/Polycarbonate, IP-66 level, having light efficacy 120 Lumens/watt up to the entire satisfaction of engineer-in-charge of work complete in all respect. Make:- Bajaj/Philips /LT (With 3 years free replacement warranty at site including labour charges free of cost). (Rate excluding GST)
Supply and erection of PVC insulated and sheathed underground cable, loose in existing pipe or trenches 1100 volts core having solid aluminium conductor wires confirming to IS: 694:2010, including making necessary connections complete in all respect up to entire satisfaction of the Engineer-in-Charge of the work. Cable Size: 25 Sqmm x 4-core (Armd.). Make: Grandlay/Polycab/Havell`s. (Without GST)
Supply and erection of PVC insulated 300 Sqmm single core un-armoured power cable with aluminum conductor 650/1100V confirming to ISS 1554(Part-I) of 1988 IS: 7098/Part-1/1988 with latest amendments with necessary connections and complete in all respect up-to the entire satisfaction of Engineer-in-Charge of the Work. Make: Grandlay/Polycab/Havell`s. (Excluding GST).
Supply and erection of PVC insulated and sheathed, 50Sqmm aluminum conductor cable, single core, 1100 volts grade in existing pipe, complete in all respect up to entire satisfaction of the Engineer-in-Charge of the work. Make: Grandlay/Polycab/Havell`s. (Excluding GST)
Supply and erection of 2.5 Sqmm x 3-core (Unarmd.) PVC insulated and sheathed Aluminium conductor service cable 1100 volts, having single solid aluminium conductor in each core as per IS:694, complete in all respect up to entire satisfaction of the Engineer-in-Charge of the work. Make: Polycab, Havell`s, Grandlay. (Excluding GST).
Only Labour charges for ON/OFF operation of all type of LED Light points including Removal of Fault of Circuits. Dismantlement and re-erection of LED fitting from poles for replacement or repairing of LED lights under Defect Liability Period. (2nd Year DLP)
Only Labour charges for ON/OFF operation of all type of LED Light points including Removal of Fault of Circuits. Dismantlement and re-erection of LED fitting from poles for replacement or repairing of LED lights under Defect Liability Period. (3rd Year DLP).
stage.html
html • 0.02 MB
cancelled_1.PDF
pdf • 0.58 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.98 MB
BOQ_565885.xls
BOQ • 0.37 MB
OT0124844.pdf
Other Document • 1.23 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .