Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.8 LAccepted-AOC PO PS RUPA DIST WEST KAMENG ARUNACHAL PRADESH PIN 790 003 | WEST KAMENG | ARUNACHAL PRADESH | 790003 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹25.7 L+₹1.5 L (6.35%)Rejected-Finance P O P S THRIZINO WEST KAMENG A P PIN 790 002 | WEST KAMENG | ARUNACHAL PRADESH | 790002 | L2 | Rejected-Finance HIGH BID VALUE | |
| 3 | L3₹26.6 L+₹2.4 L (9.95%)Rejected-Finance | L3 | Rejected-Finance HIGH BID VALUE |
Tender Value
₹24 L
EMD Value
₹48,000
Closing Date
6 Sept 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
COL SUNIL PILLAI
HQ CWE TENGA PIN-900194 C/o 99 APO
REPAIR /MAINTENANCE / SERVICING OF 11/ 0.433 KV TRANSFORMER, DEHYDRATION OF TRANSFORMER OIL AND CONNECTED ALLIED WORKS AT SUB STATION IN THE AOR OF AGE E/M UNDER GE 859 EWS
2023_MES_613007_1
8376/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE 859 EWS
E (b) (ii)
8 documents required · 8 mandatory
₹500
GE 859 EWS
₹48,000
Yes
23 Sept 2023
9 Aug 2023
13 Sept 2023
9 Aug 2023
6 Sept 2023
23 Aug 2023
Amount
M & L for carry out servicing of transformer indoor/outdoor type of capacity 63 KVA to 750 KVA with off load tapchanger 11/0.433 KV volts grade and carrying out preventive maintenance, technical inspection and testing of with a high skilled mechanic/specialist electric HT line complete as and when directed by Engr-in-Charge. Note :- (a) Checking of winding temperature & oil temperature. In case of unsatisfactory condition shut down the transformer and investigate if either is persistently higher than normal. (b) Checking of oil level and examine transformer for leaks. (If low top up with dry oil, which shall be measured & paid separately). (c) Checking of Dehydrating breather of silica gel (Replacement silica gel if required will be measured & paid separately) (d) Checking and cleaning of primary & secondary bushing from dirt and oil. (e) Checking of oil dielectric strength and presence of water moisture. (f) Checking, cleaning & testing of relays, alarm signal & contacts, fuses, circuits, their operation including change in setting, if necessary complete (g) Checking & testing of earth resistance. (h) Checking & testing of insulation resistance of windings (j) Checking of cable box. (k) Checking & tightening of bolts/nuts and other loose metallic parts. (l) Taking expert opinion in case of abnormal noise, abnormal temperature, electrical faults, alarm signal through Buchholz Relay etc.(l) Checking leakges from entire transformer and replacement of packing cork sheet with new one (m) All testing tools, equipments and other T & P required for technical inspection, T&P required for replacement of packing shall be provided by the contractor & cost also included in quoted rate.
M&L for spray painting of transformers located at various locations in AOR of AGE E/M with two coats of synthetic enamel paint first quality of approved colour/shade after preparation of old painted surface to entire satisfaction of Engr-in-charge for the capacity of transformer from 63 KVA to 200 KVA complete all as specified and as directed. Note :- The work will be carried at different locations in cantt area. Neceaary transport arrangement for shifting machine from one place to another to be arranged by contractor and cost of same to be included in unit rate.
All as per srl item No 2.00 here in before but for the capacity of transformer 250 to 750 KVA capacity
M & L for filtration/dehydration of transformer oil to the existing transformers of various capacities installed at various electric sub station/ pump houses indoor/outdoor type, pole mounted / plith mounted at AOR of AGE E/M in situ till achieve dielectric strength min 40 KV all as specified and directed.
M & L for topping up/replacement of transformer oil with new transformer oil suitable for working voltage 11000 volts grade including necessary dehydration to achieve dielectric strength min 40 KV at 4mm gap complete all as specified and directed. Make – Power / GULF/Castrol/ HP /IOC /Savita .
M & L for replacement of silicagel grains in the breather assembly of transformer complete all as specified and directed.
M&L for openning of top cover in situ or at wksp by unscrewing all nuts, bolts & washers, daining out transformer oil upto required level and keeping in clean container for replacement of HT/LT bushings, for lifting of core assy, for cleanning/repair and refixing complete with new cork sheet gusket, existing/new nuts, bolts & washers for transformer indoor/outdoor type, refilling of oil all as specified and directed. (Note:- HT/LT bushings, Studs, Nuts, bolts & washers required new mesured here-in-after as separate item.) for transformer capacity upto 63 KVA to 750 KVA, 11/0.433 KV volts grade
M&L for replacement of transformer porcelain bushing outdoor/indoor type in situ/wksp suitable for 11 KV grade complete with brass stud, rubber bush, washers, nuts, checknuts and cork sheet gasket for the rating of 63 KVA to 750 KVA, 11/0.433 KV transformer complete all as specified and directed. Note:(a) Opening of top cover measured separately
M&L for replacement of transformer LT porcelain bushing indoor/outdoor type in situ/wksp suitable for 1100 volts grade complete with rubber bush, washers, nuts, checknuts and cork sheet gasket for the rating of 63-200 KVA, 11/0.433 KV transformer complete all as specified and directed. Note:(a) Opening of top cover measured separately. (b) Brass stud measured separately
All as per item No. 9.00 here-in-before but for transformer capacity 250-750 KVA,
M&L for replacement of brass stud suitable for LT 1100 volts grade with con & rubber washer, double Brass nuts & brass washer at both end of stud for Tr cap 63-200 KVA
All as per item Ser No. 11.00 here-in-before but for transformer capacity 250-750 KVA
M&L for transportation of unserviceable transformer of capacity from 63 KVA to 750 KVA (with vehicle and using hydra crane as per site requirement for loading/unloading) to workshop at Tezpur and return back for installation it on original position/location after repairing from workshop (Rate is deemed to be inclusive of transportation, T&P and man power). Note :- The work will be carried at different locations in AOR of AGE E/M. Neceaary transport arrangement for shifting machine from one place to another to be arranged by contractor and cost of same to be included in unit rate.
M & L for lifting up carefully transformer core after dismentling carefully terminal connections from core to HT/LT bushings, tap changer assy, drainout all oil and keeping in clean container, dismentling all HT & LT coils from core for rewinding, and reassembling complete with HT/LT coils to core, required necessary numax paper insulation, insulating press board, precompressed board size of 6mm/3mm/1.5mm/1mm, vernishing, heating to achive insulation level not less than 1000 megaohms at both HT & LT side, core at transformer chamber, tap changer assy, terminal connection, top cover with new cork sheet gusket, required existing/new nuts, bolts & washers, filling transformer oil, testing after repair complete all as specified and directed for the 63-750 KVA, 11/0.433 KV transformer. (Note:- Opening of top cover, Rewinding of HT/LT coils, transformer oil, nuts, bolts & washers, HT/LT busings, required new mesured separately under appropriate item)
M&L for rewinding of HT coils suitable for 11000 volts grade with new DPC/super enamelled copper wire having Class-F insulation as per existing size and turns for capacity of transformer 63-750 KVA
M&L for rewinding of LT coils suitable for 1100 volts grade with new DPC /super enamelled copper strip having Class-F insulation as per existing size and turns for capacity of transformer 63-750 KVA
M&L for rewinding of LT coils suitable for 1100 volts grade with existing DPC /super enamelled copper strip having Class-F insulation as per existing turns for capacity of transformer 63-750 KVA
M&L for replacement of Charging Motor for main incomming HT Panel, ABB Make Panel. M/s Delco or equivalent
M/S KUNKAPU ENTERPRISES
M/S T D Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .