Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.2 CrAdmitted-Finance | ₹3.2 Cr | L1 | Admitted-Finance |
| 2 | L2₹3.4 Cr+₹26.8 L (8.45%)Admitted-Finance 135 CHAKRANA TIWARI CHAKA NAINI PRAYAGRAJ 211008 UTTAR PRADESH | PRAYAGRAJ | UTTAR PRADESH | 211008 | ₹3.4 Cr+₹26.8 L (8.45%) | L2 | Admitted-Finance |
| 3 | L3₹3.5 Cr+₹29.2 L (9.22%)Admitted-Finance | ₹3.5 Cr+₹29.2 L (9.22%) | L3 | Admitted-Finance |
| 4 | L4₹3.5 Cr+₹35.4 L (11.2%)Admitted-Finance | ₹3.5 Cr+₹35.4 L (11.2%) | L4 | Admitted-Finance |
| 5 | L5₹3.5 Cr+₹37.8 L (11.9%)Admitted-Finance | ₹3.5 Cr+₹37.8 L (11.9%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | vijay builders L2 | AJAY CONSTRUCTION L5 | INDUSTRIAL ELECTRICALS L3 | POWER SOLUTIONS L4 | M/s R.S CONSTRUCTIONS L1 | Pawan Kumar L6 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00SITC of 33 kV TRANSFORMER BAY of 2 Tier Double Bus Scheme | |||||||||
| 2.00 | i) 33 kV Vacuum Circuit Breaker (36 kV, 1250A, 26.2 kA, Outdoor Type) SCADA compatible Make Megawin, Crompton Greaves, Electricfield or Equvalent . | 2 | nos | 3,50,000 ₹7,00,000 | 3,42,125 ₹6,84,250 | 4,00,000 ₹8,00,000 | 3,70,500 ₹7,41,000 | 3,00,000 ₹6,00,000 Lowest | 4,50,000 ₹9,00,000 |
| 3.00 | ii) 33kv Isolator without Earthing Blade (36kv , 1250A,outdoor,3 poles, 25KA ). | 2 | set | 60,000 ₹1,20,000 | 68,425 ₹1,36,850 | 60,000 ₹1,20,000 | 58,800 ₹1,17,600 | 50,000 ₹1,00,000 Lowest | 80,000 ₹1,60,000 |
| 4.00 | iii) 33 kV Current transformer (33kv,1 phase multi ratio multi core, outdoor) 1 no per phase | 2 | set of 3 | 1,30,000 ₹2,60,000 | 1,72,431 ₹3,44,862 | 1,80,000 ₹3,60,000 | 1,55,500 ₹3,11,000 | 80,000 ₹1,60,000 | 75,000 ₹1,50,000 Lowest |
| 5.00 | iv) 30 kv Lightening arrestors (30kv,10KA, Polymer, station class, ZnO)gap less | 6 | set | 20,000 ₹1,20,000 | 30,107 ₹1,80,642 | 30,000 ₹1,80,000 | 17,500 ₹1,05,000 | 12,000 ₹72,000 Lowest | 15,000 ₹90,000 |
| 6.00 | 33 kV C&R Panel along with O/C, E/F and differential relays (IEC61850), mimic diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Tri-vector meter -5 Amps, DLMS Compliant with RS-485 port SCADA Compatible. | 2 | nos | 2,50,000 ₹5,00,000 | 4,31,078 ₹8,62,156 | 3,50,000 ₹7,00,000 | 4,75,500 ₹9,51,000 | 2,00,000 ₹4,00,000 Lowest | 4,25,000 ₹8,50,000 |
| 7.00 | 33 kV Post Insulator Polymer 36kV,235kV Impulse, creepage distance 1224m station type | 6 | nos | 2,500 ₹15,000 | 1,642 ₹9,852 | 2,000 ₹12,000 | 1,050 ₹6,300 | 1,000 ₹6,000 Lowest | 5,000 ₹30,000 |
| 8.00 | Pipe Structure - nominal bore 200,5.9 mm thick | 3.74 | MT | 1,30,000 ₹4,86,200 | 1,57,378 ₹5,88,593.72 | 1,40,000 ₹5,23,600 | 1,35,500 ₹5,06,770 | 1,20,000 ₹4,48,800 Lowest | 1,50,000 ₹5,61,000 |
| 9.00 | Galvanised Steel Structures | 2.08 | MT | 1,30,000 ₹2,70,400 | 1,23,165 ₹2,56,183.2 | 1,40,000 ₹2,91,200 | 1,30,500 ₹2,71,440 | 1,20,000 ₹2,49,600 Lowest | 1,50,000 ₹3,12,000 |
| 10.00 | Galvanised Nuts & Bolts | 0.3 | MT | 2,00,000 ₹60,000 | 1,50,535 ₹45,160.5 | 1,50,000 ₹45,000 | 1,55,500 ₹46,650 | 1,20,000 ₹36,000 Lowest | 1,50,000 ₹45,000 |
Tender Value
Refer Docs
EMD Value
₹12 L
Closing Date
11 Nov 2025, 4:30 pmClosed
Executive Engineer ,STD Udhampur
Udhampur, Opp Hotel Singh Axis
Attached
2025_PDD_291053_1
16
Open Tender
Electrical Works
Turn-key
270 days
Udhampur
Please refer Tender documents.
2 documents required · 2 mandatory
₹4,000
Executive Engineer ,STD Udhampur
₹12 L
Office of Executive Engineer,STD Udhampur
27 Nov 2025
7 Oct 2025
12 Nov 2025
7 Oct 2025
11 Nov 2025
10 Oct 2025
9 Oct 2025
Amount
SITC of 33 kV TRANSFORMER BAY of 2 Tier Double Bus Scheme
i) 33 kV Vacuum Circuit Breaker (36 kV, 1250A, 26.2 kA, Outdoor Type) SCADA compatible Make Megawin, Crompton Greaves, Electricfield or Equvalent .
ii) 33kv Isolator without Earthing Blade (36kv , 1250A,outdoor,3 poles, 25KA ).
iii) 33 kV Current transformer (33kv,1 phase multi ratio multi core, outdoor) 1 no per phase
iv) 30 kv Lightening arrestors (30kv,10KA, Polymer, station class, ZnO)gap less
33 kV C&R Panel along with O/C, E/F and differential relays (IEC61850), mimic diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Tri-vector meter -5 Amps, DLMS Compliant with RS-485 port SCADA Compatible.
33 kV Post Insulator Polymer 36kV,235kV Impulse, creepage distance 1224m station type
Pipe Structure - nominal bore 200,5.9 mm thick
Galvanised Steel Structures
Galvanised Nuts & Bolts
CONTROL CABLES : i) 12 Core 2.5mm2 control cable copper armoured, 1.1KV Grade ISI,FRLS of make Havells, Polycab,etc. a
ii) 8 Core 2.5mm2 control cable copper armoured, 1.1KV Grade ISI,FRLS of make Havells, Polycab,etc.
iii) 2 Core 2.5mm2 control cable copper armoured, 1.1KV Grade ISI,FRLS of make Havells, Polycab,etc.
iv) Lugs, Ferrules etc.
Conductor and Hardware : i)ACSR Panther Conductor (for main busbar/ droppers/jumpers)
ii) T Clamps for ACSR Panther Conductor
SITC of POWER TRANSFORMER (2 * 3.15 MVA)
33/11kV, 3 phase ONAN, Copper wound, Out-door Type, conventional Power Transformer, Oil Filled with OLTC and all accessories including HT and LT Terminal connections (3.15 MVA) as per latest IS Standards. (efficiency level 2) .aslo refer to detailed GTPs in SBD.
12 Core 2.5mm2 control cable copper armoured, 1.1KV Grade ISI,FRLS of make Havells, Polycab,etc. a
6 Core 2.5mm2 control cable copper armoured, 1.1KV Grade ISI,FRLS of make Havells, Polycab,etc.
2 Core 2.5mm2 control cable copper armoured, 1.1KV Grade ISI,FRLS of make Havells, Polycab,etc.
SITC of 11 kV INDOOR SWITCHGEAR OF 33/11 kV SUBSTATION
11 kV VCB Panel Board Set (12 kV, 1250A, 25 kA, Indoor) with O/C, E/F relays (IEC61850), Mimic Diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Tri-vector meter -5 Amps, DLMS Compliant with RS-485 port SCADA Compatible etc MAKE :- Seimens, Megawin, Pascal, Electricfield or equivalent :- For 3.15 MVA Power Transformer (1+4) including Smart meters Trivector.
11kV, Gapless Surge Arrestor,9 KV ,10 KA ,LA with Polymer housing, Stn. Type (5Sets Station type 1 for Power Tx))
11 kV 3- Core XLPE 240 mm² armoured, FRLS
11 kV 3- Core XLPE 120 mm² armoured, FRLS
11 kV Indoor Heat Shrinkable Cable Termination Kits for incomer(Indoor)
11 kV Indoor Heat Shrinkable Cable Termination Kits for incomer (outdoor )
11 kV Indoor Heat Shrinkable Cable Termination Kits for outgoing (indoor)
11 kV Indoor Heat Shrinkable Cable Termination Kits for outgoing (outdoor)
11 kV Isolator, double break,3-pole, 600Amp, horizental mounting Type, with Earth Switch.
11kV DO set , AB Switch 3-Phase, 3-Pole, 200 Amp
Galvanised iron of sorts
9 Mtr. Long Pole(ST-410 SP33)
Cement bottoming 1:2:4 mix as per REC standards 0.5cum per pole
Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI strip for ST poles
100KVA 11Kv/433V Auxillary Transformer (level 2)
Earthing for 100KVA Auxillary Transformer (complete as per REC standards)
MCCB 200 Amp with box
120 mm sq PVC LT cable 4 core Armoured
COMMON MISCELLENOUS Equipments
Supply, Errection, Testing & commisioning of Battery Bank 32v 100AH of 15+1 No. cells of 2V each, sealed maintenance free VRLA type, Hgh Impact Polyprophelene copolymer container flame retardant of make Exide Amaron or Tata etc.
Supply, Errection, Testing & commisioning of Float-Cum-boost Charger with full wave rectification for 220v, 1 Phase 50HZ AC input supply suitable for charging of Battery Bank 32V, 100AH of 15+1 No. cells of 2V each, sealed maintenance free VRLA type, Hgh Impact Polyprophelene copolymer container flame retardant.
Distribution Panel (30 V, DC) made of CRCA thickness not less than 2mm. Powder Coated, degree of protection IP43 for 2 No battery incoming supply with 2 No 63 Amps DP MCBs for incoming supply Double busbar of adequate size, 12 No DP DC MCB (0-32A) including indication lamps and cables and other accessories
Distribution Panel (415 V, AC) made of CRCA thickness not less than 2mm. Powder Coated, degree of protection IP43. 200 Amps Switch Fuse disconnector for incoming supply and 5 No TPN MCB's (16-125 Amps ) and 5 No DP MCBs (0-32A),Rectangular busbar suitable for 200 Amps continuous Supply including indication lamps and cables and other accessories
Rubber Mat 1mx2m 19mm thick with ISI mark
Fire Extingiusher Co₂ Type of 4.5 kg capacity for control room (with ISI mark)
3 Sand Bucket Fire Extingiusher including MS stand
FRP Industrial Helmet Chin Straped and Nape Strap with ISI Mark. Make Motwane/Arc.
Rubber Gloves for 33 kV level
Rubber Gloves for 11kV level
Safety Belt (with ISI mark)
Safety Shoes ( 33 KV level)
Earthing rod (set of 3 rods) ( 33 KV level)
HV Neon Tester ( Non-Contact Type)/ live Phase Detector
TOOL KIT Complete with tool box
High Voltage Detector Watches
Telecommunication Facility/optic fibre landline connection
Civil /Misc Works
Compound Walling of identified land by way of Mass Concrete in Foundations and 228 mm bricks of 2 metre height and plastering in 1:5 cement mortar
GI Chainlink Fencing of 33 kV Yard of Substation by way of Mass Concrete in Foundations and chainlink fencing of 6 ft height with MS angle 65 x 65 x 6 mm Posts and GI Flats 50 x 6 mm
Cable Trench for laying of cables from Power Transformer to Control Room with duct covering including separate trays for power and control cables.(1m x 1m x 0.6 m) size as per REC standards
Land development by manual/mechanical means for construction of control room building and staff quarters
Earth work in excavation by mechanical means (hydraulic excavator) in all sorts of soft/hard/normal rockin trenches for foundations, drains, pipes, cables etc. upto 2.5 m depth, including getting out excavated earth and disposal of surplus excavated earth as directed by the Engineer in charge .
BUILDING: A. Control Room Building on ground floor complete with Column and Beam structures with 1 no J.E. Room , 1 Store room, 1 Battery Room and a main hall including aluminium windows, cable ducts for power and control cable, Toilet (complete with WC, Washbasin and fittings), electric fittings(fans, LED tubelights, leds powerpoints and other fixtures)White Washing of entire building , painting of doors and windows etc. Overhead water Storage tanks . 2 nos of office tables and 6 nos of chairs , staircase . Water Supply . Septic Tank complete with Sanitary Fittings including kota stone floor . including RCC slab in furnished conditioncomplete in all respects. (Note: The Contractor shall submit the building drawing in all respects i.e. structural / architectural prepared by authorized Architect for approval from the dept for execution of works.)
BUILDING: B .Staff Quarters on 1st floor with Column and Beam structures including Toilet (complete with WC, Washbasin and fittings), electric fittings(fans, LED tubelights, leds powerpoints and other fixtures) White Washing of entire building Complete in all respectsainting of doors and windows etc. Overhead water Storage tanks . Pantry Room with all the Fittings. Water Supply . including marble flooring . (Note: The Contractor shall submit the building drawing in all respects i.e. structral / architechural prepared by authorised Architect for approval from the dept for execution of works.)
Construction of approach path by Way of Cement concreteing/ Interlocking tiles/blacktopping including drains complete.
33/11 kV Power Transformer Foundation(20 cum) 1:2:4 cc (3m x 3m x 3 m)as per REC standards
33 kV Equipment Foundation & Gantry foundation (40 cum)1:2:4 cc as pe REC standards.
Providing & Laying of Earthmat by Using G.I. Flat of Size 50 mm x 8mm as grounding Conductor.The mesh Size shall be 1 m x 1 m.The Burial Depth of G.I. Flat Shall be minimum 600 mm.The work involves the excavation of trenches for burial of grounding flat,Laying of G.I.Flat including welding & Backfilling of Trenches
GI Earthing Electrode (40 mm dia x3 metre) through GI strip
33 KV Yard Concreting with 1: 4 :8 with 20 mm nominal stone aggregate 4 inch thick & RCC 1 :2 :4 with 20 mm nominal stone aggregate 4 " thick. With earthing pits for water etc.
33 kV Yard Lighting ( 100 Wt LEDs on 9 mtr ST poles) complete with earting , cement bottoming GI brackets, control box , cable etc.
Tool kit
Rubber Mats( 2 mtr x 2 mtr x 25 mm)
Main Gate
RCC Drain work complete in all respects including centring/ shuttering/earthwork and disposal therof.
SITC of 33 kV Line in Line out at Receiving Station Dairy Farm
i) 33 kV Vacuum Circuit Breaker (36 kV, 1250A, 26.2 kA, Outdoor Type) SCADA compatible Make Megawin, Crompton Greaves, Electricfield or Equvalent .
ii) 33kv Isolator with Earthing Blade (36kv , 1250A,outdoor,3 poles, 25KA ).
ii) 33kv Isolator without Earthing Blade (36kv , 1250A,outdoor,3 poles, 25KA ).
iii) 33 kV Current transformer (33kv,1 phase multi ratio multi core, outdoor) 1 no per phase
iv) 30 kv Lightening arrestors (30kv,10KA, Polymer, station class, ZnO)gap less
33 kV C&R Panel along with O/C, E/F and differential relays (IEC61850), mimic diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Tri-vector meter -5 Amps, DLMS Compliant with RS-485 port SCADA Compatible.
33 KV voltage transformer(33kv/110 V, 1 phase, multicore, outdoor)1 no per phase
33 kV Post Insulator Polymer 36kV,235kV Impulse, creepage distance 1224m station type
Galvanised Steel Structures
Galvanised Nuts & Bolts
CONTROL CABLES : i) 12 Core 2.5mm2 control cable copper armoured, 1.1KV Grade ISI,FRLS of make Havells, Polycab,etc. a
ii) 8 Core 2.5mm2 control cable copper armoured, 1.1KV Grade ISI,FRLS of make Havells, Polycab,etc.
iii) 2 Core 2.5mm2 control cable copper armoured, 1.1KV Grade ISI,FRLS of make Havells, Polycab,etc.
iv) Lugs, Ferrules etc.
Conductor and Hardware : i)ACSR Panther Conductor (for main busbar/ droppers/jumpers)
ii) T Clamps for ACSR Panther Conductor
Earth Wire 7/ 3.15 mm
33 KV Disc Insulator 120 KN (polymeric)
Earthing of equipment GI flat 25 X5 mm.
Single Tension fittings for ACSR Panther Conductor
SITC of 33 kV Line in Line out at Receiving Station Sateney
i) 33 kV Vacuum Circuit Breaker (36 kV, 1250A, 26.2 kA, Outdoor Type) SCADA compatible Make Megawin, Crompton Greaves, Electricfield or Equvalent .
ii) 33kv Isolator with Earthing Blade (36kv , 1250A,outdoor,3 poles, 25KA ).
ii) 33kv Isolator without Earthing Blade (36kv , 1250A,outdoor,3 poles, 25KA ).
iii) 33 kV Current transformer (33kv,1 phase multi ratio multi core, outdoor) 1 no per phase
iv) 30 kv Lightening arrestors (30kv,10KA, Polymer, station class, ZnO)gap less
33 kV C&R Panel along with O/C, E/F and differential relays (IEC61850), mimic diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Tri-vector meter -5 Amps, DLMS Compliant with RS-485 port SCADA Compatible.
33 KV voltage transformer(33kv/110 V, 1 phase, multicore, outdoor)1 no per phase
33 kV Post Insulator Polymer 36kV,235kV Impulse, creepage distance 1224m station type
Galvanised Steel Structures
Galvanised Nuts & Bolts
CONTROL CABLES : i) 12 Core 2.5mm2 control cable copper armoured, 1.1KV Grade ISI,FRLS of make Havells, Polycab,etc. a
ii) 8 Core 2.5mm2 control cable copper armoured, 1.1KV Grade ISI,FRLS of make Havells, Polycab,etc.
iii) 2 Core 2.5mm2 control cable copper armoured, 1.1KV Grade ISI,FRLS of make Havells, Polycab,etc.
iv) Lugs, Ferrules etc.
Conductor and Hardware : i)ACSR Panther Conductor (for main busbar/ droppers/jumpers)
ii) T Clamps for ACSR Panther Conductor
Earth Wire 7/ 3.15 mm
33 KV Disc Insulator 120 KN (polymeric)
Earthing of equipment GI flat 25 X5 mm.
Single Tension fittings for ACSR Panther Conductor
Manning and Operation charges of 33 KV Receiving station( 24 x 7)by way of providing adequate Manpower per Shift for 1 year.
Creation of Isolation points along the line by way of 33 KV Isolators with earthing blades( 1 no) on 11 Mtr ST Poles structure ( 2 nos of poles), 100 sqmm ACSR conductor (0.1 km) , 33 KV Pin insulators( 6 nos) , 33 KV Disc insulators (6 nos), and MS Steel etc. along with earthing by GI Pipe or GI rod each -Complete job.
vijay builders (BID ID -2618190)
INDUSTRIAL ELECTRICALS (BID ID -2629314)
POWER SOLUTIONS (BID ID -2629304)
AJAY CONSTRUCTION (BID ID -2618418)
Pawan Kumar (BID ID -2617565)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.17 MB
BOQ_935313.xls
BOQ • 0.38 MB
SBDMES.pdf
Tender Documents • 7.43 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .