Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance NO 4 SRIRAMULU VILLA MULLAI STREET KANDAN NAGAR TIRUTTANI 631209 | TIRUTTANI | THIRUVALLUR | TAMIL NADU | 631209 | Admitted-Finance |
Tender Value
₹10.0 L
EMD Value
₹20,000
Closing Date
19 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I RD AVADI
AGE I RD AVADI CHENNAI 600054
PROVISION OF CERTAIN EM MINOR WORKS AND PETTY REPAIRS AT CVRDE AVADI
2020_MES_397242_1
8344/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AVADI
AS per NIT
8 documents required · 8 mandatory
₹500
AGE I RD AVADI
₹20,000
Yes
28 Dec 2020
23 Nov 2020
21 Dec 2020
23 Nov 2020
19 Dec 2020
5 Dec 2020
23 Nov 2020 - 5 Dec 2020
60 days
Amount
Phast - I Constst of BOQ Item No. 1.01 to 1.35 (Maintenance works) Notes for BOQ items No. 1.01 to 1.35:- 1) Contractor shall provide and deploy adequate experience tradesmen to carry out day to day repair against complaint in MES complaint centre at Bhartiyar nagar 0830 hrs to 1630 hrs on all days. Contractor shall be penalised @ Rs. 120/- per complaint per day, If fails to attend the complaint within 8 hours. 2) In case of any breakdown /emergency contractor shall make arrangement to attend and rectify the complaints in odd hours on Sunday holiday also. The rates quoted by contractor shall deemed to be include this aspect. Every day contractor shall deposit the completed job card to complaint cell/JE. 3) The contractor will get the names of tradesman approved from Engr-in-Charge. The accepting officer reserves the right to reject the employment of such person forthwith. No claim what-so ever be entertained on this regard.
Supply and fix switch piano flush button type 15 amps single pole one way complete all as specified and directed.
Supply and fix switch piano flush button type 5 amps single pole one way complete all as specified and directed.M
Supply and fix Switch socket combination 6/16 A 250V AC universal with box in polycarbonate. complete all as specified and directed.
Supply and fix socket outlet multipurpose 2 in 1, 5 and 15 Amps. complete all as specified and directed.
Supply and fix socket outlet multipurpose 2/3 pin 5 amps flush button. complete all as specified and directed.
Supply and fix replacement fan regulator, electronic, step type 100 watt and connection complete as directed, after dismantling / removing unserviceable regulator.
Supply and fix electric bell Ding-Dong AC 230 Volt SP with brass screws and cup washers. complete all as specified and directed.
Supply and fix bell push flush type 5 amps complete all as specified and directed.
Supply and fix single pole and neutral enclosure with a two pin earth plug and socket complete with one single pole MCB 20 Amp.
Supply and fix Sheet metal enclosure (MCB DB), single phase and neutral with 200 Amps rated bus bar, single door type, 240 volts complete for the following no. of way :-
Supply and fix single core flexiable PVC cable 1.5 sqmm of standrad copper conductor PVC insulated unsheathed cables of 1100 volts complete all as specified and directed.
Supply and fix single core flexiable PVC cable 2.5 sqmm of standrad copper conductor PVC insulated unsheathed cables of 1100 volts complete all as specified and directed.
Supply and fix replacement of capaciator 2.50 Mfd, 240 V. complete all as specified and directed.
Supply and fix Lamp holder, PVC/ Polycarbonate type with back plate suitable for batten fittings. complete all as specified and directed.
Supply and fix Hylem sheet 3 mm thick size 9'' x 11'' including cutting of switch,socket. complete all as specified and directed.
Supply and fix Hylem sheet 3 mm thick size 8'' x 5'' including cutting of switch,socket complete all as specified and directed.
Supply and fix MCB SPN 40 amp, 240 v, 50 Hz AC Made from moulded self-extinguishing thermostat plastic and suitable for 10 KA breaking capacity,
Supply and fix Single pole MCB 6 to 32 amp, 240 v, 50 Hz AC Made from moulded self-extinguishing thermostat plastic and suitable for 10 KA breaking capacity. complete all as specified and directed.
Supply and fix LED bulb of 9 watt complete all as specified and directed.
Supply and fix Flate panal Aesthetically designed 2x2 LED flat panel for surface mounting which provides soft-light and glare free symmetrical illumination 34 watt . complete all as specified and directed.Make:- Havells cart part No BOCR4X1R34WLED857SPCSS /Philips/Wipro
Supply and fix ultra bright glass LED tubelight with very high efficacy 4 ft length with double side connection suited for installation in existing T8 fitting with G13 lamp holders complete all as specified and directed. Make:-Havells Cart Part No CRYSTAL1213T8DSTL20WLED865SGL/Wipro/Philips
Supply and fix surface and wall mounted LED batten, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver with industrial grade heavy duty driver having capacity of 2200 lumens Make :-.Havells Cart Part No ENDURALINEARNEOBS22WLED865SPCWH / Philips cat No. BN021LED25S 6500PSU GR SI
Supply and fix surface mounting 10 watt LED light fitting of (600x108x62) mm complete all as specified and directed. Make Havells Cart Part No ENDURALINEARNEOBS10WLED865SPCWH / Philips cat No. BN021LED10S 6500PSU GR SI
Supply and fix sub main wirng of two run single core 4 Sqmm FRLS PVC insulated stranded copper conductor cable and one single core green FRLS PVC insulated 4 sqmm stranded copper conductor earth continuity cable drawn through non metallic rigid PVC conduit 25 mm dia concealed in wall/ceiling complete all as specified and directed. Note: Copper copper conductor 03 Run and PVC conduit one run shall be measured as one unit.
Supply and fix electronic ballast of 1x36/40w suitable for FTL fittings complete all as directed.
Supply and fix electronic ballast of 1x18 to 28w suitable for FTL fittings complete all as directed.
Taking down geyser 25/50 Ltr capacity of any make/type after disconnecting existing water Supply and electric connections by unscrewing/cutting of holding nut & bolts including opening of top & bottom cover, taking out complete internal assembly including geyser inner tank, inlet/outlet assembly, heating element, thermostat etc and descaling the geysers inner tank by chemical, cleaning and washing complete and re-assembling the same and fixed in position including connecting to electric and water Supply system and including providing and grouting new nut bolts and testing of geyser for leakage and its proper functioning complete all as directed. Note :- i) Defects developed during taking down geysers such as breaking of threads of pipe / geysers and GI fittings etc shall be rectified / replaced by the contractor at his own cost. ii) The heating element, thermostat will be measured and paid separately under supply only.
Supply and replacing flexible PVC connection, heavy duty, 450mm long with CP brass adopter and washers at both ends suitable for hot water for 15mm dia pipe all as specified & directed
Supply only thermostat suitable for 25/50 ltr geyser capacity to control water temperature 20 degree C to 80 degree C, ISI marked complete all as specified & directed
Supply only heating element push/thread type with rubber gasket complete of capacity 1.5 KW/2 KW, ISI marked for 25 ltr cap of geyser of any make complete all as specified & directed
M&L for PVC casing caping of size 20 x 12mm, ISI marked including screw etc as required at site for fixing complete
M&L for Taking down and dismantling existing rolling shutter motor (top / bottom type) of 2HP capacity remove worn out bearing, burnt winding and cleaning, servicing rewinding with suitable copper wire of suitable size, varnishing heating and insulating, replace of bearing/bush as required and assembling, re fixing at site testing complete all as specified and directed.
Phast - II Constst of BOQ Item No. 2.01 to 2.45 (Minor Works)
Excavation in trenches not exceeding 1.5m wide and exc. 1.5m and not exc 3.0m in depth for laying of cable/ erection of pole and getting outand getting out in hard/dense soil complete all as specified and as directed.
Excavation in trenches not exceeding 1.5m wide and not exc. 1.5m depth for laying of cable/ erection of pole and getting and getting out in hard/dense soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm in soft/ loose soil all complete as specified and as directed.
Removing excavated materials (soils)to a distance not exc. 50 mtr and depositing where directed at level not exc 1.5 m above the starting point all complete as specified and as directed.
Supply & laying Sand coarse dry as in cushioning of underground electric cable in trenches, laid to a uniform thickness of 23cm (15cm under the cable & 8cm over the cable ) and gently punned down to 18cm thickness all complete as specified and as directed. Note: Only punned thickness of sand shall be measured.
M & L and testing in trenches or passing through pipe 1100 volts grade, armoured heavy duty XLPE insulated, screened PVC bedded galvanised steel strip armoured heavy duty electric cable with aluminum stranded conductor of cross sectional area 10 sqmm 2 core complete all as specified and directed. Note: Earth work in excavation, sand cushioning, cable cover, cable protection, GI pipe shall be measured and paid separately under relevant item.
Supply and fixing GI tubing light grade required for cable protection along road crossing etc of size 40mm dia all as specified and directed.
Steel tubular swaged poles type 410 SP-31 (9.0 metres long) complete with 1 mtr single arm bracket and mild steel base plate, finial taper, plug, bolts, nuts and screw including two coat of aluminium painting over a coat of red oxide primer for exposed surfaces and two coats of bituminous black paint over a coat of concrete, including two runs of PVC insulated copper wire 2.5sqmm three core from the junction box to the fittings complete all as specified.
M&L Cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in coping to poles including necessary form work all as specified and directed.
M&L Cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundations, filling and mass concrete all as specified and directed.
Supply & Fixing junction box of size 240 x 130 x 95 made of polycarbonate with IP 65 degree of protection , dust proof, water tight, light weight, acid resistant, corrosion proof inslated & shock proof, fire retardant, self extinguishing, halogen & silica free non-toxic material, UV resistant, with internally ebbedded gasket fitted with required terminals for upto size 16 sqmm 4 core cable and hinged from Top and openable from down side and cable entry from sides or down including Glands complete all as specified and directed.
Supply and fix junction box made of inpact resistance plastic & heat resistant materials of size not less than 140mm x 140mm x 95mm, IP 66 protection, single left hinged door including provision of suitable terminal connector 16A capacity with MCB SP 6A and fixing to the surface / light pole with suitable sizes of clamps, nuts and bolts complete all as specifed and directed.
S&F LED street/security light fixture not less than 100Watt LED with pressure die cast aluminium housing with toughened glass,IP-66 degree of protection, luminarie efficacy 100 lumen/watt, colour temperature (CCT) of 5700K with integral electronic driver, surge protection unit with suitable size GI bracket/clamps etc incl taking taking down HPSVMV/MH fittings complete all as specified and directed. Make: Wipro Cat part No LR02-112-XXX-57-G2/Havells Cat No ENDURAPEARLMAGNUMSL100WLED757PASYTOTGA/CG Cat No LSTP-100-CDL-M.
M&L for supply, install, testing and commissioning to electrical system distribution board (outdoor top canopy type), suitable size, factory made, single door, cubical type, back door fixed type, fabricated out of 2 mm thick CRCA steel sheet, powder coated, weather/dust/vermin proof, IP 65 protection, suitably spaced totally enclosed in chamber, with provision to enter light inside the panel for light sensing timer, earthing arrangement, inbuilt locking arrangement with two locks with duplicate key duly and including connection of all incoming and outgoing cables using suitable size lugs and glands, danger notice board, panel to be mounted on PCC 1:2:4 pedestal complete all as specified and directed including comprising of following items :- a) MCB 2 pole 32 amp, 415 volts 10 KA - 01 No. (b) power contactor of capacity 25 Amp, 2 pole, 415 volts, 50 Hz - 01 No. (c) Timer Switch (Analog sensor type) type suitable for single phase distribution System. (d) Indication lamp (R,Y,B) LED type with suitable MCB control for each indicator - set of three
Supply, Install, Testing and commissioning of solar LED standalone street light system includes integral LED street light fitting not less than 20W 12V 2000lumens with in built solar charge controller unit solar panel 80Wp Gel(VRLA) battery 12V 60Ah 2days backup and hot dip galvanished tubular pole 5m with suitable PCC foundation bolts nuts for erecting pole as per OEM specification complete all as directed. Make Havells Cat No 21W Solar SLS/Wipro Cat No LR14-301-XXX-65-XX/CG Cat No CSADHMP20CDL
Sub main wiring with 2 runs of single core 2.5 sqmm 1100 Volts grade, FRLS PVC insulated, unsheathed cable, copper conductor, multistranded drawn through and incl provision of ISI marked PVC conduit 20mm dia medium grade surfcae in walls / roofs / floors etc., including provision of one run FRLS PVC insulated 2.5 sqmm copper conductor as earth continuity conductor and connecting to common earth dolly incl taking down u/s aluminium wiring complete all as specified and directed. Note: Two runs of 2.5sqmm cable, one run of earth continuity conductor shall be measured as one unit length.
M&L for Point wiring with 1100Volts grade, single core, PVC insulated FRLS cable multi-stranded copper conductor of size 1.5 sqmm nominal area for phase and neutral, drawn through and incl provision of ISI marked pvc rigid conduit medium grade 20mm with all necessary fittings and accessories for surface wiring fixed on walls/ ceiling with one run of single core cable of same description above but green colour in continous earthing wire connected to common earth dolly including metal boxes for one light point controlled by one switcht complete all as specifed and directed.
S&F Switch piano, flush type single pole, one way 5 Amp all as specifed and directed.
S&F batten 4 feet LED tube light fitting 20W high lumen efficiency, min 5700K and extruded aluminium/ polycarbonate/ CRCA body with suitable electronic driver, 230V with all accessories pre wired, connecting up with and including twin core twisted flexible copper cable complete inclluding taking down unserviceable FTL fitting any type any watts all as specified and directed. Havells Cat No STOUTPL US1200BS40WLED857SPCWH/WIPRO Cat No LE10-491-XXX-57-XX/Philips BN100C LED40S-6500 PSUL20GR
M&L sheet metal enclosure for MCB DB SPN 8 way, 240 Volts, single phase, double door with IP-43 protection with100 Amps rated busbar suitable for DP MCB as incomer and DP/SP MCB as outgoing, flushed on wall surface and wrting letters as DB Title/Incomer/ Outgoing details in paint over DB door complete all as specified and directed.
M&L MCB DP 20A 240 V 10 KA C Series complete all as specifed and directed
M&L MCB SP 6A 240V 10KA C Series complete all as specifed and directed.
Supply, laying and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 4 core 25 sq mm incl suitable cable glands, termination complete all as specifed and directed.
S&F 4 Pole MCCB 415 V, 50Hz, 16KA 100 A, fixed magnetic release in existing panel with necessary accessories as per site requirment complete all as specifed and directed.
Supply and fix metal clad socket with plug of rating 32 Amps, 230V 50Hz rating 2P+E complete with sheet metal enclosure complete all as specfied and directed
S&F 4 Pole MCCB 415 V, 50Hz, 16KA 100A fixed magnetic release complete all as specifed and directed.
S&F 4 Pole MCCB 415 V , 50Hz, 16KA 63A fixed magnetic release with sheet metal enclusure suitable complete all as specifed and directed.
S&F 3 Pole MCCB 415 V , 50Hz, 16KA 63A fixed magnetic release complete all as specifed and directed.
S&F MCB SP 6A to 32A range, 240V 'C' series, 10 KA breaking capacity & connection complete all as specified and directed.
M&L for comman burnt clay brick sub class 'B' laying in trenches for cable protection complete all as specifed and directed
M&L for sub main wiring with 2 runs of single core 6sqmm 1100 Volts grade, FRLS PVC insulated, unsheathed cable, copper conductor, multistranded drawn through and including ISI marked PVC casing caping of min dimension 25mmx10mm size powder coated finish in walls / roofs / floors etc., including one run of FRLS PVC insulated 6sqmm copper conductor as earth continuity conductor and connecting to common earth dolly complete all as specified and directed. Note: Three runs of cable and one run of PVC casing caping shall be measured as one unit length.
M&L for sub main wiring with 4 runs of single core 10sqmm 1100 Volts grade, FRLS PVC insulated, unsheathed cable, copper conductor, multistranded drawn through and including ISI marked PVC casing caping of min dimension 40mmx20mm size powder coated finish in walls / roofs / floors etc., including provision of FRLS PVC insulated 10sqmm copper conductor as earth continuity conductor and connecting to common earth dolly complete all as specified and directed. Note: Three runs of cable and one run of PVC casing caping shall be measured as one unit length.
M&L flush mounted Sheet metal enclosure for MCB VTPN DB 4Way(8 I/C+12 O/G), 415 Volts, 3 phase with double door, IP-43 protection with copper bus bar of 200 Amp capacity, neutral bar, earth bar suitable for 4P MCCB as incomer and 4P/TPN/DP/SP MCB as outgoing, flushed on wall surface and wrting letters as DB Title/Incomer/Outgoing details in paint over DB door complete all as specified and directed.
M&L for Point wiring with 1100Volts grade, single core, PVC insulated FRLS cable multi-stranded copper conductor of size 2.5 sqmm nominal area for phase and neutral, drawn through and including provision of ISI marked PVC Casing & capping of size 20mmx10mm, with all necessary fittings and accessories fixed on walls/ ceiling with one run of single core cable of same description above but green colour in continous earthing wire connected to common earth dolly including metal boxes , modular cover plate for 5A modular switch socket complete all as specifed and directed.
S&F modular switch 16A, SP one module all as specifed and directed.
S&F modular Socket, 6/16A - 2/3 pin combined 2 module,complete all as specifed and directed.
Supply & fix Air Circulator fans 230 volts 50Hz single phase oscillating 600 mm sweep suitable for wall mounting with suitable bolts,nuts complete all as specifed and directed. Make : Havells Model Turboforce/Almonard/CG
Supply, Install and testing Water cooler not less than 40 ltrs cooling and 80ltrs storage capcity stainles steel storage suitable of operation in refrigerant 134a ozone free gas,230V 50Hz including accessires, complete all as specifed and directed. Make : Blue Star water cooler model No P6080E-SL(Plantinum series) or equivalent Voltas/Usha
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 270 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4KVA complete all as specifed and directed. Make : V Guard Model No VG400 or equivalent.
Supply, Install and testing water purifier inbuilt RO+UV+UF 7stage purification process 7ltrs capacity suitable 230V,50Hz with necessary accessories to connect output of prurifier to water cooler complete all as specifed and directed. Make : Blue Star Model Aristo
M&L for Point wiring with 1100Volts grade, single core, PVC insulated FRLS cable multi-stranded copper conductor of size 1.5 sqmm nominal area for phase and neutral, drawn through and incl provision of ISI marked PVC casing and capping of size 20mmx10mm, with all necessary fittings and accessories fixed on walls/ ceiling with one run of single core cable of same description above but green colour in continous earthing wire connected to common earth dolly including metal boxes , modular cover plate for 5A modular switch socket complete all as specifed and directed.
M&L for Point wiring with 1100Volts grade, single core, PVC insulated FRLS cable multi-stranded copper conductor of size 4sqmm nominal area for phase and neutral, drawn through and incl provision of ISI marked PVC casing and capping of size 20mmx10mm, with all necessary fittings and accessories fixed on walls/ ceiling with one run of single core cable of same description above but green colour in continous earthing wire connected to common earth dolly including metal boxes, modular cover plate for metal clad socket complete all as specifed and directed.
S&F Socket 6A, SP - 2/3 pin combined 2 module, complete
S&F Modular switch, SP, 6A, 1 module complete
Supply and lay pipe galvanized, “Medium class”, including fittings 15 mm (1/2”) dia fixed on wall/floor with all fittings complete all as specifed and directed
SREE VENKATESWARAS CONSTRUCTIONS
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .