Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Not Admitted-Fee/PreQual/Technical NEAR SHIV MANDIR WARD NO 3 INDIRA COLONY KATHUA M S EMINENT ENGINEERING SERVICES 184101 KATHUA KATHUA JAMMU KASHMIR 184102 | KATHUA | JAMMU AND KASHMIR | 184101 | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
Refer Docs
EMD Value
₹14,760
Closing Date
29 Jan 2021, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Er Pawan Tickoo
Executive Engineer PWD RandB Electric Div Jammu
please refer BOQ
2021_PWDJK_114052_1
Fresh e-NIT No.EDJ/147 of 2020-21 Dated 18-01-2021
Open Tender
Electrical Works
Item Rate
Govt Degree College for Women Kathua
please refer to NIT
2 documents required · 2 mandatory
₹600
Yes
Executive Engineer PWD RandB Electric Div Jammu
₹14,760
Yes
9 Feb 2021
18 Jan 2021
30 Jan 2021
19 Jan 2021
29 Jan 2021
19 Jan 2021
120 days
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 x 2.5 sq mm + 1 x 2.5 sq. mm earth wire
2 X 10 sq. mm + 1 X 6 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required.
1 x 1.5 sq. mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface /recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 A switch
3 pin 5/6 A socket outlet
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
6 way (4 + 18), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single Pole
Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
Supply, installation, testing & commissioning of GI Electrode Earthing with 50mm dia and 3 meter length, with 3mm thick the electrode should be hot-dip galvinised. The GI Electrode shall be pre-filled with Cristaline Conductive Materila (CCM). The GI electrode shall be surrounded with BEE MOIST compound to provide maximum contact betwen the electrode and compound should be eco-friendly and having ROHS certification GI Electrode Earthing should be maintinance free and does not require regular manual addition of water GI Electrode shall be tested from CPRI. The earthing pit should be covered with PVC cover.
Providing and laying of 25 x 3 mm G.I strip from G.I rod upto the main panel.
Supplying and fixing of following rating 240 Volt's "C" Series miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning (Make as per annexure enclosed).
Single Pole and Neutral 63 Amp.
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. (1 run of cable)
Supplying and fixing of surface LED panel square/circular 18 watt LED type including connections etc as required.
Supplying and fixing of 2 feet mirror light 9 watt LED type.
Supplying and fixing of 20/22 watt LED 4 feet tube light fitting/fixture CRCA housing with 2000 Lumens and min lumens efficiency 100 Lumens/watt P.F 70.95 THD < 16% & voltage input range 140-270 V with Shot circuit & overloading protection circuit off
Providing and fixing of L.T switch gear power control panel floor/Wall mounted Indoor type totally enclosed, compartmentalized, cubical made of 2mm thick sheet duly powder coated free from dents, dust uneven surfaces and vermin proof (as per technical specifications suitable for 415 volts 3 phase 4 wire 50 HZ AC supply complete with hinged doors having looking arrangment with provision of space for MCCB. COS, Bus Bar etc as required. The job includes interconnections testing, commissioning and providing earthing connection to panel.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
MCCB FP 100 Amp. 30 KA ICU=ICS=100%
Aluminium Bus bar 200 amp 4 strip.
Supplying and fixing of 70 watt LED Street Light complete with GI pipe bracket duly embeded along the parapet /wall including wiring with 1.5 sq.mm FRLS PVC insulated copper wire with controlling switch.
Supplying and fixing of following electrical items suitable for operating on 240/230Volts AC, 50 Hz supply.
Ceiling Fan (including Providing and fixing of 1.5' long fan rods) 1200 mm Sweep.
Exhaust fan 300 mm Heavy duty
Wall fan 400 mm size
Supplying and fixing of Electrical items.
Round Sheet
Fan Sheet
Supply and fixing of 1.1kV grade , XLPE insulated, Aluminium conductor, Heavy Duty , Armoured cables of following ratings as per IS : 7098 Part-1 with latest amendments.
3.5 C x 35 sqmm Armoured
GLOBAL ENGINEERS
Des Raj Dabgotra
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .