Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.9 LAccepted-AOC | L1 | Accepted-AOC AoC | |
| 2 | L2₹10.6 L+₹1.1 L (12.0%)Rejected-Finance NAGAR PANCHAYAT PATHARDEVA DEORIA | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹11.0 L+₹1.5 L (15.6%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹12.9 L+₹3.4 L (35.9%)Rejected-Finance NOT FOUND | L4 | Rejected-Finance Other than L1 |
| Sl No | Description | Qty | Unit | M/s Shree Bala Ji Construction Company L2 | shiv shanker enterprises L4 | M/S KAVYA ENTERPRISES L1 | NISHTHA BUILDERS L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | M&L Checking of Earth Resistance of Chemical/Normal Earthing and maintaining the Register as per Appendix 'A' and as specified and directed here-in-after :-
NOTES :-
(a) Contractor will Check Earth Resistance Every Day (minimum 25 Nos. per Day) and joint measurement of earth resistance of chemical /plate electrode earthing with user, will be sole responsibility of contractor. Earthing register will maintain and signed by user also and same will be put up to the Engineer-in-Charge through JE E/M on the Very Next Day, failing which a Sum of Rs. 20.00 per Day will be recovered from the Contractor.
(b) New Earth Resistance Tester will be provided by the Contractor. (Tester should be caliberated from NABL accredited labs).
(c) Contractor will be responsible for pouring of water in the Earth Pits Weekly at his own arrangement with Water Tanker, etc. However, Water will be provided by the Department.
(d) Checking of Earth Pits existing and improve it by watering, adding of chemical etc. (Chemical will be measured and paid separately)
(e) Contractor will be responsible for marking of Earth Check date and due date on existing Plate with paint as specified by Engineer-in-Charge.
(f) Contractor will be responsible for cleaning of bushes, grass, sand etc inside and all around upto 1.50 Metre Area of existing Earth Pit with tightening of Strip.
(g) Repair Party will be report every Morning and Evening to JE E/M. | 6,500 | EACH EARTH PIT | 30 ₹1,95,000 | 29 ₹1,88,500 | 20 ₹1,30,000 Lowest | 60 ₹3,90,000 |
| 1.01Item No 1.01 (Contd...) (h) Cost of register for noting earthing results, location wise shall deemed to be included with the unit rate. Proforma of detail column will be printed as per the direction of Engineer-in-charge. (j) Recovery for Penalty will be made as follows :- (i) Earthing left without Checked lesser by 25 No. - Rs. 50.00/Earthing (ii) Earthing left without Checked in a Month - Rs. 100.00/Earthing (iii) Earthing left without Cleaning in a Month - Rs. 50.00/Earthing (iv) Earthing left without Watering in a Month - Rs. 30.00/Earthing (k) Contractor will be responsible for maintaining permissible earth resistance in Ohms in Earthing Register, failing which he will be liable to pay penalty as per IAFW-2249 and work shall be re-done by contractor in their quoted rate. | |||||||
| 2.00 | M&L for dismantling/taking out old unserviceable Chemical/Conventional earthing pit with all accessories after disconnection of earth strips including earth work as required complete all as specified and as directed. | 40 | Each Job | 10 ₹400 Lowest | 20 ₹800 | 10 ₹400 Lowest | 30 ₹1,200 |
| 3.00 | Supply, installation, testing of CPRI tested maintenance free earthing system a set of Copper Bonded Earth Rod of 3 meter length, 17.2 mm dia made of high tensile low carbon steel circular rods, molecularly bonded with 99.9% electrolytic grade copper on outer surface (minimum copper bonding thickness-250 microns) with exothermically jointed copper bus bar of 200x50x6mm for long lasting and connection, copper bonded rod & exothermically jointed bus bar duly CPRI tested on 25 KA fault current and earth pit filled with duly by electrodite/conductolite back fill comound (Ground enhancer) complete for achieving earth resistance not more than 01 Ohm including boring in loose/soft soil 200mm dia, by means of hand/ machine drill, upto 3 Meter depth from ground level and pouring of sufficient water for at least 3 times per day (within working hours) for two days and making hole ready for pouring of Earth Enhancement Compound complete all as specified and directed.
(NOTE: Pit Cover and ground enhancing compound shall be measured and paid seperately) | 50 | Each Job | 2,400 ₹1,20,000 | 3,750 ₹1,87,500 | 1,500 ₹75,000 Lowest | 1,900 ₹95,000 |
| 4.00 | Supply and pouring of RoHS tested Earth Enhancement Compound after mixing with water tested by NABL accredited lab in compliance to IEC 62561-7 with a resistivity < 0.12 ohm-m. It shall be free from bentonite and other hazardous substances. It shall be a permanent, non-corrosive material and will not leach any chemicals into the ground. It shall retain moisture even in high soil resistivity areas. complete all as specified and as directed.
Note: Measurement of Chemical will be done in Powder form. Contractor shall procure the item in sealed packets directly from manufacturer) | 3,000 | KG | 10 ₹30,000 Lowest | 22 ₹66,000 | 15 ₹45,000 | 21 ₹63,000 |
| 5.00 | S&F Earth Pit 125mm dia with FRP Earth Pit Cover of top size 200x200mm bottom size 300x300mm with height of 150mm with lockable Lid, Earth Pit cover shall be made of Poly plastic tested at 7.5 ton load for closing of earth pits complete all as specified and as directed. | 50 | Each | 400 ₹20,000 | 270 ₹13,500 | 255 ₹12,750 | 195 ₹9,750 Lowest |
| 6.00 | M&L for replacement of PCC earth Pit with Cement Concrete 1:3:6 type C-1 (20mm graded crushed stone aggregate) including demolition of existing damaged pit and excavation work required at site and making good surfaces and site clearance complete all as specified and as directed.
Notes :
1) Quoted Rate shall be included for dismantling and removal debris of existing PCC pit.
2) Existing cover shall be re-fixed. If new cover is required, the same shall be measured & paid seperately. | 4 | CUM | 1,200 ₹4,800 Lowest | 5,000 ₹20,000 | 2,000 ₹8,000 | 1,290 ₹5,160 |
| 7.00 | M&L for replacement of Pre-cast RCC Cover with Handle 01 Nos and hole of dia 40mm in Cement Concrete 1:2:4 (20mm graded stone aggregate) of size 540x540x60mm, reinforced with and including 10mm dia TMT Bars @ 200 mm Centre to Centre in both ways, complete all as specified and directed.
Note : Rate shall be included for dismantling and removal debris of existing RCC cover pit. | 1 | CUM | 1,500 ₹1,500 | 7,161 ₹7,161 | 200 ₹200 Lowest | 3,100 ₹3,100 |
| 8.00 | M&L Checking of any breaking in the Link of Earth Strip/Wire of Galvanised/ Copper/Aluminium any size and jointing them by Exothermic Welding or Brazing, complete all as specified and as directed. | 300 | Each Joint | 20 ₹6,000 Lowest | 50 ₹15,000 | 50 ₹15,000 | 70 ₹21,000 |
| 9.00 | Taking out loose/displaced Serviceable Aluminium Strip/ Copper Strip/ GI Strip of any size and any description with Accessories and refixing the same with necessary Fixing Arrangement like Screws, Saddles, insulators, Nuts and Bolts, complete all as specified and as directed.
Note : Cost of Screws, Saddles, insulators, Nuts and Bolts etc. shall be deemed to be included in Quoted Rate. | 300 | RM | 20 ₹6,000 | 20 ₹6,000 | 10 ₹3,000 Lowest | 30 ₹9,000 |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
25 Jun 2026, 6:00 pmClosed
GE (AF) SIRSA
GARRISON ENGINEER AIR FORCE STATION SIRSA HARYANA-125055
REPAIR MAINT OF EXISTING EARTHING LA SYSTEM AND CONNECTED E/M WORKS AT AF STN SIRSA
2026_MES_771544_1
GE/SRA/T-07/2026-27
Open Tender
Miscellaneous Works
Item Rate
240 days
GE (AF) SIRSA
PLEASE REFER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE (AF) SIRSA
₹30,000
Yes
4 Aug 2026
11 Jun 2026
26 Jun 2026
11 Jun 2026
25 Jun 2026
20 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M&L Checking of Earth Resistance of Chemical/Normal Earthing and maintaining the Register as per Appendix 'A' and as specified and directed here-in-after :-
NOTES :-
(a) Contractor will Check Earth Resistance Every Day (minimum 25 Nos. per Day) and joint measurement of earth resistance of chemical /plate electrode earthing with user, will be sole responsibility of contractor. Earthing register will maintain and signed by user also and same will be put up to the Engineer-in-Charge through JE E/M on the Very Next Day, failing which a Sum of Rs. 20.00 per Day will be recovered from the Contractor.
(b) New Earth Resistance Tester will be provided by the Contractor. (Tester should be caliberated from NABL accredited labs).
(c) Contractor will be responsible for pouring of water in the Earth Pits Weekly at his own arrangement with Water Tanker, etc. However, Water will be provided by the Department.
(d) Checking of Earth Pits existing and improve it by watering, adding of chemical etc. (Chemical will be measured and paid separately)
(e) Contractor will be responsible for marking of Earth Check date and due date on existing Plate with paint as specified by Engineer-in-Charge.
(f) Contractor will be responsible for cleaning of bushes, grass, sand etc inside and all around upto 1.50 Metre Area of existing Earth Pit with tightening of Strip.
(g) Repair Party will be report every Morning and Evening to JE E/M. | 6,500 | EACH EARTH PIT | - | - |
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.69 MB
BOQ_863975.xls
BOQ • 0.52 MB
GENINSTRCTIONT.pdf
Tender Documents • 2.00 MB
Tender.pdf
Additional Documents • 3.27 MB
CREDIT.pdf
Additional Documents • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .