Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.0 CrAccepted-AOC 195 MAHESH NAGAR AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | ₹4.0 Cr | L1 | Accepted-AOC Being Lowest |
| 2 | L2₹4.1 Cr+₹6.0 L (1.49%)Rejected-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | ₹4.1 Cr+₹6.0 L (1.49%) | L2 | Rejected-Finance Being other than Lowest Bidder |
| 3 | L3₹4.2 Cr+₹14.7 L (3.64%)Rejected-Finance I 910 JAHANGIR PURI NEAR BY ANAND MAYA HOSPITAL NORTH WEST DELHI DELHI 110033 UDYAM DL 06 0040830 | NORTH DELHI | DELHI | 110033 | ₹4.2 Cr+₹14.7 L (3.64%) | L3 | Rejected-Finance Being other than Lowest Bidder |
| 4 | L4₹4.2 Cr+₹18.4 L (4.58%)Rejected-Finance 04 L BLOCK MARKET SECTOR 11 NOIDA 201301 UP GAUTAM BUDHA NAGAR | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201301 | ₹4.2 Cr+₹18.4 L (4.58%) | L4 | Rejected-Finance Being other than Lowest Bidder |
| 5 | L5₹4.3 Cr+₹26.0 L (6.47%)Rejected-Finance 5037 5038 URBAN ESTATE PH 1 PATIALA 147002 PUNJAB | PATIALA | PATIALA | PUNJAB | 147002 | ₹4.3 Cr+₹26.0 L (6.47%) | L5 | Rejected-Finance Being other than Lowest Bidder |
| Sl No | Description | Qty | Unit | M/s Kohli Builders L9 | Raman Electric Trading Co L1 | SATISH AND CO L3 | FRIZO INDIA PVT LTD L6 | GEPS PROJECTS L4 | R D Bansal L2 | Sant Construction Co. L5 | BHARAT ELECTRICAL TRADERS L7 | mayur enterprises L8 | SAGGI ELECTRIC COMPANY L10 | M P TYAGI ENGINEERS AND CONTRACTORS L11 | B D RAIZADA PROJCTS PVT LTD L12 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Disconnecting HT Electric Supply and taking down old existing VCB of any capacity of any description and in any position from the existing indoor/outdoor substation, shifting the VCB to new location not exceeding 10 KM away from the starting point and installation, fixing and commissioning the VCB connecting the incoming and outgoing connections including testing the VCB all as specified and directed.
Note: Quoted rate shall include fixing of VCB in existing strucuture at new location, minor repair of existing platform if any and minor addn/ altn to mounting and connecting structure. | 5 | Each Job | 10,000 ₹50,000 | 5,000 ₹25,000 | 20,000 ₹1,00,000 | 10,000 ₹50,000 | 15,000 ₹75,000 | 1,500 ₹7,500 Lowest | 15,000 ₹75,000 | 5,000 ₹25,000 | 10,000 ₹50,000 | 23,250 ₹1,16,250 | 9,999 ₹49,995 | 9,000 ₹45,000 |
| 2.00 | Supply & Fixing commissioning and testing of modular one side extendible 11 KV 630 Amp, 3 phase,50 Hz , outdoor type, SF 6, insulated Ring Main Unit/HT panel 3 way comprising of 02 Number Load break switch (LBS) and 01 No of Vacuum Circuit Breaker, with all required interlocking for functional and safety considerations as per site requirement incl provn of padlocking, suitable for ambient temp -5 digree C to 50 digree C mounted on MS Channel platform recommended by manufactore, EC grade tinned copper bus bars mounted over epoxy/DMS insulaters, copper flat bus bars, (for earthing metal clad, CB, LBS, MS angle ), Air insulated me+F45tering module, all live parts of the switchboard like bus bars, LBS etc should be enclosed in robotically laser welded single stainless steel tank not less than 2.00 mm thick having IP 67 degree of protection with SF 6 as insulating medium, gas pressure indicator with green and red zone, max leakage rate 0.1 % per year, NRV for fill up of gas, housed in min 2 mm CRCA outer enclosure, grit/shot blasted IP 54 confirming to IEC-62271-1(2017), IS-12729:1988 incl all latest ammendments, painted in polyurethane based powder paint over thermal spary of Zn alloy, Siemens gary shade RAL 7032 confirming to all relevent IS & IEC standards including the following items :- | 1 | Each | 7,70,000 ₹7,70,000 | 7,50,000 ₹7,50,000 | 7,00,000 ₹7,00,000 | 7,30,000 ₹7,30,000 | 7,08,000 ₹7,08,000 | 7,33,000 ₹7,33,000 | 6,65,000 ₹6,65,000 Lowest | 7,40,000 ₹7,40,000 | 7,50,000 ₹7,50,000 | 7,90,500 ₹7,90,500 | 8,99,999 ₹8,99,999 | 8,54,900 ₹8,54,900 |
| 2.01(a) Load break Switch (LBS), HT 11 KV, with itegral earth switch & fuse trip confirming to IEC 60127, IS 9920 and IS 9921 outdoor type 2.0 mm thick CRCA sheet enclosure powder coated, interlocked earth switch with following specification. (i) Rated system voltage 12 KV (ii) Rated current rating 630 Amos. (iii) Nominal system voltage -11 KV, 50 Hz, 3 pole. (iv) One minute power frequency voltage withstand level-28 KV RMS (Min). (v) Impulse voltage withstand level-75 KV peak (min). (vi)Type of insulation -SF6. (vii) Rated short time with stand current 21 KA/3 sec (min). (viii) Rated short circuit making capacity 62.5 KA. (ix) Type of operating mechanisam-Quick make, Quick break mannual spring assisted toggle, (x) Interlocking: to prevent simultaneous switching of earth and main switch, with provn of padlocking in Earth/main position. (b) Vacuum Circuit Breaker : 11 KV, 630 Amps, 3 Phase, 50 Hz, 3 Phase indoor type, totally enclosed/metal clad switch gear, overload earth fault and shortcircuit protection, voltmeter rage (0-15 KV) and Ammeter (0-630 Amp), complete of following specifications mentioned in IS/EC 62271-100 & 200 /IS 13118 : 1991 incl latest amedments /additions. (i) Push buttons for breaker On/OFF. (ii) SCADA complients self powered microprosser based IDMT Relay (3 O/C + 1 E/F) with rechargeble batery with adjustable O/C and E/F element current setting including 1 No Voltage monitoring relay for under voltage /over voltage protection. iii) One minute power frequency voltage withstand level-28 KV RMS (min). (iv) Impulse voltage withstand level-75 KV peak(min). (v) Rated Breaking current :21 KA (min) for 3 s (vi) Rated making current : 62.5 KA. (vii) Mechanical and LED indications fr breaker ON, OFF, Earth, TRIP, spring charged. | |||||||||||||||
| 2.02(viii) Dual core dual ratio current transformer (CT) chamber compressing of 3 Nos, single phase resin cast /ring core CTs of 300/150/5+5 Amps (incomming) and CTs of 200-100/5+5 Amps (outgoing), burden not more than 15 KA accuracy class 0.5 for metering, having class 5 P10 for protection as per IS:2705. (ix) Potential transformer (PT), 3 phase dry type (resin cast) fixed type 11 KV/110 Volts, burden 100 VA, Accuracy class 0.5 with HT & LT HRC fuses/MCB for primery and secondry complete all as specified and direcetd as per IS:3156-01 set. (x) Earthing switch rated for full making capacity with provision for safe & reliable position indicator. (c) Misc Provisions : (i) Volatge indication lamps for all 3 Phases for earth function of RMU. (ii) LED bulb for illumination. (iii) Space heater with termostat. (iv) One set of mechanical indicator for ON/OFF indication for all LBS/circuit breaker/Earth switch, liveline indicator. (v) Go-No-Go indication based on SF 6 gas pressure. (vi) Multifunction meter in all circuit breakers, Voltmeter in balance. | |||||||||||||||
| 3.00 | Supply & Fixing commissioning and testing of modular one side extendible 11 KV 630 Amp, 3 phase,50 Hz , Indoor type, SF 6, insulated Ring Main Unit/HT panel 4 way comprising of 02 Number Load break switch (LBS) and 02 No of Vacuum Circuit Breaker, with all required interlocking for functional and safety considerations as per site requirement incl provn of padlocking, suitable for ambient temp -5 digree C to 50 digree C mounted on MS Channel platform recommended by manufactore, EC grade tinned copper bus bars mounted over epoxy/DMS insulaters, copper flat bus bars, (for earthing metal clad, CB, LBS, MS angle ), Air insulated metering module, all live parts of the switchboard like bus bars, LBS etc should be enclosed in robotically laser welded single stainless steel tank not less than 2.00 mm thick having IP 67 degree of protection with SF 6 as insulating medium, gas pressure indicator with green and red zone, max leakage rate 0.1 % per year, NRV for fill up of gas, housed in min 2 mm CRCA outer enclosure, grit/shot blasted IP 54 confirming to IEC-62271-1(2017), IS-12729:1988 incl all latest ammendments, painted in polyurethane based powder paint over thermal spary of Zn alloy, Siemens gary shade RAL 7032 confirming to all relevent IS & IEC standereds including the following items :- | 2 | Each | 10,35,000 ₹20,70,000 | 10,00,000 ₹20,00,000 | 9,30,000 ₹18,60,000 | 10,00,000 ₹20,00,000 | 9,39,000 ₹18,78,000 | 9,40,000 ₹18,80,000 | 9,00,000 ₹18,00,000 Lowest | 10,00,000 ₹20,00,000 | 10,00,000 ₹20,00,000 | 10,38,500 ₹20,77,000 | 9,99,999 ₹19,99,998 | 11,49,000 ₹22,98,000 |
| 3.01(a) Load break Switch (LBS), HT 11 KV, with itegral earth switch & fuse trip confirming to IEC 60127, IS 9920 and IS 9921 indoor type 2.0 mm thick CRCA sheet enclosure powder coated, interlocked earth switch with following specification. (i) Rated system voltage 12 KV (ii) Rated current rating 630 Amos. (iii) Nominal system voltage -11 KV, 50 Hz, 3 pole. (iv) One minute power frequency voltage withstand level-28 KV RMS (Min). (v) Impulse voltage withstand level-75 KV peak (min). (vi)Type of insulation -SF6. (vii) Rated short time with stand current 21 KA/3 sec (min). (viii) Rated short circuit making capacity 62.5 KA. (ix) Type of operating mechanisam-Quick make, Quick break mannual spring assisted toggle, (x) Interlocking: to prevent simultaneous switching of earth and main switch, with provn of padlocking in Earth/main position. (b) Vacuum Circuit Breaker : 11 KV, 630 Amps, 3 Phase, 50 Hz, 3 Phase indoor type, totally enclosed/metal clad switch gear, overload earth fault and shortcircuit protection, voltmeter rage (0-15 KV) and Ammeter (0-630 Amp), complete of following specifications mentioned in IS/EC 62271-100 & 200 /IS 13118 : 1991 incl latest amedments /additions. (i) Push buttons for breaker On/OFF. (ii) SCADA complients self powered microprosser based IDMT Relay (3 O/C + 1 E/F) with rechargeble batery with adjustable O/C and E/F element current setting including 1 No Voltage monitoring relay for under voltage /over voltage protection. (iii) One minute power frequency voltage withstand level-28 KV RMS (min). (iv) Impulse voltage withstand level-75 KV peak(min). (v) Rated Breaking current :21 KA (min) for 3 s (vi) Rated making current : 62.5 KA. (vii) Mechanical and LED indications fr breaker ON, OFF, Earth, TRIP, spring charged. | |||||||||||||||
| 3.02(viii) Dual core dual ratio current transformer (CT) chamber compressing of 3 Nos, single phase resin cast /ring core CTs of 300/150/5+5 Amps (incomming) and CTs of 200-100/5+5 Amps (outgoing), burden not more than 15 KA accuracy class 0.5 for metering, having class 5 P10 for protection as per IS:2705. (ix) Potential transformer (PT), 3 phase dry type (resin cast) fixed type 11 KV/110 Volts, burden 100 VA, Accuracy class 0.5 with HT & LT HRC fuses/MCB for primery and secondry complete all as specified and direcetd as per IS:3156-01 set. (x) Earthing switch rated for full making capacity with provision for safe & reliable position indicator. (c) Misc Provitions : (i) Volatge indication lamps for all 3 Phases for earth function of RMU. (ii) LED bulb for illumination. (iii) Space heater with termostat. (iv) One set of mechanical indicator for ON/OFF indication for all LBS/circuit breaker/Earth switch, liveline indicator. (v) Go-No-Go indication based on SF 6 gas pressure. (vi) Multifunction meter in all circuit breakers, Voltmeter in balance. | |||||||||||||||
| 4.00 | Supply & Fixing commissioning and testing of modular one side extendible 11 KV 630 Amp, 3 phase,50 Hz , Outdoor type, SF 6, insulated Ring Main Unit/HT panel 4 way comprising of 02 Number Load break switch (LBS) and 02 No of Vacuum Circuit Breaker, with all required interlocking for functional and safety considerations as per site requirement incl provn of padlocking, suitable for ambient temp -5 digree C to 50 digree C mounted on MS Channel platform recommended by manufactore, EC grade tinned copper bus bars mounted over epoxy/DMS insulaters, copper flat bus bars, (for earthing metal clad, CB, LBS, MS angle ), Air insulated metering module, all live parts of the switchboard like bus bars, LBS etc should be enclosed in robotically laser welded single stainless steel tank not less than 2.00 mm thick having IP 67 degree of protection with SF 6 as insulating medium, gas pressure indicator with green and red zone, max leakage rate 0.1 % per year, NRV for fill up of gas, housed in min 2 mm CRCA outer enclosure, grit/shot blasted IP 54 confirming to IEC-62271-1(2017), IS-12729:1988 incl all latest ammendments, painted in polyurethane based powder paint over thermal spary of Zn alloy, Siemens gary shade RAL 7032 confirming to all relevent IS & IEC standereds including the following items :- | 2 | Each | 10,45,000 ₹20,90,000 | 10,00,000 ₹20,00,000 | 9,40,000 ₹18,80,000 | 10,00,000 ₹20,00,000 | 9,45,000 ₹18,90,000 | 10,39,000 ₹20,78,000 | 9,10,000 ₹18,20,000 Lowest | 10,00,000 ₹20,00,000 | 10,00,000 ₹20,00,000 | 10,46,250 ₹20,92,500 | 9,99,999 ₹19,99,998 | 11,49,000 ₹22,98,000 |
| 4.01(a)Load break Switch (LBS), HT 11 KV, with itegral earth switch & fuse trip confirming to IEC 60127, IS 9920 and IS 9921 outdoor type 2.0 mm thick CRCA sheet enclosure powder coated, interlocked earth switch with following specification. (i) Rated system voltage 12 KV (ii) Rated current rating 630 Amos. (iii) Nominal system voltage -11 KV, 50 Hz, 3 pole. (iv) One minute power frequency voltage withstand level-28 KV RMS (Min). (v) Impulse voltage withstand level-75 KV peak (min). (vi)Type of insulation -SF6. (vii) Rated short time with stand current 21 KA/3 sec (min). (viii) Rated short circuit making capacity 62.5 KA. (ix) Type of operating mechanisam-Quick make, Quick break mannual spring assisted toggle, (x) Interlocking: to prevent simultaneous switching of earth and main switch, with provn of padlocking in Earth/main position. (b) Vacuum Circuit Breaker : 11 KV, 630 Amps, 3 Phase, 50 Hz, 3 Phase indoor type, totally enclosed/metal clad switch gear, overload earth fault and shortcircuit protection, voltmeter rage (0-15 KV) and Ammeter (0-630 Amp), complete of following specifications mentioned in IS/EC 62271-100 & 200 /IS 13118 : 1991 incl latest amedments /additions. (i) Push buttons for breaker On/OFF. (ii) SCADA complients self powered microprosser based IDMT Relay (3 O/C + 1 E/F) with rechargeble batery with adjustable O/C and E/F element current setting including 1 No Voltage monitoring relay for under voltage /over voltage protection. (iii) One minute power frequency voltage withstand level-28 KV RMS (min). (iv) Impulse voltage withstand level-75 KV peak(min). (v) Rated Breaking current :21 KA (min) for 3 s (vi) Rated making current : 62.5 KA. (vii) Mechanical and LED indications fr breaker ON, OFF, Earth, TRIP, spring charged. | |||||||||||||||
| 4.02(viii) Dual core dual ratio current transformer (CT) chamber compressing of 3 Nos, single phase resin cast /ring core CTs of 300/150/5+5 Amps (incomming) and CTs of 200-100/5+5 Amps (outgoing), burden not more than 15 KA accuracy class 0.5 for metering, having class 5 P10 for protection as per IS:2705. (ix) Potential transformer (PT), 3 phase dry type (resin cast) fixed type 11 KV/110 Volts, burden 100 VA, Accuracy class 0.5 with HT & LT HRC fuses/MCB for primery and secondry complete all as specified and direcetd as per IS:3156-01 set. (x) Earthing switch rated for full making capacity with provision for safe & reliable position indicator. (c) Misc Provitions : (i) Volatge indication lamps for all 3 Phases for earth function of RMU. (ii) LED bulb for illumination. (iii) Space heater with termostat. (iv) One set of mechanical indicator for ON/OFF indication for all LBS/circuit breaker/Earth switch, liveline indicator. (v) Go-No-Go indication based on SF 6 gas pressure. (vi) Multifunction meter in all circuit breakers, Voltmeter in balance. | |||||||||||||||
Tender Value
₹5.8 Cr
EMD Value
₹6.2 L
Closing Date
3 Oct 2025, 6:00 pmClosed
Cwe AF Gwalior
HQ CWE AF Gwalior PIN 474020
IMPROVEMENT TO ELECTRICAL SYATEM AT AF STN GWALIOR
2025_MES_727724_1
86028
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
GE AF Adm Area
As per tender document
9 documents required · 9 mandatory
₹3,000
GE AF ADM Area
₹6.2 L
Yes
10 Nov 2025
25 Aug 2025
10 Oct 2025
25 Aug 2025
3 Oct 2025
23 Sept 2025
stage.html
html • 0.09 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.47 MB
BOQ_814673.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .