Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.5 LAccepted-AOC 229 CHANDEL MARKET HARJINDER NAGAR KANPUR 208007 | KANPUR | KANPUR | UTTAR PRADESH | 208007 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹21.5 L+₹71,350 (3.42%)Rejected-Finance 67 KAILASH VIHAR TIWARIPUR BAGIA JAJMAU KANPUR 208010 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208010 | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹22.8 L+₹2.0 L (9.39%)Rejected-Finance | L3 | Rejected-Finance Being other than lowest | |
| 4 | L4₹28.4 L+₹7.5 L (36.1%)Rejected-Finance | L4 | Rejected-Finance Being other than lowest | |
| 5 | L5₹31.0 L+₹10.1 L (48.6%)Rejected-Finance 11 82 GROUND FLOOR BLOCK 11 KALYANPURI EAST DELHI DELHI 110091 | EAST DELHI | DELHI | 110091 | L5 | Rejected-Finance Being other than lowest |
Tender Value
₹38 L
EMD Value
₹76,000
Closing Date
28 Apr 2020, 6:00 pmClosed
GE (AF) E/M CHAKERI KANPUR
GE (AF) E/M CHAKERI KANPUR 208008
REPAIR REPLACEMENT AND MAINT OF OLD UNSERVICEABLE LT PANEL AND OTHER CONNECTED WORKS AT TECH AREA AT AFS CHAKERI KANPUR
2020_MES_336825_1
8353/E8
Open Tender
Electrical and Maintenance Works
Item Rate
274 days
GE (AF) E/M CHAKERI KANPUR
As per NIT
8 documents required · 8 mandatory
₹500
GE (AF) E/M CHAKERI
₹76,000
27 May 2020
30 Mar 2020
5 May 2020
30 Mar 2020
28 Apr 2020
14 Apr 2020
Amount
S&F in repair of MCCB 630 Amps 36 KA, 4 Pole, 415V including lugs, nuts, bolts, washers, spacers, etc. and dismantling of old MCCB testing and commissioning complete all as specified and directed. Make MCCB :- L&T / Legrand / ABB/Indo Asian or equivalent
All as per Item No. 1 above but MCCB of capacity 400 Amps 36 KA, 4 Pole, 415V .
All as per Item No. 1 above but MCCB of capacity 250 Amps 36 KA, 4 Pole, 415V.
All as per Item No. 1 above but MCCB of capacity 200 Amps 36 KA, 4 Pole, 415V.
All as per Item No. 1 above but MCCB of capacity 160 Amps 25 KA, 4 Pole, 415V.
All as per Item No. 1 above but MCCB of capacity 125 Amps 25 KA, 4 Pole, 415V
All as per Item No. 1 above but MCCB of capacity 100 Amps 25 KA, 4 Pole, 415V
All as per Item No. 1 above but MCCB of capacity 63 Amps 25 KA, 4 Pole, 415V
All as per Item No. 1 above but MCCB of capacity 32 Amps 25 KA, 4 Pole, 415V
M&L for cleaning and servicing of ACBs of capacity 630-800 Amps, 50 KA, 4 Pole, 415V and other lugs accessories incl. nuts, bolts, washers etc. testing and commissioning complete all as specified and directed.
All as per Item No. 10 above but of capacity 1000 -1250 Amps, 50 KA, 415V, 4 Pole.
S&F in repair of ACB 1250 Amps 50 KA, 4 Pole, 415V including lugs, nuts, bolts, washers, spacers etc. and dismantling of old ACB testing and commissioning complete all as specified and directed. Make of ACB :- L&T / Legrand / ABB or equivalent
All as per Item No. 12 above but ACB of capacity 1000 Amps 50 KA, 4 Pole, 415V
All as per Item No. 12 above but ACB of capacity 800 Amps 50 KA, 4 Pole, 415V
All as per Item No. 12 above but ACB of capacity 630 Amps 50 KA, 4 Pole, 415V
M&L in repair of Digital ammeter flush type 96 sqmm with suitable fixing arrangement and including suitable size of copper wound CTs for easily fixing in existing LT panel including necessary wiring complete all as specified and directed. Make : AE / L&T / Schenider or equivalent as approved by GE
M&L in repair of Digital voltmeter flush type 96 sqmm with suitable fixing arrangement for easily fixing in existing LT panel including necessary wiring complete all as specified and directed. Make : AE / L&T / Schenider or equivalent as approved by GE
M&L in repair of Indicator lamp assembly LED type (RYB) in existing LT panel with suitable wiring complete all as specified and directed. Make : AE / L&T / Schenider or equivalent as approved by GE
M&L for replacement of CTs (current transformer) 250/400/630 Amps indoor type for existing LT panel complete all as specified and directed. Make : AE / L&T / Schenider or equivalent as approved by GE
Repair / Maintenance of LT Panel board by taking shut down, removing of carbon particles, rubbing of heated portion of bus bar and cleaning complete by means of CRC-226 / Petrol tightening of all joints in bus bar, checking of earth and neutral voltage, replacement of u/s nuts / bolts / washers including replacement of corroded glands, lugs, thimbles, hinges, doors locks, door knobs, gaskets etc. and tightening them properly for panels having I/O circuits upto 5 nos complete all as specified and directed.
All as per item no. 20 above but 6-10 no. of circuits.
All as per item no. 20 above but 11-15 no. of circuits.
S&F in repair of copper bus bar as per existing size, type and suitable for LT panel 415 Volt, AC including existing size / type insulator , proper taping / sleeving of bus bar and all accessories incl. nut, bolts, washers etc.complete all as specified and directed.
S&F in repair of aluminium bus bar as per existing size, type and suitable for LT panel 415 Volt, AC including existing size / type insulator , proper taping / sleeving of bus bar and all accessories incl. nut, bolts, washers etc.complete all as specified and directed.
S&F in repair of On Load Change Over on wall / Panel 415 Volts 400 Amps capacity, 4 pole with Sheet steel enclosure complete all as specified and directed. Make - L&T / Havells / Schneider
All as per item no. 25 above but of capacity 200 Amps.
All as per item no. 25 above but of capacity 100 Amps.
All as per item no. 25 above but of capacity 63 Amps.
M&L for testing of old earthing using calibrated earth tester & submitting result to Engr-in-charge. Earthing that shows on higher side results as specified in IS rule and do not show continuity should be replaced with new earthing complete all as specified and directed. Note : (i) Watering of earthing with 2 Buckets (30Ltrs) water mixed with salt (total 5 Kg) shall be carried out one day prior to the testing & the cost of the same shall deemed to be included in quoted unit rate .
M&L for providing the MS plate size of size 200x150 mm of rectangular shape and not less than 1.6 mm thick fixed on angle iron 25x3 mm and 600mm height welded with plate and grouting vertically alongwith earthing pit with PCC block not less than 300x300x300 mm duly painted background with black colour and writing with white colour Earthing Result in Ohm, date of testing, due date for testing complete all as specified and directed.
Earthing complete with GI earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly to ground vertically to a depth not less than 2.25 Mtr below the ground level with top edge of earth plate not less than 1.5 Mtr below normal ground level connected to GI strip 32 x 6 mm size as earthing lead protected with 50 mm dia GI pipe light grade filling around with charcoal dust and salt including excavation, returning, filling of earth and disposal of surplus soil to a distance not exceeding 50 mtr and connected to GI strip by means of GI nuts, bolts and washers strip connected to earth plate and including chamber PCC 1 : 3 : 6 type C1. using 20 mm graded stone aggregate in concrete pit pre-cast RCC 40 mm thick reinforced with 6 mm dia round at the rate of 75 mm C/C both way with 12 mm dia mild steel plain bar lifting handle 2 Nos funnel with wire mesh 20 mm dia GI pipe light grade watering pipe and frame work complete all as shown in electrical plate No. 3 of SSR Part - I including testing complete all as specified and directed. NOTE: GI strip upto 7.5 m length in included in unit rate quoted by contractor and beyond this lengths the same shall be measured & paid separately.
M&L in repair of GI strip 32 x 6 mm by taking down the old existing earth strip any size inside hanger, fixing with proper clamp, saddles, nut bolts , washers etc. properly and connected to equipment or panel complete all as specified and directed.
M&L for removing old paint from the LT panels / Feeder Box / Pole by paint removers, cleaning by scrapping and preparing the surface and applying two coats of synthetic enameled paint of existing colour over a coat of red oxide primer and writing work for panels having I/O circuits upto 5 nos complete all as specified and directed.
M & L in repair of End joint kit Heat shrinkable type suitable for 1100V XLPE under ground cable of size 70-150 sqmm 3.5 core Indoor/Outdoor type complete all as specified and directed. Make: Raychem / 3M / Denson
All as per item No. 36 above but of size 185-240 sqmm 3.5 core.
All as per item No. 36 above but of size 300-400 sqmm 3.5 core.
M & L in repair of Straight through joint kit Heat shrinkable type for 1100V XLPE under ground cable of size 70-150 sqmm 3.5 core complete all as specified and directed. Make: Raychem / 3M / Denson
All as per item No. 39 above but of size 185-240 sqmm 3.5 core.
M&L for cutting of PCC/Hard standing/WBM road not exceeding 30 cm in width & not exceeding 30 cm in depth for passing of LT cable and making good of disturbed surface to match with the existing surfaces by using old and new material upto 15 cm in depth and 15 cm thick PCC (1:3:6) type C-2 (using 40 mm graded stone aggregate) complete all as specified and directed .
Surface dressing 15 cm deep and getting out including cleaning away all grass vegetation saplings, brush wood under grouting, roots & tree and not exceeding 30 cm girth and removing rubbish to a distance of 50 mtr outside the periphery of area complete all as specified and directed.
Cutting / trimming of tree branches and creepers which are touching of overhead lines / pole and disposal of timber complete without dismantling of any item complete all as specified and directed.
M&L for re-routing of LT cables off sizes from 16sqmm to 400sqmm, 3.5/4 core including taking down in ducts/wall/floor/roof/trusses etc and re-alignment of LT cable, cutting/chassing in wall/duct and re-fixing in concealed position as per site requirment, including replacement of luggs, nut, bolts, washers, saddle clamp etc, including making good the disturbed surface to match with the existing surface complete all as specified and directed.
Material and Labour for supply, installation, commissioning and testing in replacement of outdoor type LT panel (CPRI Approved) made out of 3.15 mm thick CRCA sheet metal, single door and suitable MS angle iron base frame, cubical type floor mounted 3 Phase, 4 Wire, 415 Volts properly insulated aluminium bus bar - 04 Nos having capacity 600 amps on phase & 300 Amps neutral, dust and vermin proof, both side open with locking arrangement, danger board plate, duly painted internally and externally with powder coated, fixing in position by provision of platform suitable size built with brick work in CM (1:4), 15 mm thick plastering in CM (1:6) including glands, lugs, thimbles for all incoming and outgoing cable complete all as specified and directed. Incoming / Outgoing: MCCB 400 Amp, 36kA, 415V, 4P - 01 No Make MCCB - L&T / Schneider/ GE Power/ Legrand
Material and Labour for supply, installation, commissioning and testing in replacement of outdoor type LT panel (CPRI Approved) made out of 3.15 mm thick CRCA sheet metal, single door and suitable MS angle iron base frame, cubical type floor mounted 3 Phase, 4 Wire, 415 Volts properly insulated aluminium bus bar - 04 Nos having capacity 400 amps on phase & 200 Amps neutral, dust and vermin proof, both side open with locking arrangement, danger board plate, duly painted internally and externally with powder coated, fixing in position by provision of platform suitable size built with brick work in CM (1:4), 15 mm thick plastering in CM (1:6) including glands, lugs, thimbles for all incoming and outgoing cable complete all as specified and directed. Incoming / Outgoing: MCCB 250 Amp, 36kA, 415V, 4P- 01 No Make MCCB - L&T / Schneider/ GE Power/ Legrand
Material and Labour for supply, installation, commissioning and testing in replacement of outdoor type LT panel (CPRI Approved) made out of 3.15 mm thick CRCA sheet metal, single door and suitable MS angle iron base frame, cubical type floor mounted 3 Phase, 4 Wire, 415 Volts properly insulated aluminium bus bar - 04 Nos having capacity 240 amps on phase & 120 Amps neutral, dust and vermin proof, both side open with locking arrangement, danger board plate, duly painted internally and externally with powder coated, fixing in position by provision of platform suitable size built with brick work in CM (1:4), 15 mm thick plastering in CM (1:6) including glands, lugs, thimbles for all incoming and outgoing cable complete all as specified and directed. Incoming / Outgoing: MCCB 160 Amp, 25kA, 415V, 4P - 01 No Make MCCB - L&T / Schneider/ GE Power/ Legrand
Material and Labour for supply, installation, commissioning and testing in replacement of outdoor type LT panel (CPRI Approved) made out of 3.15 mm thick CRCA sheet metal, single door and suitable MS angle iron base frame, cubical type floor mounted 3 Phase, 4 Wire, 415 Volts properly insulated aluminium bus bar - 04 Nos having capacity 150 amps on phase & 75 Amps neutral, dust and vermin proof, both side open with locking arrangement, danger board plate, duly painted internally and externally with powder coated, fixing in position by provision of platform suitable size built with brick work in CM (1:4), 15 mm thick plastering in CM (1:6) including glands, lugs, thimbles for all incoming and outgoing cable complete all as specified and directed. Incoming / Outgoing: MCCB 100 Amp, 25kA, 415V, 4P - 01 No Make MCCB - L&T / Schneider/ GE Power/ Legrand
Material and Labour for supply, installation,commissioning and testing in replacement outdoor type LT panel (CPRI Approved) made out of 3.15 mm thick CRCA sheet metal, double door and suitable MS angle iron base frame, cubical type floor mounted 3 Phase, 4 Wire, 415 Volts properly insulated aluminium bus bar - 04 Nos having capacity 400 amps on phase & 200 amps on neutral, dust and vermin proof, both side open with locking arrangement comprising of multifunction meters with 3 lines LCD display of voltage, current and frequency and power factor of size 96x96 sqmm, suitable ratio CT, phase indicator-03 Sets, danger board plate, duly painted internally and externally with powder coated, fixing in position by provision of platform suitable size built with brick work in CM (1:4), 15 mm thick plastering in CM (1:6) including glands, lugs, thimbles for all incoming and outgoing cable including dismantling / taking out of suitable sizes for following complete all as specified and directed :- (a) Incoming : (i) MCCB 250 Amp, 36kA, 415V, 4P - 01 No (b) Outgoing : (i) MCCB 63 Amp, 25kA, 415V, 4P- 03 No (ii) MCB - TPN 32 Amps, 415 V - 01 No Make MCCB - L&T / Schneider/ GE Power/ Legrand
Material and Labour for supply, installation,commissioning and testing in replacement of outdoor type LT panel (CPRI Approved) made out of 3.15 mm thick CRCA sheet metal, double door and suitable MS angle iron base frame, cubical type floor mounted 3 Phase, 4 Wire, 415 Volts properly insulated aluminium bus bar - 04 Nos having capacity 400 amps on phase & 200 amps on neutral, dust and vermin proof, both side open with locking arrangement comprising of multifunction meters with 3 lines LCD display of voltage, current and frequency and power factor of size 96x96 sqmm, suitable ratio CT, phase indicator-03 Sets, danger board plate, duly painted internally and externally with powder coated, fixing in position by provision of platform suitable size built with brick work in CM (1:4), 15 mm thick plastering in CM (1:6) including glands, lugs, thimbles for all incoming and outgoing cable including dismantling / taking out of suitable sizes for following complete all as specified and directed :- (a) Incoming : (i) MCCB 250 Amp, 36kA, 415V, 4P - 01 No (b) Outgoing : (i) MCCB 100 Amp, 25kA, 4P, 415V - 03 No Make MCCB - L&T / Schneider/ GE Power/ Legrand
Material and Labour for supply, installation,commissioning and testing in replacement of outdoor type LT panel (CPRI Approved) made out of 3.15 mm thick CRCA sheet metal, double door and suitable MS angle iron base frame, cubical type floor mounted 3 Phase, 4 Wire, 415 Volts properly insulated aluminium bus bar - 04 Nos having capacity 400 amps on phase & 200 amps on neutral, dust and vermin proof, both side open with locking arrangement comprising of multifunction meters with 3 lines LCD display of voltage, current and frequency and power factor of size 96x96 sqmm, suitable ratio CT, phase indicator-03 Sets, danger board plate, duly painted internally and externally with powder coated, fixing in position by provision of platform suitable size built with brick work in CM (1:4), 15 mm thick plastering in CM (1:6) including glands, lugs, thimbles for all incoming and outgoing cable including dismantling / taking out of suitable sizes for following complete all as specified and directed:- (a) Incoming : (i) MCCB 250 Amp, 36kA, 415V, 4P - 01 No (b) Outgoing : (i) MCCB 100 Amp, 25kA, 4P, 415V - 01 No (ii) MCCB 63 Amp, 25kA, 4P, 415V - 01 No Make MCCB - L&T / Schneider/ GE Power/ Legrand
Material and Labour for supply, installation, commissioning and testing in replacement of outdoor type LT panel (CPRI Approved) made out of 3.15 mm thick CRCA sheet metal, double door and suitable MS angle iron base frame, cubical type floor mounted 3 Phase, 4 Wire, 415 Volts properly insulated aluminium bus bar - 04 Nos having capacity 150 amps on phase & 75 amps on neutral, dust and vermin proof, both side open with locking arrangement with danger board plate, duly painted internally and externally with powder coated, fixing in position by provision of platform suitable size built with brick work in CM (1:4), 15 mm thick plastering in CM (1:6) including glands, lugs, thimbles for all incoming and outgoing cable including dismantling / taking out of suitable sizes for following complete all as specified and directed :- (a) Incoming : (i) MCCB 100 Amp, 25kA, 415V, 4P - 01 No (b) Outgoing : (i) MCCB 63 Amp, 25kA, 4P, 415V - 02 No (ii) MCCB 40 Amp, 25kA, 4P, 415V - 03 No Make MCCB - L&T / Schneider/ GE Power/ Legrand
Taking out and reinstalling of LT switchgears / LT Panel / Pole to a distance not more than 5 kms from power house / substation / any place. Taking out/shifting/reinstalling and connecting including casting of suitable PCC foundation etc complete all as specified and directed
M&L for fabrication of door/handles/side panels etc. For unserviceable / damaged / rusted LT panels at AFS Chakeri, Kanpur by using CRCA sheet 3.15 mm thick, serviced with hot gip galvanized seven tank process having ivory white color along with cast iron stand, name plate etc. complete all as specified and directed Note : Material under this item will be paid separately under item 55 to 56.
Supply only CRCA sheet 3.15 mm thick, serviced with hot gip galvanized seven tank process having ivory white color complete all as specified and directed.
Supply only cast iron framed stand including painted in black color over a layer of red oxide primer complete all as specified and directed
Ashirwad Contractor and Supplier
VEE KAY ENTERPRISES
PAWAN COOL CORPORATION
Bharat Sales Corporation
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .