| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.9 LAccepted-Finance 205 IIND PHASE INDUSTRIAL AREA BARMER 344001 | BARMER | BARMER | RAJASTHAN | 344001 | L1 | Accepted-Finance Lowest | |
| 2 | L2₹27.5 L+₹5.6 L (25.8%)Rejected-Finance | L2 | Rejected-Finance Other than lowest |
Tender Value
₹32 L
EMD Value
₹64,000
Closing Date
12 Aug 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF UTARLAI
GARRISON ENGINEER AIR FORCE UTARLAI PB NO 11 BARMER (RAJ) PIN 344001 (CONTACT NO 9982379828 JE (QS C) OFFG AGE (CONTRACTS) GE (AF) UTARLAI)
CERTAIN MAINTENANCE WORKS AND SERVICES AT CHAUHTAN HILL TOP UNDER GE (AF) UTARLAI
2020_MES_362523_1
8126/07/E8 dt 21 Jul 2020
Open Tender
Civil Works
Item Rate
330 days
GE AF UTARLAI
As per NIT
7 documents required · 7 mandatory
₹500
GE AF UTARLAI
₹64,000
Yes
14 Aug 2020
21 Jul 2020
13 Aug 2020
21 Jul 2020
12 Aug 2020
31 Jul 2020
60 days
Amount
M&L for 'B' Check once in Six month or 250 Hrs running whichever is earlier DG sets of capacities as described in Ser Item No. 1.06 to 1.08. Inspection, maintenance and serviceing including alternator, electric panel board connection to DG set etc for smooth functioning and carrying out maintenance as per OEM instructions and as directed by Engr-in-Charge. Note: Items/ Spares including 'B' Check kit, coolent, lubricating oil required shall be measured and paid separately under respective item of BoQ
Replacment of lubricant oil.
Replacing lubricant oil filters element with O rings
Replacing fuel filters element with O rings
Replacing air filter elements with O rings
Replacing coolant.
100 KVA Capacity, Make : Ashok Leyland Location : Near Bore well No-1
320 KVA Capacity, Make :Cummins, Location : Hill Top
15 KVA Capacity, Make : Cummins Location : AF Net Building
Supply only 'B' check kit for DG set of following capacities as mentioned in respective Ser Item No. 2.01 to 2.03. Note : It includes oil filters (1.00 Ltr/0.5 ltr), Diesel filters and air filters inner and outer as recommended by OEM
100 KVA Capacity, Make : Ashok Leyland, Model Location : Near Bore well No-1
320 KVA Capacity, Make :Cummins, Location : Hill Top
15 KVA Capacity, Make : Cummins Location : AF Net Building
Supply only coolent, K cool super plus 50-50 Premix
Supply only Battery water with electrolyte mix
Supply only Engine oil 15 W 40 turbo synthetic superior quality engine oil
Supply only radiator hose pipe set with clamps suitable for DG set of capacity 100 KVA
Supply only radiator hose pipe set with clamps suitable for DG set of capacity 320 KVA
Supply only fan belt set suitable for 100 KVA
Supply only fan belt set suitable for 320 KVA
Supply only fan belt set suitable for 15 KVA
Supply and fixing battery lead with Negative & Positive brass terminals of suitable size and length of each lead complete all as specified and directed
Servicing & repair to self starter of DG set of 15 KVA to100 KVA incl replacement of parts such as washer, nut, bolts, bush, solenoid, rotor etc. assembling and testing complete all as specified and directed by Engr-in-Charge
Supply & Fix in replacement of battery 12 V, 90 AH, maintenance free battery, 12 Volt initially charged with suitable size of copper leads and brass terminals complete all as specified and directed by Engr-in-Charge. Make: Excide/ Amron/ Luminous
M & L for complete checking of AMF panel, finding the fault, servicing complete including replacement of unserviceable spares with necessary wiring and testing complete for manual & Auto operations complete all as specified and directed. (Note:- Items required for replacement will be measured & paid separately under respective item of BoQ)
Supply only in replacement of under and over voltage timing relay of AMF panel as per existing type, make and capacity complete all as specified and directed.
Supply only in replacement of AMF panel timer relay for circuit 230 V AC supply as per existing type, make and capacity complete all as specified and directed.
Supply only in replacement of AMF panel relay card 12 V DC supply for change over as per existing type, make and capacity complete all as specified and directed.
Supply only in replacement of AMF panel relay single with batch 8 pin 230 V AC supply as per existing type, make and capacity complete all as specified and directed.
M&L for replacement of unserviceable contactor 220 V AC supply, 4 pole suitable for the following capacity of DG set AMF panel:-
DG set 320 KVA
DG set 100 KVA
M&L in replacement of Start/ Stop switch with elements of AMF panel of any make and capacity.
M&L in replacement of solenoid switch for use of engine stop of AMF panel of any make and capacity.
M&L in replacement of Volt meter digital type of range 0-500 volts of AMF panel
M&L in replacement of Amp meter digital type of existing make,model and capacity of AMF panel
M&L in replacement of Indicator lamp 230 V AC Supply of AMF panel
M&L in replacement of battery charger 12 V DC SMPS 10 Amp for AMF panel
M&L in replacement of battery charger 24 V DC SMPS 10 Amp for AMF panel
Supply only in replacement of AMF panel control unit as per existing type, make and capacity
Supply and fix in replacement of AMF panel MCCB, 4 pole, 36 KA 200 amp capacity.
M&L earthing complete in replacement as per electrical plate No. 3 of MES SSR Part-I with galvanised steel earth plate electrode 60cmx60cmx6.0mm thick, buried directly vertically in ground in a pit depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less then 1.5 metre below normal ground level connected to and including galvanised iron or steel earth strip 25mm x 4mm by means of bolts, nuts check nuts and washers of galvanised iron or steel. Earthing strip shall be protected by galvanised iron or steel pipe 32mm bore light grade and connected to continuous earth wire on pole / test point. Watering pipe shall be 20 mm bore GI medium grade. The earthing shall be of inclusive of excavation & earth work in any type of soil, charcoal, salt, funnel PCC pit and RCC cover complete all as specified & tested complete.
Supply install and testing outdoor weather proof bus bar chamber of size 120 cm x 40 cm x 40 cm made out of 18 SWG MS sheet having one side open able hinged door shutter with looking arrangement mounted on 40x40x6mm anlge iron frame with legs welded and 04 nos copper bus bar of 400 Amp rating provn of one MCCB TPN 125 Amp 16 KA for controlling Electric supply complete erracted on ground with necessary PCC 1:3:6 type C2 foundation complete bus bar chamber painted with two coats of approved enamel paints over one coat of primer including making cable connection with necessary gland , lugs/thimbles complete all as specified. NOTE: Cost of dismantling/ taking down old unserviceable bus bar chamber shall be included in the quoted rate of this
Supply and fixing in replacement of Street lights LED type 60W energy saving and environmental friendly long life made up of pressure die cast aluminium housing with high power LED as lighting source of IP65 protection as complete including taking down of old unserviceable light fittings complete all as specified and directed by Engr-in-Charge Make: Havells/ Philips /Wipro/Crompton.
M&L for bracket for street light fitting made out of 40 mm bore pipe medium grade ISI marked bent to shape required, fixed with and including MS flat iron clamps, bolts, nuts, washers complete including taking out old UNSV all as directed by Engr -in - charge.
Supply & fix pole mounted junction box SMC type, 3 phase 4 wire for street light including MCB TPN 32 Amp 10 KA - 1 No, MCB SP 6 Amp 10 KA - 1 No and accessories etc of complete all as specified. Make: Sintex or equivalent as approved by GE.
Material and labour for circuit wiring with two runs of single core 2.5 sqmm FR PVC insulated, flexible unsheathed multi stranded copper conductor 1100 V grade with colour code and one run of 1.5 sqmm single core FR PVC insulated, flexible, unsheathed multi stranded copper conductor green colour cable as earth continuity conductor from junction box to street light complete with PVC conduit pipe complet all as specified and directed.
Supplying , fixing and testing in replacement of timer switch 32A 2 pole/230V analog time switch with connecting items fixing on pole/wall/panel all as directed.
Supply and replacement of MCCB 4 pole, 415 V, adjustable type 100 Amps with breaking capacity 25 KA including necessary modification in the panel complete all as specified and as directed.
Supply and replacement of MCCB 4 pole, 415 V, adjustable type 63 Amps with breaking capacity 25 KA including necessary modification in the panel complete all as specified and as directed.
M & L for disconnecting and taking down U/S street light fittings of any type /rating from pole or wall dismantling the same for necessary repair or replacement of u/s spares complete and re fixing, connecting and testing the same complete all as specified and directed Note: (a) Spares/ accessories required for replacement shall be measured and paid separately as supply only under respective items of BoQ (b) T & P required for repair/maintenance such as ladder, vehicle manpower etc, shall be included rate of this item.
Supply only copper ballast suitable for HPSV/MH lamp fitting of the wattages Make Havells / Philips/Crompton Greaves/HPL
Supply only igniter suitable for HPSV lamp fitting of rating 70 watt street light fittings.
Supply only for HPSV lamp of rating 70 watt.
Supply only surge protection device
Supply & Laying in trenches or fixing on wall or passing through pipe or in cable ducts, 1100 volts grade XLPE armoured, electric power cables (heavy duty) with aluminium conductor including taking out old UNSV cables of the following size complete all as specified. Note: The rate quoted inclusive of termination at ends with suitable aluminium lugs where ever required
150 sqmm 3.5 core
120 sq mm 3.5 core
50 sqmm 3.5 core
35 sqmm 3.5 core
16 sqmm 4 core
M & L for LT Cable jointing kit for 1100 Volt (Earthed) grade cable for straight through heat shrink type complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 25 to 50 sqmm complete all as specified.
M & L for LT Cable jointing kit for 1100 Volt (Earthed) grade cable for straight through heat shrink type complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 to 120 Sqmm complete all as specified.
M & L for LT Cable jointing kit for 1100 Volt (Earthed) grade cable for end termination heat shrink type complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 25 to 50 Sqmm complete all as specified.
M & L for LT Cable jointing kit for 1100 Volt (Earthed) grade cable for end termination joint kit heat shrink type complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 to120 Sqmm complete all as specified.
M & L Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified.
S & F in replacement of of LT cable route indicator cast iron of suitable size mountrd on 40X40X3mm angle iron with height of 1.5 Mtr long with LT cable trench including planting in ground with PCC complete all as specified and directed by Engr-in- Charge.
Surface dressing/ cleaning of surrounding Area of two pole structure/ substation and HT/ LT UG cable route area at open area, terrian area including removing of tree branches, small trees plants bushes etc complete all as specified and directed by Engr-in- charge.
Labour and machine required for locating fault in U/G LT cable 1100 Volts by using fault detector machine including transportation and by carried out high pressure test complete all as specified and directed by Engr-in- Charge. Note: required excavation and returning filling work deemed to be included in quoted rates.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.0 sq m on plan and not exceeding 1.5m depth and getting out any type of soil complete all as specified and directed.
Returning filling in including spreading leveling watering and well ramming in layer not exceeding 25 cm as in soil complete all as specified and directed.
Removing excavated material not exceeding 50 m and depostingwhere directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Supplying and Laying stone patti 40-50 mm thick, 25- 30 cm wide abutting each other for cable protection complete all as specified and directed.
Supply and topping up of transformer oil with di-electric strength not less than 50 KV in to the conservator tank/ body tank of the transformer complete all as specified and directed by the Engineer-in-Charge.
Filtration of transformer oil of transformers/ FRMUs installed at various locations to achieve di-electric strength not less than 50 KV at 2.5mm gap as per relevant IS with portable filtration plant, testing of the oil for the di-electric strength before filtration and after filtrationcomplete all as specified and directed by the Engineer-in-Charge.
M&L for preparation of old painted surface, cleaning of oils, lubricants, grease etc, steel tubular, swaged type poles complete of 11.0 mtr long poles with applying 2 coats of aluminium paint including brackets, cross arms clamps including writing pole Nos as before complete all as specified and directed. Location Hill top 2 pole structure.
M&L for preparation of old painted surface, cleaninig of oils, lubricants, grease etc, steel tubular, swaged type poles complete of 9 mtr long poles with applying 2 coats of aluminium paint including brackets, clamps including writing pole Nos as before complete all as specified and directed. Location : Hill top Street light poles.
Supply and replace MCCB 4 pole, 415 V, adjustable type 100 Amps with breaking capacity 25 KA including necessary modification in the panel complete all as specified and as directed. Make: GE/L&T/Havells/Indoasian.
Supply and replace MCCB 4 pole, 415V, adjustable type 63 Amps with breaking capacity 25 KA including necessary modification in the panel complete all as specified and as directed. Make: GE/L&T/Havells/Indoasian.
Supply and lay steel water tubing GI medium grade ISI marked with all fittings laid in trenches /wall etc complete for the following sizes including taking out old uerviceable pipe lines complete all as specified and directed by Engr -in- Charge :-
25 mm bore
50 mm bore
80mm bore
Supply and fix Gun - metal, globe or gate valve ISI marked with iron wheel head, screwed at both ends for iron for the following sizes including taking out old un serviceable gate valves complete all as specified and directed by Engr -in- Charge :-
25 mm bore.
50 mm bore.
Repair to single phase electric mono block pump 2 HP installed in pump house with the following works :- (a) Transportation of burnt motor to civil electric work shop. (b) Dismantling of motor, cutting and taking out burnt stator winding from motor cleaning the stator and rewinding with super enameled copper wire of original gauge / size including tapping varnishing, drying, painting, assembling, to fixing of base plate, nut bolt complete and carrying to site including necessary connection, commissioning and testing for 6 hours on full load (Major spare parts will be measured and paid separately under respective items) Note :- Cost of minor spare parts deemed to have been included in quoted rates by the tendered.
Supply and replacing of following under mentioned worn out U/S parts of centrifugal 2 HP pumping set complete all as specified and directed.
Pump shaft for pumping set incl machining threading making key slot etc.
Gland bush
Guide spider complete with bush
Base Plate with bush including nut bolts
Ball bearing
Repair and servicing of RO water plant 150 ltr per hr installed in ORs Mess and hill top Adam block with the following works :- (a) Replace the UV filter with assembly . (b) Dismantling of RO unit and cleaning RO water storage tank, membrane ,removing inlet/outlet pipe and replace the Chemical tube complete servicing and cleaning the unit all as directed by Engr-in- charge Note :- Cost of unserviceable spare parts deemed to have been included in coated rates
M&L for attending to break down of GI pipe of 50mm dia GI pipe line from Chautan Base UG sump to hill top UG sump including necessary site clearance, excavation, dewatering the water accumulated at site, removal of broken pipe pieces of various lengths through gas cutting/manual cutting as per site requirement and inserting same size of pipe as per existing site design, necessary PCC work including testing for the leakages pipes complete all as specified and directed by Engineer-in-Charge. Note: GI pipe 50mm dia shall be measured and paid separately.
M& L for testing of water for potability and biological analysis etc from the specified lab complete all as specified and directed.
M&L for flat submerssible copper conductor cable multistranded 3 core 6 sqmm 1100 Volt grade with water proof PVC insulated and PVC sheathed flat LT 1100 volts grade including jointing and lowering in tube well with column pipe for star delta connections of pump set complete all as specified and directed.
M & L in repairs for starter delta starter 440 V with suitable relay range fixed on suitable sheet metal enclosure outdoor type covered with canopy dist proof vermin proof, of 3mm thickness and welded with 25x25x5 mm angel iron frame with necessary 1:3:6 PCC foundation for deep borewell submersible pump set complete all as specified and directed.
Supply and fix in repairs prepssure reducer valve (PRV) with connecting accessories suitbale for delivery of pumpset at base to Hill top UG sump pipe line complete all as specified and directed.
M&L repairing of Submersible pump set with multi stage, electric driven 415 volt,50Hz capacity 5 HP including taking up from borewell with colum pipe and lowring down by using of tripod/lowring machine with chain pulley 5 ton capacity complete all as specified and directed. (a) Transportation of burnt motor to civil electric work shop. (b) Dismantling of motor, cutting and taking out burnt stator winding from motor cleaning the stator and rewinding with super enameled copper wire of original gauge / size with suitable for submersible motor, including tapping, Motor end shield, shaft sheild assembling and carrying to site including necessary connection, commissioning and testing on full load (Major spare parts will be measured and paid separately under respective items) (c) The nut bolt/rubber gasket of colum pipe will be replaced by new one. Note :- (i)Cost of minor spare parts deemed to have been included the quoted rates by the tenderer
Supply and replacing of following under mentioned worn out U/S parts of submersible pump set 5 HP for bore well complete all as specified and directed.
Bearing
Strainer
Shaft seal
Supply and fix non return valve cast iron body both end flanged with neoprene ball duly tested and confirming to IS of size 50 mm dia (2'') complete all as specified and directed.
Supply and fix Cast Iron Air Valves with single air Outlets, conforming to IS 14845 of size 50 mm dia bore and fixing up in Cast Iron Water supply mains of size 50 mm dia complete all as specified and directed.
M&L repairing of Submersible pump set multi stage, electric driven 415 volt,50Hz capacity 20 HP including taking up from Under Ground sump and refixing the same after repair by using tripad/ lowring machin ewith chain pulley 5 ton capacity Note: (a) Transportation of burnt motor to civil electric work shop. (b) Dismantling of motor, cutting and taking out burnt stator winding from motor cleaning the stator and rewinding with super enameled copper wire of original gaug suitable for submersible moto,r end shield, shaft sheild assembling and carrying to site including necessary connection, commissioning and testing on full load (Major spare parts will be measured and paid separately under respective items) Note :- The above quoted rates inclusive the cost of minor spare parts.
Supply and replacing of following under mentioned worn out U/S parts of submersible pump set 20 HP for UG sump complete all as specified and directed.
Bush bearing
Strainer
Shaft seal
Outsourcing the Maintenance & Operation service of central type Air Conditioning plant of capacity 22 TR (02 Nos running and 01No standby) installed at Chohtan hill top, round the clock three shift of 08 hrs per day by skilled operator, ITI qualified or well experienced of the trade as approved by GE. The plant should be operated as per laid down procedure of manufacturer instruction and PS clauses. The details of installed machinery at central AC plant are mentioned below:- (i) Air cooled floor mounted waterchiller unit 03 Nos of 22 TR capacity (02 Nos working + 01 stand by).(II) Monoblock centrifugal pump Capacity: 60 USGPM 3 HP with elecrtic motor - 03 Nos (02 Nos running and 01no standby). (iii). Fire dumper-01 Nos (iv) Double skin type floor mounted Air handling unit with electric motor and accessories of capacity CFM - 13600 CFM capacity - 01 Nos (v) LT cable from LT panel to AHU, LT panel to Chiller unit, LT panel to pump set, and LT panel to Humidifier kit. (vi)Floor mounted indoor type LT panel -01 Nos (vii)humidifi cation Kit -01 Nos. Document to be maintained (i) Daily log sheet for AC plant (ii) Daily attendance register Note:- The following items are deemed to be included in the quoted rates by the contractor. (i) Contractor shall be responsible for uninterrupted operation of complete installation execpt in case of electric supply not available in the LT Panel board at AC Plant. (ii) T&P, stationary like log sheets and all consumable items like cotton waste, insulation tape, gland packing, grease, broom required will be provided by the tenderer. (iii) Uniform for operators on duty will be issued by the contractor. (iv) Cleaning of installation shall be the responsibility of the contractor.
M&L for servicing the Air handling units 13500 CFM capacity (central AC), with and including dismantling units, sheet metal parts, blowing out the dust, chemical cleaning by spraying the organic based scale removing agent Vaniklin at the appropriate ratio till removal of complete dust & scale deposits in the fin area of evaporator coil, flushing through for proper air flow across the coil, cleaning of expansion valve; greasing of blower motor, checking of electrical connection, cleaning of air filters, greasing of blower motor, replacement of un serviceable bearings, water drain lines, renewal of rusted sheet metal screws, applying synthetic enamel paint over a coat of primer on the rusted portion and testing & commissioning the unit complete all as specified and as directed by Engineer-in-Charge.
M&L for evacuation of gas from the system, de-scaling the condenser, Chiller unit supply & circulating the decaling solution (hydrochloric acid) with pump, brushing the tubes and wherever required drilling the stubborn scaling without damaging the tubes, replacement of gaskets and unserviceable nuts & bolts assembling back complete testing complete for AC plant of capacity 3x 22 TR- complete all as specified and as directed
Repair and maintenance of thermocole insulation with thermo coal 50 mm thick TF Quality covered with chicken wire mesh , sand cement plaster10 mm CM 1:6 on the top Edge at Supply and return (External Duct) complete all as specified and directed by Engineer-in-charge.
M & L for Refrigerant gas R-407(a) in company sealed cylinder of capacity all as directed by Engr-in-charge.
S&F in replacement of LP sensor 12 volt suitable for Scroll type AC of capacity 3x56.5 TR completes all as specified and directed by Engineer-in-charge. Make: - Danfoss / Indo Foss or equivalent make as approved by GE.
S&F in replacement of HP Sensor 12 Volt suitable for Scroll type AC of capacity 3x56.5 TR completes all as specified and directed by Engineer-in-charge. Make: - Danfoss/Indo Foss or equivalent make as approved by GE.
S&F in replacement of AHU belt of suitable size as per Existing belt complete all as specified and directed by Engineer-in-charge.
Repair and maintenance of thermocole insulation with thermocoal 75 mm thick TF Quality covered with chicken wire mesh , sand cement plaster10 mm CM 1:6 on the top Edge at Supply and return (External Duct) complete all as specified and directed by Engineer-in-charge.
S&F in repairs 3 phase contactor 415 Volt 50 HZ suitable for 3 HP motor coil. Volt make Siemens / L&T / C&S disconnecting & dismantling existing unserviceable contactor complete all as specified and directed.
S&F in repairs relay with timer suitable for 3 HP motor coil including disconnecting & dismantling existing unserviceable contactor complete all as specified and directed.
S&F in Replacement of AHU filter EV-4 model complete all as specified and directed by Engineer-in-charge.
Dismantling of unserviceable centrifugal pump set monoblock single phase volts, up to 3 HP of any model/Make, strip opening and taking out or rotor carefully, cleaning of rotor and stator, taking out burnt stator winding without damage to stator body, rewinding the eclectic motor by super enameled copper conductor (Wire) including providing insulating Mika paper in stator slots, PVC sleeves, varnish the winding complete, assembling the motor including replacement of studs with nuts, testing of motor to its full load capacity at desired RPM/torque after coupling with pump set etc including transportation to civil workshop and alignment in same vice -versa complete all as specified and directed by Engineer-in-Charge.
M&L for preparing old black top surfaces by brushing with wire brushes for removing caked mud etc. seeping with brooms and finaly the surface with gunny bags to remove all loose dirt etc. complete all as specified and directed.
Applying evenly a priming / tack coat with bituminous primer at 05 Kg per 10 Sqm complete all as specified and directed.
M&L for Laying bituminous premix asphiltic semi dense concrete 30mm consiolidated thickness with 5.5% binder content by weight of total mix, rolled and compacted to required camber and gradient complete all as specified and directed.
M&L for painting line, dashes, arrows letters etc on road pavements & the like exc 10 cm width or grith with thermoplastic paint having glass beads by using mechanical means complete all as specified and directed.
Godara Construction and General Suppliers
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .