| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1st₹5.9 LAccepted-AOC SEWA NAGAR COLONY NEAR JOGIO KI DHARAMSHALA BHIWANI 127021 | BHIWANI | BHIWANI | HARYANA | 127021 | 1st | Accepted-AOC ok | |
| 2 | 2nd₹5.9 L+₹7,249 (1.24%)Rejected-Finance HOUSE NO 254P SECTOR 6 ROHTAK OPPOSITE RAJIV GANDHI STADIUM VPO MAKRUALI KALAN 124001 | ROHTAK | ROHTAK | HARYANA | 124001 | 2nd | Rejected-Finance ok | |
| 3 | 3rd₹6.2 L+₹30,132 (5.15%)Rejected-Finance | 3rd | Rejected-Finance ok | |
| 4 | 4th₹6.3 L+₹44,384 (7.58%)Rejected-Finance | 4th | Rejected-Finance ok | |
| 5 | 5th₹6.5 L+₹63,625 (10.9%)Rejected-Finance | 5th | Rejected-Finance ok |
Tender Value
₹6.4 L
EMD Value
₹13,000
Closing Date
26 Feb 2020, 5:00 pmClosed
Executive Engineer
Executive Engineer
SPECIAL REPAIR OF PRIMARY HEALTH CENTRE IN VILLAGE DANODA IN JIND DISTT.
2020_HRY_117561_1
PHC Danoda
Open Tender
Civil Works - Buildings
Item-rate/Agreement basic
165 days
Narwana
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
Yes
Public Work (B and R) Department
₹13,000
29 Oct 2020
7 Feb 2020
26 Feb 2020
7 Feb 2020
26 Feb 2020
7 Feb 2020
7 Feb 2020 - 7 Feb 2020
Amount
Dismantling Brick Work, Tile Masonry or Tile Lining and Tile Terracing b) in cement. (HSR 8.5 (b))
Dismantling cement conglemerate / terrazzo floors 25 mm to 50 mm thick including concrete base. (HSR 8.25)
Scraping a) white wash. (HSR 8.32 (a).
Scraping c) cement plaster. (HSR 8.32 (C).
First class brickwork laid in cement sand mortar 1:4 in first storey upto 4 meters above plinth level. (HSR 11.9)
Tile terracing with one layer of tiles, 22.86 cm X 11.43 cm X 3.81 cm laid dry over a layer of mud mortar including grouting with cement sand mortar 1: 3 and top surface to be left clean.. (HSR 13.14)
Cement concrete 1:2:4 gola 10cm X 10cm quadrant along junction of roof with parapet wall finished smooth, where specially specified. (HSR 13.64)
Providing & fixing PVC Rain water pipe 6 kg. pressure of ISI mark in cement mortar during masonry work (a) 100 mm dia PVC pipe 6 kg. pressure, Supreme, Finolex, Prince (HSR 13.89) (a) 100mm dia PVC pipe 6 kg. pressure.
Providing and fixing PVC Bend ISI mark (a) 100 mm dia PVC Bend, Supreme, Finolex, Prince (HSR 13.90) (a) 100mm dia PVC Bend
Providing and fixing False Ceiling with grooves with 12mm to 15mm thick, 600mm X 600mm best quality mineral fibre tiles of approved make fixed on M.S. Steel runners frame i/c cost of screws angles, cleats, rawel plugs, with taping and painting, etc. complete in all respects as approved by the Engineer-In-Charge. (HSR 13.93)
Base course of floors consisting of 100 mm thick cement concrete 1:8:16 and 100 mm sand or stone filling. (HSR 14.1)
Providing & Fixing Vitrified Tiles 600 x 600 mm of approved make in flooring laid in any pattern as specified over base of 20 mm thick cement coarse sand morter 1.3 and jointed with white cement slurry mixed with pigment to match the shade to tiles. Note:- Tile shall be of premium quality (first quality) of reputed manufacturer like: RAK, NITCO, KAJARIA, SOMANI, JOHNSONS, ORIENTBELL, SIMPOLO. (Double charged tiles shall be used as approved by Engineer in charge. (HSR 14.89). Note:- The Agency to whom the work is alloted will have to produce original bill/voucher for all quantity in token of proof of purchase of material. First Storey
Providing & Fixing Ist quality Ceramic glazed wall tiles confirming to I.S. 15622 (thickness to be specified by the manu-facturer) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-In-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 coarse and jointed with grey cement slurry, including ointing in white cement mixed with pigment of matching shades complete. (b) Size of ceramic Glazed tiles 300 x 450 mm of reputed manufacturer like:- RAK, NITCO, KAJARIA, SOMANI, JOHNSONS, ORIENTBELL, SIMPOLO shall be used as approved by Engineer-in-charge. [HSR 14.92(b)]. Note:- The Agency to whom the work is alloted will have to produce original bill/voucher for all quantity in token of proof of purchase of material. First Storey
12 mm thick cement plaster 1:4. (HSR 15.5)
Painting two coats with synthetic enamel paint in all shades on old wood-work or metallic or plastered or concrete surfaces to give an even shade including rubbing down old paint. (HSR 16.5)
Distempering with washable oil bound distemper (of approved manufacture) two coats over one priming coat on new work. (Note:- First quality paint of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, Drum of paint shall be opened in presence of Engineer-in-charge). (HSR 16.58).
Providing two coats of exterior acrylic emulsion paint. (Note:- First quality paint of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, Drum of paint shall be opened in presence of Engineer-in-charge). [HSR 16.79 (b)].
Factory manufactured paneled and glazed door shutters of commercial hard wood, such as hollock, champ, chikrassy and chaplash, etc., c(non –coniferous timber other than team, conforming to I.S specification no. 1003 kiln seasoned), with 100 mm wide vertical styles, 150 mm wide lock rail, 200 mm wide bottom rail and 100 mm wide other rails, with panelsof 12 mm thick, commercial veneered both side particle board or plywood of B.W.R. grade, hot pressed, including cost of iron hinges, screws, chock/cleats stops and nails etc. complete fixed in position(excluding the cost of any fittings, other than specified above but including labour for fixing the same position. [HSR 17.91 (a)-Note 17.18 (a) 30 mm Thick.
Pressed steel sheet frames (chowkhats) consisting of 2mm thick steel sheet of the specified section, including iron lugs (hold fasts) iron hinges, conforming to P.W.D. specifications, including bolts for fixing stops, locknotch, provision for receiving tower bolts, and finished with one coat of ready mixed paint red lead non-setting primer, of approved quality, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame, and cement concrete 1:3:6 for lugs complete. [HSR 18.34]. (a) door and window frame Size of 89 mm x 59 mm with 40 mm wide signel rebate.
Providing and fixing in position best indian make (as approved by the engineer-in-charge European type water closet suite, syphonic type consisting of- (i) VITREOUS CHINAWARE SYPHONIC SUITE WITH 15 LITRES CAPACITY MATCHING CHINAWARE CISTERN and all internal brass fittings COMPLETE WITH ‘P’ or ‘S’ TRAP with or without vent; (as approved by the Engineer-in-charge). (ii) One piece SEAT AND LID IN HOLLOW BLACK OR WHITE PLASTIC fitted with chromium plated hinges and rubber buffers, (to the approval of the Engineer-in-charge) COMPLETE in all respects INCLUDING CUTTING AND MAKING GOOD THE WALLS AND FLOORS. (b) Double trap syphonic (i) White. [HSR 30.5 (b) (i)].
Providing & Fixing in position best indian make (ordinary) lavatory suites consisting of:- (v) Size 550 mm x 400 mm with one no. tap. [HSR 30.41(iv)].
Providing and fixing in position 15mm i/d C.P. brass bib cocks of best quality (as required by the Engineer-in-charge). [HSR 30.75]. (a) Bib cock long body.
Providing and Fixing HDPE WATER STORAGE TANKS of Sintex, Diplast, O.K. Supreme make with covers/lids marked with IS:12701 on roof top of buildings including cost of hoisting and placing in position, making connections with inlet and outlet pipes, providing overflow and scour provisions with suitable plug on scour pipe including cost of nipples, washers flages for connections in tanks complete in all respects to the satisfaction to the Engineer-in-Charge. [HSR 30.119]. 500 Ltrs. Capacity Water Tank
Recovery:- Credit of Old Brick @ 4.50 Each
Brick Bats @ 450/- P.Cum
Anil Kumar
M/S SHARNYA ENTERPRISES
RAMESH CONTRACTOR
JAIVIR SINGH CONTRACTOR
Rajesh Kumar Contractor
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .