Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.8 LAccepted-AOC GC ROAD ABDUL LATIF ROAD PO TITAGARH KOLKATA 700119 | 24 PARAGANAS NORTH | WEST BENGAL | 700119 | L1 | Accepted-AOC Being a lowest bidder | |
| 2 | L2₹49.3 L+₹2.6 L (5.50%)Rejected-Finance 22 2 BAKRAHAT ROAD THAKURPUKUR KOLKATA 700063 | KOLKATA | KOLKATA | WEST BENGAL | 700063 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹49.8 L+₹3.0 L (6.48%)Rejected-Finance 44B CIRCULAR GARDEN REACH ROAD KOLKATA 700 023 | KOLKATA | WEST BENGAL | 700023 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹50.2 L+₹3.4 L (7.29%)Rejected-Finance 3 IBRAHIM ROAD KHIDDERPORE KOLKATA 700023 | KOLKATA | WEST BENGAL | 700023 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹50.7 L+₹3.9 L (8.38%)Rejected-Finance 10 1 GROUND FLOOR WEST GHOSH PARA JAGATDAL JAGATDAL JAGATDAL NORTH 24 PARGANAS WEST BENGAL 743125 | 24 PARAGANAS NORTH | WEST BENGAL | 743125 | L5 | Rejected-Finance Other than lowest |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
17 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (FW) Kolkata
D9 Commissariat Road Hastings Kolkata 700022
COMPREHENSIVE REPAIR/MAINTENANCE OF SUMMER COOLING APPLIANCES OF FORT WILLIAM AND REPAIR/MAINTENANCE OF MISC ELECTRICAL SERVICES OF CERTAIN OTM HQ BLDG INSIDE FORT WILLIAM UNDER GE (FW) KOLKATA
2021_MES_490538_1
8802/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
GE (FW) Kolkata
Ref tender documents
6 documents required · 6 mandatory
₹500
GE (FW) Kolkata
₹90,000
20 Jan 2022
26 Nov 2021
18 Dec 2021
26 Nov 2021
17 Dec 2021
10 Dec 2021
60 days
Amount
SCHEDULE 'A' PART-I (INT ELECTRIFICATION WORKS) Taking down copper/ aluminium point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceilling roses, pendants, regulators, sockets etc excluding light fitting for reuse or removing from site and making good disturbed surface of walls, floors etc.complete all as specified and directed.
Taking down of Old MCB DB any type any size including MCCB/RCCB/MCBs and disconnecting the serviceable MCBs and keeping in safe custody for reuse at site or removal from site complete all as specified and directed.
Taking down of old Submain wiring any type including batten/ conduit/ casing at any indicated situation complete all as specified and directed.
M&L for surface type point wiring with 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC casing capping medium duty complete with all fittings and accessories, fixed to walls/ceiling, including mild steel terminal boxes 1.25 mm thick conforming to IS-5133 (Part-I) with 3.0 mm thick plastic laminated sheet top cover (ISI Marked) for mounting switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly, for one light point /bell point/ceiling fan/exhaust fan point controlled by one way switch complete all as specified and directed.
All as per item No. 04 above but for one 5 amps switch socket outlet on same board controlled by another switch, complete all as specified and directed (surface type point wiring with terminal box).
All as per item No. 04 above but for one 5 amps switch socket combination on independent board, complete all as specified and directed (surface type point wiring with terminal box).
All as per item No. 04 above but using 2.5 sqmm single core multi stranded copper conductor FRLS-H PVC insulated and unsheathed, cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with and incl 2.5 sqmm green FRLS PVC insulated and unsheathed, copper conductor as continuous earth wire with lugs complete all as specified and directed (surface type point wiring with terminal box).
M&L for concealed type point wiring with 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC conduit complete with all fittings and accessories, fixed to walls/ceiling, including mild steel terminal boxes 1.25 mm thick conforming to IS-5133 (Part-I) with 3.0 mm thick plastic laminated sheet top cover (ISI Marked) for mounting switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly, for one light point /bell point/ ceiling fan/exhaust fan point controlled by one way switch complete all as specified and directed. (NOTES: - (i) Where tube light fitting is to be fitted/suspended, CI Circular boxes shall be provided with the PVC Pipes in the ceiling & the unit rate shall be deemed to be included for the same. (ii) Cost of cutting chases for concealed wiring shall be deemed to be inclusive in the quoted rates. No claim in this regard shall be entertained at a later stage)
All as per item No. 08 above but for one 5 amps switch socket outlet on same board controlled by another switch, complete all as specified and directed (concealed type point wiring with terminal box).
All as per item No. 08 above but for one 5 amps switch socket combination on independent board, complete all as specified and directed (concealed type point wiring with terminal box).
All as per item No. 08 above but using 2.5 sqmm single core multi stranded copper conductor FRLS-H PVC insulated and unsheathed, cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with and incl 2.5 sqmm green FRLS-H PVC insulated and unsheathed, copper conductor as continuous earth wire with lugs complete all as specified and directed (concealed type point wiring with terminal box).
Materials and Labour for surface type point wiring with 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC casing capping complete with all fittings and accessories, (except terminal box and laminate cover), fixed to walls/ceiling, for mounting MODULAR TYPE switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly for One light point or one fan point or bell point controlled by one switch or bell push complete all as specified and directed. (NOTE :- Quoted rate shall be exclusive of the cost of terminal box & laminate cover which shall be measured seperately.
All as per item No. 12 above but for one 5 amps switch socket outlet on same board controlled by another switch, complete all as specified and directed (surface type point wiring without terminal box).
All as per item No. 12 above but for one 5 amps switch socket combination on independent board, complete all as specified and directed (surface type point wiring without terminal box).
All as per item No 12 above but using 2.50 Sq. mm (nominal area) FRLS PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core for line conductor and 2.50 Sq. mm (nominal area) FRLS PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core for earth continuty wire for one 15/16 amp multi socket out let independent (surface type point wiring without terminal box).
M&L for concealed type point wiring with 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and incl PVC conduit complete with all fittings and accessories (except terminal box and laminate cover), fixed to walls/ceiling, for mounting MODULAR TYPE switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly for One light point or one fan point or bell point controlled by one switch or bell push complete all as specified and directed. (NOTE :- (i) Where tube light fitting is to be fitted/ suspended, CI Circular boxes shall be provided with the PVC Pipes in the ceiling & the unit rate shall be deemed to be included for the same. (ii) Quoted rate shall be exclusive of the cost of terminal box & laminate cover which shall be measured seperately. (iii) Cost of cutting chases for concealed wiring shall be deemed to be inclusive in the quoted rates. No claim in this regard shall be entertained at a later stage)
All as per item No 16 here-in-before but for one 5 pin 5/6 amps multisocket outlet point in independent board (concealed wiring) (except terminal box and laminate cover), fixed to walls/ceiling, for mounting MODULAR TYPE switches
All as per item No 16 here-in-before but for one 5 pin 5/6 amp socket out let point in the same switch board of light points (except terminal box and laminate cover), fixed to walls/ceiling, for mounting MODULAR TYPE switches
All as per item No 16 above but using 2.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core for line conductor and 2.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core for earth continuty wire for one 15/16 amp multi socket out let independent. (concealed wiring) (except terminal box and laminate cover), fixed to walls/ceiling, for mounting MODULAR TYPE switches
Materials and Labour for concealed type point wiring with 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in existing PVC conduit complete with all fittings and accessories, fixed to walls/ceiling, including mild steel terminal boxes 1.25 mm thick conforming to IS-5133 (Part-I) with 3.0 mm thick plastic laminated sheet top cover (ISI Marked) for mounting switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly, for one light point /bell point/ ceiling fan/exhaust fan point controlled by one way switch complete all as specified and directed. (NOTE: Wiring shall be done in existing conduit. Quoted rate shall be excusive of the cost of conduit)
All as per item No. 20 above but for one 5 amps switch socket combination on independent board, complete all as specified and directed (concealed type point wiring with terminal box in existing conduit).
All as per item No. 20 above but using 2.5 sqmm single core multi stranded copper conductor FRLS-H PVC insulated and unsheathed, cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with and incl 2.5 sqmm green FRLS-H PVC insulated and unsheathed, copper conductor as continuous earth wire with lugs complete all as specified and directed (concealed type point wiring with terminal box in existing conduit).
PIANO SWITCH, 5/6 AMPS, SINGLE POLE, 240 VOLTS
S & F new Switch piano, flush type, one way
Re-fixing of switch piano, any type (retrieved from taking down of point wiring)
BELL PUSH, 5/6 AMPS, 240 VOLTS
S&F new Bell push, flush type
Re-fixing of bell push, any type (retrieved from taking down of point wiring)
SOCKET OUTLET, 5/6 AMPS, 240 VOLTS
S & F new socket outlet, 2 in 1, 3 pin, flush type (non-shuttered)
Re-fixing of socket outlet, 5/6 Amps any type (retrieved from taking down of point wiring)
SWITCH SOCKET COMBINATION OUTLET, 5/6 AMPS, 240 VOLTS
S&F new switch socket combination outlet, 2-in-1, 3 pin, flush type (non-shuttered)
Re-fixing of switch socket combination outlet, any type (retrieved from taking down of point wiring)
PIANO SWITCH, 15/16 AMPS, SINGLE POLE, 240 VOLTS
S & F new Switch piano, flush type, one way
Re-fixing of switch piano, any type (retrieved from taking down of point wiring)
SOCKET OUTLET, 6 IN 1, 3 PIN, 6/16 AMPS,
S & F new socket outlet, flush type (non-shuttered)
Re-fixing of socket outlet, 6/16 Amps any type (retrieved from taking down of point wiring)
SWITCH SOCKET COMBINATION OUTLET, 6 IN 1, 3 PIN, 6/16 AMPS,
S & F new switch socket combination outlet, flush type (non-shuttered)
Re-fixing of switch socket combination outlet, 6/16 Amps any type (retrieved from taking down of point wiring)
CALL BELL/BUZZER, AC 230/240 VOLTS, SINGLE POLE
S&F new Call bell, musical type
S&F new Call bell, ding dong type
Re-fixing of Call bell, any type (retrieved from taking down of point wiring)
Re-fixing of electric call bell, ding donmg type (retrieved from taking down of point wiring)
CEILING ROSE, THREE TERMINALS, 240 VOLTS
S&F new Ceiling rose, surface type
Re-fixing of ceiling rose, any type (retrieved from taking down of point wiring)
FAN REGULATOR, STEPPED TYPE, 5 SPEED CONTROL, 230/240 VOLTS
S&F stepped type electronic fan regulator, flush type
Re-fixing of fan regulator, any type (retrieved from taking down of point wiring)
LAMP HOLDER, PVC/POLYCARBONATE BODY
S&F lamp holder with back plate suitable for batten/pendant fittings or to be mounted on walls
Re-fixing of lamp holder, any type (retrieved from taking down of point wiring)
MODULAR SWITCH, 5/6 AMPS, 1 MODULE, ONE WAY
S & F Modular Switch 1 way 6 A, 1 module
Re-fixing of modular switch, 5/6 Amps, 1 module (retrieved from taking down of point wiring)
MODULAR SWITCH, 16 AMPS, 1 MODULE, ONE WAY
S & F Modular Switch 1 way 16 A, 1 module
Re-fixing of modular switch, 16 Amps, 1 module (retrieved from taking down of point wiring)
MODULAR SOCKET, 6 AMPS, 2 MODULE
S & F Modular Socket 6 A, 2/3 pin combined 2 module
Re-fixing of modular socket, 6 Amps, 2 module (retrieved from taking down of point wiring)
MODULAR SOCKET, 16 AMPS, 2 MODULE
S & F Modular Socket 6 A/ 16 A, 2/3 pin combined 2 module
Re-fixing of modular socket, 6 A/ 16 A, 2/3 pin combined 2 module (retrieved from taking down of point wiring)
MODULAR FAN REGULATOR
S & F Modular Fan step regulator, 120 watt, 2 module
Re-fixing of modular Fan step regulator, 120 watt, 2 module (retrieved from taking down of point wiring)
MODULAR BELL PUSH
S & F Modular Bell push 6A, 1 module
Re-fixing of modular Bell push 6A, 1 module (retrieved from taking down of point wiring)
MODULAR BLANKING PLATE
S & F Modular Blank plate, 1 module
Re-fixing of modular Blank plate, 1 module (retrieved from taking down of point wiring)
MODULAR MOTOR STARTER SWITCH
S & F 25 Amps motor starter switch, modular type
MODULAR TYPE COVER PLATE WITH FRAME
S&F Modular White cover plate with frame 1 module
S&F Modular White cover plate with frame 2 module
S&F Modular White cover plate with frame 3 module
S&F Modular White cover plate with frame 4 module
S&F Modular White cover plate with frame 6 module
S&F Modular White cover plate with frame 8 module
S&F Modular White cover plate with frame 12 module
MODULAR TYPE METAL FLUSH BOX
S & F Modular type Metal Flush box 1/2 module
S & F Modular type Metal Flush box 3 module
S & F Modular type Metal Flush box 4 module
S & F Modular type Metal Flush box 6 module
S & F Modular type Metal Flush box 8 module
S & F Modular type Metal Flush box 12 module
M&L for sub main wiring with 4 run of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10.0 sqmm alongwith one run of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10.0 sqmm as earth continuity conductor drawn through and including PVC casing-caping of suitable size, surface type complete all as specified and directed. (NOTE : Five runs of single core 10.0 sqmm cable & one run of PVC casing capping shall be measured as one unit)
All as per Srl. Item No. 44 above but with two runs of 6.0 Sqmm cable and one run of 6.0 Sqmm as earth continuity conductor in PVC casing capping (NOTE : Three runs of single core 6.0 sqmm cable & one run of PVC casing capping shall be measured as one unit)
All as per Srl. Item No. 44 above but with two runs of 4.0 Sqmm cable and one run of 4.0 Sqmm as earth continuity conductor in PVC casing capping (NOTE : Three runs of single core 4.0 sqmm cable & one run of PVC casing capping shall be measured as one unit)
All as per Srl. Item No. 44 above but with two runs of 2.5 Sqmm cable and one run of 2.5 Sqmm as earth continuity conductor in PVC casing capping (NOTE : Three runs of single core 2.5 sqmm cable & one run of PVC casing capping shall be measured as one unit)
S&F in repairs surface mounted LED luminaire, 1 X 20 Watt in aluminium housing, operating voltage 180-270 V, with acrylic/polycarbonate difuser & integrated constant current electronic driver complete with all other accessories internally prewired and including connecting up with three core flexible copper wire of suitable size complete all as specified and directed. complying with the following specifications:- (a) minimum efficacy 110 lumen/watt (b) CRI not less than 80, (c) THD < 20% (c) having in built short circuit and surge protection (d) colour temperature not less than 5700 degree K (e) life not less than 25000 hours of operation
-ditto- as per Item No. 48 but of 1 X 9/10 Watt capacity in polycarbonate housing with lumen output not less than 105 lumen per watt
S&F in repairs recess mounted LED luminaire, of size 300 mm x 1200 mm, in powder coated CRCA housing , having glare free diffuser, operating voltage 180-270V, with constant current electronic driver complete with all accessories with and including 36 Watt LED and including all accessories, mounting frame etc and connecting up with three core flexible copper conductor wire of adequate size complete all as specified and directed and complying with the following specifications:- (a) minimum efficacy 110 lumen/watt (b) CRI not less than 80, (c) THD < 20% (c) having in built short circuit and surge protection (d) colour temperature not less than 5700 degree K (e) life not less than 25000 hours of operation (f) Weather protection: IP20
All as per Item No. 50 above, but 36 Watt recess mounted LED luminaire, of size 600 mm x 600 mm complete
All as per Item No. 50 above, but 30 Watt recess mounted LED luminaire, of size 600 mm x 600 mm complete
All as per Item No. 50 above, but 36 Watt surface mounted LED luminaire, of size 600 mm x 600 mm complete
Supply and fixing in repairs suspended LED light fitting, 1X28 Watts, 4 feet long, in aluminium extruded housing with and including rod 4 feet long suitable for single phase 230 Volts, 50 Hz AC supply complete with all accessories internally prewired and including connecting up with three core flexible copper conductor cable of size 1.5 sqmm (nominal area) and OEM suspension system complete all as specified and directed. (MAKE : BAJAJ, Cat No: BPCS 28W LED 4F D WH /HALONIX, Cat No: HLL-R03-28-CW-TZ / CROMPTON, Cat No: CCP-121-28-57-SL-NWH or equivalent model in other makes specified in tender)
NOTE FOR ITEM NO. 48 to 54 :- (1) List of approved makes has been provided in particular specifications. Contractor shall ensure that luminaire provided comply with the aforesaid specifications. No claim shall be entertained during currency of work. (2) Contractor has to furnish a replacement warranty of 02 years for LED light fittings complete incl lamps from the date of completion of work. The product will be replaced free of cost in following cases :- (a) Manufacturing Defects. (b) Failure due to mechanical and electrical impact. (c) Drop in lumen (or lux at 1 metre) below 90% of claimed value of lumen (or lux at 1 metre) of the LED/luminaire. (d) Decision of GE in this regard shall be final and binding. (3) All LED/luminaire shall meet the provision laid down in IS-16101, 16102 Part-I/II, 16103 Part-I, 16104, 16105, 16106, 16108/2012 and 15885 Part-II/Section 13. (4) The contractor shall submit the LM-80 and LM-79 test report (except decorative fitttings) as specified in Particular Specifications.
S&F TPN DB, IP 43 protection, double door (premium quality), 415 volts, 4 way (8+12), with 100 Amps copper bus bar for each phase complete all as specified and directed. (MAKE : L&T, Cat No. DBTPN004DD / LEGRAND, Cat No: 507670 / SCHNEIDER, Cat No. A9HTND04 / ABB, Cat No: E-SHDB M4 / PANASONIC, Cat No: BQS 304H / HAGER, Cat No: VYT04DH)
All as per Item No. 70 above 4 Way (8+12) TPN DB (normal quality) complete all as specified and directed. (MAKE : C&S, Cat No: CSDBTPNHPDD04 /BCH, Cat No: BCHHTPNDD04W / INDO ASIAN, Cat No: 811841 / HAVELLS, Cat No: DHDPTHODRW04 / HPL, Cat No: MDBTDD04)
S&F SPN DB, IP 43 protection, double door (Premium Quality), 240 volts, 4 way, with 100 Amps copper Bus Bar complete all as specified and directed. (MAKE : L&T, Cat No. DBSPN004DD / LEGRAND, Cat No: 507610 / ABB, Cat No. E-SHC M4 / SCHNEIDER, Cat No. NBKRENSNDD04 / HAGER, Cat No: VYS04D)
All as per Item No. 57 above 4 Way SPN DB (normal quality) complete all as specified and directed. (MAKE : C&S, Cat No; CSDBSPNPDD04 / BCH, Cat No: BCHSPNDD04W / HPL, Cat No: MDBDD04 / HAVELLS, Cat No: DHDPSHODRW04 / INDO ASIAN, Cat No: 811824)
S&F Double Door, Sheet Metal Enclosure for DBs (Premium Quality), for mounting of MCB for 240 Volts, 8 way, with 100 Amps rated copper bus bar, Single Pole & Neutral, complete all as specified and directed. (MAKE : L&T, Cat No. DBSPN008DD / LEGRAND, Cat No: 507611 /ABB, Cat No. E-SHC M 8 / SCHNEIDER, Cat No. A9HSND08 / HAGER, Cat No: VYS08D)
All as per Item No. 59 above 8 Way SPN DB (normal quality) complete all as specified and directed. (MAKE : C&S, Cat No: CSDBSPNPDD08 / BCH, Cat No: BCHSPNDD08W / HPL, Cat No: MDBDD08 / HAVELLS, Cat No: DHDPSHODRW08 / INDO ASIAN, Cat No: 811807)
NOTE FOR ITEM NO. 55 to 60 :- (1) Incoming MCCB/RCCB/MCB and outgoing MCBs shall be measured and paid seperately as "Supply Only". (2) Quoted rate is deemed to be inclusive of blanking plate for slots remaining blank after fixing of MCBs. (3) DB, MCCB, RCCB & MCB shall be of the same manufacturer.
S&F MCB (premium quality), 'C' series, TPN, 415 volts, 63 Amps, breaking capacity 10KA complete all as specified and directed. (MAKE : L&T / LEGRAND / SCHNEIDER / ABB / PANASONIC / HAGER)
S&F MCB (normal quality), 'C' series, TPN, 415 volts, 63 Amps, breaking capacity 10KA complete all as specified and directed. (MAKE : C&S / BCH / HPL / HAVELLS / INDO ASIAN)
S&F MCB (premium quality), 'C' series, SPN, 32 Amps, breaking capacity 10KA complete all as specified and directed. (MAKE : L&T / LEGRAND / SCHNEIDER / ABB / PANASONIC / HAGER)
S&F MCB (normal quality), 'C' series, SPN, 32 Amps, breaking capacity 10KA complete all as specified and directed. (MAKE : C&S / BCH / HPL / HAVELLS / INDO ASIAN)
S&F MCB (Premium Quality), 'C' series, single pole, 6 to 32 Amps, breaking capacity 10KA complete all as specified and directed. (MAKE : L&T / LEGRAND / SCHNEIDER / ABB / PANASONIC / HAGER)
S&F MCB (normal quality), 'C' series, single pole, 6 to 32 Amps, breaking capacity 10KA complete all as specified and directed. (MAKE : C&S / BCH / HPL / HAVELLS / INDO ASIAN)
S&F in repair MODULAR MCB protected power unit with one 25 Amps socket with 3 pin plug top and including 01 No MCB, DP, and starter 25 Amps ratings with six module plate and flush metal GI box and electrically connected complete all as specified and directed. (MAKE : HAVELLS, Cat No. DHDUCDP0253025 / NORTH WEST, Cat No: ACPU6M-BT or equivalent model in ABB / CRABTREE / HAGER / SCHNEIDER / LEGRAND) (NOTE : Enclosure & MCB shall be same manufacturer. Cost of MCB is deemed to be included in the quoted rate)
S&F in repairs single pole enclosure with two pin and earth plug and socket complete with one SP MCB, 20 Amps, 'C' Curve, 10 KA including all accesories complete all as specified and directed. (MAKE OF ENCLOSURE: LEGRAND, Cat No. 5078 10 / L&T, Cat No. DBMPS120SD / SCHNEIDER, Cat No: A9HMS220 / ABB, Cat No. NSYN8690SGKSP20 / C&S, Cat No: CSDBPSSPN020 / BCH, Cat No: BCHPSDBSPN20 / HPL, Cat No: MDBSP20 / HAGER, Cat No: VYA220Cor equivalent model in Havells / Indo Asian ) (NOTE : Enclosure & MCB shall be same manufacturer. Cost of MCB is deemed to be included in the quoted rate)
S&F in repairs PVC casing/caping of size 25 mm with all accessories all as directed by Engr-in- charge .
S&F in repairs PVC casing/caping of size 20 mm with all accessories all as directed by Engr-in- charge .
S&F in repair LED driver for 2'x2' LED ceiling light fitting 230 Volt 30 watt - 40 watt complete all as specified and as directed.
S&F in repair LED driver for LED strip light, 230 Volt 5 W complete all as specified and as directed.
S&F in repair PVC cable tray of size 100 X 100 mm, 16 gauge thickness with all accessories such as clamps, screws etc complete all as specified and directed.
Repair/maintanance of ceiling fan of any sweep and any height by replacing unserviceable capacitor/ tightening the loose connections if any including testing complete all as directed. (Note: Capacitor of required capacity will be measured & paid under relavent item here-in-after)
Taking down of AC ceiling fan of any sweep & any height and opening the fan and oiling, greasing, rewinding coil and replacement of unserviceable accessories and servicing, complete overhauling and re-assembling and testing complete by hanging in position as directed.
Taking down exhaust fan, any sweep, opening the fan and oiling, greasing, rewinding coil and replacement of unserviceable accessories and servicing, complete overhauling and re-assembling, fixing in position and testing complete all as specified and as directed.
Taking down wall mounted fan, any sweep, opening the fan and oiling, greasing, rewinding coil and replacement of unserviceable accessories and servicing, complete overhauling and re-assembling, fixing in position and testing complete all as specified and directed.
Supply only capacitor (PVC body) of capacity 4/6 mfd
Supply only capacitor (PVC body) of capacity 2.5 mfd
Supply only capacitor (PVC body) of capacity 3.15 mfd
M&L for cutting chases in brick walls, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landing, steps, cills, sunshades, shelves, lintels etc and cutting chases for concealed water tubing or concealed water tubing or concealed conduit wiring etc and making good, cutting not exc 10 cm girth complete all as specified and directed.
Materials and Labour for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge earth plate at a depth not less than 1.5M below normal ground level connected to galvanized steel earth wire 4 mm dia (upto 7.5 metres) by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 45 cm x 45 cm x 5 cm reinforced with 8 mm dia. TMT bars @ 150 mm centre to centre both ways, with one handle for lifting made out of 8 mm dia MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 40 mm bore galvanized steel tubing medium grade for protection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing and dismantling of existing unsv earthing complete all as shown in Figure 15A of IS 3043 :1987, complete all as specified and directed.
SCHEDULE 'A' PART-II (EXT ELECTRIFICATION WORKS) S&F in repair galvanised steel tube, 50 mm bore, medium grade, fixed on roof for air termination rod complete all as specified and directed.
Demolition of cement concrete (un-reinforced), of any description and in any position complete all as specified and directed.
S&F in repair air termination, single pointed copper rod, 12 mm dia and 300 mm long, fixed on GI pipes with earthing strips for earth coductivity to ground complete all as specified and directed. (NOTE: GI pipe & earthing strip shall be measured and paid seperately)
M&L for Cement Concrete type B-1, (1:2:4) using 20mm graded crushed stone aggregate in copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed including use and waste formwork (straight or curved) complete all as specified and as directed.
S&F in repair test point terminal block, made of gun metal or phosporous beonze of size 75 mm X 75 mm X 25mm, drilled and screwed including 3 Nos, 8 mm dia and 25 mm long hex screws complete all as specified and directed.
S&F in repair copper strip 20 mm X 3.15 mm, fixed on 75 mm size porcelain insulators at one metre internal with clamps, screws etc for roof conductors and down conductors above ground complete all as specified and directed. (NOTE: Porcelain insulator shall be measured and paid seperately)
S&F porcelain insulator of size 75 mm with fixing arrangement complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge earth plate at a depth not less than 1.5M below normal ground level connected to galvanized iron strip 32 X 6 mm (upto 7.5 metres) by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 45 cm x 45 cm x 5 cm reinforced with 8 mm dia. TMT bars @ 150 mm centre to centre both ways, with one handle for lifting made out of 8 mm dia MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 40 mm bore galvanized steel tubing medium grade for protection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing and dismantling of existing unsv earthing complete all as shown in Figure 15A of IS 3043 :1987, complete all as specified and directed.
Supply, installation, testing and commissioning of maintenance free chemical earthing station using 17.2 mm dia, 3000 mm long high tensile low carbon steel circular rod, molecularly bonded with copper on outer surface (minimum copper bonding thickness of 250 microns) meeting the requirements of Underwriters Laboratories (UL) 467-2007 or latest, with 250 mm long copper strip of size 50 x 6 mm, exothermally welded on top of electrode complete including augering (boring) 100-125 mm dia hole as required for electrode in any type of soil and back filling with & incl carbon based ground enhancing compound (GEC) compound (with minimum qty 25 Kg per electrode) conforming to IEEE/BS standards complete all as specified and directed. (NOTE :- 1) The acceptable earth resistance at earth busbar/test point shall not be more than 01 Ohm. At certain locations, it may not be possible to achieve earth resistance of < 01 Ohm with one electrode/pit due to higher soil resistivity. In such cases, provision of loop earthing consisiting of more than one earth electrode pits shall be done. The number of pits required shall be decided based on the resistivity of soil and resistance achieved for the earth pits already installed. The distance between two successive earth electrodes shall not be less than 3 metres. The procedure mentioned below for one earth pit shall be repeated for other earth pits. Additional earth electrode pits and loop conductor shall be measured and paid seperately under respective items. 2) The work shall be carried out by authorised trained rep of the OEM/skilled person certified by GE.
S&F in repair MCCB, 4 pole, 36 KA, with microprocessor release, 400 Amps, Ics=100% of Icu, 415 Volts AC with all accessories complete all as specified and directed. (Make: L&T, Cat No: CM93003OOOOX1 / LEGRAND, Cat No: 6699 07 / C&S, Cat No: CSE3N400ETM4P-400A / HAGER, Cat No: HNW401JR or equivalent model in SCHNEIDER / ABB)
S&F in repair MCCB, 4 pole, 36 KA, with microprocessor release, 250 Amps, Ics=100% of Icu, 415 Volts AC with all accessories complete all as specified and directed. (Make: L&T, Cat No: CM92151OOOOX1 / LEGRAND, Cat No: 6691 83 / C&S, Cat No: CSE2SX250ETM4P-250A / HAGER, Cat No: HNT251JR equivalent model in SCHNEIDER / ABB)
S&F in repair MCCB, 4 pole, 36 KA, with microprocessor release, 160 Amps, Ics=100% of Icu, 415 Volts AC with all accessories complete all as specified and directed. (Make: L&T, Cat No: CM92152OOOOX1 / LEGRAND, Cat No: 6691 82 / C&S, Cat No: CSE2NN250ETM4P-160A / HAGER, Cat No: HNS161JR or equivalent model in SCHNEIDER / ABB)
SCHEDULE 'A' PART-III (AIR CONDITIONING WORKS) Taking down for servicing of Split Type AC 1.5 TR Capacity, any make, including cleaning of cooling coil, air/plasma filters of indoor units and condenser, compressor, fan motor etc of outdoor unit with vacuum cleaner or cleaning solution including checking the serviceability of electrical/electronic circuits, relays, wiring kit, thermostat switches, knobs, remote control unit including PCB, fan, blower, etc, changing electrical connections and keeping the AC unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and refixing the same in existing position complete all specified and as directed by Engineer-in-Charge. (NOTE: Replacement of parts, if required shall be measured and paid seperately under respective items here-in-after)
-ditto- but for 2.0 TR Split Type AC
Taking down for servicing of Window type AC 1.5 TR Capacity, any make including cleaning of cooling coil, air filters, condenser, compressors, fan motor etc with vacuum cleaner or cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches, knobs, remote control unit including PCB, fan, blower, etc, changing electrical connections and keeping the AC unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and refixing the same in existing position complete all specified and directed by Engineer-in-Charge. (NOTE: Replacement of parts, if required shall be measured and paid seperately under respective items here-in-after)
-ditto- but for 2.0 TR Window Type AC
S&F in repair starting relay for 1.5 TR compressor all as specified and directed.
S&F in repair starting relay for 2 TR compressor all as specified and directed.
S&F in repair Over load protector for compressor suitable for 1.5 TR compressor complete all as specified and directed
S&F in repair Over load protector for compressor suitable for 2.0 TR compressor complete all as specified and directed
S&F in repair thermostat switch for 1.5 TR split/window AC complete all as specified and directed.
S&F in repair thermostat switch for 2.0 TR split/window AC complete all as specified and directed.
S&F in repairs suction copper pipe line heavy duty 1/2'' dia and flair nuts from indoor to outdoor unit of split AC 1.5 /2 TR capacity all as specified and directed.
S&F in repairs discharge copper pipe line heavy duty 1/4" dia and flair nuts from indoor to outdoor unit of split AC 1.5 TR /2 TR capacity all as specified and directed.
S&F in repairs discharge copper pipe line heavy duty 5/8" dia and flair nuts from indoor to outdoor unit of split AC 1.5 TR /2 TR capacity all as specified and directed.
S&F in repairs discharge copper pipe line heavy duty 3/8" dia and flair nuts from indoor to outdoor unit of split AC 1.5 TR /2 TR capacity all as specified and directed.
S&F in repairs discharge copper pipe line heavy duty 3/4" dia and flair nuts from indoor to outdoor unit of split AC 1.5 TR /2 TR capacity all as specified and directed.
S&F in repairs PVC pipe nylon imbraided 15 mm dia for condenser water drain fitted with clamps/ concealed in wall all as specified and directed.
S&F Foam insulation for copper tubing of size 1/2'' dia complete all as specifed and directed.
S&F Foam insulation for copper tubing of size 5/8'' dia complete all as specifed and directed.
S&F Foam insulation for copper tubing of size 1/4'' dia complete all as specifed and directed.
S&F Foam insulation for copper tubing of size 3/8'' dia complete all as specifed and directed.
S&F Foam insulation for copper tubing of size 3/4'' dia complete all as specifed and directed.
S&F in repair running capacitor 36 Mfd capacity in metal container pin type all as specified and directed.
S&F in repair running capacitor 50±4 Mfd capacity in metal container pin type all as specified and directed.
S&F in repair running capacitor 50±6 Mfd capacity in metal container pin type all as specified and directed.
S&F in repair running capacitor 6 Mfd capacity in metal body pin type all as specified and directed.
S&F in repair running capacitor 4 Mfd capacity in metal body pin type all as specified and directed.
Dismantling of defective condensing unit of split type AC of 1.5 TR capacity and S&F new condensing unit complete with condensing copper coil, coil frame, wiring kit and running capacitor, relay condensing motor with blade complete all as specified and directed.
-ditto- but for 2.0 TR Split Type AC
Dismantling of burnt blower motor of 1.5 TR split AC (indoor unit) and S&F new blower motor of AC as per OEM complete all as specified and directed. (Make of AC : Carrier/Voltas /Blue Star/LG/Samsung)
Dismantling of burnt blower motor of 2 TR split AC (indoor unit) and S&F new blower motor of AC as per OEM complete al;l a spspecified and directed. (Make of AC : Carrier/Voltas /Blue Star/LG/Samsung)
Dismantling of burnt condensor motor of 1.5 TR split AC (outdoor unit) and S&F new condensor motor of AC as per OEM incl replacement of bearing bushing etc complete all as specified and directed. (Make of AC : Carrier/Voltas /Blue Star/LG/Samsung)
Dismantling of burnt condensor motor of 2.0 TR split AC (outdoor unit) and S&F new condensor motor of AC as per OEM incl replacement of bearing bushing etc complete all as specified and directed. (Make of AC : Carrier/Voltas /Blue Star/LG/Samsung)
Dismantling of burnt swing motor of 1.5 TR split AC (indoor unit) and S&F new swing motor of AC as per OEM complete all as specified and directed. (Make of AC : Carrier/Voltas /Blue star/LG/Samsung)
Dismantling of burnt swing motor of 2.0 TR split AC (indoor unit) and S&F new swing motor of AC as per OEM complete all as specified and directed. (Make of AC : Carrier/Voltas /Blue star/LG/Samsung)
Supply and charging (Top up) the AC unit of 1.5 TR /2 TR split type AC unit with Refrigerant Gas compatible to R-22 type in required quatity complete all as specified and directed.
Supply and charging (Top up) the AC unit of 1.5 TR /2 TR split type AC unit with Refrigerant Gas compatible to R-134 type in required quatity complete all as specified and directed.
Supply and charging (Top up) the AC unit of 1.5 TR /2 TR split type AC unit with Refrigerant Gas compatible to R-410 type in required quatity complete all as specified and directed.
Supply and charging (Top up) the AC unit of 1.5 TR /2 TR split type AC unit with Refrigerant Gas compatible to R-32 type in required quatity complete all as specified and directed.
Supply and charging the AC unit of 1.5/2/2.5/3.5/4.5 TR split type AC unit with Nitrogen Gas for detecting of leakages required as per site quatity complete all as specified and directed.
S&F in repair of suction valve size 1/2" complete all as specified and directed .
S&F in repair of discharge valve size 1/4" complete all as specified and directed.
S&F in repair of suction valve size 5/8" complete all as specified and directed .
S&F in repair of discharge valve size 3/8" complete all as specified and directed.
Supply and fixed in repairs of air filter made out of Nylon suitable for 1.5 TR capacity split AC of any Make and model complete all as specified and directed.
Supply and fixed in repairs of air filter made out of Nylon suitable for 2 TR capacity split AC of any Make and model complete all as specified and directed.
Dismantling of un-serviceable cooling coil unit, any type or size of indoor unit of split type Air Conditioner of capacity 1.5 TR by cutting the suction line and discharge line, and providing new cooling copper coil of indoor unit (of same capacity) including testing on completion complete all as directed by the Engr-in-Charge.
-ditto- but for 2.0 TR Split Type AC
M&L for carrying out pressure leak test of Split Type ACs 1.5 capacity by Nitrogen gas pressure for detecting leak in cooling unit refrigerant pipe and repairing the leak by welding or brazing of cooling unit and refrigerant pipe, putting under pressure for leak, checking after repairs of leak pipe including gas charging transporting & carrying out Tools and Plant required at site complete all as specified and directed.
-ditto- but for 2.0 TR Split Type AC
M&L carrying out pressure leak test of 1.5 TR window AC by Nitrogen gas pressure for detecting leak in cooling unit refrigerant pipe and repairing the leak by welding or brazing of cooling unit and refrigerant pipe, putting under pressure for leak checking after repairs of leak pipe including gas charging transporting & carrying out Tools and Plant required at site complete all as specified and directed.
-ditto- but for 2.0 TR Window Type AC
S&F in repair new PCB (printed circuit board) alongwith new cordless remote, visual eye demo plate and connected wiring of indoor unit of Split AC of capacity 1.5 TR complete all as specified and directed.
-ditto- but for 2.0 TR capacity Split AC
Supply and fixing in repairs front grill for window AC of 1.5 TR /2TR of existing make complete all as specified and directed.
S&F PVC insulated and PVC round sheathed copper conductor (flexible) industrial cable, (FRLS-H) 1100 Volts, conforming to IS 694 of size 2.5 sqmm 3 Core connecting electrical equipments with terminal lugs / clips as per site requirement, complete all as specified and as directed.
S&F Bottom tray of 1.5 ton /2 ton capacity window type AC made out of 14 SWG mild steel sheet including painting with two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
Taking out existing out door unit of split type Air Conditioner including refrigerant lines and electrical connections (of capacity 1.5 TR / 2.0 TR) and re-fixing at new location as directed alongwith fixing arrangement with nuts and bolts complete all as directed by the Engr-in-Charge. (Note :- Excess requirement of refrigerant pipe line, electric connection cable, drain pipe topping up of refrigerant gas shall be measured and paid separately under relevant item of this schedule)
Taking out existing indoor unit of split type Air Conditioner including refrigerant lines and electrical connections of capacity 1.5 TR / 2.0 TR) and re-fixing at new location alongwith fixing arrangement with screwed on wooden gutka on wall surface and making good the disturbed surfaces complete all as directed by the Engr-in-Charge. (Note :- Excess requirement of refrigerant pipe line, electric connection cable ,drain pipe and topping up of refrigerant gas to be measured and paid separately under relevant item of this schedule)
S&F Compressor sealed unit for Split type Air Conditioner of capacity 1.5 tonne reciprocating compressor by removing of old burnt compressor and fixing as per manufacturer instruction including providing connections of gas line, fixing of copper tubes of suitable sizes, hand shut off valves, relays, starting and running capacitors etc complete all as specified and directed. (Note :- Charging of gas refrigerant will be paid and measured separately
-ditto- but for 2.0 TR capacity reciprocating compressor
All as per item No 154 here in before but 1.5 TR capacity rotary type compressor
All as per item No 154 here in before but 2 TR capacity rotary compressor
S&F Condenser fan blade suitable for 1.5 TR capacity Split type Air Conditioner including taking out old one complete all as specified and as directed.
S&F Condenser fan blade suitable for 2.0 TR capacity Split type Air Conditioner including taking out old one complete all as specified and as directed.
S&F Roller runner, suitable for 1.5 TR capacity Split type Air Conditioner including taking out old one complete all as specified and as directed.
S&F Roller runner, suitable for 2.0 TR capacity Split type Air Conditioner including taking out old one complete all as specified and as directed.
Taking down indoor unit of 1.5 TR capacity by preserving the existing gas in outdoor unit, checking and overhauling the complete indoor unit part by part and refixing at same position including testing complete all as directed by the Engr-in-Charge. (Note:-The repair of indoor motor, filters and roller runner to be measured and paid separately under relevant item of this BOQ)
-ditto- but for 2.0 TR capacity indoor unit
S&F in repair powder coated metallic stand (02 nos) for fixing outdoor units of Split Type Acs of 1.5/2.0 TR capacity complete all as specified and directed.
Taking down unserviceable blower motor base (2mm thick Mild Steel CRCA Sheet) of 1.5 TR/2TR capacity split AC and supply and fixing new blower motor base by welding / fixing by nut and bolt refixing the blower motor after completing the base and aligning the motor complete as directed by the Engr-in-Charge.
S&F Compressor sealed unit of Window type Air Conditioner of capacity 1.5 TR, reciprocating type by removing old burnt compressor and fixing as per manufacturer instruction including providing connections of gas line, fixing of copper tubes of suitable sizes complete all as directed by the Engr-in-Charge.
All as per item No 165 here in before but 2.0 TR capacity reciprocating compressor.
All as per item No 165 here in before but 1.5 TR capacity rotary type compressor.
All as per item No 165 here in before but 2.0 TR capacity rotary compressor.
S&F Cooling coil condenser unit of Window type Air Conditioner of capacity 1.5/2.0 TR including providing connections and fixing in proper position including taking down old one complete all as directed by the Engr-in-Charge.
Taking down unserviceable blower motor of existing make/model of window type Air Conditioner 1.5 TR and refixing in proper position after rewinding and repair including providing all connections, complete all as directed by the Engr-in-Charge.
Taking down unserviceable blower motor of existing make/model of window type Air Conditioner 2.0 TR and refixing in proper position after rewinding and repair including providing all connections, complete all as directed by the Engr-in-Charge.
S&F Blower motor fan blade of existing make/model of window type Air Conditioner 1.5 TR including providing all connections, in proper position as in repair complete all as directed by the Engr-in-Charge.
S&F Blower motor fan blade of existing make/model of window type Air Conditioner 2 TR including providing all connections, in proper position as in repair complete all as directed by the Engr-in-Charge.
S&F Runner of existing make/model of Window type Air Conditioner 1.5 TR including providing all connections, in proper position as in repair complete all as directed by the Engr-in-Charge.
S&F Runner of existing make/model of Window type Air Conditioner 2 TR including providing all connections, in proper position as in repair complete all as directed by the Engr-in-Charge.
Taking down window type Air Conditioner, shifting and installation of same at other location within two Km radius including cutting and opening of existing brick work and making good dismantled portion in cement mortar 1:3 as required in exc. Half Brick but not exc. one brick thick Walls and providing three coats white wash on finished surface complete all as specified and as directed.
M&L Cutting openings, through brick wall for fixing of window type Air Conditioner including necessary wooden frame work not less than 2" by 2" thick size as per AC model including fair finish of side walls in cement mortar (1:6) with three coats white wash, painting of wooden surfaces with two coats of synthetic enamel paint over a coat of pink primer, cleaning and stacking bricks removing surplus serviceable bricks, hard-core and rubbish etc from site complete all as specified and as directed.
S&F in repair Single phase preventer 415 type SPPR (Auto reset 540 volts un balance) complete all as specified and as directed.
S&F in repair power contactor 2 pole, coil voltage 230 Volts of capacity 25 Amps Complete all as specified and directed.
S&F in repair power contactor 3 pole, coil voltage 415 Volts of capacity 32 Amps Complete all as specified and as directed.
S&F in repair remote control hand set for 2.0 TR capacity split AC complete all as specified and as directed.
S&F in repair remote control hand set for 1.5 TR capacity split AC complete all as specified and as directed.
S&F in repair remote control hand set, suitable for 2.0 TR capacity window type AC complete all as specified and as directed.
S&F in repair remote control hand set, suitable for 1.50 TR capacity window type AC complete all as specified and as directed.
M&L for servicing including cleaning of condenser coil fins with mild detergent, cleaning of indoor unit and descaling of condensor coil for Vertical type 3 phase Air Conditioner, of any make/capacity after taking down the outdoor unit and refixing in the existing location or any where and replacement of insulation of suction & discharge line complete all as specified and as directed.
S&F in repair PCB kit complete for Vertical type Air Conditioner of any make and capacity complete all as specified and as directed.
S&F Compressor sealed unit for Vertical type Air Conditioner of capacity 3.0 TR by removing of old burnt compressor from outdoor unit and fixing as per manufacturer instruction complete all as specified and as directed. (Note :- Charging of Refrigerant gas will be measured and paid separately
-ditto- but of capacity 2.5 TR
-ditto- but of capacity 3.5 TR
-ditto- but of capacity 4.5 TR
Taking down unserviceable condensor motor of existing make/ model of Vertical type Air Conditioner 2.5/3.0/3.5/4.5 TR (Outdoor) and refixing in proper position after rewinding and repair including providing all connections complete all as specified and directed.
Taking down unserviceable blower motor of existing make/model of Vertical type Air Conditioner 2.5/3.0/3.5/4.5 TR (Indoor) and refixing in proper position after rewinding and repair including providing all connections complete all as specified and directed.
Dismantling of defective condensing unit of Vertical type Air Conditioner of 2.5 TR capacity and supply and fixing new condensing unit complete with condensing copper coil complete all as specified and directed.
Taking out existing outdoor unit of Vertical type Air Conditioner including refrigerant lines and electrical connections (of capacity 2.5/3.5/4.5 TR) and re-fixing at new location as directed including providing PCC platform of size 900 mm x 600 mm x 200 mm (1:4:8) ) type D-2 using 40 mm graded crushed stone aggregate), finished even and smooth without using extra cement alongwith fixing arrangement with nuts and bolts complete all as directed by the Engr-in-Charge. (Note :- Excess requirement of refrigerant pipe line, electric connection cable and drain pipe shall be measured and paid separately under relevant item of this schedule)
Taking out existing indoor unit of Vertical type Air Conditioner including refrigerant lines and electrical connections of capacity 2.5/3.5/4.5 TR) and re-fixing at new location alongwith fixing arrangement with screwed on wooden gutka on wall surface and making good the disturbed surfaces complete all as directed by the Engr-in-Charge. (Note :- Excess requirement of refrigerant pipe line, electric connection cable and drain pipe to be measured and paid separately under relevant item of this schedule)
Dismantling of defective refrigerator of any make and capacity including transportation to workshop and back for thorough checking of all accessories and components, repairs and reassembling the same after repair/ replacement of defective accessories/components and testing complete all as directed by Engr-in-charge .
Supply & Fix Cooling chamber including cooling coil of existing size shape suitable for refrigerator of size and of capacity 165/180 ltrs complete all as specified and directed
Supply & Fix Cooling chamber including cooling coil of existing size shape suitable for refrigerator of size and of capacity 280/310 ltrs complete all as specified and directed
Supply & Fix Thermostat defrost type switch suitable for refrigerator of capacity 165/220/310 ltrs complete all as specified and directed
Supply & Fix PTC Relay with overload suitable for refrigerator of capacity 165/190/200 ltrscomplete all as specified and directed
Supply & Fix PTC relay with overload suitable for refrigerator of capacity 250/286/310 Ltr complete all as specified and directed
Supply & Fix Capillary tube of size 0.36mm dia for any type/size refrigerator complete all as specified and directed
Supply & Fix Copper pencil strainers of size 4" long double mouth complete all as specified and directed
Supply & Fix PCB with Wiring set complete consisting of PVC insulated flexible wire with stranded copper conductor of size 1.5 sqmm and fixing clips for refrigerator all types.
Supply & Fix Bimetal 2 wire/3wire /4 wire complete all as specified and directed
Supply & Fix Forst free fan motor SP 230 volts complete all as specified and directed
Supply & Fix Sensor for cooling coil complete all as specified and directed
Supply & Fix PCB timer of refrigerator 180-310ltrs required as per site complete all as specified and directed
Supply & Fix Condenser coil for 165 to 200 Ltrs complete all as specified and directed
Supply & Fix Condenser coil for 250 to 310 Ltrs complete all as specified and directed
S&F of heating coil including fixing accessories suitable for 250/286/310 ltrs complete all as specified and directed
Taking out burnt compressor after disconnecting suction and discharge line and supply and fixing new compressor as per existing including testing complete all as specified and directed for Regrigerator of Capaicty 165/180 Ltrs complete all as specified and directed. (Note: Re- Charging of gas will be measured and paid separetely)
Taking out burnt compressor after disconnecting suction and discharge line and supply and fixing new compressor as per existing including testing complete all as specified and directed for Refrigerator of Capaicty 285/310 Ltrs complete all as specified and directed. (Note: Re- Charging of gas will be measured and paid separetely)
Dismantling of defective water cooler storage type of 40/80/120/150 ltrs capacity including transportation to workshop and back for thorough checking/including all accessories and components re-assembling the same after repair/ replacement of defective accessories/ components including testing complete all as specified and directed.
Supply & Fix Aluminium fan blade for blower motor for water cooler of capacity 40/80/120/150 ltrs complete all as specified and directed
Supply & Fix PCB and Wiring set complete consisting of PVC insulated cable wiring stranded copper conductor connecting clips etc suitable for water cooler 40/80/120/150 ltrs complete all as specified and directed
Supply & Fix Thermostat including plastic regulating knob as per existing for water cooler of cooling capacity 40/80/120/150 ltrs complete all as specified and directed
Supply & Fix Relay for water cooler type suitable for water cooler storage cooling capacity 40/80 ltrs/hrs complete all as specified and directed
Supply & Fix Relay for water cooler type suitable for water cooler storage cooling capacity 60/120/150 ltrs/hrs complete all as specified and directed
Supply & Fix Over load protector for compressor suitable for water cooler of capacity 40/80 Ltrs complete all as specified and directed
Supply & Fix Over load Protector for compressor suitable for water cooler of capacity 120/150 ltrs/hrs complete all as specified and directed
Supply & Fix Self closing bib tap/push tap 15mm dia, chromium plated steel suitable for water cooler 40/80/150/120 ltr/hrs capacity complete all as specified and directed..
Supply & Fix PVC connection pipe high density 15mm dia 300mm long including jublee clamps for inner connection from tank outlet to tap complete all as specified and directed.
Supply & Fix 15 mm dia PVC connection pipe 450 mm long complete with PVC union at both end complete all as specified and directed. (MAKE : PRAYAG, Cat No. 323 / POLYTUF, Cat No. 4003 or equivalent model in SHAKTI / JEXON / CERA)
Supply & Fix 15 mm dia Float valve PVC complete with all accessories complete all as specified and directed
Supply & Fix new compressor suitable for 40/40 ltr/hrs storage capacity water cooler including testing all as specified and directed by Engineer-in-Charge. (Note: Recharging of gas will be measured and paid separately).
Supply & Fix new compressor suitable for 40/80 ltr/hrs storage capacity water cooler including testing all as specified and directed by Engineer-in-Charge. (Note: Recharging of gas will be measured and paid separately).
Supply & Fix new compressor suitable for 120 ltr/hrs storage capacity water cooler including testing all as specified and directed by Engineer-in-Charge. (NOTE: Recharging of gas will be measured and paid separately).
Supply & Fix new compressor suitable for 150 ltr/hrs storage capacity water cooler including testing all as specified and directed by Engineer-in-Charge. (NOTE: Recharging of gas will be measured and paid separately).
Taking out old burnt Condenser fan motor and supply and fixing of new blower motor and testing suitable for water cooler any make or type.
Dismantling of defective deep freezer including transportation to workshop and back of any capacity, size and type for thorough checking of all accessories and components re-assembling the same after repair/ replacement of defective accessories/components including testing complete all as specified and directed by the Engr-in-Charge
Supply & Fix new deep freezer compressor for storage capacity of 400 ltrs deep freezer including testing all as specified and directed . (NOTE: Recharging of gas will be measured and paid separately).
Supply & Fix new deep freedge compressor for storage capacity of 500 ltrs deep freezer including testing all as specified and directed . (NOTE: Recharging of gas will be measured and paid separately).
Supply & Fix Relay for deep freezer of any size/capacity complete all as specified and directed
Supply & Fix Overload for compressor of deep freezer of any size/capacity complete all as specified and directed
Supply & Fix Thermostate for deep freezer complete al as specified and directed
Supply & Fix 4" condenser fan motor 240 volt complete all as specified and directed
M&L for making holes of required dia on walls of any type and thickness for connecting copper pipes of indoor and outdoor units of Split ACs 1.5/2.0 TR by core cutting drill machine as per site requirement and making good the disturbed surfaces by palstering etc duly painted as per existing finishes complete all as specified and directed.
GENERAL NOTES FOR SCH 'A' PART-III :- (1) The works for repair of ACs and other connected refrigeration works shall be got carried out through experienced and qualified refrigeration mechanics. Necessary documents wrt qualification/experience shall be submitted by the contractor to Engineer-in-Charge before commencement of refrigeration works. (2) Defective spares for making the ACs, Refrigeratiors, Water Coolers, Deep Freezer units in satisfactory working condition will be measured & paid separately under relevant items. (3) Major type of spares have been considered in BOQ. Quoted rate is deemed to be inclusive of consumables and minor spares, nuts, bolts etc. No claim shall be admissible in this regard during execution of work. (4) Make of spares, accessories shall be as per OEM or as approved by GE in writing.
ELECTRO FREEZE
INDIA ELECTRICAL EQUIPMENTS
M/S J S ENTERPRISES
RADHA ENTERPRISE
UNIVERSAL
SUDHA ENTERPRISES
EASTERN REFRIGERATION AND ELECTRICAL CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .