Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.2 LAccepted-AOC METHOPARA GANGANAGAR KOLKATA 700132 | KOLKATA | NORTH 24 PARGANAS | WEST BENGAL | 700132 | L1 | Accepted-AOC 1st lowest | |
| 2 | L2₹8.3 L+₹2,539 (0.31%)Rejected-Finance GR 8 ADDA 1 FLOOR CITY CENTRE DURGAPUR 713216 | DURGAPUR | PASCHIM BARDHAMAN | WEST BENGAL | 713216 | L2 | Rejected-Finance 2nd lowest | |
| 3 | L3₹8.3 L+₹2,821 (0.34%)Rejected-Finance AT DANGALPARA SURJ BIRBHUM PIN 731191 | SURI | BIRBHUM | WEST BENGAL | 731191 | L3 | Rejected-Finance 3rd lowest | |
| 4 | L4₹8.3 L+₹5,021 (0.61%)Rejected-Finance PATPUR BANKURA | BANKURA | BANKURA | WEST BENGAL | 722101 | L4 | Rejected-Finance 4th lowest |
Tender Value
Refer Docs
EMD Value
₹16,481
Closing Date
5 May 2023, 12:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer, PWD
PWD Compound, Kenduadihi, Near Bhairabsthan,Bankura-722102
Construction of Science Building in Bankura University in the District of Bankura Electrical Renovation Works at different Hall for Faculty spaces due to creation of partition works in Science Building Bankura University Bankura .
2023_WBPWD_522609_1
WBPWDTE/EE/BED/NIQ_158/Q of 2022-23-2nd Call Tende
Open Tender
ELECTRICAL WORKS ORG
Item Wise
14 days
Bankura Electrical Division. Bankura
Please refer Tender documents.
3 documents required · 3 mandatory
₹16,481
28 Aug 2024
28 Apr 2023
8 May 2023
28 Apr 2023
5 May 2023
28 Apr 2023
Amount
SUB-HEAD --DISTRIBUTION WIRING Distribution wiring in 1.1 KV grade 3x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (HAVELLS/KEI/RR KABEL/POLYCAB) in suitable size PVC Casing-Capping (Precision make) ,to light/fan/call bell points with Modular type switch as per GS [ PVC Casing Capping on Surface and Switch board Concealed] with following average run. 10 Mtr. [ 3 (e) / E- 21 ]
Distn. wiring in 3 X 22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed single core stranded copper wire in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point with Modular type plug socket & switch as per GS. On Board [ 3 (i) / E- 20 ]
S & F PVC Rigid conduit FR precesion Make on wall Celling with Saddles and other Accessories as required and mending good damages to building works 20 mm size
Supplying and Drawing 1.1 KV single core stranded 'FRLS' PVC insulated & unsheathed single core stranded copper wire (HAVELLS/KEI/RR KABEL/POLYCAB) of the following sizes in the prelaid polythene pipe as per GS. 3 x (1.5 sqmm) [1(b) / E- 9 ]
2x(2.5 sqmm)+1x(1.5 sqmm) [ 1(s) / E-9 ]
2x (4 sqmm) + 1x (2.5 sqmm) [ 1 (y) / E- 9 ]
Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes(in mm ) flushed in wall as per GS 200 x 150 x 65 [11(d)/E-4]
SUB-HEAD -- PLUGS & SOCKETS Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Legrand/Crabtree/Roma/as per direction of EIC) with 16A Modular type switch, without plug top on 6 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. as per G.S
Supply & Fixing 240 V, 4 nos. 6 A, 3 pin Modular type plug socket with 4 nos. 6A Modular type switch, 16A Modular switch type MCB as per GS [ 12 /E-18 ]
Supply & Fixing 240 V, 2 nos. 5 A, 3 pin Modular type plug socket with 2 nos. 5 A Modular type switch (Legrand/Crabtree/Roma/as per direction of EIC), Indicator without plug top on GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc, with connector as per G.S.
SUB-HEAD -FIXING OF LIGHT FITTINGS Fixing only florescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports etc as per G.S [ 15 / C-2 ]
Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit as per GS [16/C-2 ]
SUB-HEAD - SUPPLY OF LIGHT FITTINGS Supply of 4 Ft. single/twin LED light fitting for indoor application,complete with all accessories & LED tubes having following Model / Cat No. Make -Philips TMC 501 P1xT-LED 22wP3241 with 18 master tube./similar to Crompton/Havells)
TMC 501 P2xT-LED 22wP3242 with 2 nos 18 master tube. ./similar to Crompton/Havells.
SUB-HEAD -- FIXING OF FANS Supply & Fixing 240 V Modular Socket type fan regulator (Step type)(Legrand/Crabtree/Roma/as per direction of EIC) on existing sheet metal switch board as per GS [ 10 / E-18 ]
Dismentaling of existing tube light, fan , wire and cables etc. As per EIC
Dismentalling of 1.5 /2.0 Tr. Split Type AC machine, both Indoor & outdoor unit and all Accessories including Copper pipe & Water drainage PVC Pipe, MS Brackect etc.
SUB-HEAD -- MISCELENEOUS S&F OLP-3 incorporated in a box having a 20amp MCB SPN ,compsit flash type 250 V. 6 pin 25 Amp. Plug socket with 25Amp MCB. in the box made of 16 SWG CRC sheet with bakelite top cover and earthing attachment in conceal in wall as per G.S.
S&F sheet metal 2 module Anodised box in conceal in wall incl S & Fbase & top incl S & F 25A capacity 5 pin base & Top North Make and earthing attachment as per G.S.
Installation, Testing & commissioning of 1.5/2.0 Tr. Split type AC both indoor/ outdoor unit incl. S& F of 40 X 40 X 5 mm MS angle iron frame for installation of ODU and sealing of the holes in wall created during the copper pipe connection between IDU & ODU by proper sand-- cement plastering and painting (both inside and outside) to match up with the original finish mending good the damages to complete the instn as per direction of EIC
S& F laying of - (i) gauge copper pipe 5/8" 0.7 mm thick for suction (ii) copper pipe 1/4" 0.6 mm thick for discharge with 9 mm thick thermal insulation foam both for suction & discharge pipe and mending good the holes & damages as directed by EIC.
S & F of flexible PVC high quality water carrying pipe of proper size for draining water from already installed AC to any available (nearest) drain water pipe or near to ground level and the pipe must be properly saddled with the wall incl. proper insertion of the flexible pipe to drain water pipe and sealing the entry with required materials like PVC tape, High quality sealing the entry with required materials like PVC tape, high quality sealing gum etc. as reqd. All these arrangement for fixing must be arranged by the agency itself as per direction of EIC.
Supplying & Charging of Refrigerant -R32
S & F 450 mm Wall Fan Tornado Wall II Make -Orient/Usha/Crompton
Supply & Delivery split type fixed speed 1 Ton 5 star air conditioning mahine having the following specificatio Compressor. Type Rotary Rated cooling capacity (watts) 3516, power consumption (watts) 537.82 Powerfull mode On/off Timer, with advance startup. Digilock one touch silent Fan Speed, Auto Restart, Soft Dry Refrigirant R32.(Make-Hitachi/Daikin/O Genaral(incl. instalation kit)
S & F 100 W Blue Flood light As per G.S
S & F Post Top Light Model No- LPTO-40-CDL-M
S & F 1400 mm Celling Fan Make USHA Striker/ ORIENT PSPO
DURGAPUR POWER
BABA ELECTRIC
RS SYSTEMS AND PROJECTS
technical_1080541.pdf
PDF • 0.56 MB
techsummary_1080541.pdf
PDF • 0.63 MB
finance_1080541.pdf
PDF • 0.74 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_1080541.pdf
PDF • 0.75 MB
158Q_2nd_call.pdf
PDF • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .