Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance 135 CHAKRANA TIWARI CHAKA NAINI PRAYAGRAJ 211008 UTTAR PRADESH | PRAYAGRAJ | UTTAR PRADESH | 211008 | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
13 Jul 2022, 4:00 pmClosed
Executive Engineer
Electric Division JPDCL Udhampur
Creation of substations
2022_PDD_175462_1
ED/UDH/24 of 2022-23, dt. 21-06-2022
Open Tender
Electrical Works
Turn-key
30 days
in District Udhampur
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
Executive Engineer Electric Division JPDCL
₹30,000
16 Sept 2022
22 Jun 2022
15 Jul 2022
22 Jun 2022
13 Jul 2022
22 Jun 2022
22 Jun 2022 - 29 Jun 2022
Amount
SUPPLY, ERECTION, TESTING & COMMISSIONING FOR 25KVA SUB STATION
11/0.433 KV, 3- Phase 25 KVA Distibution Transformer with Bimettalic Terminal Connectors Energy Level-2 (Aluminium Wound and ) LV Cable box having detachable aluminium gland plate (Transformer shall be provided by the Department)
9 Mtr. Long poles( ST-410 SP33) (poles shall be provided by the Department)
11 KV Polymeric composite Disc insulator 12KV, Min failing load 45KN, lighetning impulse 75KV positive and 80 KV negative creepage distance 320 mm with fittings
11 kv 11 KV Polymeric composite pin insulator 12KV, 5KN lighetning impulse 75KV positive and 80 KV negative creepage distance 320 mm
50 mm Sq. single core cable 1.1 KV Grade, PVC insulator stranded conductor FRLS
Galvanized Channel, Angle Iron & Flat iron of sizes including clamps
Al. Thimbles 50 mm sq
Gapless surge arrestor 9KV,10 KV LA with polymer housing (Stn. type)
11 KV HG Fuse Set 3 phase 200 Amp
11 KV GO AB Switch 3 phase ,3 pole,200 amp, vertical type
Galvanized stay set with 50X8 mm, stay clamp, guy insulator (2 no), anchor plate (200X6mm), outbolts, 2 Nos turn buckles, 1.8m long, 16mm diameter solid GS stay rod &7/3.15mm dia GI stranded wire complete
Wedge Connectors/PG Clamps
Danger plates with Clamps
GI Barbed Wire for anti climbing
LT Prodigy Meter
Cement Bottoming 1:2:4 mix as per REC standards 0.5cum/pole
Galvanized Nuts & Bolts
Earthing of substation-Excavation o0f earth pit of dia 650 mm & depth 3000mm, installation of Earthing pipe of 40mm Nominal bore &4mm wall thickness & length 2.5 mtr long as per IS 1239. GI Strip 50X6 for neutral earthing and size 25X3 mm for connection of transformer body, GO Set & Lightning arrestor as per IS2629/85, GI nuts & bolts, refilled with earth enhancement materials and earth chamber with RCC salab cover
LT Switch including clamps ,angle iron (50X6mm), aluminium busbar strip, bus bar insulator/post insulator etc
Painting of pole with one coat of red oxide and two coats of Aluminium paint
Description of Work / Item(s)
Amount
SUPPLY, ERECTION, TESTING & COMMISSIONING FOR 63KVA SUB STATION
11/0.433 KV , 3- Phase 63KVA Distibution Transformer with Bimettalic Terminal Connectors Energy Level2 and with LV Cable box having detachable aluminium gland plate( Transformer shall be provided by the Department)
9 Mtr. Long poles(ST-410 SP33) (poles shall be provided by the Department)
70 mm Sq. single core cable 1.1 KV Grade,PVC insulated stranded conductor FRLS
11 KV Polymeric composite Disc insulator 12KV, Min failing load 45KN, lighetning impulse 75KV positive and 80 KV negative creepage distance 320 mm with fittings
11 KV Polymeric composite Pin insulator 12KV, 5KN lighetning impulse 75KV positive and 80 KV negative creepage distance 320 mm
GI Channel/Angle/Flat of Size including Clamps
Al. Thimbles 70 mm sq
Gapless surge arrestor 9KV,10 KA LA with polymer housing (Stn. type)
11 KV HG Fuse Set 3 phase 200 Amp
11 KV GO AB Switch 3 phase ,3 pole,200 amp, vertical type
Galvanized Nuts & Bolts
LT Distribution Box for 63 KVA DTR with MCCB For Inconmer & SFU'S Outgoing Circuits
Wedge Connectors/PG Clamps
Earthing of substation-Excavation o0f earth pit of dia 650 mm& depth 3000mm, installation of Earthing pipe of 40mm Nominal bore &4mm wall thickness &length 2.5 mtr long as per IS 1239. GI Strip 50X6 for neutral earthing and size 25X3 mm for connection of transformer body,GO Set &Lightning arrestor as per IS2629/85, GI nuts&bolts, refilled with earth enhancement materials and earth chamber with RCC salab cover
Danger plates with Clamps
LT Prodigy Meter
Painting of pole with one coat of red oxide and two coats of Aluminium paint
Cement Bottoming 1:2:4 mix as per REC standards .5cum/pole including cost of material.
Galvanized stay set with 50X8 mm , stay clamp, guy insulator(2 no), anchor plate(200X6mm),outbolts,2 Nos turn buckles,1.8m long, 16mm diameter solid GS stay rod&7/3.15mm dia GI stranded wire complete
GI Barbed Wire for anti climbing
Description of Work / Item(s)
Amount
SUPPLY, ERECTION, TESTING & COMMISSIONING FOR 100 KVA SUB STATION
11/0.433 KV, 3- Phase 100 KVA Distibution Transformer with Bimettalic Terminal Connectors Energy Level 2, Aluminum Wound and with LV Cable box having detachable aluminium gland plate(Transformer shall be provided by the Department)
9 Mtr. Long poles(ST-410 SP33) (poles shall be provided by the Department)
185 mm Sq. single core cable 1.1 KV Grade,PVC insulator stranded conductor FRLS
11 KV Polymeric composite Disc insulator 12KV, Min failing load 45KN, lighetning impulse 75KV positive and 80 KV negative creepage distance 320 mm with fittings
11 KV Polymeric composite Pin insulator 12KV, 5KN lighetning impulse 75KV positive and 80 KV negative creepage distance 320 mm
Gavanized Channel/Angle/Flat of Size including Clamps
Al. Thimbles 185 mm sq
Gapless surge arrestor 9KV, 10 KA LA with polymer housing (Stn. Type)
11 KV HG Fuse Set 3 phase 200 Amp
11 KV GO AB Switch 3 phase ,3 pole,200 amp, vertical type
Galvanized Nuts & Bolts
Earthing of substation-Excavation o0f earth pit of dia 650 mm& depth 3000mm, installation of Earthing pipe of 40mm Nominal bore &4mm wall thickness &length 2.5 mtr long as per IS 1239. GI Strip 50X6 for neutral earthing and size 25X3 mm for connection of transformer body, GO Set &Lightning arrestor as per IS2629/85, GI nuts&bolts, refilled with earth enhancement materials and earth chamber with RCC salab cover
Wedge connectors/PG clamp
LT Distribution Bos of 100 KVA DTR with MCCB for Incomer & SFU's for Outgoing Circuit
Danger plates with Clamps
LT Prodigy meter
Cement Bottoming 1:2:4 mix as per REC standards .5cum/pole of poles
Painting of pole with one coat of red oxide and two coats of Aluminium paint
Galvanized stay set with 50X8 mm , stay clamp, guy insulator(2 no), anchor plate(200X6mm),outbolts,2 Nos turn buckles,1.8m long, 16mm diameter solid GS stay rod&7/3.15mm dia GI stranded wire complete
GI Barbed Wire for anti climbing
Description of Work / Item(s)
Amount
SUPPLY, ERECTION, TESTING & COMMISSIONING FOR 250KVA SUB STATION
11/0.433 KV , 3- Phase 250 KVA Distibution Transformer with Bimettalic Terminal Connectors Energy Level 2, Copper Wound and with LV Cable box having detachable aluminum gland plate(Transformer shall be provided by the Department)
9 Mtr. Long poles(ST-410 SP33) (Poles shall be provided by the Department)
300 mm Sq. single core cable 1.1 KV Grade, PVC insulator stranded conductor FRLS
Al. Thimbles 300 mm sq.
11 KV Polymeric composite Disc insulator 12KV, Min failing load 45KN, lighetning impulse 75KV positive and 80 KV negative creepage distance 320 mm with fittings
11 KV Polymeric composite Pin insulator 12KV, 5KN lighetning impulse 75KV positive and 80 KV negative creepage distance 320 mm
Galvanized Channel/Angle/Flat of Size including Clamps
Gapless surge arrestor 9KV,10 KA LA with polymer housing (Stn. Type)
11 KV HG Fuse Set 3 phase 200 Amp
11 KV GO AB Switch 3 phase , 3 pole, 200 amp, vertical type
Galvanized Nuts & Bolts
Earthing of substation-Excavation o0f earth pit of dia 650 mm& depth 3000mm, installation of Earthing pipe of 40mm Nominal bore &4mm wall thickness &length 2.5 mtr long as per IS 1239. GI Strip 50X6 for neutral earthing and size 25X3 mm for connection of transformer body,GO Set &Lightning arrestor as per IS2629/85, GI nuts&bolts, refilled with earth enhancement materials and earth chamber with RCC salab cover
LT Distribution Bos of 250 KVA DTR with MCCB for Incomer & SFU's for Outgoing Circuit
3 phase 4 wire Trivector Meter with CT
Danger Plate with clamps
Wedge connectors/PG Clamps
Cement Bottoming 1:2:4 mix as per REC standards .5cum/poleof poles
Painting of pole with one coat of red oxide and two coats of Aluminium paint
Galvanized stay set with 50X8 mm , stay clamp, guy insulator(2 no), anchor plate(200X6mm),outbolts,2 Nos turn buckles,1.8m long, 16mm diameter solid GS stay rod&7/3.15mm dia GI stranded wire complete
GI barbed wire for anti climbing
Description of Work / Item(s)
Amount
SUPPLY, ERECTION, TESTING & COMMISSIONING FOR 400KVA SUB STATION
11/0.433 KV , 3- Phase 400 KVA Distibution Transformer with Bimettalic Terminal Connectors Energy Level 2, Copper Wound and with LV Cable box having detachable aluminum gland plate(Transformer shall be provided by the Department)
9 Mtr. Long poles (ST-410 SP33) (Poles shall be provided by the Department)
400 mm Sq. single core cable 1.1 KV Grade,PVC insulator stranded conductor FRLS
11 KV Polymeric composite Disc insulator 12KV, Min failing load 45KN, lighetning impulse 75KV positive and 80 KV negative creepage distance 320 mm with fittings
11 KV Polymeric composite Pin insulator 12KV, 5KN lighetning impulse 75KV positive and 80 KV negative creepage distance 320 mm
Transformer pad/Channel for bedding /Angle/Flat of Size including Clamps for LA/GO/Horngap set
Gapless surge arrestor 9KV,10 KA LA with polymer housing (Stn. Type)
11 KV HG Fuse Set 3 phase 200 Amp
11 KV GO AB Switch 3 phase ,3 pole,200 amp, vertical type
Al. Thimbles 400 mm sq.
Galvanized Nuts & Bolts
Earthing of substation-Excavation 0f earth pit of dia 650 mm& depth 3000mm, installation of Earthing pipe of 40mm Nominal bore &4mm wall thickness &length 2.5 mtr long as per IS 1239. GI Strip 50X6 for neutral earthing and size 25X3 mm for connection of transformer body,GO Set &Lightning arrestor as per IS2629/85, GI nuts&bolts, refilled with earth enhancement materials and earth chamber with RCC salab cover
LT Distribution box for 400 KVA DTR with MCCB for incomer & outgoing circuits
Wedge Connector/PG Clmaps
Danger plates with Clamps
3 phase 4 wire trivector meter with CT
Painting of pole with one coat of red oxide and two coats of Aluminium paint
Cement Bottoming 1:2:4 mix as per REC standards .45cum/pole of poles
Galvanized stay set with 50X8 mm , stay clamp, guy insulator(2 no), anchor plate(200X6mm), outbolts,2 Nos turn buckles,1.8m long, 16mm diameter solid GS stay rod & 7/3.15mm dia GI stranded wire complete
GI Barbed Wire for anti climbing
Cement Concerete bed size 2.5X2.5X1.96=12.25 cum
Description of Work / Item(s)
Amount
SUPPLY, ERECTION, TESTING & COMMISSIONING FOR 630KVA SUB STATION
11/0.433 KV , 3- Phase 630 KVA Distibution Transformer with Bimettalic Terminal Connectors Energy Level 2, Copper Wound and with LV Cable box having detachable aluminum gland plate(Transformer shall be provided by the Department)
9 Mtr. Long poles(ST-410 SP33) (Poles shall be provided by the Department
630 mm Sq. single core cable 1.1 KV Grade,PVC insulator stranded conductor FRLS
11 KV Polymeric composite Disc insulator 12KV, Min failing load 45KN, lighetning impulse 75KV positive and 80 KV negative creepage distance 320 mm with fittings
11 KV Polymeric composite Pin insulator 12KV, 5KN lighetning impulse 75KV positive and 80 KV negative creepage distance 320 mm
Galvanized Channel/Angle/Flat of Size including Clamps
Gapless surge arrestor 9KV,10 KA LA with polymer housing (Stn. Type)
11 KV HG Fuse Set 3 phase 200 Amp
11 KV GO AB Switch 3 phase ,3 pole,200 amp, vertical type
Al. Thimbles 630 mm sq.
Galvanized Nuts & Bolts
Earthing of substation-Excavation o0f earth pit of dia 650 mm& depth 3000mm, installation of Earthing pipe of 40mm Nominal bore &4mm wall thickness &length 2.5 mtr long as per IS 1239. GI Strip 50X6 for neutral earthing and size 25X3 mm for connection of transformer body,GO Set & Lightning arrestor as per IS2629/85, GI nuts&bolts, refilled with earth enhancement materials and earth chamber with RCC salab cover
LT Distribution box for 630 KVA DTR with MCCB for incomer & outgoing circuits
Wedge Connector/PG Clmaps
Danger plates with Clamps
LT Prodigy meter
Painting of pole with one coat of red oxide and two coats of Aluminium paint
Cement Bottoming 1:2:4 mix as per REC standards .5cum/poleof poles
Galvanized stay set with 50X8 mm , stay clamp, guy insulator(2 no), anchor plate(200X6mm),outbolts,2 Nos turn buckles,1.8m long, 16mm diameter solid GS stay rod&7/3.15mm dia GI stranded wire complete
GI Barbed Wire for anti climbing
Cement Concerete bed size 2.6X2.62X1.96=13.45 cum
ADITYA SHARMA
M R ENGINEERS & TRADERS
vijay builders
M/s R.S CONSTRUCTIONS
vijay builders
ADITYA SHARMA
M R ENGINEERS & TRADERS
M/s R.S CONSTRUCTIONS
AJAY KAPOOR
ADITYA SHARMA
M R ENGINEERS & TRADERS
M/s R.S CONSTRUCTIONS
M/s R.S CONSTRUCTIONS
AJAY KAPOOR
ADITYA SHARMA
M R ENGINEERS & TRADERS
AJAY KAPOOR
ADITYA SHARMA
M R ENGINEERS & TRADERS
M/s R.S CONSTRUCTIONS
AJAY KAPOOR
ADITYA SHARMA
M R ENGINEERS & TRADERS
M/s R.S CONSTRUCTIONS
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .