Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.2 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹12.7 L+₹22,009 (1.76%)Rejected-AOC 37 222 BUNDU KATRA AGRA UP | AGRA | UP | L2 | Rejected-AOC Not Lowest Bidder | |
| 3 | L3₹14.8 L+₹2.2 L (18.0%)Rejected-AOC | L3 | Rejected-AOC Not Lowest Bidder |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
24 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Bharatpur
GE Bharatpur
Repair maintenance and renewal of lightening protection system Depot area under GE bharatpr
2021_MES_416780_1
8003/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE Bharatpur
Class b Category b(I)
7 documents required · 7 mandatory
₹500
Yes
GE Bharatpur
₹40,000
Yes
28 Apr 2021
28 Jan 2021
26 Feb 2021
28 Jan 2021
24 Feb 2021
11 Feb 2021
60 days
Amount
Excavation in trenches in soft/loose soil not exceeding 1.5m wide and not exceeding 1.5 metre in depth and getting out for laying of cable etc. complete all as specified and as directed by Engineer-in-Charge.
Returning, filling in soft/loose soil including spreading, levelling, watering and well ramming, in layers not exc 25 cm complete all as specified and as directed by Engineer-in-Charge.
Removing of surplus soil to a distance not exc. 50 metre and depositing where directed at a level not exc.1.5 metre above the starting point complete all as specified and as directed by Engineer-in-Charge.
Taking down old Unserviceable air termination rod of any size and capacity complete all as specified and as directed by Engineer-in-Charge.
Taking down old Unserviceable aluminium strip from roof and wall of ESHs any size and position including making good to disrurbed surface of wall and roof complete all as specified and as directed by Engineer-in-Charge.
Taking down old Unserviceable GI strip from roof or wall any size and position including making good to disrurbed surface of wall and roof complete all as specified and as directed by Engineer-in-Charge.
Refixing of serviceable Air termination rod as obatin from Item No 4 above including after providing new threading and grinding of tip of air termination rod as per site requirnment on site and directed by Engr in charge complete.
Taking down old Unserviceable GI rusted pipe from roof or wall any size and position including making good to disrurbed surface of wall and roof complete all as specified and as directed by Engineer-in-Charge.
S&F single pointed air termination aluminium rod 12 mm dia and 300 mm long complete all as specified and as directed by Engineer-in-Charge.
S&F aluminium srip of size 25x3 mm complete with saddle and fixing with screw/accessories for roof and down conductor complete all as specified and as directed by Engineer-in-Charge.
Fixing only aluminium srip of size 25x3 mm complete with saddle and fixing with screw/accessories for roof and down conductor complete all as specified and as directed by Engineer-in-Charge.
Supplying and stringing Aluminium conductor, steel reinforced (ACSR) any type of ACSR conductor for airtermination points supported by GI tubing on the roof of the ESHs to inner connect the all termination points including taking down of existing conductor complete all as specified and as directed by Engineer-in-Charge. (Notes : (i) The ACSR conductors shall be conforming to IS-398 and as specified in SSR Part-I.(ii) The unit rate quoted shall also be deemed to include for supply & fixing of aluminium binding wire, aluminium tapes etc which shall not be included in the weight of conductors.(iii) Weight of conductors shall be determined by measuring true horizontal distance between centers of two adjacent poles and compounding the weight of conductors of that size and length and 3% extra added for sag, jointing, jumpers etc. (iv) Weight of the conductors shall be calculated from the nominal weights given in tables in the relevant IS.)
S&F GI pipe medium grade 40 mm dia for protection of GI strip complete all as specified and as directed by Engineer-in-Charge. ( For ACSR conductor pole)
S&F porcelain inculator for roof conductor and down coinductor with one meter intervel secured with suitable screw complete all as specified and as directed by Engineer-in-Charge.
S&F GI pipe light grade 40 mm dia for protection of GI strip complete all as specified and as directed by Engineer-in-Charge.
S&F GI Strip 32x6mm fixed on wall or buried in ground or any other indicated situation complete all as specified and as directed by Engineer-in-Charge.
M&L for framed brackets of angles or tee with web and flanges cut to shape, drilled and counter sunk for screw including bending and welding angles as necessary gusset plates riveting etc not exc 10 kg in weingh each brackets, clamps for holding pipe and aluminium strip for lightning protection complete all as specified and as directed by Engineer-in-Charge.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by mean of GI strip 32x6mm as earthing lead by means of bolts, nuts check nuts and washers of GI or steel and connecting to earthing test point, main switch board, testing on completion including GI pipe 20 mm dia light grade for watering and bringing the same upto 30 cm above normal ground level with plug at top including pipe fittings etc complete and GI pipe 40 mm dia light grade for the protection of GI strip from earth pit to earth point complete including necessary excavation and earth work in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance n.exc 50 m all as specified as shown in electrical plate No 3 SSR Part-I.(Note: earth pit cover is to be made 10mm MS Plate with the projection to overlap the four side of the road covered up to 10 cm with collapsable MS Handle)
M&L for Test point with Junction box of polycarbonate body with minimum rating IP 65 of size not less than 130mmx170mmx80mm complete including made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw fixed with earth strips including nut bolt with washer on both side inside the junction box and junction box shall be fixed on wall/ pole with suitable clamp including accessories complete all as specified and directed. Make of Junction box - Naptune Cat No 1005 / equivalent in Hansel/ Spelsberg including dismantling of old unservieable MS test point box complete.
Demolition of cement concrete (un-reinforced) of any description and any position n.exc 15 cm thickness (below or above GL) complete all as specified and as directed by Engineer-in-Charge.
S&F DMC inculator for wall down conductor for 25 X 3 strip with one meter intervel secured with suitable screw complete all as specified and as directed by Engineer-in-Charge.
S&F DMC inculator for wall down conductor for 32 X 6 strip with one meter intervel secured with suitable screw complete all as specified and as directed by Engineer-in-Charge.
Taking down old Unserviceable rusted earthing materials any size and position including making good to disrurbed surface of wall complete all as specified and as directed by Engineer-in-Charge.
M & L for cutting of bitumanous road or PCC upto 30cm deep and 20cm wide for laying of pipe lines for protection of GI strip and making good surface by PCC 1:2:4 type B-1,20mm grade complete all as specified and as directed by Engineer-in-Charge.
M & L for stay assembly to support GI pipe for Air Termination by providing 4mm dia GI wire 15 RM, 16mm MS Rod 1.35 RM and PCC block 1:3:6 size of 0.6x0.6x0.15M including earth work in sof soil including dismantling old Stay assembly all as directed by Engr-in-Charge.
M&L of PCC 1:2:4 type B-1, 20 mm graded aggregate filling and mass concrete, for road finishing, PCC blocks, earthing pit cover, and foundation concrete complete all as specified and directed by Engr-in-Charge.
Checking/testing of Earth resistance value of earthing pits Installed inside Depot area as requirement basis as directed by Engr in Charge or as schedule and making the damaged earthing serviceable by pouring salted water into earthing or making continuity by GI strips and bringing down the resistance value within specified limits, including maintenance of existing earthing by cleaning the earth chamber funnel and cleaning of vagetation surrouding earthing pit up to 2 mtr complete all as specified and directed by Engr-in-Charge. Note: (i) The entire station will be divided intotwo zones as per earthing location and the contrcator will deploy seperate team for each zone to test the resistance value of earthings in each zone to complete the process within one month. The entire process will be repeated after every six months (half yearly) upto completion of the contract. (ii) one earthing testing in one season is measured one job.(iii) Digital Earth tester will be arrange by the contractor his own. (iv) Date of testing and due date of testing is to be written on a register with sign of user rep & Engr-in Charge submitted to GE. (iv) Testing and correction action is to be done within one month from date of commencement i.e. approx 300 earthings is to be completed within one month. Thereafter on half yearly basis or as directed byEngr-in charge and same is to be completed within one month.The contractor has to deploy electrician with helper and testing equipment and all the resources to complete the task within one month.(v) If any material required for improvement of resistence value which value is more than their permissible limit will be measured and paid seperately.
Dismantling of existing broken PCC earth chambers of any description and providing earth chamber of size 300 mm x 300mm (Internal size),and depth 280mm and 75mm thick with PCC 1:3:6 type C1 using 20mm graded stone aggregate complete all as specified and directed by Engr-in-Charge.
M&L for Replacement of broken earth chamber cover by providing RCC cover of 1:2:4, Type B-1, using 20mm graded stone aggregate of size 300mmx300mmx40mm thick, reinforced with 8mm dia MS TMT bars @100 mm C/C both ways with MS handle 08mm dia complete all as specified and directed by Engr-in-Charge.
S&F GI Funnel with wire mesh on existing 20 mm dia pipe complete all as specified and directed
Labour wok only for alignment of existing earth pit by necessary earth work all as speciied and directed
Refixing of broken earthing strip of aluminium/GI strip joint with providing new nuts, bolts and washer ( min size 10mm dia) incl drilling work & necessary T&P all as specified and directed
PD GUPTA AND COMPANY
AMIT RISHABH BUILDERS PRIVATE LIMITED
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .