GE (AF) AWANTIPUR
GE (AF) AWANTIPUR C/o 56 APO PIN-937208
REPAIR/ MAINT OF VOLTAGE STABILIZER AND MISC WORK AT AF STN AWANTIPUR
2026_MES_795914_1
GE (AF) AWA-49/2026-27
Open Tender
Civil Works
Item Rate
180 days
GE (AF) AWANTIPUR
AS PER NIT AND TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
GE (AF) AWANTIPUR
₹40,000
Yes
27 Oct 2026
27 Oct 2026
19 Nov 2026
27 Oct 2026
17 Nov 2026
10 Nov 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down defective Voltage Stabilizer of capacity varying from 25 KVA to 100 KVA of any make and model installed at different location of 8FBSU from pole/structure/ sub-station after disconnecting the connections and removing to sub-station then transporting the same to a reputed work shop for repairs. After repairing the same transporting back the repaired transformer (including loading and unloading) to the directed location. After installing the stabilisers connections of LT has to be done as directed by Engr-in-Charge.
Note-Items of repair will be measured and paid separately. | 10 | Each Job | - | - |
| - | Taking down defective Voltage Stabilizer of capacity varying from 125 KVA to 250 KVA of any make and model installed at different location of 8FBSU from pole/structure/sub-station after disconnecting the connections and removing to sub-station then transporting the same to a reputed work shop for repairs. After repairing the same transporting back the repaired transformer (including loading and unloading) to the directed location. After installing the stabilisers connections of LT has to be done as directed by Engr-in-Charge.
Note-Items of repair will be measured and paid separately. | 8 | Each Job | - | - |
| - | Taking down defective Voltage Stabilizer of capacity varying from 300 KVA to 500 KVA of any make and model installed at different location of 8FBSU from pole/structure/sub-station after disconnecting the connections and removing to sub-station then transporting the same to a reputed work shop for repairs. After repairing the same transporting back the repaired transformer (including loading and unloading) to the directed location. After installing the stabilisers connections of LT has to be done as directed by Engr-in-Charge.
Note-Items of repair will be measured and paid separately. | 5 | Each Job | - | - |
| - | Opening/stripping off voltage stabilizer of capacity 25 KVA to 100 KVA including draining off oil, washing & cleaning duct, dirt & sludge deposit etc. from all parts. Removing damaged/defective parts requiring replacement, making internal connection servicing of bushings and reassembling the voltage stabilizer after repair and replacement work including new cork gasket, packing nuts, bolts, washer, etc. Complete all as directed.
Note : Servicing will be done by reputed company rep at site only. | 10 | Each Job | - | - |
| - | Opening/ stripping off voltage stabilizer of capacity above 100 KVA to 250 KVA including draining off oil, washing & cleaning duct, dirt & sludge deposit etc. from all parts. Removing damaged/defective parts requiring replacement, making internal connection servicing of bushings and reassembling the voltage stabilizer after repair and replacement work including new cork gasket, packing nuts, bolts, washer, etc. Complete all as directed.
Note : Servicing will be done by reputed company rep at site only. | 8 | Each Job | - | - |
| - | Opening/ stripping off voltage stabilizer of capacity above 300 KVA to 500 KVA including draining off oil, washing & cleaning duct, dirt & sludge deposit etc. from all parts. Removing damaged/defective parts requiring replacement, making internal connection servicing of bushings and reassembling the voltage stabilizer after repair and replacement work including new cork gasket, packing nuts, bolts, washer, etc. Complete all as directed.
Note : Servicing will be done by reputed company rep at site only. | 5 | Each Job | - | - |
| - | Repairing and rewinding of main transformer of voltage stabiliser using super enamelled copper winding wire of existing gauge including PVC sheet, sleeve, varnishing etc of capacity 25 KVA to 100 KVA including following repairs :
(i) Removing top cover of the Voltage Stabilizer and taking out the complete core assembly from the stabilizer including drain out the oil from the stabilizer and clean the conservator.
(ii) Cutting and remove the old burnt coil winding from the limbs and rewinding the limbs by new copper wire as suitable size/ as per existing gauge with proper insulation and varnishing complete.
(iii) Reassembling the complete core assembly, connection to the existing electric supply line and testing all as per satisfaction of Engineer-in-Charge. | 6 | Each Job | - | - |
| - | Repairing and rewinding of main transformer of voltage stabiliser using super enamelled copper winding wire of existing gauge including PVC sheet, sleeve, varnishing etc. of capacity 125 KVA to 250 KVA including following repairs :
(i) Removing top cover of the Voltage stabilizer and taking out the complete core assembly from the stabilizer including drain out the oil from the stabilizer and clean the conservator.
(ii) Cutting and remove the old burnt coil winding from the limbs and rewinding the limbs by new copper wire as suitable size/ as per existing gauge with proper insulation and varnishing complete.
(iii) Reassembling the complete core assembly, connection to the existing electric supply line and testing all as per satisfaction of Engineer-in-Charge. | 5 | Each Job | - | - |
| - | Repairing and rewinding of main transformer of Voltage Stabiliser using super enamelled copper winding wire of existing gauge including PVC sheet, sleeve, varnishing etc of capacity 300 KVA to 500 KVA including following repairs :
(i) Removing top cover of the Voltage Stabilizer and taking out the complete core assembly from the stabilizer including drain out the oil from the stabilizer and clean the conservator.
(ii) Cutting and remove the old burnt coil winding from the limbs and rewinding the limbs by new copper wire as suitable size/ as per existing gauge with proper insulation and varnishing complete.
(iii) Reassembling the complete core assembly, connection to the existing electric supply line and testing all as per satisfaction of Engineer-in-Charge. | 4 | Each Job | - | - |
| - | M&L draining out the transformer oil complete quantity of voltage stabilizer of any make, capacity above 200 KVA to 500 KVA and to keep the same in safe containers dismantling all the parts of voltage stabilizer with the help of hand operated crane or other suitable mean, re-fixing the all parts and assembling with the help of hand operated crane or by other suitable means, re-filing the existing drain out transformer oil and testing the voltage stabilizer complete all as specified.
Note:- Spare parts shall be measured & paid separately. | 8 | Each Job | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.27 MB
BOQ_892688.xls
BOQ • 0.32 MB
Tender49.pdf
Tender Documents • 1.80 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .