Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.7 LAccepted-AOC | L1 | Accepted-AOC THE LOWEST TENDERER | |
| 2 | L2₹20.7 L+₹2.0 L (10.9%)Rejected-Finance | L2 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 3 | L3₹25.4 L+₹6.7 L (36.1%)Rejected-Finance | L3 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 4 | L4₹25.5 L+₹6.9 L (36.8%)Rejected-Finance | L4 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 5 | L5₹25.8 L+₹7.1 L (38.3%)Rejected-Finance | L5 | Rejected-Finance NOT THE LOWEST TENDERER |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
13 Sept 2024, 6:00 pmClosed
GE MH AND RH KHADKI
Military Engineer Services Garrison Engineer MH and Range Hills Range Hills Road Khadki, Pune 411003
REPAIRS TO ROOF WATER PROOF TREATMENT SUNKEN FLOORS WALLS CHAJJAS PLASTER PLINTH PROTECTION CLEANING OF WATER TANK INTERNAL WATER SUPPLY AND OTHER MISC WORKS FOR OTM AND MD ACCN OF DGQA ORG AT AUNDH UNDER GE MH AND RH KHADKI
2024_MES_667662_1
8572/E8
Open Tender
Civil Works
Item Rate
180 days
GE MH AND RH KHADKI
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE MH AND RH KHADKI
₹80,000
9 Nov 2024
24 Jul 2024
16 Sept 2024
24 Jul 2024
13 Sept 2024
7 Aug 2024
24 Jul 2024 - 14 Aug 2024
Amount
Demolition of cement concrete unreinforced of any description and in any position, not otherwise specifically provided for
M & L for cement concrete 1:2:4 type B-0, using 12.5mm graded stone aggregates for filleting, benching, slightly rounding or chamfering on edges, filling undulations / depressions in roof surface, providing concrete platform for tanks wherever required as directed.
Taking down / removing existing water proofing treatment from RCC roof slab including removal of plaster bed below felt / membrane and disposal of the same to distance exceeding 50m but not exceeding 100m as and where directed and M & L for 10 mm thick screeding / rendering in cement mortar 1:4 on concrete roof surface, using Water Proofing Compound @ 3% by weight of cement, surface finished even and smooth without using extra cement all as directed. Note: Water Proofing Compound shall be measured and paid separately.
Supply only intergral water proofing compound.
M & L for cleaning the plastered /concrete surface with wire brush and applying water proofing treatment as under:- (a) Apply one coat of water based bituminious primer @ 0.20 Kg per Sqm. (b) Laying APP polimerised modified membrane weighing not less than 3.5Kg / sqm by torch application method. (thickness of membrane shall not be less than 3 mm). (c) The overlap for APP membrane shall be 75 mm on longitudinal direction and100 mm on transverse direction. (d) Finally applying a coat of solar reflective bituminious aluminium paint @0.15 Kg/Sqm over the membrane.
Disconnecting existing tanks exc 250 & not exc 500, setting asides (or lowering if required) for repairs, cleaning, waterproofing etc and hoisting if required reconnecting and re-fixing in position.
Disconnecting existing tanks exc 500 & not exc 1000, setting asides (or lowering if required) for repairs, cleaning, waterproofing etc and hoisting if required reconnecting and re-fixing in position.
Cleaning the surface with wire brush, detecting sources of leakages and removing/taking down unsound treatment/surface and M&L for carrying out non-destructive waterproofing treatment to sunken portion of slab, floor and walls of bath, WC, WHB and floor traps (combined unit) by using construction chemical method as hydrophobic PU grouting, etc, with first course of injection MDI based PU foam and second course of injection PU plain all as per manufacturers instruction, etc, complete and as directed. The PU foam shall have 100% solids and solvent free, and shall expand 30-40 times its volume at liquid stage in presence of water, the PU plain injection shall have minimum 100 CPS viscosity and shore hardness minimum 50. Make: PIDILITE or equivalent
Making hole and M&L for fixing thr metallic packer for hydrophobic PU foam and Sealer as per manufacturers specification. The PU foam shall have 100% solids and solvent free, and shall expand 30-40 times its volume at liquid stage in presence of water, the PU plain injection shall have minimum 100 CPS viscosity and shore hardness minimum 50. Make: PIDILITE or equivalent
M&L for the tile joint chemical cleaning and re-grouting carefully by washing the existing tille with heavy duty tile cleaner preferbly of M/S Pidilite or equivalent cleaner, again washing with fresh jet water, scratching the joints and filling the same with (white/matching colour) epoxy tile grout of M/s Pidilite, ROFF RTM epoxy or equivalent, or equivalent , curing , cleaning the surface etc, complete all as directed by Engr-in-Charge and as per the sample done at ground level.
M&L for water proofing treatment of External walls, chhajjas DFT: 110 microns by applying two coats of elestromeric coating Raincoat, material covering capabity 3 Sqm per litre in 2 Coats without dilution & 1 coat of efflorescent resistant primer 10sqm/litre/coat after cleaning the surface throughly and sealing all cracks with acrylic sealing compound as per the manufacturers specifications and directions of Engr-in-Charge Make :- Raincoat shall be of PlDlLlTE or equivalent. The product shall have following properties: Elongation > 100% as per ASTM D 412, Tensile strength : 2.5 Mpa as per ASTM D 412, Water Resistance conforming to SS 500, Crack bridging ability conforming to Class A4 as per EN 1062 Part 7, Positive hydrostatic pressure > 7 bar as per DIN 1048, Anti-carbonation property complying EN 1062 Part 6, RCPT conforming to ASTM C 1202.
M&L for providing water proofing plaster at the junction of wall and slab at chajjas, lintels etc, of average thickness 20mm in CM (1:3) with WPC, finished even and smooth without using extra cement all as specified and directed
Taking down cement plaster in any description incl racking out joints hacking for key and scrubbing down with water etc. specified and directed by Engr-in-Charge
M & L 15 mm thick rendering on fair faces of brickwork / concrete surface on wall in CM 1:4 using WPC @ 3% by weight of cement, all as specified and directed Note:- WPC shall be measured seperately.
M & L for PCC 1:3:6 type C1 (uisng 20mm graded aggregate) 75 mm thick as in Plinth, Path, floor with fair finish surface with out using extra cement all as specified.
Taking up or down steel tubing of 15 mm bore and connections, including cleaning for re-fixing or removal to store
Taking up or down steel tubing of 20 mm bore and connections, including cleaning for re-fixing or removal to store
S&F steel tubes of size 15mm bore (medium grade) galvanised with all fittingsand fixed complete to wall all as specified & directed by Engineer-in-charge.
S&F steel tubes of size 20 mm bore (medium grade) galvanised with all fittingsand fixed complete to wall all as specified & directed by Engineer-in-charge.
Fixing only steel tubes of size 15mm bore (medium grade) galvanised with all fittingsand fixed complete to wall all as specified & directed by Engineer-in-charge.
Fixing only steel tubes of size 20 mm bore (medium grade) galvanised with all fittingsand fixed complete to wall all as specified & directed by Engineer-in-charge.
Cutting chases, pinning in brick walls, making good to facing where required and pointing in cement mortar (1:3) and making good , cutting n.exc 10cm girth , all as specified
Dismantling water tanks of capacity exc 250 litres but n exc 500 litres and removing to store all as specified
Dismantling water tanks of capacity exc 500 litres but n exc 1000 litres and removing to store all as specified
Dismantling water tanks of capacity exc 1000 litres but n exc 2000 litres and removing to store all as specified
S & F rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of capacity 500 litre hoisted and fixed in position as specied and directed.
S & F rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of capacity 1000 litre hoisted and fixed in position as specied an directed.
S & F rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of capacity 2000 litre hoisted and fixed in position as specied an directed.
S & F in repair PVC valveless syphonic action type flushing cistern (Low or high level) of 10 litre capacity, white/coloured with inlet ball valve, float, handle including fixing brackets and 32 mm bore PVC flush pipe etc complete all as specified and directed.
S & F in repair ball valves suitable for 20 mm bore iron pipe high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball, screwed for iron pipe and fixed, (minimum weight 210 gms) all as specified and directed.
S & F in repair ball valves suitable for 15 mm bore iron pipe high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball, screwed for iron pipe and fixed, (minimum weight 455 gms) all as specified and directed.
S&F in repairs stop valves, 15 mm cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions all as specified and directed.
S & F in repairs PVC connection of 450 mm length, suitable for 15 mm bore pipe with PTMT nuts all as specified and directed.
S & F in repairs PVC connection of 600 mm length, suitable for 15 mm bore pipe with PTMT nuts all as specified and directed.
S&F in repairs PVC waste outlet pipe for 32/40mm dia WHB complete all as specified and directed.
S&F in repairs PVC waste outlet pipe for kitchen sink complete all as specified and directed.
S&F in repairs Wash basins, vitreous China (flat back or angle back type) any size, including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing and supply of waste pipe all as specified
S&F in repairs 15 mm dia Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed all as specified.
S&F in repairs Brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed
S&F in repairs 15mm dia bore fency type Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed
S&F in repairs CP two way bib taps screwed for iron pipe and fixed necessary fitting with and incl PVC connection all as specified and directed
S&F in repair tubular towel rail 20mm dia, D type 60cm long between flanges brass chromium plated, all as specified and directed.
S & F in repairs Plastic seat cover to EWC with aluminium hinging device all as specified and directed.
S&F in repairs of Vitreous China Urinal, half stall type, white complete including CP waste coupling, CP spreader etc all as specified.
Cleaning and removing all scale and dirt etc from tank of any type (RCC or PVC) and from mouths of circulating pipes exceeding 250 litre capacity and not exceeding 500 litre capacity all as specified and directed.
Cleaning and removing all scale and dirt etc from tank of any type (RCC or PVC) and from mouths of circulating pipes exceeding 500 litre capacity and not exceeding 1000 litre capacity all as specified and directed.
S&F in repair PVC water tank cover with fitting suitable for tank of capacity of 500 liters etc including device complete.
S&F in repair PVC water tank cover with fitting suitable for tank of capacity of 500 to 1000 liters etc including device complete.
Demolition stone slabs and tiles of any description or thickness in floors aprons laid and bedded and jointed in cement mortar.
M&L for Granite slab 20 mm thick machine cut bedded and jointed with grey cement and pointed and adhesive of pigment to match the shade incl cutting and polshing as directed by Engr-in-Charge
M&L for 20-25mm thick machine cut cuddappah stone slab flooring over cement screed bed laid and jointed with grey cment slurry mixed with pigment to match the shade of the slab incl grinding polishing complete all as specified.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations
S&F in repair plate rack made of stainless steel 1mm thick kitchen including fixing overall size 915mm x 915mm x 255 mm all as specified.
S&F in repairs Health faucet brass chromium plated with connecting decorative pipe including all accessories required for fixing of 15 mm bore of pipe all as directed.
S&F in repairs bathroom cabinet mirror (of approved pattern) of size 450mmx 350mm regular size with mirror and PVC shelves complete all as specified and directed by Engineer-in-Charge.
S& F in repairs Soap dish vitirous china fixed to plugs with chromium plated brass screws complete all specified and directed.
S&F in repairs sheet glass shelf assembly consisting of 5.5 mm thick sheet glass 12 cm wide with CP bracket guard and railing 60 cm long all as specified and directed.(Make : Jaguar, Cat Part No CAN -1173)
Dismantling floor, hearth or wall tiling including cement mortar bedding/complete and removing rubbish off the premises complete all as specified and directed.
M&L Coloured Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 300X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over 10 mm thick plastering in cm 1:4 all as specified.
M&L non-skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tiles exc 0.06 sqm but not exc 0.11 sqm in floor etc set and jointed in neat cement slurry to match the work using colour tiles over screed bed on bedding layer of mortar 15mm thick is CM 1:6 over cement concrete type B-0, 1:2:4 using 12.50mm graded stone aggregate as in floors 25 mm thick, all as specified and directed.
M & L for non skid ceramic coloured joint free tiles with matt finish, 7 to 8 mm thick ( square/ rectangular ) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in paste pigmented to tile shade over and including 15mm thick cement and sand screed (1:6) complete all as specified and directed.
S & F Vitrified ceramic coloured tiles 10mm thick (square/rectangular) area of each tile not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed or bedding in layer in cement mortar 1 :6 , set and jointed in neat cement lsurry and pointed in white or coloured cement to mathch the surfaces of tiles.
S & F in repairs water closet (Squat Pattern) complete incl provn of lime concrete bedding Orissa pattern size 580 x 440mm white integral foot rests (excluding flush pipe or flushing cisterns) including connection to trap and flushing pipe anti syphonage pipe etc complete and making good to floor.
S&F in repairs Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including connection to trap and flushing pipe anti syphonage pipe etc complete and making good to floor.
S&F in repairs grating square or circular 125mm dia of PTMT (minimum weight 100 gms, all as specified and directed.
Taking down Wall panelling / ceilling and similar work all as specified and directed
S&F Solid PVC Wall Lining consisting of 5mm thick wood grain printed PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing
5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing.
Taking down drain pipes (any size or pattern), including all fittings, T, bends,etc., including cleaning or refixing (measured overall as fixed along the centre line over fitting and accessories)
S&F PVC (SWR) pipes 110 mm dia single sockets, in any length rubber ring joints, laid in trenches or in floor all as specified and directed.
S&F PVC (SWR) pipes 75 mm dia single sockets, in any length rubber ring joints, laid in trenches or in floor all as specified and directed.
S&F PVC (SWR) 110mm dia bends any radius all as specified and directed.
S&F PVC (SWR) branch 110mm bore pieces, single ( single Y ) equal or unequal all as specified and directed.
S&F PVC (SWR) junction110mm bore single ( single t) equal or unequal all as specified and directed.
S&F PVC (SWR) 75 mm dia bends any radius all as specified and directed.
S&F PVC (SWR) junction 75 mm bore single ( single t) equal or unequal all as specified and directed.
S&F PVC (SWR) branch75 mm bore pieces, single ( single Y ) equal or unequal all as specified and directed.
M & L applying two coats of cement base paint to newly plastered surface of wall including preparation.
S P DEVELOPERS (BID ID -3089642)
A B S ENTERPRISES (BID ID -3095477)
visionenterprises (BID ID -3094280)
M/S JAYCONSTRUCTION CO (BID ID -3095674)
L.K.R.TIWARI CONSTRUCTION (BID ID -3094955)
S.R.M.K Enterprises (BID ID -3088735)
shree ram enterprises (BID ID -3094920)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .