Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-AOC | ₹1.1 Cr | L1 | Accepted-AOC Being L1. |
| 2 | L2₹1.3 Cr+₹15.4 L (14.0%)Rejected-Finance 01 KHUMRIYAL KUPWARA KHUMRIYAL KUPWARA KUPWARA JAMMU KASHMIR 193223 | KUPWARA | JAMMU AND KASHMIR | 193223 | ₹1.3 Cr+₹15.4 L (14.0%) | L2 | Rejected-Finance Other than L1. |
| 3 | L3₹1.3 Cr+₹16.7 L (15.2%)Rejected-Finance | ₹1.3 Cr+₹16.7 L (15.2%) | L3 | Rejected-Finance Other than L1. |
| 4 | L4₹1.4 Cr+₹28.2 L (25.6%)Rejected-Finance | ₹1.4 Cr+₹28.2 L (25.6%) | L4 | Rejected-Finance Other than L1. |
| 5 | L5₹1.4 Cr+₹29.9 L (27.1%)Rejected-Finance I 910 JAHANGIR PURI NEAR BY ANAND MAYA HOSPITAL NORTH WEST DELHI DELHI 110033 UDYAM DL 06 0040830 | NORTH DELHI | DELHI | 110033 | ₹1.4 Cr+₹29.9 L (27.1%) | L5 | Rejected-Finance Other than L1. |
Tender Value
₹1.5 Cr
EMD Value
₹2.2 L
Closing Date
9 Feb 2024, 6:00 pmClosed
CWE, HQ 134 Wks Engrs
HQ 134 Wks Engrs PIN-914134 C/o 26 APO
PROVN OF REPLACEMENT OF EXISTING OH 11 KV HT AND 433 KVA LT INTO UNDERGROUND CABLE NETWORK ALONGWITH ALLIED INFRA AT SHALATENG GARRISON UNDER AGE (I) CIF (K).
2024_MES_637260_1
134WE- 61(T) OF 2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
AGE (I) CIF (K)
As per tender documents
9 documents required · 9 mandatory
₹1,000
AGE (I) CIF (K)
₹2.2 L
Yes
12 Mar 2024
12 Jan 2024
12 Feb 2024
12 Jan 2024
9 Feb 2024
2 Feb 2024
13 Jan 2024 - 22 Jan 2024
Amount
Supply, laying, commissioning & testing XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 11000 volts grade, cross sectional area 185 Sqmm, 3 Core, complete all as specified and directed.
Supply, laying, commissioning & testing XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 11000 volts grade, cross sectional area 120 Sqmm, 3 Core, complete all as specified and directed.
Supply, laying, commissioning & testing XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 11000 volts grade, cross sectional area 95 Sqmm 3 Core, complete all as specified and directed. Note for Srl item No. 1 to 3 :- (a) Excavation, earth work, sand cushioning and PCC cable covers shall be measured and paid separately under respective items of this BOQ. (b) Cable shall be tested after laying/ fixing and rates for the same shall be deemed to include in the quoted rates.
M&L for cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories, suitable for 3 Core XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 Sqmm, complete all as specified and directed.
M&L for cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories, suitable for 3 Core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 Sqmm, complete all as specified and directed.
M&L for cable jointing kit for 11 KV (Earthed) grade cable for Outdoor termination heat shrink type joint complete with jointing material and accessories, suitable for 3 Core XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 Sqmm, complete all as specified and directed.
M&L for mild steel cross arms, channels, bracing, supports, clamps etc, fabricated from structured steel, sections including nuts, bolts, washers etc. and cutting to required length, bent to shape, drilling holes, fixed on poles or jointed by means of electric welding complete including painting with two coats of aluminium paint over a coat of red oxide zinc chrome primer after preparation of surface, complete all as specified and directed.
Supply, laying, commissioning & testing XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 6 Sqmm 4 Core, complete all as specified and directed. Note :- (a) Excavation, earth work, sand cushioning and PCC cable covers/ bricks cover shall be measured and paid separately under respective items of this BOQ. (b) Cable shall be tested after laying/ fixing and rates for the same shall be deemed to include in the quoted rates.
All as per Srl item No. 8.00 here-in-before, but cross sectional area of cable 10 Sqmm, 4 Core.
All as per Srl item No. 8.00 here-in-before, but cross sectional area of cable 16 Sqmm, 4 Core.
All as per Srl item No. 8.00 here-in-before, but cross sectional area of cable 25 Sqmm, 4 Core.
All as per Srl item No. 8.00 here-in-before, but cross sectional area of cable 35 Sqmm, 3.5 Core.
All as per Srl item No. 8.00 here-in-before, but cross sectional area of cable 50 Sqmm, 3.5 Core.
All as per Srl item No. 8.00 here-in-before, but cross sectional area of cable 70 Sqmm, 3.5 Core.
All as per Srl item No. 8.00 here-in-before, but cross sectional area of cable 95 Sqmm, 3.5 Core.
All as per Srl item No. 8.00 here-in-before, but cross sectional area of cable 120 Sqmm, 3.5 Core.
All as per Srl item No. 8.00 here-in-before, but cross sectional area of cable 150 Sqmm, 3.5 Core.
All as per Srl item No. 8.00 here-in-before, but cross sectional area of cable 185 Sqmm, 3.5 Core.
All as per Srl item No. 8.00 here-in-before, but cross sectional area of cable 240 Sqmm, 3.5 Core.
All as per Srl item No. 8.00 here-in-before, but cross sectional area of cable 300 Sqmm, 3.5 Core.
All as per Srl item No. 8.00 here-in-before, but cross sectional area of cable 400 Sqmm, 3.5 Core.
Supply, installation, commissioning and testing LT control panel board, oudoor type, double door, cubical type, padestal mounted, slopy roof, front and back both side opening, overall size not less than 1200x1000x450mm, CPRI approved, IP-52 having independent compartment for busbar, incoming feeder and each outgoing feeders, dust and vermin proof & lockable, factory made, fabricated out of 3.15mm thick CRCA sheet, suitable for 3 Phase 415 Volts 50 Hz AC supply, busbar chamber with copper busbar of 1000 Amps rating for 3 Phase and bus bar of same capacity for neutral, 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators-01 set inlcuding necessary copper cables of suitable size of MCCBs/ MCBs/ changeover switch/ inter connections, common earth busbar of GI strip 32x6mm at bottom with panel board at two earth terminals, cable glands with independent plates at bottom for each outgoing and incoming cables in cable alloy panel board and painted with powder coating in siemens grey colour and provision for the following incoming and outgoing accessories all as approved and comprising as under :- Location :- Main LT panel 1 Near MRS area.
OUTGOING :- (a) MCCB 4 Pole, 160 Amps, 36 KA, 415 Volts, Ics = 100%Icu. - 01 No. (b) MCCB 4 Pole, 350 Amps, 36 KA, 415 Volts, Ics = 100%Icu - 01 No. (c) MCCB 4 Pole, 63 Amps, 16 KA, 415 Volts, Ics = 100%Icu - 02 Nos. (d) Three phase timer switch 40 Amps - 01 No. (For street light) (e) Angle iron base frame as required size for above panel, total leg height 600mm and grouting in side PCC 150mm legs and made out of 50x50x6mm thick angle iron duly painted-01 No.
Supply, installation, commissioning and testing LT control panel board, oudoor type, double door, cubical type, padestal mounted, slopy roof, front and back both side opening, overall size not less than 1200x1000x450mm, CPRI approved, IP-52 having independent compartment for busbar, incoming feeder and each outgoing feeders, dust and vermin proof & lockable, factory made, fabricated out of 3.15mm thick CRCA sheet, suitable for 3 Phase 415 Volts 50 Hz AC supply, busbar chamber with copper busbar of 1000 Amps rating for 3 Phase and bus bar of same capacity for neutral, 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators-01 set inlcuding necessary copper cables of suitable size of MCCBs/ MCBs/ changeover switch/ inter connections, common earth busbar of GI strip 32x6mm at bottom with panel board at two earth terminals, cable glands with independent plates at bottom for each outgoing and incoming cables in cable alloy panel board and painted with powder coating in siemens grey colour and provision for the following incoming and outgoing accessories all as approved and comprising as under :- Location :- Main LT panel 2 Near MRS area.
OUTGOING :- (a) MCCB 4 Pole, 350 Amps, 36 KA, 415 Volts, Ics = 100%Icu. - 01 No. (b) MCCB 4 Pole, 250 Amps, 36 KA, 415 Volts, Ics = 100%Icu - 01 No. (c) MCCB 4 Pole, 200 Amps, 36 KA, 415 Volts, Ics = 100%Icu - 01 No. (d) MCCB 4 Pole, 100 Amps, 16 KA, 415 Volts, Ics = 100%Icu - 01 No. (e) MCCB 4 Pole, 63 Amps, 16 KA, 415 Volts, Ics = 100%Icu - 02 Nos. (f) Three phase timer switch 40 Amps - 02 No. (For street light) (g) Angle iron base frame as required size for above panel, total leg height 600mm and grouting in side PCC 150mm legs and made out of 50x50x6mm thick angle iron duly painted-01 No.
Supply, installation, commissioning and testing LT control panel board, oudoor type, double door, cubical type, padestal mounted, slopy roof, front and back both side opening, overall size not less than 1200x1000x450mm, CPRI approved, IP-52 having independent compartment for busbar, incoming feeder and each outgoing feeders, dust and vermin proof & lockable, factory made, fabricated out of 3.15mm thick CRCA sheet, suitable for 3 Phase 415 Volts 50 Hz AC supply, busbar chamber with aluminium busbar of 350 Amps rating for 3 Phase and bus bar of same capacity for neutral, 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators-01 set inlcuding necessary copper cables of suitable size of MCCBs/ MCBs/ changeover switch/ inter connections, common earth busbar of GI strip 32x6mm at bottom with panel board at two earth terminals, cable glands with independent plates at bottom for each outgoing and incoming cables in cable alloy panel board and painted with powder coating in siemens grey colour and provision for the following incoming and outgoing accessories all as approved and comprising as under :- Location :- LT panel near GOC office building.
OUTGOING :- (a) MCCB 4 Pole, 63 Amps, 16 KA, 415 Volts, Ics = 100%Icu - 02 Nos. (b) MCCB 4 Pole, 40 Amps, 16 KA, 415 Volts, Ics = 100%Icu - 02 Nos. (c) Angle iron base frame as required size for above panel, total leg height 600mm and grouting in side PCC 150mm legs and made out of 50x50x6mm thick angle iron duly painted-01 No.
Supply, installation, commissioning and testing LT control panel board, oudoor type, double door, cubical type, padestal mounted, slopy roof, front and back both side opening, overall size not less than 1200x1000x450mm, CPRI approved, IP-52 having independent compartment for busbar, incoming feeder and each outgoing feeders, dust and vermin proof & lockable, factory made, fabricated out of 3.15mm thick CRCA sheet, suitable for 3 Phase 415 Volts 50 Hz AC supply, busbar chamber with aluminium busbar of 600 Amps rating for 3 Phase and bus bar of same capacity for neutral, 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators-01 set inlcuding necessary copper cables of suitable size of MCCBs/ MCBs/ changeover switch/ inter connections, common earth busbar of GI strip 32x6mm at bottom with panel board at two earth terminals, cable glands with independent plates at bottom for each outgoing and incoming cables in cable alloy panel board and painted with powder coating in siemens grey colour and provision for the following incoming and outgoing accessories all as approved and comprising as under :- Location :- LT panel near gym hall building.
OUTGOING :- (a) MCCB 4 Pole, 160 Amps, 16 KA, 415 Volts, Ics = 100%Icu. - 03 Nos. (b) MCCB 4 Pole, 63 Amps, 16 KA, 415 Volts, Ics = 100%Icu - 03 Nos. (c) MCCB 4 Pole, 40 Amps, 16 KA, 415 Volts, Ics = 100%Icu - 02 Nos. (d) Angle iron base frame as required size for above panel, total leg height 600mm and grouting in side PCC 150mm legs and made out of 50x50x6mm thick angle iron duly painted-01 No.
Supply, installation, commissioning and testing LT control panel board, oudoor type, double door, cubical type, padestal mounted, slopy roof, front and back both side opening, overall size not less than 750x650x400mm, CPRI approved, IP-52 having independent compartment for busbar, incoming feeder and each outgoing feeders, dust and vermin proof & lockable, factory made, fabricated out of 3.15mm thick CRCA sheet, suitable for 3 Phase 415 Volts 50 Hz AC supply, busbar chamber with aluminium busbar of 350 Amps rating for 3 Phase and bus bar of same capacity for neutral, 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators-01 set inlcuding necessary copper cables of suitable size of MCCBs/ MCBs/ changeover switch/ inter connections, common earth busbar of GI strip 32x6mm at bottom with panel board at two earth terminals, cable glands with independent plates at bottom for each outgoing and incoming cables in cable alloy panel board and painted with powder coating in siemens grey colour and provision for the following incoming and outgoing accessories all as approved and comprising as under :- Location :- Dy GOC Office area.
OUTGOING :- (a) MCCB 4 Pole, 100 Amps, 16 KA, 415 Volts, Ics = 100%Icu. - 01 No. (b) MCCB 4 Pole, 63 Amps, 16 KA, 415 Volts, Ics = 100%Icu - 02 Nos. (c) MCCB 4 Pole, 40 Amps, 16 KA, 415 Volts, Ics = 100%Icu - 01 No. (d) Angle iron base frame as required size for above panel, total leg height 600mm and grouting in side PCC 150mm legs and made out of 50x50x6mm thick angle iron duly painted-01 No.
Supply, installation, commissioning and testing LT control panel board, oudoor type, double door, cubical type, padestal mounted, slopy roof, front and back both side opening, overall size not less than 750x650x400mm, CPRI approved, IP-52 having independent compartment for busbar, incoming feeder and each outgoing feeders, dust and vermin proof & lockable, factory made, fabricated out of 3.15mm thick CRCA sheet, suitable for 3 Phase 415 Volts 50 Hz AC supply, busbar chamber with aluminium busbar of 300 Amps rating for 3 Phase and bus bar of same capacity for neutral, 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators-01 set inlcuding necessary copper cables of suitable size of MCCBs/ MCBs/ changeover switch/ inter connections, common earth busbar of GI strip 32x6mm at bottom with panel board at two earth terminals, cable glands with independent plates at bottom for each outgoing and incoming cables in cable alloy panel board and painted with powder coating in siemens grey colour and provision for the following incoming and outgoing accessories all as approved and comprising as under :- Location :- Station HQ.
OUTGOING :- (a) MCCB 4 Pole, 63 Amps, 16 KA, 415 Volts, Ics = 100%Icu. - 02 Nos. (b) MCCB 4 Pole, 40 Amps, 16 KA, 415 Volts, Ics = 100%Icu - 01 No. (c) Angle iron base frame as required size for above panel, total leg height 600mm and grouting in side PCC 150mm legs and made out of 50x50x6mm thick angle iron duly painted-01 No.
Supply, installation, commissioning and testing LT control panel board, oudoor type, double door, cubical type, padestal mounted, slopy roof, front and back both side opening, overall size not less than 1200x100x450mm, CPRI approved, IP-52 having independent compartment for busbar, incoming feeder and each outgoing feeders, dust and vermin proof & lockable, factory made, fabricated out of 3.15mm thick CRCA sheet, suitable for 3 Phase 415 Volts 50 Hz AC supply, busbar chamber with aluminium busbar of 400 Amps rating for 3 Phase and bus bar of same capacity for neutral, 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators-01 set inlcuding necessary copper cables of suitable size of MCCBs/ MCBs/ changeover switch/ inter connections, common earth busbar of GI strip 32x6mm at bottom with panel board at two earth terminals, cable glands with independent plates at bottom for each outgoing and incoming cables in cable alloy panel board and painted with powder coating in siemens grey colour and provision for the following incoming and outgoing accessories all as approved and comprising as under :- Location :- TA buildings.
OUTGOING :- (a) MCCB 4 Pole, 100 Amps, 16 KA, 415 Volts, Ics = 100%Icu. - 01 No. (b) MCCB 4 Pole, 63 Amps, 16 KA, 415 Volts, Ics = 100%Icu - 01 No. (c) MCCB 4 Pole, 40 Amps, 16 KA, 415 Volts, Ics = 100%Icu - 03 Nos. (d) Angle iron base frame as required size for above panel, total leg height 600mm and grouting in side PCC 150mm legs and made out of 50x50x6mm thick angle iron duly painted-01 No.
Supply, installation, commissioning and testing LT control panel board, oudoor type, double door, cubical type, padestal mounted, slopy roof, front and back both side opening, overall size not less than 750x600x400mm, CPRI approved, IP-52 having independent compartment for busbar, incoming feeder and each outgoing feeders, dust and vermin proof & lockable, factory made, fabricated out of 3.15mm thick CRCA sheet, suitable for 3 Phase 415 Volts 50 Hz AC supply, busbar chamber with copper busbar of 400 Amps rating for 3 Phase and bus bar of same capacity for neutral, 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators-01 set inlcuding necessary copper cables of suitable size of MCCBs/ MCBs/ changeover switch/ inter connections, common earth busbar of GI strip 32x6mm at bottom with panel board at two earth terminals, cable glands with independent plates at bottom for each outgoing and incoming cables in cable alloy panel board and painted with powder coating in siemens grey colour and provision for the following incoming and outgoing accessories all as approved and comprising as under :- Location :- Signal buildings.
OUTGOING :- (a) MCCB 4 Pole, 200 Amps, 36 KA, 415 Volts, Ics = 100%Icu. - 01 No. (b) MCCB 4 Pole, 100 Amps, 16 KA, 415 Volts, Ics = 100%Icu - 01 No. (c) MCCB 4 Pole, 63 Amps, 16 KA, 415 Volts, Ics = 100%Icu - 04 Nos. (d) MCCB 4 Pole, 40 Amps, 16 KA, 415 Volts, Ics = 100%Icu - 01 No. (e) Angle iron base frame as required size for above panel, total leg height 600mm and grouting in side PCC 150mm legs and made out of 50x50x6mm thick angle iron duly painted-01 No.
Supply, installation, commissioning and testing LT control panel board, oudoor type, double door, cubical type, padestal mounted, slopy roof, front and back both side opening, overall size not less than 700x600x400mm, CPRI approved, IP-52 having independent compartment for busbar, incoming feeder and each outgoing feeders, dust and vermin proof & lockable, factory made, fabricated out of 3.15mm thick CRCA sheet, suitable for 3 Phase 415 Volts 50 Hz AC supply, busbar chamber with aluminium busbar of 400 Amps rating for 3 Phase and bus bar of same capacity for neutral, 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators-01 set inlcuding necessary copper cables of suitable size of MCCBs/ MCBs/ changeover switch/ inter connections, common earth busbar of GI strip 32x6mm at bottom with panel board at two earth terminals, cable glands with independent plates at bottom for each outgoing and incoming cables in cable alloy panel board and painted with powder coating in siemens grey colour and provision for the following incoming and outgoing accessories all as approved and comprising as under :- Location :- Near building No. P-17.
OUTGOING :- (a) MCCB 4 Pole, 100 Amps, 16 KA, 415 Volts, Ics = 100%Icu. - 01 No. (b) MCCB 4 Pole, 63 Amps, 16 KA, 415 Volts, Ics = 100%Icu - 02 Nos. (c) MCCB 4 Pole, 40 Amps, 16 KA, 415 Volts, Ics = 100%Icu - 02 Nos. (d) Angle iron base frame as required size for above panel, total leg height 600mm and grouting in side PCC 150mm legs and made out of 50x50x6mm thick angle iron duly painted-01 No.
Supply, installation, commissioning and testing LT control panel board, oudoor type, double door, cubical type, padestal mounted, slopy roof, front and back both side opening, overall size not less than 750x600x450mm, CPRI approved, IP-52 having independent compartment for busbar, incoming feeder and each outgoing feeders, dust and vermin proof & lockable, factory made, fabricated out of 3.15mm thick CRCA sheet, suitable for 3 Phase 415 Volts 50 Hz AC supply, busbar chamber with aluminium busbar of 200 Amps rating for 3 Phase and bus bar of same capacity for neutral, 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators-01 set inlcuding necessary copper cables of suitable size of MCCBs/ MCBs/ changeover switch/ inter connections, common earth busbar of GI strip 32x6mm at bottom with panel board at two earth terminals, cable glands with independent plates at bottom for each outgoing and incoming cables in cable alloy panel board and painted with powder coating in siemens grey colour and provision for the following incoming and outgoing accessories all as approved and comprising as under :- Location :- P-FRI.
OUTGOING :- (a) MCCB 4 Pole, 63 Amps, 16 KA, 415 Volts, Ics = 100%Icu - 01 No. (b) MCCB 4 Pole, 40 Amps, 16 KA, 415 Volts, Ics = 100%Icu - 04 Nos. (c) Angle iron base frame as required size for above panel, total leg height 600mm and grouting in side PCC 150mm legs and made out of 50x50x6mm thick angle iron duly painted-01 No.
Notes for Srl item Nos 22.00 to 31.00 of this BOQ above :- (a) All MCCBs will measured and paid separately under relevant items of this BOQ. (b) Rates of interconnecting copper/ aluminium cable alongwith necessary copper/ aluminium lugs shall be deemed to include in the quoted rates (c) The dimension/ size of panel is approximate size only. The contractor should obtain necessary approval/ layout/ drawing/ general arrangements for panel from Engineer-in-Charge/ AGE (I) prior to commencement of work. (d) Cost for connecting of existing old UG cable of any size/ type to new incoming/ outgoing terminals by cutting the required length, addition/ alteration and provision of necessary cable lugs, cable glands, nuts, bolt & washer, ammeter, voltmeter, angle iron, timer switch, CTR, indicator LED etc shall be deemed to inlcude in the quoted rates.
S&F MCCB 4 Pole, current rating 630 Amps, adjustable type, over load and short circuit with microprocessing release setting, breaking capacity 50 KA at 415 Volts, 50 Hz, complete all as specified and directed.
All as per Srl item No. 33.00 here-in-before, but MCCB 4 Pole, 350 Amps, breaking capacity 36 KA.
All as per Srl item No. 33.00 here-in-before, but MCCB 4 Pole, 250 Amps, breaking capacity 36 KA.
All as per Srl item No. 33.00 here-in-before, but MCCB 4 Pole, 200 Amps, breaking capacity 36 KA.
All as per Srl item No. 33.00 here-in-before, but MCCB 4 Pole, 160 Amps, breaking capacity 36 KA.
All as per Srl item No. 33.00 here-in-before, but MCCB 4 Pole, 100 Amps, breaking capacity 16 KA.
All as per Srl item No. 33.00 here-in-before, but MCCB 4 Pole, 63 Amps, breaking capacity 16 KA.
All as per Srl item No. 33.00 here-in-before, but MCCB 4 Pole, 40 Amps, breaking capacity 16 KA.
Dismantling and taking down the existing LT/ HT insulators of any type, from any existing position, complete all as specified and directed.
Dismantling and taking down the existing ACSR or ACC conductors of any description, from any position and any height, complete all as specified and directed.
Dismantling cross arms of MS channel or angle etc. of any description and type, from any position and height, complete all as specified and directed.
Dismantling and taking up stay assembly of any type, complete all as specified and directed. Note :- Excavation and earthwork shall be measured and paid separately under respective items of this BOQ.
S&F LT busbar panel board with 4 pole 40 Amps incomer MCCB, breaking capacity 16 KA, outdoor type, door cubical type, slopy roof, front back, both side opening, padestal mounted, overall size not less than 600x450x250mm, CPRI approved, IP-48 having independent compartment for busbar, incoming feeder and each outgoing feeders dust and vermin proof and lockable, factory made, fabricated out of 3.15mm thick CRCA sheet suitable for 3 phase 415 Volts, 50 Hz, AC supply, busbar chamber with aluminium bus bar of 150 Amps rating for 3 phase and busbar of same capacity for neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators-01 set including necessary copper cables of suitable size for MCCBs/ MCBs/ changeover switch/ inter connections, common earth busbar of GI strip 32x6mm at bottom with independent plates at bottom for each outgoing and incoming cables in cable alloy panel board and painted with powder coating in siemens grey colour and provision for the following incoming and outgoing all accessories, complete all as specified and directed.
Notes :- (a) All MCCBs will measured and paid separately under relevant items of this BOQ. (b) Rates of interconnecting copper/ aluminium cable along with necessary copper/ aluminium lugs shall be deemed to include in the quoted rates (c) The dimension/ size of panel is approximate size only. The contractor should obtain necessary approval/ layout/ drawing/ general arrangements for panel from Engineer-in-Charge/ AGE (I) prior to commencement of work. (d) Cost for connecting of existing old UG cable of any size/ type to new incoming/ outgoing terminals by cutting the required length, addition/ alteration and provision of necessary cable lugs, cable glands, nuts, bolt & washer, ammeter, voltmeter, angle iron, timer switch, CTR, indicator LED etc shall be deemed to inlcude in the quoted rates.
M&L for earthing complete with galvanised steel earth plate electrode of size 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below from normal ground level), connecting to the galvanised iron earth strip of size 25x4mm by means of bolts, nuts, check nuts and washers of galvanised iron and earth lead protected by 40mm bore GI pipe, medium grade including provision of conrete pit PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) with 40mm thick cover of RCC (1:2:4) type B-1, reinforced with XPM (weight not less than 4 Kg/Sqm) and frame of angle iron 25x25x3mm with lugs-02 Nos and with 6mm dia MS bar handle, made to shape, 20mm bore GI light grade pipe for watering perforated at bottom 1.50 mtr long, placed on top edge of earth plate and including common salt and charcoal filling, test point with fixing arrangements, funnel, wire mesh and earth work in hard/ dense soil, returning, filling in and removal of surplus soil to a distance not exceeding 50 mtr, complete as per electrical plate No. 3 of MES SSR Part-I (2009), complete all as specified and directed. Note :- The earthing will be tested after completion, if desire results not achieved, the contractor redo the earthing and rates for the same shall be deemed to include in the quoted rates.
All as per Srl item No. 46.00 here-in-before, but using galvanised iron strip of size 32x6mm as earthing lead.
S&F street light bracket, made out of GI pipe of 32/40mm bore, light grade, 1.2 mtr long, bend to shape as required and suitable for security/ street light fitting, fixed with and inlcuding MS clamps-02 Nos of suitable size, nuts bolts, washers and one coat of anti corrosive primer and two coats of aluminium paint, complete all as specified and directed.
S&F thermoplastic cable junction box/ distribution board, IP-65 with metric knockouts for cable entry of size 10-25 Sqmm 4 Core including fastening clamp with LT pole, box size 333x233x120mm, hinged cover with locking arrangements inlcuding with terminals TPN strip with 01 No. MCB SP 6 Amps, complete all as specified and directed.
M&L for sub main wiring using FR insulated unsheathed, multistand copper conductor FR-LSH PVC cable 2 runs of size 1.5 Sqmm for phase and neutral and 1.5 Sqmm for earthing, drawn hrough rigid PVC conduit of suitable size, fixed on pole for connection from junction box to light fittings, complete all as specified and directed. Notes :- (a) Phase should be Red/ Yellow/ Blue and neurtal should be black and earthing wire should be green in colour. (b) Two runs of cable for phase / neutral and one run for cable earth including PVC conduit will be measured and paid as one unit length.
Excavation in trenches, not exc 1.5 mtr wide and not exc 1.5 mtr in depth for laying/ taking out of LT/ HT cables, stay assembly, foundation of pole, for ducts etc and getting out in soft/ loose soil, complete all as specified and directed.
Returning, filling in trenches including spreading, leveling and well ramming in layers not exc 25cm thick, complete all as specified and directed.
Removing excavated soil to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point, complete all as specified and directed.
M&L for dry river sand, laid in trenches for cable protection, as 15cm thick below the cable and 8cm thick above the cable, complete all as specified and directed. Note :- Punned thickness of sand shall be measured and paid.
Supply and laying brick conventional size 230x110x75mm, locally available as protection of cable, laid in trenches, complete all as specified and directed.
M&L for cable jointing kit for 1.1 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories, suitable for 4 Core LT XLPE armoured aluminium conductor cable of size 6 Sqmm to 16 Sqmm and including testing after completion, complete all as specified and directed.
All as per Srl item No. 56.00 here-in-before, but size of cable 25 to 50 Sqmm, 3.5/4 Core.
All as per Srl item No. 56.00 here-in-before, but size of cable 70 to 120 Sqmm, 3.5 Core.
All as per Srl item No. 56.00 here-in-before, but size of cable 150 to 185 Sqmm, 3.5 Core.
All as per Srl item No. 56.00 here-in-before, but size of cable 240 to 300 Sqmm, 3.5 Core.
M&L for cable end jointing kit for 1.1 KV grade cable for indoor/ outdoor end joint, heat shrink type complete with jointing material and accessories, suitable for 3.5/4 Core LT XLPE armoured aluminium conductor cable of size 25 Sqmm to 50 Sqmm and including testing after completion, complete all as specified and directed.
All as per Srl item No. 61.00 here-in-before, but size of cable 70 to 120 Sqmm, 3.5 Core.
All as per Srl item No. 61.00 here-in-before, but size of cable 150 to 185 Sqmm, 3.5 Core.
All as per Srl item No. 61.00 here-in-before, but size of cable 240 to 300 Sqmm, 3.5 Core.
M&L for 150mm bore GI pipe, heavy grade, as in protection of LT/ HT XLPE cable for road crossing and supporting to cable and fixing with panel, wall, pole with and including suitable MS clamps of any number as required at site and directed by EIC, complete all as specified and directed.
M&L for 100mm bore GI pipe, medium grade, as in protection of LT/ HT XLPE cable for road crossing and supporting to cable and fixing with panel, wall, pole with and including suitable MS clamps of any number as required at site and directed by EIC, complete all as specified and directed.
All as per Srl item No. 66.00 here-in-before, but 80mm bore GI pipe, medium grade.
All as per Srl item No. 66.00 here-in-before, but 50mm bore GI pipe, medium grade.
All as per Srl item No. 66.00 here-in-before, but 25mm bore GI pipe, medium grade.
M&L for precast cement concrete solid building bolcks or slabs 10cm thick of any size in PCC 1:2:4, type B-1 (using 20mm graded crushed stone aggregate), with plain or interlocking joints as directed, setting in cement mortar 1:4 as in roads, path etc, complete all as specified and directed.
M&L for plain cement concrete 1:3:6, type C-2 (using 40mm graded crushed stone aggregates) as in beds plates, coping and the like and including weathering, slightly rounded or chamfered angles and throating including necessary formwork for rough finished surfaces, finished all exposed surfaces of concrete even and fair, complete all as specified and directed.
M&L for road cutting for cable/ GI pipe crossing and cutting with machine or any mechanical method, not exceeding 0.45 in width and not exceeding 0.90 mtr in depth, complete all as specified and directed.
M&L for embedding and fixing of HT/ LT cable route indicator, maker dia 150/ 100mm and thickness 3mm, round shape with corrosion resistant made by stainless steel, complete all as specified and directed. Notes :- (a) Excavation and earth work shall be deemed to include in quoted rates. (b) PCC shall be measured and paid separately under relevant item of this BOQ.
Notes :- An amount of Rs. 93,300.00 on account of Credit Schedule for Schedule 'A' Part-II shall be deducted from total quoted amount of BOQ to arrive at the contract sum.
M/S MIR & CO
Rajindera Enterprises
RAVI KUMAR
SATISH AND CO
M/S Sky Engineers
CHINAR CONSTRUCTION TRADERS
M/S Noor Mohammad Shalla
M/S SHRI RAM BUILDERS
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .