| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹19.5 LAccepted-AOC DHARAM SALA SINGHAN CHADOORA DISTT BUDGAM J K | CHADOORA | BUDGAM | JAMMU AND KASHMIR | L-1 | Accepted-AOC Lowest and Reasonable | |
| 2 | L-2₹21.8 L+₹1.0 L (4.88%)Rejected-Finance 0 GHULAM MOHAMMAD AND CO 0 GURUDAWARA II RAWALPORA SRINAGAR JAMMU AND KASHMIR RAWALPORA SRINAGAR JAMMU KASHMIR 190001 | SRINAGAR | JAMMU AND KASHMIR | 190001 | L-2 | Rejected-Finance Other than Lowest | |
| 3 | L-3₹22.0 L+₹1.1 L (5.49%)Rejected-Finance | L-3 | Rejected-Finance Other than Lowest | |
| 4 | L-4₹22.2 L+₹1.3 L (6.40%)Rejected-Finance | L-4 | Rejected-Finance Other than Lowest | |
| 5 | L-5₹22.2 L+₹1.3 L (6.46%)Rejected-Finance KRAL PORA BAGH I MEHTAB NEAR MANCHOWA PETROL PUMP DISTRICT BUDGAM 190019 J K | BUDGAM | BUDGAM | J K | 190019 | L-5 | Rejected-Finance Other than Lowest |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
22 Jul 2024, 6:00 pmClosed
GE (AF) Srinagar
Garrison Engineer (AF) Air Force Station Srinagar 190 007
REPAIR / MAINTENANCE OF GOD / LA / RMU, 2/4 POLE STRUCTURE, CABLE JOINTS AND OTHER ELECTRIFICATION SYSTEM UNDER AOR OF GE (AF) SRINAGAR
2024_MES_663276_1
GE (AF)/SGR-20/2024-25
Open Tender
Civil Works
Item Rate
180 days
AOR of GE AF Srinagar
Please refer NIT and Tender Documents
9 documents required · 9 mandatory
₹500
GE (AF) Srinagar
₹80,000
Yes
2 Sept 2024
1 Jul 2024
24 Jul 2024
1 Jul 2024
22 Jul 2024
15 Jul 2024
Amount
Note:- For all Items of this BOQ:- Work has to be executed for external electrification work, Electric shut will require to execute certain items of this Schedule, Contractor is require to intimate Engineer-in-Charge at least 7 days in advance whenever shut down is require, Engineer-in-Charge will intimate to contractor four days in advance from the date of shut down provided by them. Contractor will manage manpower / tools / plant etc accordingly. No compensation etc will be paid by department in case shut down not provided by the department due to any reason. In case of any dispute Decision of Accepting officer shall be final binding & conclusive.
Excavating in trenches in any type of soil not exc.1.5 m wide and not exc. 1.5 m in depth for foundation poles, stays, laying of cables etc for shaft, wells, cesspits, manholes, peir holes, etc or not exc. 10 Sqm on plan and getting out, complete all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exc. 25 cm thick, using excavated soil, complete all as specified and directed.
Removing excavated soil to a distance not exc. 50 metre and depositing where directed at a level n.exc 1.5m above the starting point, complete all as specified and directed.
Supply and erect in true vertical position 9.00 m long steel tubular swaged poles complete with cast iron base plate, finial plug, bolts, nuts & screws as specified type 410 SP-31, painting of exposed surface of pole with two coats of aluminium paint over one coat of red oxide primer, painting up to 1.20 m height above coping in alternate band ( 20 cm wide strip) with two coat synthetic enamel paint over one coat red oxide primer, marking Pole No. in 10 cm dia coloured yellow circle, painting of pole below ground level with two coat anticorrosive paint including taking down old swaged pole, complete all as specified and directed. (Note:- Excavation, earth work and PCC will be measured and paid separately in respective items.)
Supply and erect in true vertical position 11.00 m long steel tubular swaged poles complete with cast iron base plate, finial plug, bolts, nuts & screws as specified type 410 SP-55, painting of exposed surface of pole with two coats of aluminium paint over one coat of red oxide primer, painting up to 1.20 m height above coping in alternate band ( 20 cm wide strip) with two coat synthetic enamel paint over one coat red oxide primer, marking Pole No. in 10 cm dia coloured yellow circle, painting of pole below ground level with two coat anticorrosive paint including taking down old swaged pole, complete all as specified and directed. (Note:- Excavation, earth work and PCC will be measured and paid separately in respective items.)
S&F in repairs cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 sqmm, complete all as specified and all directed.
S&F in repairs cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sqmm, complete all as specified and all directed.
S&F in repairs cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 sqmm, complete all as specified and all directed.
S&F in repair cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sqmm, complete all as specified and directed.
S&F in repairs cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 sqmm, complete all as specified and all directed.
S&F in repairs cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sqmm, complete all as specified and all directed.
M&L for cleaning of surrounding area of E&M installation around the bldg , transformer, GOD LT panel by grass cutting manually or mechanically (Bush cutter) as per requirement basis and trimming as directed by Engr-in-Charge, including taking out all shrubs, saplings with bushes and any type of vegetation and removing from site, complete all as specified and directed.
M&L for Mild steel framed work such as grills, gratings, etc with ends of bars shouldered and / or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed ballusters walk ways; railings; frame work at installation and similar work conforming to Fe.290. Gde-E-165 including two coats of synthetic enamel paint over a coat of red oxide primer and dismentling old mild steel work, complete all as specified and directed.
S&F in repairs 6 mm thick mild steel plain / chequered plate cut to size and fixed as in cable duct cover, complete all as specified and directed.
S&F in repairs lightning arrestor (set of three) HT metal oxide surge arrester polymeric type complete with all fittings, rated voltage 12 KV continuous operating voltage 11 KV, normal discharge current 10 KA, 65 KV discharge capacity etc, confirming to IEC-600994-2001, complete all as specified and directed.
Supply, laying, jointing and testing XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, HT underground cable ISI marked with aluminium conductor 11000 volt grade (Earthed) of size 120 Sqmm 3 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc. including taking down old HT UG cable and removal brick cable cover, complete all as specified and directed. Note:- Earthwork, sand cushion, cable cover if required will be measured and paid separately under respective items of this Schedule.
Supply, laying, jointing and testing XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, HT underground cable ISI marked with aluminium conductor 11000 volt grade (Earthed) of size 95 Sqmm 3 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc. including taking down old HT UG cable and removal brick cable cover, complete all as specified and directed. Note:- Earthwork, sand cushion, cable cover if required will be measured and paid separately under respective items of this Schedule.
Supply, laying, jointing and testing XLPE insulated of cross sectional area 10 Sqmm 2 Core, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium conductor 1100 volt grade laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc including taking out existing old unserviceable cable, complete all as specified and directed. Note:- Earthwork, sand cushion, cable cover if required will be measured and paid separately under respective items of this Schedule.
All as per Ser item No 19.00 here in above but cross sectional area 16 Sqmm 2 core.
All as per Ser item No 19.00 here in above but cross sectional area 16 Sqmm 4 core.
All as per Ser item No 19.00 here in above but cross sectional area 25 Sqmm 3.5 core.
All as per Ser item No 19.00 here in above but cross sectional area 35 Sqmm 3.5 core.
All as per Ser item No 19.00 here in above but cross sectional area 50 Sqmm 3.5 core.
All as per Ser item No 19.00 here in above but cross sectional area 70 Sqmm 3.5 core.
All as per Ser item No 19.00 here in above but cross sectional area 95 Sqmm 3.5 core.
All as per Ser item No 19.00 here in above but cross sectional area 120 Sqmm 3.5 core.
All as per Ser item No 19.00 here in above but cross sectional area 150 Sqmm 3.5 core.
Laying only XLPE insulated of cross sectional area 10 Sqmm to 16 Sqmm, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium conductor 1100 volt grade laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc using retrived from and including taking out existing old cable, complete all as specified and directed. Note:- Earthwork, sand cushion, cable cover if required will be measured and paid separately under respective items of this Schedule.
All as Ser per Item No 29.00 here in above but cable of size 25 Sqmm to 35 Sqmm 3.5 core.
All as Ser per Item No 29.00 here in above but cable of size 50 Sqmm to 70 Sqmm, 3.5 core.
All as Ser per Item No 29.00 here in above but cable of size 95 Sqmm 3.5 core.
All as Ser per Item No 29.00 here in above but cable of size 120 Sqmm to 150, 3.5 core.
Supply and Laying of bricks well burnt sub class B (old size) laid flat for cable protection width equal to the length of bricks, complete all as specified and directed.
Laying Only of bricks retrieved from existing site, laid flat for cable protection width equal to the length of bricks, complete all as specified and directed.
M&L for dry & clean sand cushioning in trenches spreading and consolidation 8 cm thick before laying the cable and 15 cm of sand after laying the cable and punned the same up 18 cm, complete all as specified and directed. (Note:- Only punned thickness shall be measured and paid.)
M&L for cutting of existing road surfaces up 100 mm deep & 300 mm wide and making good disturbed portion with 100 mm thick plain cement concrete 1:2:4 type B-1 (using 40mm graded crushed stone aggregate), complete all as specified and directed by Engineer-in-Charge.
S&F in repairs 50 mm dia bore mild steel galvanized iron tubes, 'light grade' with all fitting and laid in trenches or fixed to pole or laid in floors for protection of cable, complete all as specified and directed.
S&F in repairs 80 mm dia bore mild steel galvanized iron tubes, 'light grade' with all fitting and laid in trenches or fixed to pole or laid in floors for protection of cable, complete all as specified and directed.
Taking down unserviceable LED light fitting of capacity 30 / 45 Watt from Pole / wall or any other location, any height, any situation, and replacement of electronic driver with new driver of same capacity, tightening the loose connection and made item functional, refixing / rehanging the fitting in existing location or other location (as directed) and testing, complete all as specified and directed. Note:- Necessary T & P like ladder / Boom Vehicle, tools etc as required for taking down & fixing of light shall be provided by contractor without any extra cost.
All as Ser per Item No 40.00 here in above but replacement of electronic driver sutable for LED light fitting of 50 / 60 Watt.
All as Ser per Item No 40.00 here in above butreplacement of electronic driver sutable for LED light fitting of 100 Watt.
All as Ser per Item No 40.00 here in above but replacement of electronic driver sutable for LED light fitting of 150 Watt.
S&F in repairs LED street Light fitting 60 Watt, system efficiency not less than 110 lumen / watt, IP66 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, fitted in cast aluminium housing with SS screws fixed on existing bracket & connecting, complete all as specified and directed.
S&F in repairs LED, post top lantern, 40 Watt, 230 volts AC, out door type, with decorative post 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp fixed over existing pole, complete all as specified and directed.
M&L for preparation of old painted steel surface of LT feeder pillar Box, 440 Volts, 3 phase of any size / location and applying two coats of synthetic enamel paint, complete all as specified and directed.
M&L for Sub main wiring for connecting street light fitting from junction box with two single core, PVC insulated, (ISI marked) , unsheathed, 1100 volts grade, 2.5 Sqmm multistranded copper conductor cable drawn into and including suitable size PVC conduit 20 mm dia ISI marked medium grade with all accessories and including one single core, 2.5 Sqmm PVC insulated multistranded unsheathed 1100 volts grade copper conductor cable as earth wire including taking down cable, complete all as specified and directed. Note: 2 Runs of main cable and one run earth wire with conduit will be measured as one RM for payment.
Supply, installation testing & commissioning street light control box, factory made, weather and vermin proof having size 200 x 250 x 80 mm made out of 2.00 mm thick CRCA sheet, comprising of MCB SP 10A, C curve 10 KA breaking capacity 01 No's, 16 Amp 230 volt rated aluminium bus bar with mounting rail fixed on porcelein insulator, making holes on strips for connecting cables and fixing of bus bar chamber on street light pole with and including MS clamp of size 25 x 5 mm including nut, bolts washers duly painted with 2 coats of enamel paint over a coat of red oxide primer including taking down old box , complete all as specified and directed.
M&L for renewal of earthing complete with galvanized iron earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m deep below normal ground connected to galvanized steel wire 4 mm dia by means of bolts nuts check nuts and washer of galvanized steel, watering pipe of 20 mm bore, galvanised iron, medium grade, and 15 mm bore galvanised iron light grade for earth wire protection including all excavation earth work in any type of soil, PCC pit in PCC 1:2:4 type B-1 and RCC 1:2:4, type B1 for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm), with charcoal, salt, funnel complete all as shown in the electrical plate No 3 of SSR part –I and testing on completion, complete all as specified and directed. Note:- Quoted rates shall be deemed to include for earth wire with protection pipe up to 7.5m length.
M&L for renewal of earthing complete with galvanized iron earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m deep below normal ground connected to galvanized steel strip of size 32 x 6 mm by means of bolts nuts check nuts and washer of galvanized steel, watering pipe of 20 mm bore, galvanised iron, medium grade, and 40 mm bore galvanised iron light grade for earth wire protection including all excavation earth work in any type of soil, PCC pit in PCC 1:2:4 type B-1 and RCC 1:2:4, type B1 for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm), with charcoal, salt, funnel complete all as shown in the electrical plate No 3 of SSR part –I and testing on completion, complete all as specified and directed. Note:- Quoted rates shall be deemed to include for earth wire with protection pipe up to 7.5m length.
M&L for renewal of earthing complete with copper earth plate electrode 600 mm x 600 mm x 3 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m deep below normal ground connected to copper strip of size 20 x 3 mm by means of bolts nuts check nuts and washer of galvanized steel, watering pipe of 20 mm bore, galvanised iron, medium grade, and 32 mm bore galvanised iron light grade for earth wire protection including all excavation earth work in any type of soil, PCC pit in PCC 1:2:4 type B-1 and RCC 1:2:4, type B1 for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm), with charcoal, salt, funnel complete all as shown in the electrical plate No 3 of SSR part –I and testing on completion, complete all as specified and directed. Note:- Quoted rates shall be deemed to include for earth wire with protection pipe up to 7.5m length.
S&F timer distribution board with analog time switches complete of rating 65 Amps 3 pole 230 Volts 415 volt including taking down existing, complete all as specified and directed.
M&L for preparation of old painted surface of steel tubular poles height approximately 9.5m above GL including cross arms and bracings and applying two coats aluminium paint and rewriting pole number with synthetic enamel paint, complete all as specified and directed.
M&L for preparation of old painted surface of steel tubular poles height approximately 7 to 7.5 m above GL including cross arms and bracings and applying two coats aluminium paint and rewriting pole number with synthetic enamel paint, complete all as specified and directed.
S&F in replacement Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint on 4/6 pole 11 KV HT structure, complete all as specified and directed.
M&L for Aluminium conductor, steel reinforced (ACSR) Code name : Weasel conductor for HT feeders on steel tubular / PCC poles, stretching without kinks and bends including binding wire including taking down old conductor of any type shape and size, complete all as specified.
Deployment of manpower / tools etc for Restretching / refixing the existing LT OH / Lines ACSR conductor of any type and size including disconnecting binding wire on insulator, rebinding properly to avoid tension / fitting bending of poles, complete all as specified and directed. Note:- Each line of conductor will be measured & paid separately.
Deployment of manpower / tools / machinery / plant for Dehydration / filtration of transformer oil of transformers, etc of various capacities installed at different locations by disconnecting plants electrically for recirculation existing transformer oil with trolley mounted filtration plant till dielectric strength not less than 50 KV when measured at 2.5 mm gap for one minute, complete all as specified and directed. Note- Quoted rates shall be deem to include for following :- (i) Oil for each transformer shall be tested after filtration and test result will be recorded before & after filtration of oil and signed by Engineer-in-Charge & contractor. (ii) Contractor should make his own arrangement for oil filtration plant including transportation complete. (iii) New transformer oil as required shall be measured and paid separately under respective item as supply only.
Supply & filling Power Transformer Oil for toping up the level of oil having dielectric strength 50 KV at 4 mm gap confirming to IS-335, complete all as specified and directed. Note:- Transformer oil shall be supplied in sealed Containers.
S&F in repairs pin type, porcelain, vitreous, white / brown / green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised nut, 100 mm height, 65 mm dia for 1100 volts grade, complete all as specified and directed.
S&F in repairs pin type, porcelain, vitreous, white / brown / green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised nut, 150 mm height, 150 mm dia for 1100 volts grade, complete all as specified and directed.
S&F in repairs disc type, porcelain, vitreous white / brown / green insulator including one galvanised mild steel straps washers insulator bolts, washers , nut, 145 mm height, 255 mm dia for 1100 volts grade, complete all as specified and directed.
S&F in repairs shakle type, porcelain, vitreous, white / brown / green insulator including one galvanised mild steel straps washers insulator bolts, washers , nut, 100 mm height, 115 mm dia for 1100 volts grade, complete all as specified and directed.
S&F in repairs stay assembly for LT pole complete with accessories as shown in Electrical Plate No 1 (Dia of stay rod 16 mm), complete all as specified and directed.
M&L for PCC, 1:4:8, type D-2 (using 40 mm graded crushed stone aggregate) as in foundation footing / mass concrete etc., complete all as specified and directed.
M&L for cement concrete 1:3:6, type C-1 (using 20 mm graded crushed stone aggregate) as in coping for pole and the like, weathering, slightly rounded or chamfered angles including necessary form work, complete all as specified and directed.
S&F in repairs MCCB 4 pole, 63 Amps with breaking capacity 16 KA, 415 volts, fixed in existing panel & connecting, complete all as specified and directed.
S&F in repairs MCCB 4 pole, 100 Amps with breaking capacity 16 KA, 415 volts, fixed in existing panel & connecting, complete all as specified and directed.
S&F in repairs MCCB 4 pole, 160 Amps with breaking capacity 25 KA, 415 volts, microprocessor release type, fixed in existing panel & connecting, complete all as specified and directed.
S&F in repairs MCCB 4 pole, 200 Amps with breaking capacity 25 KA, 415 volts, microprocessor release type, fixed in existing panel & connecting, complete all as specified and directed.
S&F in repairs MCCB 4 pole, 250 Amps with breaking capacity 25 KA, 415 volts, microprocessor release type, fixed in existing panel & connecting, complete all as specified and directed.
S&F in repairs MCCB 4 pole, 400 Amps with breaking capacity 25 KA, 415 volts, microprocessor release type, fixed in existing panel & connecting, complete all as specified and directed.
Supply and installation, testing, commissioning, factory made, CPRI approved, outdoor type, LT Feeder pillar board (kiosk type), confirming to IS 5039 with IP-54 protection, made out of 3.15 mm thick CRCA sheet , 415 Volt, 3 phase , 50 HZ supply, mounted on and including MS angle section 40 x 40 x 5 mm frame with front openable, double door with provision of locking arrangement dust & varmin proof , gasket, TPN busbar shall be insulated with colour coated heat shrinkable sleeves and shall be mounted on proper insulator, gland, welding hinges of dust proof, overall powder coated, including taking down old Feeder pillar board complete all as specifed and directed & Connisting of the following switchgear:- (a) Solid aluminium bus bar 300 Amp for 3 phase , 150 Amp for neutral - 01 set (b) MCCB 4 Pole , 200 Amps, rupturing capacity 25 kA, 440 Volts, adjustable type - 01 Nos as incoming (c) MCCB 3 Pole , 63 Amps, rupturing capacity 16 kA, 440 Volts, adjustable type - 02 Nos as outgoing
S&F in replacement GI Bracket made of 40mm dia GI pipe, medium grade, 1.5m long suitable for street light for steel / RCC pole as per site requirement including suitable nut, bolt, washers and clamps, complete all as specified and directed.
S&F in replacement PVC seperator suitable for 1100V four ACSR Conductor feeder, complete all as specified and directed.
Deployment of manpower / tools etc for maintenance of gang operated air break isolators switch out door type 9 / 12 insulators double stack, triple pole, rotating type double break per pole for 11000 volts, 3 phase, 50 Hz, AC supply system having 200 / 400 Amps capacity by oiling, greasing, adjustment of lever and making the same smooth functional, complete all as specified and directed.
S&F in replacement male contact/moving contact for gang operated air break device 11 KV, complete all as specified and directed.
S&F in replacement female contact /fix contact jaw for gang operated air break device 11 KV, complete all as specified and directed.
S&F in replacement Air break gang operated switch current rating 200Amps with 12 Nos insulators outdoor type, triple pole, mechanically operated, suitable for vertical installation, single break, provided with locking arrangement, consisting of MS Channel, HT post type insulator copper alloy, high pressure, assembly drop out fuses, operating rod 25mm dia GI pipe, medium grade for operating from 1.2 m above GL complete including drop out fuses conforming to IS rated voltage 11 KV, complete all as specified and directed.
Surface dressing n exc 15 cm deep in any type of soil, including trimming of ground, to remove vegetation and / or small inequalities, complete all as specified and directed.
M&L for spreading of clean & dry stone aggregate of nominal size not more than 20 mm (free from organic impurities) laid around 4 / 6 pole HT structure / surrounding area of outdoor RMU, manually without damaging any equipments, cable or parts, spreading & leveling of finished gravel uniformly in layers n. exc 150 mm thick, complete all as specified and directed.
S&F in repairs Anti climbing devices spikes type fabricated out of MS bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole, complete all as specified and directed.
S&F in repairs HT Danger notice plate of size 250 mm x 200 mm x 1.6 mm thick of mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal red colour and fixed to pole with MS clamps, bolts and nuts of approved size, complete all as specified and directed.
Supply and installation, testing, commissioning, factory made, bus bar chamber of size 1000 mm x 900 mm x 600 mm size, CPRI approved, outdoor type, confirming to IS 5039- with IP-54 protection, made out of 3.15 mm thick CRCA sheet, 415 Volt, 3 phase , 50 Hz supply mounted on and including MS angle section 50 x 50 x 5 mm frame with front and back openable, with provision of locking arrangement dust & vermin proof , gasket, TPN busbar of size 400 amps for phase, 200 amps for neutral, insulated with colour coated heat shrinkable sleeves, mounted on proper insulator, provision for 08 Nos LT connection, with gland, welding hinges, dust & vermine proof, overall powder coated, including taking down old busbar chamber, complete all as specified and directed.
Note :- Quoted rates shall be deemed to include for grouting / fixing of feeder pillar board over & including brick masonary plateform of hight 450 mm GL, with old size brick set in CM 1:4, with PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) in foundation, 15 mm redering in CM 1:6 on exposed surfaces, 100 mm thick PCC 1:3:6 type C1 (using 20mm graded crushed stone aggregate) as in padding on top and grouting legs of panel.
Supply and installation, testing, commissioning, factory made, bus bar chamber of size 900 mm x 750 mm x 600 mm size, CPRI approved, outdoor type, confirming to IS 5039- with IP-54 protection, made out of 3.15 mm thick CRCA sheet, 415 Volt, 3 phase , 50 Hz supply mounted on and including MS angle section 50 x 50 x 5 mm frame with front and back openable, with provision of locking arrangement dust & vermin proof , gasket, TPN busbar of size 200 amps for phase, 100 amps for neutral, insulated with colour coated heat shrinkable sleeves, mounted on proper insulator, provision for 08 Nos LT connection, with gland, welding hinges, dust & vermine proof, overall powder coated, including taking down old busbar chamber, complete all as specified and directed.
Note :- Quoted rates shall be deemed to include for grouting / fixing of feeder pillar board over & including brick masonary plateform of hight 450 mm GL, with old size brick set in CM 1:4, with PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) in foundation, 15 mm redering in CM 1:6 on exposed surfaces, 100 mm thick PCC 1:3:6 type C1 (using 20mm graded crushed stone aggregate) as in padding on top and grouting legs of panel.
Deduction to be made from BOQ for Schedule 'A' Part-II (Credit Schedule from dismentling/taking down items) worth Rs 1,27,290.00 during AOC. Note :- Tenderers shall not quote for this Schedule.
M/S GHULAM MOHAMMAD AND CO.
M/S NEW FAROOQ TRADERS
M/S A.R TANTRAY
M/S RATHER CONSTRUCTION CO
M/S LATIF AHMED MIR
M/s GHULAM NABI HAJAM
M/s Alam-i-Afroz
M/S LUCKY BUILDERS
CHINAR CONSTRUCTION TRADERS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .