| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.0 LAccepted-AOC | L1 | Accepted-AOC lowest bidder | |
| 2 | L2₹12.9 L+₹1.1 L (8.96%)Rejected-Finance 300 PREM BASTI 10 SANGRUR SANGRUR PUNJAB 148001 | SANGRUR | PUNJAB | 148001 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹14.5 L+₹2.7 L (22.7%)Rejected-Finance | L3 | Rejected-Finance Being L3 |
Tender Value
Refer Docs
EMD Value
₹36,000
Closing Date
21 Mar 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SHRI ANKUR LOHIYA, IDSE
MILITARY ENGINEER SERVICES GARRISON ENGINEER SOUTH TARAPORE ENCLAVE PATIALA CANTT
As per tender documents
2023_MES_633513_2
GE(S)/PAT/T-65/N/2023-24
Open Tender
Civil Works
Item Rate
120 days
MIL STN NABHA
Refer tender documents
8 documents required · 8 mandatory
₹500
Yes
GE (SOUTH) PATIALA
₹36,000
Yes
30 Mar 2024
28 Feb 2024
23 Mar 2024
28 Feb 2024
21 Mar 2024
7 Mar 2024
28 Feb 2024 - 6 Mar 2024
Amount
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth and getting out in any type of soil complete all as apecified and directed by Engineer-in-Charge
M&L for sand cushioning to under ground cables with a layer of sand 8 cm before laying the cable and 15 cm after laying the cable complete all as apecified and directed by Engineer-in-Charge
Supply and laying well burnt sub class ‘B’ bricks. ( designated 75) locally available best quality laid dry in trenches for protection of underground cable all as specified and directed.
Returning filling in including ,spreading,levelling,watering and well ramming in layers not exc 25cm thick each complete all as apecified and directed by Engineer-in-Charge
Removing excavated material to a distance not exc 50m and depositing where directed at a level not exc 1.5 m above the starting point complete all as apecified and directed by Engineer-in-Charge
M&L for painting of sign board (size 1x1 mtr to 1.5x1.5 mtr) at sub stations by cleaning of surface by emery paper, applying single coat of redoxide as primer and double coat of synthetic enamel paint and marking of nomeclature of the installation with suitable size letter writting in capital letters. Note:- Size of letter, colour of paint will be decided by Engr-in-Charge.
M&L painting of Rolling Shutter, Iron Gates, LT Panels and AFPC Panels etc. by prepareing & cleaning of surface by removing girth, applying single coat of redoxide as primer and double coat of paint by spay painting complete all as directed by Engr-in-Charge.
M&L for Numbering of Poles (Steel & RCC poles) by painting of surface in circular Shape in Yellow Colour and numbering in black colour all as directed by Engr-in-Charge.
M&L Painting of Steel tubular LT Poles (approx 7 mtr height) by cleaning of surface by emery paper, applying single coat of redoxide as primer and double coat of aluminium paint all as directed by Engr-in-Charge.
M&L for painting the Poles (Steel & RCC poles) above coping level in five alternate layers of black and yellow colour of width 15 cm each complete all as specified and directed by Engr-in-Charge.
Dismantling of old unsv LT PCC Pole any type from root incl PCC & masonary work completely from ground all as directed by Engr-in-Charge. Note :- Removal vol will be deposited at site as directed by Engr-in-Charge.
S&F in replacement of Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9 metres long) incl marking with yellow & black paint of 1 feet width alternate around the pole, complete all as specified and directed.
S&F Prestressed concrete pole, 9.0 metres long, 102mm x 152mm at top and 102mm x 289mm at bottom, class 10 incl erection of LT OH ACSR conductor and marking with yellow & black paint of 1 feet width alternately around the pole, complete all as specified and directed.
Dismantling of Cross arms, bracing, supports, clamps and back plates etc from LT poles all as directed by Engr-in-Charge.
S&F Cross arms, bracings, supports,clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paintall as directed by Engr-in-Charge.
Dismantling of insulators any type, any size from LT Pole all as directed.
S&F Pin type, porcelain, vitreous, brown insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia for 1100 volts grade complete all as specified and as directed .
M&L for Dismantling stay assembly complete incl demolition of concrete, etc. and excavation. S&F Stay assembly with stay rod of size 20 mm complete with accessories as shown in electrical plate No. 1 (loop type insulator, stay clamps, plates incl cost of excavation and concrete cement & masonary work all as directed.
M&L for dismantling unsv Stay strand, Supply &Fix Galvanised stay strand, 7/4 mm with accessories all as specified and directed by Engr-in-Charge.
S&F in replacement of PVC insulated jumpers of suitable size PVC cable suitable for LT OH Conductor line 1100 volts of suitable size & length all as directed by Engr-in-Charge.
Anti-climbing device; spikes type fabricated out of M.S. bars (round, square and flat) ncluding nuts,bolts, washers and welding in two halves made to shape to suit the cross section of the pole all as directed.
S&F in replacement of Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size all as specified and directed.
S&F No Admission Board notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures in signal red colour and fixed with M.S. clamps, bolts and nuts of suitable size of 30x20 cm size all as specified and directed.
S&F in replacement of Cradles, hexagonal/rectangular, fabricated with galvanised steel wire 4mm dia to safeguard from OH LT lines 1100 volt grade all as directed.
S&F in replacement of Shackle Type, Porcelain, vitreous, Brown insulator of 1100 volts garde, height 100 mm and dia 115 mm including galvanised mild steel straps, washers, insulator bolts, washers and nuts all as specified and directed.
M&L for Servicing and Calibration of LT ACB circuit breaker installed in LT panel 440 volts of rating 630/800 Amp grade by cleaning of Panel & ACB by air blower, cleaning of deposited carbon and applying petrolium jelly, setting of tripping time and short circuit relay, earth fault fault relay etc by engaging of experienced technician complete all as directed by Engr-in-Charge.
M&L for Earthing complete with galvanized steel earth plate electrode 600x600x6mm tthick buried directly in ground(earth plate not less than 3.25 mtr deep below the normal ground level ) with top edge of plate not less than 2.5 mtr below the normal ground level connected to galvanized earth wire 4 sqmm by means of nuts bolts,washers,check nuts of iron or steel including test point PCC pits and RCC/CI cover in PCC 1:2:4 (type B-1) medium grade GI watering pipe 20mm dia with funnel and wire mesh and 40 mm bore GI pipe light grade proection pipe up to test point etc including excavation and charcoalt ,common salt surrounded with 15cm all around the plate all as specified and shown in EP-3 of SSR Part-I
S&F Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4 mm dia galvanised iron or steel wire all as complete.
M&L for Earthing complete with galvanized steel earth plate electrode 600x600x6mm tthick buried directly in ground(earth plate not less than 3.25 mtr deep below the normal ground level ) with top edge of plate not less than 2.5 mtr below the normal ground level connected to galvanized earth strip 32x6 mm thick by means of nuts bolts,washers,check nuts of iron or steel including test point PCC pits and RCC cover in PCC 1:2:4 (type B-1) medium grade GI watering pipe 20mm dia with funnel and wire mesh and 40 mm bore GI pipe light grade proection pipe up to test point etc including excavation and charcoalt ,common salt surrounded with 15cm all around the plate all as specified and shown in EP-3 of SSR Part-I
S&F Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32x6 mm size GI Strip all as complete.
S&F in replacement of LT lightning arresters for outdoor use, non-liner resistor type, horn gap and choking coil, maximum working pressure 1100 volts all as specified & directed by Engr-in-Charge.
Taking out unsv LT Cable & Supply, laying, Jointing connecting LT UG cable XLPE insulated,PVC bedded galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 240 sqmm 3.5 core laid in trenches/on poles/walls/in ducts/passing through pipes and including necessary cable lugs, bolts, nuts and washers complete all as specified and directed.
All as per serial item above but for 185 Sqmm 3.5 Core.
All as per serial item above but for 150 Sqmm 3.5 Core.
All as per serial item above but for 120 Sqmm 3.5 Core.
All as per serial item above but for 95 Sqmm 3.5 Core.
All as per serial item above but for 70 Sqmm 3.5 Core.
All as per serial item above but for 50 Sqmm 3.5 Core.
All as per serial item above but for 35 Sqmm 3.5 Core.
All as per serial item 35 above but for 25 Sqmm 4 Core.
All as per serial item 35 above but for 16 Sqmm 4 Core.
All as per serial item 35 above but for 16 Sqmm 2 Core.
All as per serial item above but for 6 Sqmm 2 Core.
S&F in replacement of Aluminum thimbles suitable for 150 to 240 Sqmm 3.5 Core LT Cable by dismantling of LT cable from transformer/MCCB/Bus bar etc and cutting cable core ends and making fresh for fixing of new thimbles by using crimping tool, applying LT insulation tap & testing all as specified and directed by Engr-in-Charge. Note : (Thimles for RYB & N will be count as one set)
All as per serial item above but for 70 to 120 Sqmm.
All as per serial item above but for 25 to 50 Sqmm.
S&F Cable jointing kit for 1.1 KV (Earthed) grade cable for outdoor/indoor end termination heat shrink type joint complete with jointing material and accessories suitable for 2/3.5/4 Core XLPE armoured /PVC aluminium conductor cable of size16 to 35 Sqmm all as specified and directed.
All as per serial item above but for cable of size 50- Sqmm to 95 Sqmm.
All as per serial item above but for cable of size 120 Sqmm to 185 Sqmm.
All as per serial item above but for cable of size 240 Sqmm
S&F Cable jointing kit for 1.1 KV (Earthed) grade cable for outdoor straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 Core XLPE armoured /PVC aluminium conductor cable of size 70-185 Sqmm all as specified and directed.
S&F in replacement of MCCB 3 Pole, 415 V, fixed type, 100 Amps with breaking capacity 16 KA all as specified and directed by Engr-in-Charge.
All as per item above but for MCCB 3 Pole, 125 Amps, 25 KA.
S&F in replacement of MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA all as specified and directed by Engr-in-Charge.
All as per item above but for MCCB 4 Pole, 200 Amps, 36 KA.
All as per item above but for MCCB 4 Pole, 250 Amps, 36 KA.
All as per item above but for MCCB 4 Pole, 315 Amps, 36 KA.
S&F in replacement of digital Ameter of span rating 600 Amps Suitable for LT Panel as per existing size complete all as directed by Engr-in-Charge.
S&F in replacement of digital Voltmeter of span rating 500 Volts Suitable for LT Panel as per existing size complete all as directed by Engr-in-Charge.
S&F in replacement of Multifunctional meter Suitable for LT Panel 440 Volts as per existing size complete all as directed by Engr-in-Charge.
S & F in replacement of RYB Indicator for LT Panel/APFC Panel all as directed.
S&F in replacement of 415V 10KA 'C' Curve MCB TP 25 to 63 Amps rating, 10 KA in the DB/LT Panel/APFC Panel complete with connection testing and commissioning all as specified and directed by Engr-in-Charge.
S&F in replacement of Power Capacitor bank 7.5kVAr rating suitable for 433 volt grade all as directed.
All as per serial item above but for 10 kVAr rating.
All as per serial item above but for 12.5 kVAr rating.
All as per serial item above but for 15 kVAr rating.
All as per serial item above but for 25 kVAr rating.
M&L for treaming of tree/ tree branches spreaded over/touching the LT OH ACSR conductors/LT Poles/ LT Panels etc by taking proper shut down from MES all as directed by Engr-in-Charge. Note:- Contractor will provide all tools, ladder and safety equipments required for treaming of tree /tree branches.
S&F in replacement of Ameter of span rating 300 Amps Suitable for APFC Panel as per existing size complete all as directed by Engr-in-Charge.
S&F in replacement of Voltmeter of span rating 500 Volts Suitable for APFC Panel as per existing size complete all as directed by Engr-in-Charge.
Dismantling of OH ACSR conductor from LT Poles and jointing/tightening of the broken/loose conductors and refixing the same on the LT Poles as in position as existing incl cost of jointing material, cleaning of pin insulators all as directed by Engr-in-Charge.
M&L for Dismantling of ACSR conductors and, S&F Auminium conductor steel reinforced as per IS-398 (Part-2) of of 1996 suitable for 1100 volts OH line all as specified and directed.
S&F in replacement of CT Coil ratio of rating 200/5, 50 Hz, Line voltage 440V, as per ISS-2705-1992 suitable for Existing LT Panel incl taking out unsv CT any type all as specified and directed. (for RYB will be count as 01 set) .
S&F in replacement of CT Coil ratio of rating 400/5, 50 Hz, Line voltage 660V, as per ISS-2705-1992 suitable for Existing LT Panel incl taking out unsv CT any type all as specified and directed.
S&F PVC spacer 4/5 way suitable for LT OH conductor 1100 Volts grade.
Supply and fixing post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete including PCC/masonary work to fix lanterns on post top all as specified and directed.
Supplying, fixing, connecting and Testing in replacement, LED Bollard Light 10 Watt Warm White , 240 Volts, 50 Hz having height 2 Feet suitable for Garden/Pathway, IP-65 grade, new generation, energy saving, environmental friendly, long life, aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source duly connected with control switch with and including cost of masonary work for fixing/mounting by making sqaure PCC platform in the garden complete all as specified and directed. Model No. HLOB-02-10-WW of Make : Halonix or equivalent as mentioned hereinafter.
(m) Platform for the feeder pillar board with PCC 1:2:4 15 Cm thick in foundation, Brick (Sub Class B) /Stone/ PCC block work in CM 1:6 ,rendering 1:6 on exposed surfaces and 100 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grouting blots etc for panel . The platform shall be of 60 Cm height above ground level and of adequate size leaving minimum 30 Cm all around the feeder pillar box for movements. Note :- (i) Incoming and outgoing cable shall be fixed with appropriate size of copper thimble. (ii) Apron shall be provided at bottom for protection of cable to avoid entry of vermins, reptiles. (iii) Entries of all sizes of cables in panel should be done through adequate size of metallic cable glands.
(m) Platform for the feeder pillar board with PCC 1:2:4 15 Cm thick in foundation, Brick (Sub Class B) /Stone/ PCC block work in CM 1:6 ,rendering 1:6 on exposed surfaces and 100 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grouting blots etc for panel . The platform shall be of 60 Cm height above ground level and of adequate size leaving minimum 30 Cm all around the feeder pillar box for movements. Note :- (i) Incoming and outgoing cable shall be fixed with appropriate size of copper thimble. (ii) Apron shall be provided at bottom for protection of cable to avoid entry of vermins, reptiles. (iii) Entries of all sizes of cables in panel should be done through adequate size of metallic cable glands.
M&L Cutting of road /PCC path upto the depth of pipe & making good the disturbed surface with PCC 1:2:4 (20 mm aggregate) using extra cement including earth work complete all as specified and directed.
M&L for GI tubing light grade 40 mm bore for passing through cables under the floor ,along the wall or along the pole complete all as specified and directed.
All as per serial item above but for 80 mm bore.
M&L PCC 1:2:4 ype B2 ( using 20/40 mm graded stone aggregate) as in coping/ foundation / filling and mass concrete (new & existing poles) complete all as specified.
M&L PCC 1:4:8 type D2 ( using 40 mm graded stone aggregate) as in foundation of poles and stay etc complete all as specified.
Disconnecting servo controller voltage stabilizer 200 KVA, lifting by hired hydra crane form site, to and fro transportation to workshop for repair and lfiting again after repair to kept at site with hydra crane.
Taking down unsv variable/buck boost transformer, cutting copper windings, M&L for winding of stabilizers with suitable gauge copper wire including cleaning of entire body outer & inner of stabilizer. Note: test report of insulation of winding will submitted by the contractor, testing of stabilizer for smooth functioning. All as directed by Engr-in-Charge.
M&L for filling of insulation oil upto recommended level incl welding work to arrest oil leakage all as specified and directed by engr-in-charge.
Supply only servo motor suitable for 200 KVA servo stabilzer.
Supply only contactor relay suitable for 200 KVA servo stabilzer.
AGGARWAL & CO
Gurcharan Singh Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .