Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.7 LAccepted-AOC 368 MAHESHPUR SECTOR 21 PANCHKULA HR 134112 | PANCHKULA | PANCHKULA | HARYANA | 134112 | L1 | Accepted-AOC L1 | |
| 2 | L2₹29.0 L+₹25,349 (0.88%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹31.5 L+₹2.7 L (9.50%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹33.9 L+₹5.2 L (18.0%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹37.9 L+₹9.2 L (32.0%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
5 Dec 2019, 6:00 pmClosed
Shri Vineet Modi
CWE AF North Bangalore Bellary Road JC Nagar Post Bangalore 560006
PROVISION OF FIRE SENSOR AND ALARM SYSTEM FOR STORAGE SHEDS AT 26 ED AF, MARATHAHALLI
2019_MES_290681_1
87546CWEAFNMAR
Open Tender
Miscellaneous Works
Item Rate
180 days
GE AF MARATHAHALLI
AS PER NIT
5 documents required · 5 mandatory
₹500
GE AF MARATHAHALLI
₹86,000
Yes
27 Jan 2020
18 Oct 2019
6 Dec 2019
18 Oct 2019
5 Dec 2019
24 Nov 2019
19 Oct 2019 - 1 Nov 2019
Amount
Supply, Installation,commessoning and Testing of 2 loop addressable surface mounting FACP certified to EN54-2/EN54-4norms with 8x40 character LCD capable of 127 devices per loop. The FACP shall be certified as meeting the requirements of EN54-2 and EN54-4 by a suitable, notified body. In order to facilitate re-configuration and system extension, the allocation of addresses to devices shall be independent of their physical arrangement on the loops.The FACP shall have an event log capable of storing the last 500 events that have occurred. Up to 127 individually addressed standard devices shall be configured on each addressable loop. Loop powered sounders incorporated as a sensor bases shall be available. The FACP shall have the capability to support sub-addressing of addressable modules. The FACP shall monitor all critical system components and interconnections, internal and external, such that a failure, which would prevent the correct operation of the alarm functions, causes the FAULT indicator to light and a message to be given on the alphanumeric display within 60 seconds of occurrence.The FACP shall support minimum Four access levels,flash EPROM, 4 Nos. of programmable relay controls. The FACP Shall be housed in Ms Powder coated Cabinet, complete with exclusive Notification Circuits, and with Fire, Fault & Auxiliary Relays.The Panel shall support to programmed as a node on a peer to peer network with other Panels. Make : Ceasefire/ Securezone/ LST
Supply installation , commissoning and testing of Analogue Addressable photo Electric smoke sensor with Short circuit isolator base having removable high performance chamber with Twin fire LED's allow 360 degree veiwing, lock mechanism ( sensor to base),can adjust sensitivity range between 1% to 4.5% obs/mtr at any level ,Electronically addressed, approved by LPCB. Flat Response technique which nullifies the need for having ionisation detectors. Devices include High Performance optical chamber for effective and accurate analysis of causes of fire. FAST addressing technique Flexible (programmed in any sequence), Automatic (stored in EEPROM), Secure (cannot be changed easily) and Time saving. Make : Ceasefire/ Securezone/ LST
Supply, Installation,commessoning and Testing of Analogue Addressable Manual Call Point having status LED for Alarming & standby mode,inbuild short circuit isolator,Electronically addressed approved by LPCB as EN54-11: 2001 . Rapid response using operation of a call point to the system indicating fire condition is typically less than 1.5 seconds FAST addressing technique Flexible (programmed in any sequence), Automatic (stored in EEPROM), Secure (cannot be changed easily) and Time saving. Make : Ceasefire/ Securezone/ LST
Supply, Installation,commissoning and Testing of An Addressable Loop-Powered Wall Sounder Beacon as per the CHQ-WS but additionally featuring an integral beacon within the horn which utilises high intensity LED technology. Special bases available: YBO-R/3(RED), YBO-R/ SCI(RED), YBO-R/3(WHT) and YBO-R/SCI(WHTSNDR). Make : Ceasefire/ Securezone/ LST
Supply, Installation,commissoning and Testing of Isolator Base fully monitored for short/Open circuit compatible with ESP Analogue Addressable Protocol,Electronically addressed, approved by LPCB,unit incorporated an amber LED to show when it is isolating a section of a Loop Make : Ceasefire/ Securezone/ LST
Supply, laying and testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 2.5 sqmm, 2 core,1100 Volts grade complete drawn through PVC conduit suitable size with all acessories on wall/trusses all as specified and directed
Supply, laying and testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 2.5 sqmm, 2 core,1100 Volts grade complete all as specified and directed
Boring of holes under road, payment, hard standing by trenchless using ultra soundind technique and necessary machine including HDPE pipe of 40 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed .
Excavation in trenches in soft /loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep for laying of cables etc, getting out and forming bottom surface to required gradient complete all as specified and directed.
Returning filling including spreading levelling watering and well ramming to excavated soil in layers not exc 25 cm thick complete all as specified and as directed
Removing excavated material not exc 50m and depositing where directed at a level not exc 1.5m above the starting point in soils complete all as specified and as directed.
Material and labour for Sand cushioning to cables with a layer of sand before and after laying the cable complete all as specified and as directed. Note :- Sand shall be measured after punned down.
Material and labour for Brick protection cover on cable with sub class 'B' bricks, across in trenches laid dry and flat adjacent to each other complete all as specified and as directed
Material and labour for Cutting PCC / road 150mm thick for laying of LT UG cable and making good the disturbed surfaces with cement concrete 1:2:4, type B-1, using 20mm graded stone aggregate complete all as specified and directed.
Continental Engineers and contractors
Cross Fire System
SREE VARU ELECTRICALS
Satya Dharam Vikas Fire Safety & Security Services
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .