Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.3 CrAccepted-AOC | ₹16.3 Cr Quoted ₹16.5 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹19.2 CrRejected-Finance 301 CHAMUNDA ENCLAVE PLOT NO 89 AIROLI SECTOR 8A NAVI MUMBAI 400708 | THANE | MAHARASHTRA | 400708 | ₹19.2 Cr | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹20.6 CrRejected-Finance | ₹20.6 Cr | L3 | Rejected-Finance Other than L1 |
| 4 | L4₹24.5 CrRejected-Finance K 99 LGF KALKAJI NEW DELHI 110 019 | NEW DELHI | SOUTH EAST DELHI | DELHI | 110019 | ₹24.5 Cr | L4 | Rejected-Finance Other than L1 |
| 5 | Rejected-Technical FL 404 4TH FLOOR MONT BLANC CHS LTD PLOT NO 138 SEC 13 KHARGHAR DIST RAIGAD NAVI MUMBAI 410 210 | RAIGAD | MAHARASHTRA | 410210 | - | - | Rejected-Technical Does not qualify for opening of Cover-2 being two classes below the eligible class as per NIT. |
Tender Value
₹17.7 Cr
EMD Value
₹12.1 L
Closing Date
2 Jan 2023, 6:00 pmClosed
Chief Engineer Pune Zone
Chief Engineer Pune Zone Dakshin Kaman Marg CAMP, Pune PIN- 411001
ADDN/ALTN TO OFFICERS, JCOS AND ORS MD ACCN AT COLABA MUMBAI
2022_MES_559566_1
CA NO CEPZ/MUM/TOKEN-33 OF 2021-22
Open Tender
Civil Works
900 days
Colaba Mumbai
Class SS
Category a(i)
Also Refer NIT
8 documents required · 8 mandatory
₹3,000
GE (West) Colaba, Mumbai
₹12.1 L
Yes
6 Feb 2023
22 Oct 2022
4 Jan 2023
22 Oct 2022
2 Jan 2023
19 Dec 2022
24 Oct 2022 - 9 Nov 2022
Amount
M&L for minor cleaning work, removal of loose concrete and filling cracks with polymer modified mortar using SmartCare RP or Epoxy Mortar and supplying and applying High performance hybrid polyurea elastomeric waterproofing coating cold applied of spray / brush applied, SmartCare Ultron liquid membrane with an elongation of 600% and tensile strength of 12.6 N/mm2 as per ASTM D 2370, crack bridging ability of 3mm as per ASTM C1305, shore A Hardness of min. 75 as per ASTM D 2240. The system includes final base preparation, epoxy primer application and applying SmartCare Ultron or approved equivalent in two coats at 1.5 kg per Sqm etc, complete as per Manufacturer specifications. Supplying and applying High performance hybrid polyurea elastomeric waterproofing coating cold applied of spray / brush applied, SmartCare Ultron liquid membrane with an elongation of 600% and tensile strength of 12.6 N/mm2 as per ASTM D 2370, crack bridging ability of 3mm as per ASTM C1305, shore A Hardness of min. 75 as per ASTM D 2240. The system includes final base preparation, epoxy primer application and applying SmartCare Ultron or approved equivalent in two coats at 1.5 kg per Sqm etc, complete as per Manufacturer specifications over and including 30mm thick PCC (1:2:4) type B-0 for padding on roof surfaces and 10mm thick readymix plaster mortar using liquid water proofing compound applying while concrete is green and all other similar works complete all as specified and directed (SmartCare Ultron Hybrid Polyurea /DR Fixit Flexi PU (270)(I) or any equivalent). NOTE: PU treatment shall be done by authorized applicator and work shall be executed in the presence of company rep.
Cordoning off the area for repairs so that unauthorized manmovement is restricted in the area under repairs upto 2.0 mtr height using GI Sheets or steel posts temporarily with all warning signs, maintaining the same till completion of work and removing the same after the completion of activity including cleaning of dust, debris removing to other side of the barricade on daily basis. Complete including all necessary fitting as per specifications /instructions of the consultation.
Supporting the structural element temporarily using heavy duty flat headed steel props of minimum capacity 3 Ton and having height of upto 16 ft erected vertically in plumb, braced horizontally at centre / diagonally with each others using 40 Nb steel pipes and supporting a continuous 4” x 3” wooden runner just below the structural element, resting on wooden block to support the structure provisionally during repair and jacketing etc. and maintaining them in position till required as directed by Engr-in-charge.
Providing and erecting triple layered safety net of 75 mm. x 75 mm. x 12 size,made out of nylon/ Polypropylene/polyethylene rope as per IS 5175:1992 mesh cord position protective layer of 6 mm thk. HDPE cellular foam sheet to catch personal and debris and keeping the same during the period of work and including dismantling and taking away after completion of the work and use for maximum opening at 1st floor level or one level below working floor area including supporting the same with 40 nb MS pipes as and where required to prevent the debris falling on ground and periodically cleaning of the fallen debris from net during progress of work and maintaining the same during the entire period of work.
Providing and erecting at site self supported two legged B class tubular steel scaffolding to reach any place of work on external face as well as internal areas so as to reach elements of building, including proper leveling using base jacks, minimum 1 mtr wide working platform at every 2 mtr level, approaches, extension, stepped MS ladders, so as to reach all levels upto height of 45 mtr or as per site requirement, lifting tackle for men and materials, supporting stubs for scaffolding including anchoring on walls and restoring the same after removal, anchoring, etc. all complete, dismantling and taking away all materials after completion of proposed work etc. all complete. (Measurement : Lavational area of scaffold erected for every two legs).
Carefully chipping , removing existing internal plaster upto 12 to 15 mm thick by low impact high frequency hammer/chipper without damaging the original sound brickwork or concrete including removal of POP/ Gypsum plaster if any on walls any thickness, racking of joints, daily cleaning and stacking of debris at prescribed location in polypropylene/ paper bags, disposing off the debris so generated on weekly basis out side the premises, etc. complete as directed by Engineer-in-charge.
Carefully chipping , removing existing external plaster upto 25 mm thick by low impact high frequency hammer/chipper without damaging the original sound brickwork or concrete including racking of joints, daily cleaning and stacking of debris removing as per complete as directed by Engineer-in - charge. Note : Height of Bldg above Up to fourth floor
Carefully chipping , removing existing external plaster upto 25 mm thick by low impact high frequency hammer/chipper without damaging the original sound brickwork or concrete including racking of joints, daily cleaning and stacking of debris removing as per complete as directed by Engineer-in - charge. Note : Height of Bldg above Five to Eight floor
Providing and applying average 25mm thick plaster in two coats with readymix prepacked proportioned dry mix mortar, blended with PP fibers, mixed with liquid water proofing compound on other than fair faces of brick wall or concrete surfaces additives, on external surfaces including transporting of material, mixing, curing, etc.complete as per direction of Engr-in-charge. Note :- (i) Liquid water proofing compound will be measured and paid seperately as supply only (ii) Height of Bldg up to fourth floor. MAKE: M/s ACC Accoplast/ M/s Ultratech Readiplast/ M/s Magicrete Magicplast/ CK Birla's AEROCEN
Providing and applying average 25mm thick plaster in two coats with readymix prepacked proportioned dry mix mortar, blended with PP fibers, mixed with liquid water proofing compound on other than fair faces of brick wall or concrete surfaces additives, on external surfaces including transporting of material, mixing, curing, etc.complete as per direction of Engr-in-charge. Note :- (i) Liquid water proofing compound will be measured and paid seperately as supply only (ii) Height of Bldg Five to eight floor. MAKE: M/s ACC Accoplast/ M/s Ultratech Readiplast/ M/s Magicrete Magicplast/ CK Birla's AEROCEN
Supply only liquid water proofing compound. MAKE: DrFixit LW+/ Sika/ Fosroc
Providing and applying average 12-15 mm thick plaster in two coats for with readymix prepacked proportioned dry mix mortar, blended with PP fibers, waterproofing additives, on external surfaces including transporting of material, mixing, curing, etc.complete. MAKE: M/s ACC Accoplast/ M/s Ultratech Readiplast/ M/s Magicrete Magicplast/ CK Birla's AEROCEN
Providing & applying anti algal water-based Elastomeric exterior wall finish on old as well as newly plastered surfaces including surface preparation, applying suitable wall Prime seal primer 8-10 Sqm per ltr coverage area and application of two coats (base coat 4.2 -4.7 & top coat 6-6.5 sqm per ltr coverage area ) & of paint by roller etc. complete. (Make- Dr Fixit Rain coat classic, Asian paints, Berger ) Note : Height of Bldg Up to fourth floor.
Providing & applying anti algal water-based Elastomeric exterior wall finish on old as well as newly plastered surfaces including surface preparation, applying suitable wall Prime seal primer 8-10 Sqm per ltr coverage area and application of two coats (base coat 4.2 -4.7 & top coat 6-6.5 sqm per ltr coverage area ) & of paint by roller etc. complete. (Make- Dr Fixit Rain coat classic, Asian paints, Berger ) Note : Height of Bldg five to Eight floor.
M&L for preparation of newly plastered brick/concrete applying two coats of oil bound distemper over a coat of alkali resistant priming paint complete all as specified.
Examining concrete by tapping with light hammer and marking of the loose concrete areas of structural elements in straight line geometrical forms, grooving the edges same with grinder up to 5 - 10 mm depth without damaging existing rebars, carefully removing carbonated concrete around the rebars up to 10 mm depth by low impact high frequency hammer/chipper without damaging the sound concrete, in detailed methodology, daily cleaning and stacking of debris at prescribed location complete as directed by Engineer-in - charge.
Drilling Holes of 12mm dia, upto 100mm deep holes in structural members at the intervals of 300 to 500mm in staggered manner or along the crack as directed by the Engr-in-charge in RC structural element including Cleaning of the holes by air blower and Inserting 12mm dia. Teflon nozzles compatible with epoxy injector and having machined external end to receive outlet of grouting gun. Fix it inside the holes by applying thixotropic epoxy putty to ensure complete sealing and allow to cure the system for min.8 hrs before grouting including removing nozzle projections, excess putty if any over concrete element grinding, levelling and finishing the external surface, after completion of the work, etc complete. Note : Epoxy putty will be paid seperately. Drilling of hole shall be done by authorized applicator and the work shall be executed in the presence of company rep.
Grouting Injecting low viscosity high molecular weight thermosett polymer Monopol 250 H by pressure and using pressure epoxy injector with accessories till nozzles refused to accept the grout, Including Mixing material components part a and part b in required quantities as per mfg instruction by weigh batching Filling the grouting gun with monopol 250 H and maintaining desired pressure in the gun, air compressor and at exit (minimum 3 to 4 kg/Cm2) by a mechanism to monitor both pressure gauges and controlling the same by release valves and release the grout as per requirement simultaneously to grout the structural element through prefixed nozzles till its refusal. Seal the nozzle with thixotropic epoxy putty after the refusal. Note : leakages through other nozzles or cracks are required to be monitored while grouting and such points to be sealed as and when required without any extra cost. MAKE: Dr Fixit Epoxy injection Grout/ Sika injection-201 N/ Fosroc conbextra EP 10
Clean existing reinforcement with wire brush/ rotary wire brush to make surface free from rust scales, loose material, dirt etc. complete and providing, applying two coats of alkaline rust converting primer confirming to ASTMB- 117, on the existing rebars and allowing it to react with rust for 6 hrs and form a corrosion resistant, insoluble and adherent protective layer , including cleaning the reinforcement,wirebrushing to remove loose rust spalls, with time interval of 1hour between the coats. Name of Manufacturer: BASF/Fosroc/Sika/ Dr Fixit
Providing and application full and unbroken coating of anticorrosive protective zinc rich epoxy coating on expose reinforcement in two coats with time interval of minimum 1 hours between each coat including mixing of both componants by weight as per mfg specifications, brush application, curing to form a anticorrosive protective coating with high mechanical strength to cementitious repair works, etc complete. Name of Manufacturer: BASF/Fosroc/Sika/ Dr Fixit
Providing and application of hitech concrete penetrating, water based, organic, Bi-polar, calcium nitrite free, migratory corrosion inhibitor on concrete surface having Ph 9.5 which migrates to a virtual extent of 100 mm inside concrete through pores, to inhibit the corrosion process on embedded steel at both anodic and cathodic ends by depassivating the Electro-chemical reaction in that region thereby protecting rebar on all sides. Name of Manufacturer: BASF/Fosroc/Sika/ Dr Fixit
Providing and fixing additional corrosion resistant hot dip galvanised steel rebar Fe415 or higher grade as per required dia in various structural elements like column, beams and Slab etc to replace the lost rebars section due to corrosion including cutting, bending and fixing the bar, tieing with preleft bars by GI binding wire, retouching local damages in coating if any of with Zinc spray, etc. complete. Name of Manufacturer: BASF/Fosroc/Sika/ Dr Fixit
Rebuilding the section of damaged RCC elements to its original size or as per consultants recommandations in thicknesses of 40-100 mm by providing and casting with microconcrete of grade M-40 and above including providing and fixing of watertight foam faced finish shuttering of minimun 18 mm th. with supporting framework,all lead lift, mixing, placing, deshuttering, levelling the surface by grinding off cementitious slurry or construction joint differences if any to satisfaction of engg. incharge, curing etc. complete.(Rate including- cube test to be conducted for every 5 M.T. workdone.6 no's of sample required per test). Ensure the quality of water by testing water as per IS 456 and document the same. Ensure temperature at time of mixing should be between 25 to 40 degree celcius by electronic temperature gauge Name of Manufacturer: BASF/Fosroc/Sika/ Dr Fixit
Rebuilding the section of damaged RCC elements to its original size or as per consultants recommandations in thicknesses up to 40 mm in layers of 20 mm each by providing and applying with hand, single component shrinkage compensated thixotropic mortar of grade M40 and above, including all lead lift, mixing by addition of water only as per manufacture's recommendation, levelling the surface, curing etc. complete.(Rate including- cube test to be conducted for every 5 M.T. workdone.6 no's of sample required per test) Ensure the quality of water by testing water as per IS 456 and document the same. Ensure temperature at time of mixing should be between 25 to 40 degree celcius by electronic temperature gauge Name of Manufacturer: BASF/Fosroc/Sika/ Dr Fixit
M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips and including welding has to be done with minimum 20 cm over lap for new and old of any height.
M & L for mild steel TMT bars any dia in stirrups, spaces and binders, cut to length, bent to shape required, incl cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed.
Mixing and applying SBR latex modified cementitious bond coat using cement 2.2 kg per square metre on prepared concrete surfaces of parent material complete all as specified and as directed (Note: SBR latex shall be paid for separately).
Supply only approved SBR latex from FOSROC/BASF/DR FIXIT/ SIKA for bonding coat (Note: Rate shall be in terms of solid contents of polymer).
Mixing and applying SBR latex modified cement mortar 25 mm thick in cement sand mortar in proportions of 1:3 (1 cement and 2 graded quartz aggregate) with polymer admixed in proportions as approved, including trowelling with wooden tools on prepared concrete surfaces of parent material complete all as specified and as directed (Note: Acrylic polymer shall be paid for separately).
M & L for RCC M-30 (Design Mix) grade work as in columns, beams, slabs, chajja, railing in complete all as specified and as directed.
Providing and fixing special water tight centering and shuttering including bolting, strutting, propping etc. so as to withstand a pressure of 0.1 Mpa including removal of form from all locations including beams, columns, slabs, walls, foundations, footings, landings, stairs, balconies etc. complete all as specified and as directed.
Dismantling of floor hearth or wall tiling including cement mortar bedding but not backing and rubbish off the primises complete all as directed.
M&L for non skid ceramic digital coloured ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm in floors etc. set and jointed in neat cement slurry over 15 mm thick screed bed in cement mortar 1:6 and pointed in white or coloured cement to match complete all as specified and directed.
M&L Non Skid digital coloured ceramic tiles 7 to 8 mm thick (Square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over rendering 10 mm thick on fair faces of brick work in CM (1:4) complete all as specified and directed.
Note for item Nos. 33 to 35:- Tile fixing shall be done by Tile master/ authorized applicator of the tile manufacturer. Makes of tiles shall be as specified in Appendix 'C'.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons,dados etc laid, bedded and pointed in any mortar and removal of rubbish off the site complete all as specified & directed.
M&L for diamond cut kota stone slab flooring 20-25 mm thick over cement screed bese laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing to mirror finish inluding Screed bed or bedding layer of mortar 15 mm thick in (1:6) for laying floor finishes complete all as specified and directed.
Ditto all as per Item No 37 above but in riser of steps, skirting, dado and pillar laid over cement screed and jointed over rendering 10 mm thick on fair faces of brick work in CM (1:4) complete all as specified and directed.
M&L for Jet Black granite 18-20 mm thick Machine cut, pre polished, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone as in kitchen platform, flooring including grinding mirror polishing and half moulding laid over 15 mm thick screed bedding in cement mortar 1: 6 and all other similar works complete all as specified and directed.
Taking up or down steel tubing/ UPVC tubing and connection including cleaning for refixing or removed to store,15 mm bore complete all as specified and directed.
S & F Unplasticized Polyvinyl Chloride (UPVC) tubing of size 15 mm bore, medium grade, pressure rating 10 Kgf/Sqcm , Unplasticized materials with all Fittings such as Tees, elbows, sockets, bends, unions, shortpieces, nipples, brass nuts and diminishing pieces complete all as per IS 13593-1992, fixed to wall and ceiling or laid in floors and making good disturbed surfaces to match the existing surfaces complete all as specified and as directed by Engr-in-Charge. Make- Prince/ Finolex/ Supreme
Note for item No. 41:- UPVC pipe joint shall be fixed with approved solvent by authorized applicator in the presence of company rep. Pressure testing of internal plumbing works shall be carried out before plastering.
Taking up or down steel tubing and connection including cleaning for refixing or removed to store, 20 mm dia bore complete all as specified and directed
S & F steel water tubing of size 20 mm bore, medium grade, galvanised iron with all Fittings such as Tees, elbows, sockets, bends, unions, shortpieces, nipples, brass nuts and diminishing pieces complete all as per IS 1239, fixed to wall and ceiling with 150 mm gap between wall & pipe with clamp provided every 2 mtr or laid in floors with and making good disturbed surfaces to match the existing surfaces complete all as specified and as directed by Engr-in-Charge.
Refixing old steel tubing and connection in new or old portion (walls ceiling, floors etc) for 20 mm bore complete all as specified and directed
Taking up or down steel tubing and connection including cleaning for refixing or removed to store, 25 mm dia bore complete all as specified and directed
S & F in repairs steel water tubing of size 25mm bore, medium grade, galvanised iron with all Fittings such as Tees, elbows, sockets, bends, unions, shortpieces, nipples, brass nuts and diminishing pieces complete all as per IS 1239, fixed to wall and ceiling or laid in floors and making good disturbed surfaces to match the existing surfaces complete all as specified and as directed by Engr-in-Charge.
Cutting chases, pinning in making good to facing on brick walls where required and pointing in cement mortar (1:3) to ends for concealed water tubing and making good ,cutting n, exc. 10cm girth complete all as specified and directed.
S & F in repairs vitreous china wash down, white, water closet pan (pedestal pattern) with 'P' or 'S' trap Model 'CONVENTIONAL' cat part No. S1053102 of CERA or of equivalent model in makes specified in Appx 'C' with P or S trap, including plastic seat cover model 'CAJOL' cat Part No.B1510123 of CERA or of equivalent makes specified in Appx 'C' to match with colour of WC, closed pattern with flat bottom & cover and chromium plated mild steel or aluminium anodized hinging device including connecting to trap and flushing pipe, anti-syphonage pipe etc and screwed with brass screws to sheesham wood plugs embedded in floor complete all as specified and directed by Engineer-in-Charge.
S & F wash basins, vitreous china, white, flat back, of size 550mm x 400mm x 140mm or nearest size conforming to model 'CALBURT' Cat No. S2020137 of CERA or of equivalent model in other makes as listed in Appendix 'C, with and including cast iron brackets (embedded in wall upto 110 mm depth with and including cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate or fixing on wall with and including rawl plug and screws), 32 mm nominal size, copper alloy, nickel chromium plated finish waste fittings, including painting of fittings and brackets, sealing gap between wall and table top basin with silicone sealant, cutting and making good the walls wherever required and connecting to supply pipes, waste pipes, waste fittings etc. with silicone sealant complete all as specified and directed by Engineer-in-Charge.
S & F in repairs 10 litres capacity, low level, syphonic type, white, plastic Twin flushing cistern conforming to model 'COMPASS' Cat No. B1020106 of CERA or of equivalent model in other makes as listed in Appendix 'C as per IS 7231: 1994 with inlet, ball valve, float and handle including brackets and 40 mm nominal dia high density polyethylene pipes for flush pipe complete all as specified and as directed by Engr-in-Charge.
S & F in repair 15 mm bore fancy type angular valve cast copper alloy screwed down, high pressure, with crutch or butter fly handle, screwed both ends for iron pipe or for unions complete all as specified and as directed by Engr-in-Charge . Make:- Cera Cat Part No F 1015201 or of equivalent model in other makes as listed in Appendix 'C.
S & F in repair 15 mm bore fancy type concealed stop cock (regular body) cast copper alloy screwed down, high pressure, with crutch or butter fly handle, screwed both ends for iron pipe or for unions complete all as specified and as directed by Engr-in-Charge . Make:- Cera Cat Part No F 1015361 or of equivalent model in other makes as listed in Appendix 'C.
S&F PVC connection 15mm size PTMT nuts of length 450 mm.
S & F in repair 15 mm bore fancy type bib taps long body (two in one) cast copper alloy 15mm bore with fancy chromium plated screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed by Engr-in-Charge.Make:- Cera Cat Part No F 1015163 or of equivalent model in other makes as listed in Appendix 'C.
S & F in repair 15 mm bore fancy type bib taps long body cast copper alloy 15mm bore with fancy chromium plated screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed by Engr-in-Charge. Make:- Cera Cat Part No F 1015151 or of equivalent model in other makes as listed in Appendix 'C.
S & F in repair for 15 mm bore fancy type wall mixer with 115 mm long bend pipe for connection to overhead shower(with bush and piston Divertor fittings) with aerator complete all as specified and as directed by Engr-in-Charge. Make:- Cera Cat Part No F 1015401 or of equivalent model in other makes as listed in Appendix 'C.Equivalent of JAQUAR/ESS ESS
S & F in repair 15 mm bore fancy type health faucet with SS hose complete all as specified and as directed by Engr-in-Charge .Make:- Cera Cat Part No F 8030106AB or of equivalent model in other makes as listed in Appendix 'C.
S & F in repair fancy type CP Towel Rail 61 cm long complete all as specified and as directed by Engr-in-Charge. Make:- Cera Cat Part No F 5007101 or of equivalent model in other makes as listed in Appendix 'C.
S & F in repair CP soap dish complete all as specified and as directed by Engr-in-Charge. Make:- Cera Cat Part No F 5002106 or of equivalent model in other makes as listed in Appendix 'C.
S & F in repair CP toilet paper holder all as per cat part. Make:- Cera Cat Part No F 5007109 or of equivalent model in other makes as listed in Appendix 'C.
S&F in repairs sheet glass corner shelf assembly consisting of 5.5 mm thick sheet galss shelf 12 cm wide with chromium plated bracket guard and railing 60 cm long fixed to walls using complete all as specified and as directed by Engr-in-Charge.
Supply and fixing 15 mm bore overhead shower 250 mm dia single flow (ABS body chrome plated with grey face plate) with rubit cleaning system including shower arm 240 mm long(light weight) round shape with wall flange complete all as specified and as directed by Engr-in-Charge. Make:- Cera Cat Part No F 7010503AB or of equivalent model in other makes as listed in Appendix 'C.
S & F 100 mm dia SS grade 304 cockroach type floor trap (grating, inner & outer filter with frame) fixed with cement mortar (1:4) including all accessories complete all as specified & directed.
S&F in repair 15 mm bore pillar taps swan neck cast copper alloy,with capstan heads,chromium plated,screwed down, fancy type high pressure, with or without lettred 'HOT or COLD' with long screwed sunk and fly nuts complete all as specified and as directed by Engr-in-Charge. Make:- Cera Cat Part No F 2008105 or of equivalent model in other makes as listed in Appendix 'C.
S&F in repair sink with drainage board made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes including bedding in cement morter to dwarft wall or including fixing cantilever brackets and connecting union to pipe overall size 685mmx410 mm bowl size 355 mm x 305mm x 150mm or nearest size of make NIRALI brand name JUNIOR or equivalent model in other makes as listed in Appendix 'C. all as specified and as directed by Engr-in-Charge.
M&L in repair 75 mm dia PVC(SWR) multi floor trap with grating including jointing with solvent cement complete all as specified and directed.
Demolition of cement concrete in ground floor & paving n. exc 15 cm thick (below or above GL) unreinforced complete all as specified and directed.
Material and labour for PCC 1:4:8, type D2 (using 40 mm graded stone aggregate) as in foundation filling, mass concrete and sunken floor treatments complete all as specified and directed.
Material and labour for water proofing treatment to sunken slab, walls, etc, and shall be carried out as specified below and as directed.
(a) Clean the sunken portion of toilet / Baths/ WCs/ Kitchen thoroughly to remove laitance, dirt, dust etc.
(b) Form angle fillet of size 40 mm x 40 mm along the junction of wall and floor using polymer modified mortar (“ Dr fixit” Pidicrete URP” or eqvt).
(c) Sanitary pipes entering through walls and floor shall be sealed with “Dr Fixit Bath seal Tape” and the gaps to be grouted with non-shrink cementitous grout “Dr Fixit Bath seal Grout” or eqvt. Nahani traps etc to be fitted securely and the gaps around it to be grounted in the same manner.
(d) Apply one coat of a Bitumen-modified polymer coating “Dr Fixit Bath seal Plus” or eqvt on all angle fillets by brush and cover it with 100mm open woven mesh when it is still wet. Apply second coat of the same coating on the angle fillets and allow it to dry completely.
(e) In the remaining area, in dry substrate condition brush apply first coat of the same coating and further apply second coat when first is dry. Extend the coating upto 150mm above the FFL. Above FFL, another cementitious waterproofing waterproof coating “Dr Fixit Pidifin 2 K” or eqvt can be further applied right upto 2.1 m to waterproof the shower area also, if it is a bathroom or bath cubicles of a sanitary annex and apply second coat after 6-8 hours and allow to dry completely.
(f) After 2 to 3 days, sunken portion must be overlaid with a 50 mm thick concrete screed 1:3:6 type B0 mixed with integral WPC (Liquid) laid to slope 1:60 towards outer face of wall. Provide 40 mm OD UPVC pipe at the lowest point with 300 mm projection beyond the outer face of the wall. Then fill up the sunken portion with lean concrete 1:5:10 type E2.
(g) After completing plumbing work in the toilet/WC/Bath/Kitchen floor, tiling work (floor and dado) can be carried out using suitable Tile Adhesives and ready to make tile grouts of approved makes such as Dr Fixit, FOSROC, SIKA etc.
Material and labour for rendering 10 mm thick in CM (1:4) on fair faces of brickwork or concrete surfaces, with using liquid water proofing compound @ 200 ml per 50 kg bag of cement or as per manufracture's instructions, finished even and smooth without using extra cement complete all as specified and as directed. Note: WPC shall be measured and paid for seperately under relevant item.
S & F in repairs vitreous China squatting pan of Orissa pattern cat part No. CLOVIN S3010110 of CERA or of equivalent model in makes as specified in Appx 'C' with P or S trap of size 580 mm X 440mm white with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap and to flushing pipe incl lime concrete bedding and connection to antisyphonage pipe etc including making good to floor.
Taking down Chowkats and shutters of windows/ventilators with wire mesh / glass and MS grills of any size including all fittings and fixtures complete all as specified and directed.
Supply & fix sheet glass, ordinary quality, 5.5 mm thick and glazed with oil putty or fixed with rubber beading in square not exceeding 0.5 Sqm in each pane complete all as specified and directed.
S&F of aluminium alloy wire cloth, 0.45 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with aluminium wire staples complete all as specified and directed.
Supply and fix of Aluminium anodized deco grill Cat No DG-916, 7.5 mm thick ,cut to required size/shape and fixed in position with aluminium beading complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old painted steel surfaces of any description not otherwise described over 10cm in width or girth and applying one coat of synthetic enamel paint (up to any height) including scaffolding where required for external painting complete all as specified
M&L for preparation of old painted steel surfaces of any description not otherwise described over 10cm in widht or girth and applying two coat of synthetic enamel paint (upto any height ) including scaffoldings where required for external painting complete all as specified.
M & L for old loose spalled concrete should be chiseled from roof ceiling with the help of scrapers chisele & hammer after that cleaning of rust from mild steel rod applying cement slurry spray 3.00 kg per sqm by paint brush over cleaned surface for 8-10mm Thick ready mix plaster in for ceiling on brick wall or concrete surfaces including making groove of appropriate size and finished even & smooth witjhout using extra cement including three coat of white wash complete all as specified and as directed.
M&L for Ist and premium quality of anti skid, joint free, ceramic digital “coloured” matt finish tiles of premium or first quality of size 300 x 300 x 6-7mm or thick, in floor, shelves etc, set and jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles over and including 15mm thick screed bed or bedding layer in cement mortar 1:6 complete of item all as directed.
Complete removal of existing treatment on Old Internal wall surfaces of any desciption , preperation of surface by Mechanised sander having suction vaccum Bag using Smart periodical methodology , complete all as specified and M&L for the following : :- (a) Applying not less than 1.5mm thick wall care putty in two coats (Total thickness in two coats shall not be less than 1.5mm) on wall surface and smoothening the surface with Mechanised sanding etc prepatory to paint as directed complete all as specified (b) applying two coat of acrylic emulsion distemper of approved tint over a coat of acrylic primer on prepared surface as (a) above by using Airless spray over complete all as specified complete all as specified Note: Contractor shall use mechanized sanding tools for complete removal and Surface preparation by Air spray machine Trucare-graco-ultramax-490-pc-pro or equivalent approved by GE.
S&F in repair 20 mm dia decorative type curtain rods chromium plated anodised aluminium alloy with fixing brackts and all other connected works complete all as specified and directed.
S & F Curtain rod side designer aluminium anodized bracket of approved quality complete all as specified and directed by Engr-In-Charge.
S&F in repairs stainless steel plate racks of size 31" x 24" x 10" (or nearest size) conforming to cat part No. SSKPR-313 of Silver Shine or of equivalent model in other makes specified in Appendix 'C' complete all as specified & directed.
Taking down door chowkhat with shutter area n-exc 1.5 Sqm each(without taking off shutters from the frame) complete all as specified and directed.
Taking down door chowkhat with shutter area exc 1.5 Sqm n exe 4.00 sqm each(without taking off shutters from the frame) complete all as specified & directed.
Taking down shutters of any description n exc. 1.00 sqm each complete all as specified and directed.
Taking down shutters of any description exc. 1.00 sqm but n.exc. 2.00 sqm each complete all as specified and directed.
Supplying and fixing factory made single extruded WPC (Wood Polymer Composite) solid door Frames/Chowkhat comprising of 100 MM X 50 MM size applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete all as specified and directed
Supplying and fixing factory made single extruded WPC (Wood Polymer Composite) solid door Frames/Chowkhat comprising of 120 MM X 50 MM size applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete all as specified and directed
S&F factory made 35 mm thick flush shutter solid core construction with block board core & plywood face panels commercial type on both sides laminated incl 5mm thick teakwood leaping alround complete all as specified & directed.
S & F factory made 35 mm thick machine pressed architects veneer designer ply lam both side flush door shutter, solid core construction with block board core incl 5mm thick teakwood lipping alround with centrally locking arrangement with Lock of make Godrej of Link, 7 lever with Door eye, PVC buffer, door stopper and self-closing Device complete all as specified and as directed by Engr-in-Charge
Taking down shutter of any size including fitting and refixing in same position including easing complete all as specified & directed.
S&F 18 to 19 mm thick HDHMR board, prelaminated one side with decorative choice lamination exterior grade, fixed with screws to frame work as in cup board & kitchen cabinet shutters and all other similar works complete all as specified and directed. Make: Action Tesla/ Green Ply/ Century Ply
S & F of round stainless steel cabinet knobs/drawers handlers dia of 27mm complete all as specified and directed. Make:- Godrej Kitchen fittings and Sleek by Asian Paints
S & F 2nd class hard wood 35mm thick factory made, glazed and skeleton shutter open rebated and prepared to receive glass,gauge,etc. (with sash bars), edges of framing plain,chamfered or rounded fitted with cut and mitred beads for securing glass,etc; The size of the rail and stile as per IS 1003 (Part-I), Kiln seasoned and chemically pressure treated.
M&L for preparation of new wood or wood based surfaces, of any description, not otherwise described over 10 cm width or girth and apply two coats of synthetic enamel paint over a coat of pink primer complete .
M&L for preparation of old wood or wood based surfaces, of any description, not otherwise described over 10 cm width or girth and apply two coats of synthetic enamel paint complete all as specified .
Cutting holes in brick walls built in cement or cement lime mortar for inserting hold fasts, etc and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B-1 cutting exceeding half brick but not exceeding one brick complete.
S & F mild steel flat iron as in hold fast clamps articles conforming to FE 410 -O or FE 310-O complete all as specified and directed.
S&F stainless steel grade 304 butt hinges medium weight of size 100 mm fixing complete as specified by Engr-in-Charge.
S&F stainless steel grade 304 butt hinges medium weight of size 75 mm fixing complete as specified by Engr-in-Charge.
S&F stainless steel grade 304, 150 mm decorative type pressed handle fixing complete as specified by Engr-in-Charge.
S&F stainless steel grade 304, 200 mm long barrel tower bolt fixing complete as specified by Engr-in-Charge.
S&F stainless steel grade 304, 300 mm long SS sliding door bolt plate type decorative with bright bolt not less then 12 mm dia with and incl min of 6 bolt and nuts, four on bolt plate and two on staple fixing complete as specified by Engr-in-Charge.
S & F factory made single extruded WPC (Wood Polymer Composite) solid door Frames/ Chowkhat comprising of 62 mm x 32 mm size applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum specification as per IS 15931: 2012 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast unserviceable fast/lugs/SS dash fasteners of required dia and length complete all as specified and as directed by Engr-in-Charge. Make:- M/s Navratan Specialty Chemical LLP (Gujrat)/ M/s Sintex Industries Ltd/ M/s Accucell/ M/s Dura Plast Extrusion
S & F factory made 28-30 mm thick single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size, modulus of elasticity 850 N/mm” and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/ moisture proof specification as per IS 15931: 2012 and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws complete all as specified and as directed by Engr-in-Charge. Make:- M/s Navratan Specialty Chemical LLP (Gujrat)/ M/s Sintex Industries Ltd/ M/s Accucell/ M/s Dura Plast Extrusion
S&F 200 mm long aluminium anodized barrel tower bolt of extruded section complete all as specified and directed
S&F 100 mm long Aluminium butt hinges of extruded aluminium alloy with galvanized mild steel hinge , pin anodized complete all as specified
S&F 150 mm long aluminium alloy handle cast type anodized. complete
Demolition and breaking up drain pipes (SGSW, AC or RCC, CI ) of internal dia 75/110 mm, set in cement mortar complete.
S & F in repairs 110 mm dia PVC (SWR) pipes, type B, single socketed in any length with rubber ring joints, sealed with adhesive suitable for PVC pipes and fixed to walls to pipe difference 100 mm including stack clamps out of 50 mm x 5 mm flat iron and 16 mm dia round iron stays including all steel scaffloding arrangments complete all as specified and directed by Engr-in-charge.
S & F in repairs 75 mm dia PVC (SWR) pipes, type B, single socketed in any length with rubber ring joints, sealed with adhesive suitable for PVC pipes and fixed to walls to pipe difference 100 mm including stack clamps out of 50 mm x 5 mm flat iron and 16 mm dia round iron stays including all steel scaffloding arrangments complete all as specified and directed by Engg-in-charge.
S&F PVC (SWR) bends any radius, 110 mm bore complete at any height including steel scaffold complete all as specified and directed by Engg-in-charge.
S&F PVC (SWR) bends any radius, 75 mm bore complete any height including steel scaffold complete all as specified and directed by Engg-in-charge.
S&F for PVC (SWR) branch piece, single ( single Y) equal or unequal radius, 110 mm bore complete any height including steel scaffold complete all as specified and directed by Engg-in-charge.
S&F for PVC (SWR) branch piece, single ( single Y) equal or unequal radius, 75 mm bore complete any height including steel scaffold complete all as specified and directed by Engr-in-charge.
S&F for PVC (SWR) branch piece, single ( single T) equal or unequal radius, 110 mm bore complete any height including steel scaffold complete all as specified and directed by Engr-in-charge.
S&F for PVC (SWR) branch piece, single ( single T) equal or unequal radius, 75 mm bore complete any height including steel scaffold complete all as specified and directed by Engr-in-charge
S&F for PVC (SWR) reducers, 110 mm bore complete any height including steel scaffold complete all as specified and directed by Engr-in-charge.
S&F for PVC (SWR) reducers, 75 mm bore complete any height including steel scaffold complete all as specified and directed by Engr-in-charge.
S&F for PVC (SWR) vent cowl, 110 mm bore complete any height including steel scaffold complete all as specified and directed by Engr-in-charge.
S&F for PVC (SWR) "P" trap, 110 mm bore complete any height including steel scaffold complete all as specified and directed by Engr-in-charge.
Note for item no. 114 to 125 :- The unit rate quoted by the contractor shall be deemed to be inclusive of use and waste of steel scaffolding.
S&F for PVC (SWR) "P" trap, 75 mm bore complete.
S&F for PVC (SWR) "Q" trap, 110 mm bore complete.
S&F for PVC (SWR) "Q" trap, 75 mm bore complete.
Dismantling of cast iron drain pipes of internal dia 100 mm, jointed in cement mortar and taking out of trenches, if required complete.
S&F for 100 mm bore cast iron spun soil waste pipes in any length with or with out ears with cement joints laid in floors all as specified.
Supplied and fixed cast iron bends 100 mm bore dia, diminishing pieces fitted with oval excess door all as specified.
Supply and fix cast iron nahani trap 100 mm dia including grating, jointing to waste pipe fixed in cement concrete type B1 (1:2:4) complete all as specified.
S & F in repairs Cast iron floor trap with grating including jointing to waste pipe in run lead, dia of outlet 100 mm complete all as specified and directed .
S&F Roof sheeting prepainted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any profile and colour as directed having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws as specified.
Supply & fix joist, channel, angle, tee sections, & MS flats fixed independently, without connection plate, etc. (cut to ordinary lenghts i.e. within 20mm of the length indicated) for purlins fixed to wooden rafters and all other similar works conforming to Fe 410-W (Gde-E-250) quality-A complete all as specified and directed including old existing wrought iron work.
M&L Matt finish full body vitrified tiles of shade, pattern and design as approved by GE, 10 mm thick (Square/rectangular) polished area of each tile exceeding 0.64 sqm but not exc 0.72 sqm in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match inluding Screed bed or bedding layer of mortar 15 mm thick in (1:6) for laying floor finishes complete all as specified.
M&L light shade vitrified coloured Ceramic tiles 10 mm thick (Square/rectangular) polished area of each tile exceeding 0.64 but not 0.72 sqm in vertical surfaces such as skirtings and dados set and jointed in neat cement slurry and pointed in white or coloured cement to match over rendering 10 mm thick on fair faces of brick work in CM (1:4) complete all as specified.
S & F of 18mm thick Marine Plywood laminated of any colour with High glossy acrylic sheet of 3mm thick , grade I as per IS 14587, for frame and shutter for kitchen cabinets complete all as specified and directed by Engr-in-charge.
S & F of medium weight, cold rolled mildsteel, SS finish, (Partial overlay/fully overlay of any type) diameter of cup 35mm, Hinge cup depth 11.5mm, soft-closing complete all as specified and directed by Engg-in-charge. Make : Godrej Kitchen fittings or equivalent in Sleek by Asian Paints
S & F of stainless steel 304 grade electro-polished for corrosion resistance modular thali holder / basket having size of 42 x 58.5 x 20 cm including telescopic drawer channel having weighing capacity of 6 kg complete all as specified and directed. Make : Cat Part No 5704 Godrej Kitchen fittings or equivalent in Sleek by Asian Paints
S & F of stainless steel 304 grade electro-polished for corrosion resistancemodular cup & saucer holder / basket size of 52 x 53.5 x 10 cm with telescopic drawer channel having weighing capacity of 4kg complete all as specified and directed. Make : Cat Part No 5837 Godrej Kitchen fittings or equivalent in Sleek by Asian Paints
S & F SS 304 grade 200mm length stainless steel cabinet drawers handles complete all as specified and directed. Make:- Godrej Kitchen fittings and Sleek by Asian Paints
S & F in repairs of stainless steel grain trolley SS 304 grade having size of 525x485x350mm, with heavy duty and grade steelwith finish of zinc, corrosion resistance with telescopic drawer channel having weighing capacity of 25 kg complete all as specified and directed. Make : Cat Part No-6175 of Godrej Kitchen appliances.
S & F in repairs of stainless steel Plane wire Basket/ trolley SS 304 grade having size of 506x480x200mm, with heavy duty and grade steelwith finish of zinc, corrosion resistance with telescopic drawer channel having weighing capacity of 25 kg complete all as specified and directed. Make : Cat Part No-4265 of Godrej Kitchen appliances.
S&F stainlesss steel modular perforated cutlery basket SS 304 grade of size 52x48.5x10 cm with telescopic drawer channel having weighing capacity of 6 kg complete all as specified and directed. Make Godrej kitchen appliances or equivalent.
S&F stainless steel 304 grade Size 180x515x485 mm pull out detergent rack Cat No ASSEDP180510485 having two shelf spaces with telescopic drawer channel having weighing capacity of 6 kg complete all as specified and directed. Make: Godrej Kitchen Appliances or equivalent as approved by GE.
Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Demolition of re-inforced cement concrete (re-inforce cut as required to facilitate demolition) in any position ( Beam, landing Chajja and Roof slab etc ) ground floor/ other than ground floor ,projection of balcony complete complete all as specified and directed.
M&L for Providing 2 to 2.50mm thick FRP chajja of approved pattern/shape/size (with sides & front drop etc), colour/pattern as of Mangalore clay tile (the FRP chajjas shall be moulded in gel coat finish, the thickness shall be 4 mm and back patti to be additionally reinforced with core matt, all resins and pigment shall be fully weatherable and UV established, core malt shall be used with GSM for extra thickness, necessary FRP covered metal), chajjas shall be fixed in position with and including 8mm dia and 125mm long split fastener bolts (Shakti or equivalent as approved by the GE) spaced not more than 45cm C/C and also filling the gaps with polysulphide sealant including necessary scaffolding/erection of working platform etc, complete all as specified and directed. Make : M/S Titan Enterprises or Advance FRP or Sintex.
Supplied and fixing of framed work such as grills, gratings etc with ends of bars shouldered and/or riveted or forged into spikes , framed guard bars, barred iron doors, ladders,windows, balcony in ground floor, framed balusters, walk ways, railings, framework of watertanks and similar work conforming to FE 290 Gde -E-165 complete all as specified and directed.
M&L for SS 304 grade stainless steel (Square/Round/Rectangular) of suitable gauge as in SS guard bars, railings, SS frame works as in windows , balcony , including all fixing arrangments, including taking down of old guard railing complete all as specified and directed.
Demolition of brick work or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles complete all as specified and directed.
M&L for brick work with Fly ash bricks straight or curved on plan exc 6 mtr mean radius built in CM 1:6 complete all as specified & as directed.
Excavation in trenches n exc 1.50m wide and nexc 1.50m in depth for foundation etc n exc 10sqm on plan and nexc 1.50m in depth and getting out in soft loose soil complete all as specified and directed.
M&L for PVC (SWR ) gully trap 125/110mm and jointing with solvent cement and fixed in position complete all as specified and directed incl concrete type B1(1:2:4) complete in repairs (with wpc note: wpc will be measured and paid seperately)
Material and labour for cement concrete 1:4:8 type D-2 using 40 mm graded coarse aggregate in bed to drain pipes of 150 mm bore Concrete bed s including packing under, and haunching against the sides of pipes after they are laid and tested; in complete all as specified and directed .
M & L for 150 mm bore (internal dia of pipe) reinforced concrete pipes, Class NP3 laid in trenches and jointed with CM (1:1) complete all as specified and as directed.
Removing excavated (soil) materials and deposited out of MD land up to a distance of 15 km all as per directed.
M&L for any coloured digital ultra strong / heavy duty outdoor anti skid vitrified tiles 15-18 mm thick (Square / Rectangular) polished area of each tile exc 0.09 Sqm and not exc 0.36 sqm, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match the shade of tiles and including 20 mm thick in cement plaster in CM (1:4) for fixing tiles anywhere complete all as specified and directed.
S&F High density polyethylene pipes(HDPE) of pressure rating 6 kgf/cm2 of 38/40mm bore fixed complete to walls,ceilings or in floors etc complete all as specified and directed.
S&F High density polyethylene pipes(HDPE) of pressure rating 6 kgf/cm2 of 32mm bore fixed complete to walls,ceilings or in floors etc complete all as specified and directed.
Returning, filling, including spreading, leveling, watering and well ramming in layers not exc 25 cm all as specified and directed.
Supplying & fixing to walls and ceiling 40 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Disconnecting existing tanks of any capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately) complete all as specified and as directed.
S & F 40 mm gun metal, globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed to pipe complete
M&L for PCC 1:2:4 type B 2 as in hardstanding , plinth protection 75mm thick (using 40mm graded aggregate) including necessary expansion joints and filling joints with bitumen complete all as specified and directions
M & L for Machine cut cudappah stone slab 20-25mm thick over cement screed base, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
Taking up or down steel tubing and connection including cleaning for refixing or removed to store,40 mm dia bore complete all as specified and directed
S & F GI tubing 40 mm bore medium grade medium grde with all fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and directed
M & L for Hard drawn steel welded wire fabric mesh ,100 x 100 x 3mm dia cut to lengths bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm in dia supplied anchored over 3 to 4 inch long iron nails at a distance of 0.6 m in both direction and fixed in walls / reinforcemnt weight not less than 1.37 Kg/Sqm but not exc 4kg per sqm for fixing and for bracing, supporting or otherwise holding firmly in position so that the placing and ramming of concrete will not displace it. The rates include for straightening, raking or circular cutting and waste. Rates also include for straightening where reinforcement is supplied in rolls/coil.
M & L for removing loose, disturbed or disintegrated old concrete / brick surfaces of walls, RCC beam, column, lintel, pardi, railing etc, cleaning thoroughly exposed reinforcement, by sand blasting using suitable pump as directed by the GE, preparing exposed concrete surfaces to receive guniting, applying one coat of anti corrosive paint to the exposed reinforcement, applying pressure guniting in cement mortar 1:3, average thickness 30mm to 50mm and thereafter rendering 10 mm thick plaster in cement mortar 1:3, mixed with water proofing compound in the ratio as per the manufacturer's instructions and finishing the surfaces even and smooth without using extra cement to match with the existing surfaces, removing the debris outside MD land including material and labour and safety arrangement for guniting work, complete all as specified and directed. (Note :- (i) The finished level of the surfaces shall be matched with the existing surface. WPC shall be measured & paid separately as supply only). (ii) Provision of additional reinforcement steel in case required and ordered shall be measured and paid separately.
S & F Plastic tyres and steel ball bearing 25 mm dia with load capacity 40 Kg cabinet drawer roller complete all as specified and directed by Engr-in-charge (For built in cup boards). Make: Door set/sleek(Asian Paints) or equivalent as approved by GE.
S & F stainless steel cabinet drawer multi lock single latch 40 mm size fixed complete all as specified and directed by Engr-In-charge (For built in cup boards). Make: Door set/sleek(Asian Paints) or equivalent as approved by GE.
S & F 50 mm magnet PVC coating MS complete cabinet drawer Magnet complete all as specified and directed by Engr-in-charge (For built in cup boards). Make: Door set/sleek(Asian Paints) or equivalent as approved by GE.
S & F MS with black coating 550 mm long with load capacity 40 Kg cabinet drawer channel fixing with screws complete all as specified and directed by Engr-in-charge (For built in cup boards). Make: Door set/sleek(Asian Paints) or equivalent as approved by GE.
Taking down carefully copper/aluminum point wiring (light, fan, socket or power) complete including all fittings and fixtures such as switches, pendant, lamp holder, regulators, switch socket outlet, bulk head fittings, tube light fittings etc and removing unserviceable materials from site of work and making good disturbed surfaces of walls, floors with cement mortar and white/colour wash to match with existing surfaces etc complete all as specified and directed
Taking down carefully copper/aluminum submain wiring complete and making good disturbed surfaces of walls, floors with cement mortar and white/colour wash to match with existing surfaces etc complete all as specified and directed
Material & Labour for Point wiring (concealed type) with 1.5 sq mm, PVC insulated unsheathed (FRLSH), 1100 volts grade, ,single core, multi-stranded copper conductor,and continuous earth wire unsheathed (FRLSH), single core multi-stranded copper conductor cable of size 1.5 sq mm earth continuity conductor conforming to IS: 694-2010, connected to common earth dolly, colour coding of wire shall be Red wires for phases, black wire for neutral and green wire for earth, drawn in and including rigid non-metallic PVC medium duty conduit (ISI mark) of size 19/20 mm dia including cutting chases for conduits, sinking for boxes for concealed conduit wiring with all fittings and accessories including conecaled MS / pressed steel sunken box not less than 1.6 mm thick, suitable for fixing moduler switches/ sockets , and making good to the disturbed surfaces to match the existing surfaces complete (fill up cement in gaps, finishing with putti and apply two coats of paint, match with existing colour in disturbed surface area), and as specified complete for one light point / bell/ Ex Fan / wall fan controlled by one modular switch, 1 way 6/10 amps, 1 module.
All as per Item No. 178 here-in but for bell point controlled by one switch.
All as per Item No. 178 here-in but for one light point controlled by two, 2 way switches
All as per Item No. 178 here-in but for One ceiling fan point controlled by one switch & regulator
All as per Item No. 178 here-in but for One 3 pin socket point 5 Amps on independent board
All as per Item No. 178 here-in but for One 3 pin socket point 5 Amps on same board
All as per Item No. 178 here-in-before but for one modular socket point 15 Amp with 2.5 sq mm sq mm, PVC insulated unsheathed (FRLSH), 1100 volts grade, ,single core,multi-stranded copper conductor,and contineous earth wire unsheathed (FRLSH) ,single core multi-stranded copper conductor cable of size 2.5 sq mm earth continuity conductor Conforming, to IS :694-2010, connected to common earth dolly complete all as specified & as directed by Engr-in-charge.
S&F Switch Modular, flush type single pole, one way 6/10 Amp, 1 module, 230 V AC, 50 Hz ISI marked all as specified and directed.
S&F Modular Switch, flush type single pole, one way 16 Amp, 1 module, 230 V AC, 50 Hz ISI marked all as specified and directed
S&F Modular socket 6 Amp, 2/3 pin combined 2 Module, 230 V AC, 50 Hz ISI marked all as specified and directed
S&F Modular socket 6/16 A, 2/3 pin combined 2 Module, 230 V AC, 50 Hz ISI marked all as specified and directed.
S&F Modular stepped type electronic fan regulator 100 watt flush type, two module, 230 V AC ISI marked all as specified and directed.
S&F Modular bell push 6 A, 1 module, 230 V AC, 50 Hz ISI marked all as specified and directed.
S&F ceiling rose surface bakelite 65 x 50 mm two to three terminals, 230 V AC complete all as specified and as directed.
S&F Modular Switch, flush type single pole, two way 6 Amp, 1 module, 230 V AC all as specified and directed.
Supply and fix cover plate with frame 2 module
Supply and fix cover plate with frame 3 module
Supply and fix cover plate with frame 6 module
Supply and fix cover plate with frame 8 module.
M&L for Point wiring (concealed type) with 1.5 sq mm, PVC insulated unsheathed (FRLSH), 1100 volts grade, single core, multi-stranded copper conductor and continuous earth wire unsheathed (FRLSH), single core multi-stranded copper conductor cable of size 1.5 sq mm earth continuity conductor conforming to IS: 694-2010, connected to common earth dolly, colour coding of wire shall be Red wires for phases, black wire for neutral and green wire for earth, drawn in and including rigid non-metallic PVC medium duty conduit (ISI mark) of size 19/20 mm dia including cutting chases for conduits, sinking for boxes for concealed conduit wiring with all fittings and accessories including conecaled MS / pressed steel sunken box not less than 1.6 mm thick, suitable for fixing switches/ sockets, and making good to the disturbed surfaces to match the existing surfaces complete (fill up cement in gaps, finishing with putty and apply two coats of paint, match with existing colour in disturbed surface area), and as specified complete for one light point / bell/ Ex Fan / wall fan controlled by one modular switch, 1 way 6/10 amps, 1 module.
All as per Item No. 197 here-in but for bell point controlled by one switch.
All as per Item No. 197 here-in but for one light point controlled by two 2 way switches
All as per Item No. 197 here-in but for One ceiling fan by one switch & regulator
All as per Item No. 197 here-in but for One 3 pin socket point 5 Amps on independent board
All as per Item No. 197 here-in but for One 3 pin socket point 5 Amps on same board
All as per Item No. 197 here-in-before but for one socket point 15 Amp with 2.5 sq mm, PVC insulated unsheathed (FRLSH), 1100 volts grade, ,single core,multi-stranded copper conductor,and contineous earth wire unsheathed (FRLSH) ,single core multi-stranded copper conductor cable of size 2.5 sq mm earth continuity conductor Conforming, to IS :694-2010, connected to common earth dolly complete all as specified & as directed by Engr-in-charge.
S&F Switch piano, flush type single pole, one way 6 Amp, 230 V AC, 50 Hz all as specified and directed.
S&F Switch piano, flush type single pole, one way 16 Amp, 230 V AC, 50 Hz all as specified and directed.
S&F socket outlet 2 in 1, 3 pin 6 Amp, 230 V AC, 50 Hz all as specified and directed.
S&F socket outlet 2 in 1, 3 pin 6 and 16 Amp flush type, 230 V AC, 50 Hz all as specified and directed.
S&F stepped type electronic fan regulator 120 watt flush type on the existing phenolic laminated sheet etc. all as specified and directed.
S&F bell push type 5 Amp, 230 V AC 50 Hz all as specified and directed.
S&F Switch piano, flush type single pole, two way 6 Amp, 230 V AC, 50 Hz all as specified and directed.
Supply and Fix 20 watt LED tube light fitting in repair, 4 feet long fitting extruded polycarbonate housing and robust construction LED lighting fixture with high lumen output, environmental friendly, energy efficient CRI-6500K, P.F. not less than 0.95, fixed on PVC square for mounting the fittings and electrically connecting with three core 23/0.0076. PVC insulated multi strandard copper flexible cable from ceiling rose to light fitting ((connector of lamp fitting ) and one for earthing complete all as specified and directed. Make : Wipro Cat No LL20-221-XXX-65 NE3 **6500K/ Havells Cat No LHEXBLP7PN1W020/ Halonix Cat No. HLB-08-20-CW-IP
Supply and fix surface mounted 9/10 watts LED tube light fitting in repair, 2 ft long light fitting with square batten LED lighting fixture with high lumen output, environmental friendly, energy efficient . fixed on PVC square for mounting the fittings and electrically connecting with three core 23/0.0076 PVC insulated multi strandard copper flexible cable from ceiling rose to light fitting (connector of lamp fitting) and one for earthing complete all as specified and directed Make: Wipro Cat No LL20-111-XXX-65 NE3 **6500K/ Havells Cat No LHEXBLP7IN1W009/ Halonix Cat No. HLB-07-10-CW-IP
S&F in repairs decorative wall mounting fitting, in LT opal glass with nickel finish suitable for 6W/ 7W/ 9 W LED lamp working on 240 volts, 50 hz ac including led bulb of capacity 9 watt complete all as specified and directed. Make for fitting: Jaquar Cat Part No: JNL-CHR-WL SL55004E27/ Philips Cat No 34143/ Havells Cat Part No. LHFOAJE1TZ1I060
S&F in repairs Supply of adjustable LED bedside lighting with a gooseneck arm,premium material and finish and is easy to adjust according to theuser. The lumen output of the fitting should be minimum 400 lumenswith a CCT of 3000K and the wattage should be 3 W suitable with including LED lamp B22 Base working on 240 volts, 50 Hz AC complete all as specified and directed. Make OF Fitting : Philips cat No 48042 /Havells or Wipro
Supply and fix LED 18 Watt fitting in repair, minimum 110 Lumen per Watt, circular type surface mounted LED downlighter warm white 3000K with white powder coated aluminium housing with integrated electronic driver of same make connecting cable three core PVC insulated and PVC sheathed copper flexible cable of size 16/0.20 mm and necessary fixing arrangement complete all as directed. Make - Philips Cat No SM296C LED20S-3000 PSU WH/ Bajaj Cat No BPSLR Surface 18 W WW/ Wipro Cat No 641865
Supply and fix calling bell ding dong type 230 volts all as specified and directed
Supply and fix Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings
Material and labour for sub main wiring with two single core 4 sq mm nominal area with 1100 Volt grade confirming to IS 694 (2010) PVC insulated unsheathed with one run of 4 Sq mm multi stranded copper conductor cable (FRLSH) ISI Marked for continuous earth wire drawn in and including Concealed rigid non-metallic PVC conduit (ISI mark) of size 19/ 20 mm dia medium grade with fitting (ISI) marked including cutting, chasing, for conduit and making good of walls etc complete all as specified and as directed Note : Two runs of cable and one run of earth cable & one RM of PVC conduit shall be measured as one length (ii) Cable for earth wire shall run inside the conduit (iii)Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. (iv) Rate quoted is deemed to be inclusive for cutting chases in wall for concealed wiring & making good disturbed surfaces to match existing.
Material and labour for sub main wiring with two single core10sq mm nominal area with 1100 Volt grade confirming to IS 694 (2010) PVC insulated unsheathed with one run of 10 Sq mm multi stranded copper conductor cable (FRLSH) ISI Marked for continuous earth wire drawn in and including Concealed rigid non-metallic PVC conduit (ISI mark) not less than 20 mm dia medium grade with fitting (ISI) marked including cutting, chasing, for conduit and making good of walls etc complete all as specified and as directed Note : Two runs of cable and one run of earth cable & one RM of PVC conduit shall be measured as one length (ii) Cable for earth wire shall run inside the conduit (iii)Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. (iv) Rate quoted is deemed to be inclusive for cutting chases in wall for concealed wiring & making good disturbed surfaces to match existing.
Material and labour for sub main wiring with two single core16sq mm nominal area with 1100 Volt grade confirming to IS 694 (2010) PVC insulated unsheathed with one run of 16 Sq mm multi stranded copper conductor cable (FRLSH) ISI Marked for continuous earth wire drawn in and including Concealed rigid non-metallic PVC conduit (ISI mark) not less than 25 mm dia medium grade with fitting (ISI) marked including cutting, chasing, for conduit and making good of walls etc complete all as specified and as directed Note : Two runs of cable and one run of earth cable in PVC conduit shall be measured as one length (ii) Cable for earth wire shall run inside the conduit (iii)Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. (iv) Rate quoted is deemed to be inclusive for cutting chases in wall for concealed wiring & making good disturbed surfaces to match existing.
Material and labor for sub main wiring with four single core 25 sq mm nominal area with 1100 Volt grade confirming to IS 694 (2010) PVC insulated unsheathed with 2 run of 16 Sq mm multi stranded copper conductor cable (FRLSH) ISI marked for continuous earth wire drawn in and including including Concealed rigid non-metallic PVC conduit (ISI mark) not less than 50 mm dia heavy grade with fitting (ISI) marked including cutting, chasing, for conduit and making good of walls etc complete all as specified and as directed Note: Four runs of cable and two run of earth cable in PVC conduit shall be measured as one length (ii) Cable for earth wire shall run inside the conduit (iii)Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. (iv) Rate quoted is deemed to be inclusive for cutting chases in wall for concealed wiring & making good disturbed surfaces to match existing.
S &F Modular type AC Box, 4 Module with Socket and 16 Amp SP mini MCB in plastic box enclosure along with cover plate and top complete all as specified and directed.
Supply and fix in repair sheet metal enclosure for DB when MCBs to be used 240 volts 2 way single door without bus bar single pole and neutral fixed on wall with the help of MS flat angle iron duly grouted on wall including MS nut and bolts complete all as directed by engr in charge
Supply and fix sheet metal enclosures, double door duly powder coated & IP-43, for DBs when MCBs to be used 240 volts 4 way with 200 Amps rated bus bar single pole and neutral fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection complete all as specified and directed.
Supply and fix sheet metal enclosures,metal double door duly powder coated & IP-43, for DBs when MCBs to be used 240 volts 8 way with 200 Amps rated bus bar single pole and neutral fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection complete all as specified and directed.
Supply and fix sheet metal enclosures, double door duly powder coated & IP-43, for DBs when MCBs to be used 240 volts 16 way with 200 Amps rated bus bar single pole and neutral fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection complete all as specified and directed.
S&F MCB DB VTPN 4 way in repair, metal double door load line powder coated IP 43 Protection With provision for 4 Pole MCCB as incomer and SP/TP MCBs as outgoings complete Provided with insulated vertical phase bus-bars neutral bars with shrouds,earth bars , sticking saddles, cement spill protector, color-coded interconnecting wire set , cable ties, blanking plates and circuit identification labels, fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection complete all as specified and directed. Note: (i) MCCB shall be measured & paid seperately
S&F MCB DB VTPN 6 way in repair, metal double door load line powder coated IP 43 Protection With provision for 4 Pole MCCB as incomer and SP/TP MCBs as outgoings complete Provided with insulated vertical phase bus-bars neutral bars with shrouds,earth bars , sticking saddles, cement spill protector, color-coded interconnecting wire set , cable ties, blanking plates and circuit identification labels, fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection complete all as specified and directed. Note: (i) MCCB shall be measured & paid seperately
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioning.
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of double poles and current carrying capacity 63 Amp, in the MCB DB Complete with connection testing and commissioning.
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of double poles and current carrying capacity 40 Amp, in the MCB DB Complete with connection testing and commissioning.
S&F 125 Amp MCCB, 415 Volts, 16 KA, 4 pole, fixed on TPN DB board in and including copper lugs/thimbles of size as per wire/cable including crimping for connection complete all as specified and directed.
S&F 63 Amp MCCB, 415 Volts, 16 KA, 4 pole, fixed on TPN DB board in and including copperlugs/thimbles of size as per wire/cable including crimping for connection complete all as specified and directed.
S&F 63 Amp FP, 415 Volts, fixed on TPN DB in and including copper lugs/thimbles of size as per wire/cable including crimping for connection complete all as specified and directed.
Notes for item No 223 to 234:- (i) MCBs, MCCB's shall be measured & paid for separately under respective items. (ii) MCB DB & MCBs, Isolator, shall be of uniform make.
Supply and fixing in repair LED building security light fitting 45 Watt with inbuilt driver, luminaire fixture in IP 66 protection level output of LED lamp efficiency minimum 100 lumen per watt after all losses, pressure die-cast aluminium housing LED Street light complete with GI clamp including connected accessories and bracket made of GI Pipe 40mm dia light grade 1.20 m long, bend to shape with two sets of MS flat iron clamps, nuts, bolts, washers etc. complete all as directed by Engineer-in-Charge. Make Philips : Cat No BRP 052 LED 045 CW SLMR FG S1 PSU GR or equivalent in Wipro cat part No LR02-501-XXX-57-XX or Havells ENDURASUNDOWNSL45WLED765PASYBOTG
Supply and fix / lay cable in repair PVC insulated screened PVC bedded, unarmoured, sheathed, electric power cables 1100 volts grade with stranded copper conductor of size 2.5 Sqmm 3 core with non metalic PVC FR, heavy duty conduit of suitable size (20mm dia or more), with shaddle complete all specified and directed Note: 3 core cable with PVC conduit shall be measured as one length for connecting all building street lights around the building.
Supply & Fix non-metallic PVC casing capping of size 25X12mm dia (for fixing the telephone cable and lan cable)
M&L Earthing complete with galvanised steel earth plate electrode 600mm x 600mm x 6mm thick, buried vertically in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers, electrode connected to and including galvanised iron earth lead strip of size 32mm x 6mm upto 7.5 m from earthing by means of bolts, nuts and washers of galvanised iron or steel including neccessary excavation and earth work in any type of soil, removal of surplus soil to a distance n. exc 50 m, PCC 1:3:6 type C-1 earth chamber of outer dimentions 60 cm x 60 cm x 60 cm and internal dimentions 30 cm x 30 cm x 45 cm with RCC 1:2:4 type B1 cover reinforced with 6mm dia mild steel round bars @ 15 cm c/c both way, mild steel angle iron frame made of MS angle iron of size 40mm x 40mm x 6mm duly painted with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer, GI pipe 40 mm dia light grade with required fittings for protection of GI earth strip from earth plate to test point / plant / machineries buried in ground, laid under floors/ plinths or fixes on walls or concealed in walls etc; both to be provided to the extent as required at site, 20 mm dia GI pipe medium grade for watering arrangements with funnel internally secured with wire mesh all as shown in electrical plate No.3 of SSR Part I, complete all as specified and directed, including testing on completion. (Note : GI earth strip and GI protection pipe upto 7.5 metre length shall be included in this item.)
Design, fabricate, supply, testing and commissioning of CPRI approved Meter box suitable for wall mounting arrenement of 10 Nos of electric meters, indoor type dust, vermin and rain water proof fabricated with 2.00 mm thick CRCA sheet steel power coated front openable vertical cubical type installed over properly supported min 0.20 Mtr long suitable grouted to wall including dismantling of existing conventional meter & depositing to AGE E/M store yard all as specified and directed.
S&F Blank MCB plate
Taking down & refixing the existing ceiling/exhaust fan after completion of rewiring work all as specified.
Taking down & refixing existing geyser including necessary fixing arrangement, Hot water connecting pipes etc complete all as specified ad directed by Engr-in-Charge.
S&F Blank MCB plate
MUKESH CONSTRUCTION CO
SANKALP INFRACON
SOOD ASSOCIATES PVT LTD
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid