| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.9 LAccepted-AOC PLOT NO 8 PREMA APARTMENT VEDANTNAGAR CHHATRAPATI SAMBHAJINAGAR 431 007 M S | CHHATRAPATI SAMBHAJINAGAR | CHHATRAPATI SAMBHAJINAGAR | MAHARASHTRA | 431007 | L1 | Accepted-AOC Being overall rate reasonable | |
| 2 | L2₹37.8 L+₹4.6 L (13.7%)Rejected-Finance | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹39.7 L+₹6.4 L (19.2%)Rejected-Finance THEERTHAM NADUVILEMURI PADANILAM POST NOORANAD ALAPPUZHA DIST KERALA 690529 | ALAPPUZHA | KERALA | 690529 | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹39.7 L+₹6.4 L (19.3%)Rejected-Finance 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹40.9 L+₹7.6 L (22.8%)Rejected-Finance | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
1 Jan 2022, 6:00 pmClosed
GE (CENTRAL) KIRKEE
GE (CENTRAL) KIRKEE, RANGE HILLS ROAD KIRKEE PUNE-411003
COMREHENSIVE REPAIR MAINT OF SUMMER APPLIANCE LIKE AC DESERT COOLER WATER COOLER DEEP FREEZER AND REPAIR MAINT OF INT WIRING AND ACCY GEYSERS FANT ETC OF MD AND OTM ACCN OF OFFRS JCO AND OR AT DUNKIRK LINE AREA UNDER AGE EM I IN GE C KIRKEE
2021_MES_492462_1
8548/E8 OF 2021-2022
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
KIRKEE
AS PER NIT
7 documents required · 7 mandatory
₹500
Yes
GE (CENTRAL) KIRKEE
₹96,000
Yes
24 Jan 2022
4 Dec 2021
3 Jan 2022
4 Dec 2021
1 Jan 2022
20 Dec 2021
4 Dec 2021 - 18 Dec 2021
Amount
Material & Labour for surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn in and including PVC casing caping of required size with all fittings and accessories alongwith one single core green colour PVC insulated 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly for one light point or one fan point or one call bell point controlled by one, one way switch including PVC switch board of required size or 3mm thick hylam sheet screwed with 04 nos cadmium coated screws & cup washer on existing MS concealled box for mounting of switch, regulators or bell push and casing caping terminal box for mounting ceiling rose/ holders etc incl dismentling taking down old unserviceable point wiring and making good to disturbed surfaces complete all as specified and directed by Engineer in Charge.
All as per item no 1 above but for one 5 Amp socket point on independent board complete all as specified and as directed by Engineer in Charge.
All as per item no 1 above but for one 5 Amp socket point on same board complete all as specified and as directed by Engineer in Charge.
All as per item no 1 above but for one two way light point controlled by two, two way switch complete all as specified and as directed by Engineer in Charge.
Material & Labour for surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 2.5 sqmm (Nominal area) drawn in and including PVC casing caping of required size with all fittings and accessories alongwith one single core green colour PVC insulated 1100 volt grade multi stranded FRLSH Copper conductor cable of size 2.5 sqmm as earth lead and connected to earth dolly for one 16 Amp socket (Power) point on independent board including PVC switch board of required size or 3mm thick hylam sheet screwed with 04 nos cadmium coated screws & cup washer on existing MS concealled box for mounting of switch, regulators or bell push and casing caping terminal box for mounting ceiling rose/ holders etc incl dismantling taking down old unserviceable point wiring and making good to disturbed surfaces complete all as specified and directed by Engineer in Charge.
Material & Labour for surface sub main wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn through in and including PVC casing caping/PVC conduit size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly incl dismentling taking down old unserviceable wiring and making good to disturbed surfaces complete all as specified and directed by Engineer in Charge. NOTE: (a)Two run of cable with one run of earth wire and one run of casing caping/conduit shall be measured as one length.
Material & Labour for surface sub main wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 2.5 sqmm (Nominal area) drawn through in and including PVC casing caping/PVC conduit size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 2.5 sqmm as earth lead and connected to earth dolly incl dismentling taking down old unserviceable wiring and making good to disturbed surfaces complete all as specified and directed by Engineer in Charge. NOTE: (a)Two run of cable with one run of earth wire and one run of casing caping/conduit shall be measured as one length.
Material & Labour for surface sub main wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 4.0 sqmm (Nominal area) drawn through in and including PVC casing caping/PVC conduit size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 4.0 sqmm as earth lead and connected to earth dolly incl dismentling taking down old unserviceable wiring and making good to disturbed surfaces complete all as specified and directed by Engineer in Charge. NOTE: (a)Two run of cable with one run of earth wire and one run of casing caping/conduit shall be measured as one length.
Material & Labour for surface sub main wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 6.0 sqmm (Nominal area) drawn through in and including PVC casing caping/PVC conduit size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 6.0 sqmm as earth lead and connected to earth dolly incl dismentling taking down old unserviceable wiring and making good to disturbed surfaces complete all as specified and directed by Engineer in Charge. NOTE: (a)Two run of cable with one run of earth wire and one run of casing caping/conduit shall be measured as one length.
Material & Labour for surface sub main wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 10.0 sqmm (Nominal area) drawn through in and including PVC casing caping/PVC conduit size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 10.0 sqmm as earth lead and connected to earth dolly incl dismentling taking down old unserviceable wiring and making good to disturbed surfaces complete all as specified and directed by Engineer in Charge. NOTE: (a)Two run of cable with one run of earth wire and one run of casing caping/conduit shall be measured as one length.
Material & Labour for surface sub main wiring with four single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 10.0 sqmm (Nominal area) drawn through in and including PVC casing caping/PVC conduit size with all fittings and accessories alongwith two single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 10.0 sqmm as earth lead and connected to earth dolly incl dismentling taking down old unserviceable wiring and making good to disturbed surfaces complete all as specified and directed by Engineer in Charge. NOTE: (a) Four run of cable with two run of earth wire and one run of casing caping/conduit shall be measured as one length.
Supply & Fix 5 Amp switch piano type, single pole, one way including dismantling and taking down unsv one complete all as specified and as directed by Engineer in Charge.
Supply & Fix 5 Amp switch piano type, single pole, two way including dismantling and taking down unsv one complete all as specified and as directed by Engineer in Charge.
Supply & Fix bell push piano type one way 240 volt including dismantling taking down unsv one complete all as specified and as directed by Engineer in Charge.
Supply & Fix socket flush type 6 Amps, 5 pin, 230v including dismantling, taking down unsv one complete all as specified and as directed by Engineer in Charge.
Supply & Fix switch socket combination multipurpose 2-in-1 flush type, 3 pin, 6 amps, 230v including dismantling, taking down unsv one complete all as specified and as directed by Engineer in Charge.
Supply & Fix switch socket combination multipurpose 2-in-1 flush type, 3 pin 16 amps and 3 pin 6 amps, 230v including dismantling, taking down unsv one complete all as specified and as directed by Engineer in Charge.
Supply & Fix lamp Holder insulated body with back plate for batten fitting including dismantling, taking down unsv one complete all as specified and as directed by Engineer in Charge.
Supply & Fix LED lamp 12 watt, CDL, B-22 cap, (Pin type), 230V, PF-0.95 (min) including dismantling, taking out unsv CFL complete all as specified and as directed by Engineer in Charge.
Supply & Fix Ceiling rose surface Bakelite, three terminal including dismantling, taking down unsv complete all as specified and as directed by Engineer in Charge.
Supply & Fix Call bell electric, ding dong, AC 240 volt, 50 HZ. including dismantling, taking down unsv one complete all as specified and as directed by Engineer in Charge.
Supply & Fix flush type electronic fan regulator with 5 step type,120 W, AC 240 Volts, 50 Hz including dismantling, taking down unsv one complete all as specified and as directed by Engineer in Charge.
Supply & Fix MCB, Single Pole, 6 to 32 amps, 240 Volts, 10 KA breaking cap, ‘’C” curve including dismantling, taking down unsv one complete all as specified and directed by Engineer in Charge. Cat Part No- 4085-87 to 4085-95 of Legrand or equivalent from list of make as approved by GE.
Supply & Fix MCB, Double Pole, 6 to 32 amps, 415 Volts, 10 KA breaking cap, ‘’C” curve including dismantling, taking down unsv one all as specified and directed by Engineer in Charge. Cat Part No- 4086-28 to 4086-36 of Legrand or equivalent from list of make as approved by GE.
Supply & Fix MCB, Four Pole, 40 to 63 amps, 415 Volts including dismantling, taking down unsv one complete all as specified and directed by Engineer in Charge. Cat Part No- 4087-00 to 4087-02 of Legrand or equivalent from list of make as approved by GE.
Supply & Fix MCB distribution board, Double door, metal enclosure, SPN, 230 Volts, 4 way including dismantling, taking down unsv one complete all as specified and directed by Engineer in Charge.
Supply & Fix MCB distribution board, Double door, metal enclosure, SPN, 230 Volts, 8 way including dismantling, taking down unsv one complete all as specified and directed by Engineer in Charge.
Supply & Fix MCB distribution board, Double door, metal enclosure, SPN, 230 Volts, 12 way including dismantling, taking down unsv one complete all as specified and directed by Engineer in Charge.
Supply & Fix MCB distribution board, Double door, metal enclosure, TPN, 415 Volts, 4 way including dismantling, taking down unsv one complete all as specified and directed by Engineer in Charge.
Supply & Fix Metal plug and socket board with MCB SP 20 Amp, 16 KA including dismantling, taking down unsv one complete all as specified nad as directed by Engineer in Charge. Make:- Legrand, Cat No:- 5078 11 or Equivalent from list of make as approved by GE.
Supply & Fix PVC rectangular switch board of size 300mmx 250mm x50mm including necessary cutting slots for mounting switch sockets etc including dismantling, taking down unsv one complete all as specified and directed by Engineer in Charge.
Supply & Fix PVC rectangular switch board of size 200mmx 150mm x50mm including necessary cutting slots for mounting switch sockets etc including dismantling, taking down unsv one complete all as specified and directed by Engineer in Charge.
Supply & Fix PVC rectangular switch board of size 175mmx 100mm x50mm including necessary cutting slots for mounting switch sockets etc including dismantling, taking down unsv one complete all as specified and directed by Engineer in Charge.
Supply & Fix PVC rectangular switch board of size 100mmx 100mm x50mm including necessary cutting slots for mounting switch sockets etc including dismantling, taking down unsv one complete all as specified and directed by Engineer in Charge.
Supply & Fix Hylam Sheet 3mm thick on existing concealled MS/CI ractangular or Square or round box with 04 nos cadmium coated screws and cup washer including cutting slots for mounting switch/socket/fan regulator/ batten holder etc including dismantling, taking down unsv one complete all as specified and as directed by Engineer in Charge.
Supply & Fix Round shaped surface/ recess mounted LED Flat panel down lighter, 12 Watt (8" dia), PDC Aluminium housing and PMMA difuser suitable for surface/ POP celing complete with all fixing accessories and including connecting up to ceiling rose with 0.5 sqmm two core copper flexible conductor cable including dismantling, taking down unsv fitting of any type complete all as specified and directed by Engineer in Charge. Make-crompton, Cat part no. LCDSPLN-R-12-CDL or equivalent from list of make as approved by GE.
Supply & Fix square shaped surface/ recess mounted LED slim Flat panel, suitable for fixing in Aluminium framed ceiling, 36 Watt, 2'X2' size, complete with all fixing accessories and including connecting up to ceiling rose with 0.5 sqmm two core copper flexible conductor cable including dismantling, taking down unsv fitting any type complete all as specified and directed by Engineer in Charge. Make-crompton, cat part no.LCPL-36-CDL (2X2) (Aura) or equivalent from list of make as approved by GE.
S&F LED batten tube type, 2'long, 09/10 watt,CDL 230 Volts, complete with all accssories internally pre wired and including connecting up to ceiling rose with 0.5 sqmm two core copper flexible conductor cable with mounting casing box 2 nos including dismantling, taking down unsv fitting any type complete all as specified and directed by Engineer in Charge.
Supply & Fix LED tube light fitting, 36 watt, CDL, integrated LED batten, 230 Volts, 4 feet long, complete with all accessories internally pre wired and including connecting upto ceiling rose with 0.5 sqmm twin core copper flexible conductorcable including LED lamp and mounting casing box 2 nos, including dismantling, taking down unsv fittings any type complete all as specified and as directed by Engineer in Charge.
Supply & Fix LED tube light fitting, 18 watt, CDL, durable LED batten with decorative end caps, 230 Volts, 4 feet long, complete with all accessories internally pre wired and including connecting upto ceiling rose with 0.5 sqmm twin core copper flexible conductorcable including LED lamp and mounting casing box 2 nos, including dismantling, taking down unsv fittings any type complete all as specified and as directed by Engineer in Charge.
S&F LED batten suitable for 1 X 18/20 watts LED tube rod with decorative end caps, white powder coated CRCA body 230Volts, 4 feet long, complete with all accessories internally prewired and including connecting upto ceiling rose with 0.5 sqmm twin core copper flexible conductor cable including LED Lamp and mounting casing box 2 nos including dismantling, taking down unsv fittings complete all as specified and as directed by Engineer in Charge.
S&F LED tube 18/20 watt to LED batten surface mounted rewiring with 0.5 sqmm copper flexible conductor FRLSH to holder and including connecting upto ceiling rose with 0.5 sqmm two core flexible copper cable complete all as specified and as directed by Engineer in Charge.
Supply & Fix LED building security light 25 watt, 230V with lens complete with all accessories and including connecting up to ceiling rose with 0.5 sqmm three core copper flexible conductor cable, One GI medium grade 20 mm dia bracket of total length 50 cm and fixed to wall with 2 Nos MS Clamp and fastener including dismantling, taking down unsv fitting any type complete all as specified and directed by Engineer in Charge.
Supply & Fix Square shaped recess mounted LED Slim flat panel suitable for fixing in aluminium framed ceiling, 36 watt, 2' X 2' size, completewith all accessories and including connecting upto ceiling rose with 0.5 sqmm two core copper flexible conductor cable including dismantling, taking down unsv fittings of any type complete all as specified and as directed by Engineer in Charge.
Supply & Fix LED post top lantern fitting 20 watts complete all as specified and directed by Engineer in Charge.
Supply & Fix LED flood light fitting 50 Wattt complete all as specified and as directed by Engineer in Charge. Make:- Surya, Model:-Lumos Max Model SLE FL 50 or Equivalent from list of make as approved by GE.
Supply & Fix LED flood light fitting 100 Wattt complete all as specified and as directed by Engineer in Charge. Make:- Surya, Model:-Lumos Max Model SLE FL 100 or Equivalent from list of make as approved by GE.
REPAIR TO CEILING FANS WITH FOLLOWING ITEMS OF WORK :- Material & Labour for Rewinding of Ceiling fan 1200/1400 mm sweep after dismantling complete motor assembly, bearings, bushings, removal of burnt copper wire, cleaning of core, inserting proper insulating paper in slots, winding with and as per existing size/turn of super enamelled copper wire, heating, varnishing, replacement of unsv bearings / bushings, assemble of rotor and stator unit with capacitor, connecting wire, down rod, blades and testing complete all as specified and as directed by Engineer in Charge.
Note for Item no 48:- (i) Contractor shall collect fans from the complaint cells of specified area and bring back to complaint cell after repair. Cost of transportation is deemed to be inclusive in the quoted rate. (ii) Spares that shall be replaced such as bearing, Bushing, Capacitor shall be measured and paid separately as supply & Fixing only under relevant item of this schedule. (iii) Cost of Connector block and capacitor holder is deemed to be inclusive in the quoted rate.
All as per item No- 48 here-in-above but for Exhaust fan 250/300 mm sweep industrial type.
Supply & Fix ball bearing No 6201/6202/6203/6204 of SKF/Tata/NBC complete all as specified and as directed by Engineer in Charge.
Supply & Fix G.M. Bush bearing for ceiling fan as per existing pattern complete all as specified and as directed by Engineer in Charge.
Supply & Fix Capacitor AC for 230 volts 50 Hz of capacity 1.2/2.0 Mfd complete all as specified and as directed by Engineer in Charge.
Supply & Fix capacitor AC for 230 volts 50 Hz of capacity 3.15 Mfd complete all as specified and as directed by Engineer in Charge.
Supply & Fix capacitor AC for 230 volts 50 Hz of capacity 4.0 Mfd complete all as specified and as directed by Engineer in Charge.
Material & Labour for Painting of Ceiling fan 1200/1400 mm including scrapping, cleaning and removing dust from the blade and body and applying two coat of synthetic enamel paint over one coat of primer complete all as specified and as directed by Engr-in-charge.
Supply & Fix in repair of exhaust fan 200/225 mm, PVC body with louvres, 230 Volts including dismantling, taking down unsv fitting any type complete all as specified and directed by Engineer in Charge.
Supply & Fix in repair of exhaust fan 250/300 mm, PVC body with louvres, 230 Volts including dismantling, taking down unsv fitting any type complete all as specified and directed by Engineer in Charge.
Supply & Fix PVC insulated PVC sheathed copper flexible wire, multistrand 4sqmm 3 core, ISI marked complete all as specified and as directed by Engineer in Charge.
Supply & Fix in repair fusible plug marked suitable for 25 and 50 ltrs capacity Geysers complete all as specified and directed by Engineer in Charge.
Supply & Fix in repair thermostat ISI marked suitable for geysers 25 Ltrs to 50 Ltrs Capacity complete all as specified and as directed by Engineer in Charge. Make- Bajaj/Venus/Recold as approved by GE.
Supply & Fix in repair heating element Marked round/ triangular bas, push type or thread type including rubber washers for 1.5/2.0 KW complete all as specified and directed by Engineer in Charge.
Supply & Fix in repair inner water container made of SS, vertical or horizontal type for 25/50 ltr capacity geyser complete all as specified and directed by Engineer in Charge.
Supply & Fix in repair of aparatus plate suitable for vertical/ horizontal type Geyser 25 or 50 ltr capacity complete all as specified and directed by Engineer in Charge.
Supply & Fix in repair heavy duty copper connections pipe with brass hexagonal adopters at both side 15mm dia and 450mm long for hot water complete all as specified and as directed by Engineer in Charge.
Supply & Fix in repair heavy duty PVC connections pipe with brass hexagonal adoptersat both side 15mm dia and 450mm long for hot /cold water complete all as specified and directed by Engineer in Charge.
Material and Labour for Earthing Complete with galvanised steel pipe electrode, 40 mm bore, medium grade, 6 meter long buried directly and vertically in ground with top edge at ground levelafter making bore hole of size not less than 300mm dia and 6.0 mtr long using suitable mechanical drilling rig (for drilling near the specified building), connected with galvanized steel earthing lead of 4mm dia all as shown in Plate No-2, connected to the earthing test point, concrete pit in PCC 1:3:6 Type C2 with RCC Precast Pit Cover slab 400mm X 400mm X 80mm with handle for lifting made out of 8mm dia MS Rod, funnel, wiremesh, 15mm dia light grade GI Tubing for protection of GI wire 4mm dia, charcoal and salt in alternate 150mm thick layers around GI earth pipe, including necessary returning filling in & removal complete all as specified or indicated in SSR Part-I, including testing to achieve earth resistance value as per IS specification on completion complete all as specified and as directed by Engineer in Charge.
Material & Labour for periodical servicing / Repair, maintenance of split type air conditioner 1.5/2.0 ton cap in situ by cleaning of complete outdoor unit and indoor unit, air blower units, air filter, grills with required chemical solution and using forced air blower or vacuum cleaner, complete checking serviceability of electrical circuit of outdoor and indoor unit, electronic circuit, airblower unit, condenser, remote control unit, including replacement of unserviceable spares such as relays, capacitors, wiring kit, screws, nuts, bolts & washers, remote control unit and testing after completion to entire satisfaction of Engr-in-Charge. Note :- (i) Spares required shall be measured and paid under respective item of this schedule as supply and fix. (ii) Screws, nuts, bolts & washers shall be inclusive of quoted rate and no extra measurement shall be made. Make of AC- Blue Star, LG, Hitachi, Voltas & Samsung.
Material & Labour for periodical servicing/ Repair,maintenance of window type air conditioner 1.5/2.0 ton cap in situ by cleaning of complete cooling coil, condenser unit, air blower units, air filter, grills with required chemical solution and using forced air blower or vaccuum cleaner, complete checking serviceability of electrical circuit of unit, airblower unit, condenser, cooling coil, thermostat, copper tubings, including replacement of unserviceable spares such as relays, capacitors, thermostat, wiring kit, screws, nuts, bolts & washers,and testing after completion to entire satisfaction of Engr-in-Charge. Note: (i) Spares required shall be measured and paid under respective item of this schedule as supply and fix. (ii) Screws, nuts, bolts & washers shall be inclusive of quoted rate and no extra measurement shall be made. Make of AC- Blue Star, Voltas, Feeder Lloyed, Shriram Usha & Carrier.
Supply Only following company recommended spares of Split/Window type air conditioner of 1.5 /2.0 Ton cap suitable for AC Make-Blue Star, LG, Hitachi, Voltas & Samsung, Shriram Usha, Feeder Lloyed & Carrier whichever applicable complete all as specfied and as directed by Engineer in Charge.
Running capacitor 45 to 60 mfd
Starting capacitor 120-150mfd / 150-200 mfd
Starting relay suitable for reciprocating compressor
hermostat switch for window type AC
Conderser fan blade for window type AC made of plastic/aluminium as required at site.
Conderser fan blade for split type AC made of plastic/aluminium as required at site
Remote control unit as per original make complete with 2 Nos Duracell battery
Air filter suitable for indoor unit of split type AC 1.5 /2.0 tr capacity as per existing make and model.
Air filter suitable for window type AC 1.5 /2.0 tr capacity as per existing make and model.
Flexible PVC drain pipe 15/20mm bore
Supply & fix new hermetically sealed rotary compressor unit suitable for split type AC with required nuts, bolts & washers, connecting necessary copper tubings, replacement of capilary tube and drier filter after dismentling/taking out existing unserviceable/burnt compressor unit from the split type airconditioner 1.5 ton cap in situ and and testing after completion to entire satisfaction of Engr-in-Charge, suitable for AC make-Blue Star, LG, Hitachi, Voltas & Samsung whichever applicable. Note: (i) Compressor unit shall be 1st quality with compitable model and make of compressor shall be as recommended by the manufacturer of AC. (ii) Gas charging shall be measured and paid separately under appropriate item of this schedule.
Supply & fix new hermetically sealed rotary compressor unit suitable for split type AC with required nuts, bolts & washers, connecting necessary copper tubings, replacement of capilary tube and drier filter after dismentling/taking out existing unserviceable/burnt compressor unit from the split type airconditioner 2.0 ton cap in situ and and testing after completion to entire satisfaction of Engr-in-Charge, suitable for AC make-Blue Star, LG, Hitachi, Voltas & Samsung whichever applicable. Note: (i) Compressor unit shall be 1st quality with compitable model and make of compressor shall be as recommended by the manufacturer of AC. (ii) Gas charging shall be measured and paid separately under appropriate item of this schedule.
Supply & fix new Hermatically sealed reciprocating compressor unit suitable for Window type AC with required nuts, bolts & washers, connecting necessary copper tubings , replacement of capilary tube and oil filter after dismantling/taking out existing unserviceable/burnt compressor unit from the window type airconditioner 1.5 ton cap in situ and and testing after completion to entire satisfaction of Engr-in-Charge, suitable for AC Make/ model of-Blue Star, Voltas, Feeder Lloyed, Shriram Usha & Carrier whichever applicable. Note: (i) Compressor unit shall be 1st quality with compitable model and make of compressor shall be as recommended by the manufacturer of AC. (ii) Gas charging shall be measured and paid separately under appropriate item of this schedule.
Supply & fix new Hermatically sealed reciprocating compressor unit suitable for Window type AC with required nuts, bolts & washers, connecting necessary copper tubings, replacement of capilary tube and oil filter after dismentling/taking out existing unserviceable/burnt compressor unit from the window type airconditioner 2.0 ton cap in situ and testing after completion to entire satisfaction of Engr-in-Charge, suitable for AC Make/ model of-Blue Star, Voltas, Feeder Lloyed, Shriram Usha & Carrier whichever applicable. Note: (i) Compressor unit shall be 1st quality with compitable model and make of compressor shall be as recommended by the manufacturer of AC. (ii) Gas charging shall be measured and paid separately under appropriate item of this schedule.
Supply & fix new blower motor with required nuts, bolts & washers, connecting necessary wires, fixing of fan complete after dismentling/taking out existing unserviceable/burnt blower motor unit from the window type airconditioner 1.5/2.0 ton cap in situ suitable for window AC Make/ model of Blue Star, Voltas, Feeder Lloyed, Shriram Usha & Carrier whichever applicable and testing after completion to entire satisfaction of Engr-in-Charge.
Supply & fix new blower motor, 230V, RPM-950-1350 with required nuts, bolts & washers, connecting necessary wires, fixing of fan complete after dismentling/taking out existing unserviceable/burnt blower motor unit from the outdoor unit of split type air conditioner 1.5/2.0 ton cap in situ suitable for Split AC make-Blue Star, LG, Hitachi, Voltas & Samsung whichever applicable and testing after completion to entire satisfaction of Engr-in-Charge.
Supply and fix electronic circuit board (PCB) suitable for 1.5/2.0 ton window type AC as per existing one after dismentling taking out unsv PCB and testing complete suitable for AC make/model of Blue Star, LG, Hitachi, Voltas & Samsung whichever applicable. Note: (i) PCB unit shall be compitable model and make as recommended by the manufacturer of AC.
Supply and fix electronic circuit board (PCB) suitable for 1.5/2.0 ton split AC as per existing one after dismentling taking out unsv PCB and testing complete suitable for AC make/model of Blue Star, LG, Hitachi, Voltas & Samsung whichever applicable. Note: (i) PCB unit shall be compitable model and make as recommended by the manufacturer of AC.
Supply and fix condenser coil unit of window type AC of cap 1.5 ton cap in situ as per existing make and competable model, connecting necessary copper tubings by brazing after dismentling/taking out existing unserviceable condenser unit suitable for AC Make/model of Blue Star, Voltas, Feeder Lloyed, Shriram Usha & Carrier whichever applicable and testing after completion to entire satisfaction of Engr-in-Charge. Note: Gas charging shall be measured and paid separately under appropriate item of this schedule.
Supply and fix condenser coil unit of window type AC of cap 2.0 ton cap in situ as per existing make and competable model, connecting necessary copper tubings by brazing after dismentling/taking out existing unserviceable condenser unit suitable for AC Make/model of Blue Star, Voltas, Feeder Lloyed, Shriram Usha & Carrier whichever applicable and testing after completion to entire satisfaction of Engr-in-Charge. Note: Gas charging shall be measured and paid separately under appropriate item of this schedule.
Supply and fix cooling coil unit of window type AC of cap 1.5/2.0 ton cap in situ as per existing make and competable model, connecting necessary copper tubings by gas welding, gas charging with R-22 after dismentling/taking out existing unserviceable coling coil unit suitable for AC Make-Blue Star, Voltas, Feeder Lloyed, Shriram Usha & Carrier whichever applicable and testing after completion to entire satisfaction of Engr-in-Charge and user unit. Note: Gas charging shall be measured and paid separately under appropriate item of this schedule.
Supply and fix outdoor unit of split type AC of cap 1.5 ton cap in situ as per existing make and compatible model without compressor but including blower motor, fan connecting necessary copper tubings by brazing after dismentling/taking out existing unserviceable outdoor unit and testing after completion to entire satisfaction of Engr-in-Charge. Note: (i) Gas charging shall be measured and paid separately under appropriate item of this schedule. (ii) Compressor unit shall be measured and paid separately under appropriate item of this schedule.
Supply and fix outdoor unit of split type AC of cap 2.0 ton cap in situ as per existing make and compatible model without compressor but including blower motor, fan connecting necessary copper tubings by brazing after dismentling/taking out existing unserviceable outdoor unit and testing after completion to entire satisfaction of Engr-in-Charge. Note: (i) Gas charging shall be measured and paid separately under appropriate item of this schedule. (ii) Compressor unit shall be measured and paid separately under appropriate item of this schedule.
Supply and fix indoor unit of split type AC of cap 1.5 ton cap complete with cooling unit, PCB, Blower unit with motor, swing motor, remote unit in situ as per existing make and compatible model complete, connecting electrically and copper tubings by brazing, after dismentling/taking out existing unserviceable indoor unit suitable for AC make/model of Blue Star, LG, Hitachi, Voltas & Samsung whichever applicable and testing after completion to entire satisfaction of Engr-in-Charge . Note: (i) Gas charging shall be measured and paid separately under appropriate item of this schedule.
Supply and fix indoor unit of split type AC of cap 2.0 ton cap complete with cooling unit, PCB, Blower unit with motor, swing motor, remote unit in situ as per existing make and compatible model complete, connecting electrically and copper tubings by brazing, after dismentling/taking out existing unserviceable indoor unit suitable for AC make/model of Blue Star, LG, Hitachi, Voltas & Samsung whichever applicable and testing after completion to entire satisfaction of Engr-in-Charge . Note: (i) Gas charging shall be measured and paid separately under appropriate item of this schedule.
Supply and fix louvers swing motor suitable for window type AC of cap 1.5/2.0 ton cap in situ as per existing make and compatible model, necessary electrical connection and conection with louvers, after dismentling/taking out existing unserviceable unit suitable for AC Make-Blue Star, Voltas, Feeder Lloyed, Shriram Usha & Carrier whichever applicable and testing after completion to entire satisfaction of Engr-in-Charge and user unit.
Supply and fix louvers swing motor suitable for indoor unit of split type AC of cap 1.5/2.0 ton cap in situ as per existing make and compatible model, necessary electrical connection after dismentling/taking out existing unserviceable unit suitable for AC make-Blue Star, LG, Hitachi, Voltas & Samsung whichever applicable and testing after completion to entire satisfaction of Engr-in-Charge and user unit.
Material & Labour for servicing/Repair,maintenance of water cooler of cooling capacity 40/60/80/120 LPH any storage capacity in situ by cleaning of complete cooling coil, condenser unit, air blower units, grills, external body surface, internal body surface with required chemical solution and using forced air blower or vaccuum cleaner, cleaning water storage tank, checking serviceability of electrical circuit of unit, airblower unit, condenser, cooling coil, thermostat, copper tubings, operating knobs, push cocks, drain trays, drain pipes, float valves, relays, OL protector including replacement of unserviceable spares such as relays, OL protector, capacitors, thermostat, wiring kit, operating knobs, push cocks, float valves, Screws, nuts, bolts & washers of water cooler make-Bluestar or Voltas or Usha and testing after completion to entire satisfaction of Engr-in-Charge . Note: (i)Spares required shall be measured and paid under respective item of this schedule as supply and fix. (ii) Screws, nuts, bolts & washers, gaskets shall be inclusive of quoted rate and no extra measurement shall be made.
Supply and fix following company recommended spares of water cooler of cap 40/60/80/120 LPH suitable for make- Usha, Voltas, Blue Star whichever applicable complete all as specified nad as directed by Engineer in Charge.
Over load protector (OLP)
Starting relay
Thermostat
Starting capacitor 40/60 mfd
Starting capacitor 80-100 mfd
Running capacitor 4 to 25 mfd
Drain Hose pipe 20mm to 30mm dia PVC
CP push cock 15 mm dia
PVC float valve 15mm dia
PVC/aluminium fan blade for condenser blower motor
Supply & fix new company sealed reciprocating compressor unit with required nuts, bolts & washers, connecting necessary copper tubings by brazing, replacement of capilary tube and oil filter after dismentling/taking out existing unserviceable/burnt compressor unit from the water cooler 40LPH/80L (cooling/Storage) capacity in situ and and testing after completion to entire satisfaction of Engr-in-Charge,suitable for WC Make-Usha, Voltas & Blue Star whichever applicable. Note: (i) Compressor unit shall be 1st quality with compitable model and make of compressor shall be as recommended by the manufacturer of WC. (ii) Gas charging shall be measured and paid separately under appropriate item of this schedule.
Supply & fix new company sealed reciprocating compressor unit with required nuts, bolts & washers, connecting necessary copper tubings by brazing, replacement of capilary tube and oil filter after dismentling/taking out existing unserviceable/burnt compressor unit from the water cooler 80LPH/120,or 120LPH/150 (cooling/Storage) capacity in situ and and testing after completion to entire satisfaction of Engr-in-Charge,suitable for WC Make-Usha, Voltas & Blue Star whichever applicable. Note: (i) Compressor unit shall be 1st quality with compitable model and make of compressor shall be as recommended by the manufacturer of WC. (ii) Gas charging shall be measured and paid separately under appropriate item of this schedule.
Supply and fix condenser coil unit of water cooler 40/80Ltrs or 80/120Ltrs cap as per existing make and competable model, connecting necessary copper tubings by brazing after dismentling/taking out existing unserviceable condenser unit and testing after completion to entire satisfaction of Engr-in-Charge suitable for WC Make-Usha, Voltas or Blue Star whichever applicable. Note: (i) Gas charging shall be measured and paid separately under appropriate item of this schedule. (ii) Make of item shall be as recommended by the manufacturer of WC
Supply and fix condenser coil unit of water cooler 120/150 Ltrs cap as per existing make and competable model, connecting necessary copper tubings by brazing after dismentling/taking out existing unserviceable condenser unit and testing after completion to entire satisfaction of Engr-in-Charge suitable for WC Make-Usha, Voltas or Blue Star whichever applicable. Note: (i) Gas charging shall be measured and paid separately under appropriate item of this schedule. (ii) Make of item shall be as recommended by the manufacturer of WC
Supply & fix new condenser fan motor with required nuts, bolts & washers, connecting necessary wires, fixing of fan complete after dismentling/taking out existing unserviceable/burnt fan motor unit from the water cooler of cooling cap 40/80L to 120/150L in situ and and testing after completion to entire satisfaction of Engr-in-Charge and user unit suitable for WC Make-Usha, Voltas or Blue Star whichever applicable. Note: Make of item shall be as recommended by the manufacturer of WC
Supply and fix drain tray made stain less steel with required nuts, bolts or screws suitable for any cap incl dismentling taking out unserviceable one suitable for WC Make-Usha, Voltas or Blue Star whichever applicable. Note: Make & size of item shall be as recommended by the manufacturer of WC
Supply & Fix Base frame as per sample suitable for 40/80 Ltrs water cooler made out of MS angle iron, flats, cut to required length, making necessary shape, screw holes, fixing with necessry electric welding, painting with one coat of red oxide and two coats of synthetic enamel paint at all side of the steel member.
Supply & Fix Base frame as per sample suitable for 80/120 Ltrs,120/150 ltrs water coolers made out of MS angle iron, flats, cut to required length, making necessary shape, screw holes, fixing with necessry electric welding, painting with one coat of red oxide and two coats of synthetic enamel paint at all side of the steel member.
Supply and fix following company recommended spares as per make of desert cooler as mensioned.
Wiring kit
PVC float valve 15mm dia
Natural grass pad (set of 3)
Blower motor of suitable capacity including necessary electric connection, mounting nuts, bolts & washers
PVC fan blade for blower motor
Water spray pump
PVC flexible pipe 6mm to 10mm dia
Material & Labour for Repair /maintenance of Refrigerator of any capacity in situ by cleaning of complete external surface, internal surface, trays, racks with required chemical solution removing all dirt, strains complete checking serviceability of electrical circuit of unit, thermostat knob, fans if provided in frost free model, relays, thermostat, trays including replacement of unserviceable spares such as relays, thermostat and testing after completion to entire satisfaction of Engr-in-Charge. make of Refrigerator-Godrej/Whirlpool/Videocon/LG. Note: (i) Spares required shall be measured and paid under respective item of this schedule as supply and fix. (ii) Screws, nuts, bolts & washers shall be inclusive of quoted rate and no extra measurement shall be made.
Supply only following company recommended spares of refrigerator any cap after dismentling taking out unsv one for make of refrigerator -Godrej/Whirlpool/Videocon/LG whichever applicable complete all as specified nad as directed by Engineer in Charge.
Starting relay
Thermostat
Supply & fix new company sealed reciprocating compressor unit for refrigerator make-Godrej/Whirlpool/Videocon/LG whicever applicable of capacity 165 ltr to 310 ltr with required nuts, bolts & washers, connecting necessary copper tubings by gas welding/brazing, gas charging with R-134A after dismentling/taking out existing unserviceable/burnt compressor unit from the refrigerator in wksp and and testing after completion to entire satisfaction of Engr-in-Charge and user unit. Note: (i) Compressor unit shall be 1st quality with compitable model and make of compressor shall be as recommended by the manufacturer of Refrigerator. (ii) Gas charging shall be measured and paid separately under appropriate item of this schedule.
Supply & fix new condenser unit for refrigerator make-Godrej/Whirlpool/Videocon/LG whicever applicable of capacity 165 ltr to 310 ltr with required nuts, bolts & washers, connecting necessary copper tubings by gas welding/brazing, gas charging with R-134A after dismentling/taking out existing unserviceable unit from the refrigerator in situ and and testing after completion to entire satisfaction of Engr-in-Charge and user unit. Note: (i) Condenser unit shall be compitable model and make shall be as recommended by the manufacturer of Refrigerator. (ii) Gas charging shall be measured and paid separately under appropriate item of this schedule.
Material & Labour for servicing/maintenance of Deep Freezer of capacity 300L/310L/450L make-Honeydew/Voltas in situ by cleaning of complete external surface, internal surface, trays, racks with required chemical solution removing all dirt, strains complete and checking serviceability of electrical circuit of unit, condenser unit, relays, thermostat, trays including replacement of unserviceable spares such as relays, capacitors, thermostat, trays and testing after completion to entire satisfaction of Engr-in-Charge as well as user unit. Note: (i)Spares required shall be measured and paid under respective item of this schedule as supply and fix. (ii) Screws, nuts, bolts & washers shall be inclusive of quoted rate and no extra measurement shall be made.
Supply and fix following company recommended spares of Deep freezer of cap 300/310/450 Ltr suitable for make- Honeydew or Voltas whichever applicable complete all as specified nad as directed by Engineer in Charge.
Over load protector
Starting relay
Thermostat
Starting capacitor 40/60 mfd
Starting capacitor 80-100 mfd
Running capacitor 4 to 25 mfd
Sliding trays small as per existing make & model
Sliding trays large as per existing make & model
PVC fan blade for blower motor
Supply & fix new company sealed reciprocating compressor unit with required nuts, bolts & washers, connecting necessary copper tubings bybrazing, replacement of capilary tube and oil filter after dismentling/taking out existing unserviceable/burnt compressor unit from the Deep freezer 300/310/450L capacity and and testing after completion to entire satisfaction of Engr-in-Charge. Make-Honeydew/Voltas whichever applicable. Note: (i) Compressor unit shall be 1st quality with compitable model and make of compressor shall be as recommended by the manufacturer of DF. (ii) Gas charging shall be measured and paid separately under appropriate item of this schedule.
Supply and fix condenser coil unit of Deep freezer 300/310/450 L as per existing make and competable model, connecting necessary copper tubings by gas welding, gas charging with R-22 after dismentling/taking out existing unserviceable condenser unit and testing after completion to entire satisfaction of Engr-in-Charge and user unit suitable for DF Make-Honeydew/Voltas whichever applicable. Note: (i) Gas charging shall be measured and paid separately under appropriate item of this schedule. (ii) Make of item shall be as recommended by the manufacturer of WC
Supply & fix new blower motor with required nuts, bolts & washers, connecting necessary wires, fixing of fan complete after dismentling/taking out existing unserviceable/burnt blower motor unit from the Deep freezer of cap 300/310/450L and and testing after completion to entire satisfaction of Engr-in-Charge and user unit suitable for DF Make-Honewdew/ Voltas whichever applicable. Note: Make of item shall be as recommended by the manufacturer of WC
Material & Labour for refrigerant gas charging for split type AC with R-22 gas after proper cleaning of pipe lines with carbon tetra chloride and flushing out,leak testing by charging Nitrogen, including replacement of liquide line filter, capillary tube, required soldering/brazing to attain proper cooling level to entire satisfaction of Engr-in-Charge for 1.5 Tr/2.0 Tr Split AC Unit.
Material & Labour for refrigerant gas charging for window type AC with R-22 gas after proper cleaning of pipe lines with carbon tetra chloride and flushing out,leak testing by charging Nitrogen including replacement of liquide line filter, capillary tube, required soldering/brazing to attain proper cooling level to entire satisfaction of Engr-in-Charge for 1.5 TR/2.0 TR window type AC Unit.
Material & Labour for refrigerant gas charging for water cooler with R-22 gas after proper cleaning of pipe lines with carbon tetra chloride and flushing out by charging Nitrogen, including replacement of liquide line filter, capillary tube, required soldering/brazing to attain proper cooling level to entire satisfaction of Engr-in-Charge for 40/80 to 120/150 L water cooler Unit.
Material & Labour for refrigerant gas charging for Deep freezer with R-22 gas after proper cleaning of pipe lines with carbon tetra chloride and flushing out, leak testing by charging Nitrogen including replacement of liquide line filter, capillary tube, required soldering/brazing to attain proper cooling level to entire satisfaction of Engr-in-Charge for 300/310/450L deep freezer Unit.
Material & Labour for refrigerant gas charging for Refrigerator with R-134A gas after proper cleaning of pipe lines with carbon tetra chloride and flushing out,leakage testing by charging Nitrogen including replacement of liquide line filter, capillary tube, required soldering/brazing to attain proper cooling level to entire satisfaction of Engr-in-Charge for 165 L to 310 L Refrigerator Unit.
Material & Labour for Painting of water cooler body by two coats of paint Externally of any capacity by spray painting after preparation of surface with existing colour
Material & Labour for Painting of outdoor unit of split A/C externally by two coat of paint of any capacity by spray painting after preparation of surface with existing colour
Material & Labour for Numbering of cooling appliances( window/split A/c's,w/coolers,Deep freezers, Fridge etc in situ up to 10 met installed Height with the help of ladder etc ) with white colour in black back ground up to 10 cm width and height all as directed by the Engr-In-Charge.
Material & Labour for dismantling unsv voltage stabiliser for repair including replacement of relays, electronic voltage sensor, circuit and meter, micro switch, indicating light, RC filter, and other connected items for making functional and rewinding of transformer unit with suitable size of super enamelled coper wire, heating, vernishing and testing after repair complete for capacity 1 KVA to 2 KVA.
Material & Labour for dismantling unsv voltage stabiliser for repair including replacement of relays, electronic voltage sensor, circuit and meter, micro switch, indicating light, RC filter, and other connected items for making functional and rewinding of transformer unit with suitable size of super enamelled coper wire, heating, vernishing and testing after repair complete for capacity 3 KVA to 5 KVA.
AMAN ENGINEERING AND ELECTRICAL WORKS
Green Ray Enterprises
metro electrical services
Sahara Engineers
BRILLIANT AIRCONDITIONING AND REFRIGERATION WORKS
M/S. Niksun Electro-Infra Private Limited
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .