Loading…
Loading…
Tender Value
₹110.4 Cr
EMD Value
₹2.2 Cr
Closing Date
9 Sept 2026, 3:00 pm
Design, supply, erection, testing and commissioning for OHE upgradation from existing 1x25kV system to 2x25kV AT feeding system with feeder and earthing works in Pagidipalli(PGDP)(incl)-Vishnupuram(VNUP)(incl)-Motumari(MTMI)(incl) of Secunderabad division under South Central Railway. Total 223 RKM/223 TKM
2x25kV-OHE-PGDP-VNUP-MTMI
2x25kV-OHE-PGDP-VNUP-MTMI
Open
Works - General
24 Months
Hyderabad, Telangana
₹0
₹2.2 Cr
24 Jul 2026
24 Jul 2026
26 Aug 2026
17 Aug 2026
A1-OHE & PSI items for 2x25kV works 278244837.00 Below/P
E1 -Non-SOR(Additional items for 2x25kV) 16390003.08 Below/P
Item Breakup - A1-OHE & PSI items for 2x25kV works
Per Track Erection KM 1(c):Preparation of Traction Working Rule Diagram along with Working Instructions
Each 1(d):Supply and Installation of Traction Working Rule Diagram Boards
Square Supply & erection Foot 1(f):Preparation and Designing of Sectioning Diagram for station
Each 3(a):Erection of Traction Masts, Feeder Masts, AT Mast and Main Masts of Switching Stations.
1836.00 Block 3(b):Erection of TTCs, Portals and Small Parts Steel (SPS)
1161.00 Block 3(e):Supply and Erection of Guy Rod Assembly
Each 3(g):Supply of Steel Reinforcement for RCC Work
MT 4(a)(i):Supply (without Insulators) and Erection of Single Cantilever Assembly for Conventional OHE
3568.00 Block 4(a)(ii):Erection of Two Cantilever Assemblies on same structure or support for Conventional OHE
669.00 Block 4(a)(iii):Erection of Three Cantilever Assemblies on same structure or support for Conventional OHE
92.00 Block 4(b)(i):Supply (without Insulators) and Erection of a Pull Off arrangement for Conventional OHE
1.00 Block 6(a):Supply and Erection of Regulated Conventional OHE SCR HQ-ELECTRICAL/SOUTH CENTRAL RLY
Per Track Supply KM
Per Track Erection KM
1.00 Block KM 7(a):Erection/Stringing of Along Feeder (either All Aluminium 25 kV Feeder (single spider) or Copper Feeder wire)
22.00 Block 7(b):Erection of Copper Cross Feeder Wire
4.00 Block 7(c):Erection of Large Span Wire (130 Sq. mm)
2608.00 Block 8(a)(xii):Marking/Painting of temperature and 'Y' - Measurement on OHE Structures at BWA locations
Each 8(b)(i):Supply (without Insulator) and Erection of materials for Termination single conductor of OHE or terminating wire
60.00 Block 8(b)(ii): Supply (without Insulator) and Erection of Materials for Termination of Conventional OHE
454.00 Block 8(b)(iii):Supply (without Insulator) and Erection of Materials for Termination of Along Feeder (Aluminium/Copper)
30.00 Block 8(b)(ix):Supply (without Insulators) and Erection of Materials for Termination of Copper Cross Feeder
4.00 Block 9(a):Supply (without Insulators) and Erection of Anti-creep with galvanized steel wire for Conventional OHE
233.00 Block SCR HQ-ELECTRICAL/SOUTH CENTRAL RLY 9(c):Supply (without Insulators) and Erection of Anti-creep with cadmium copper catenary wire for Conventional OHE in polluted area (excluding supply of cadmium copper catenary wire)
10.00 Block 10(a):Extra on item 6(a) or 6(c) for Supply and Erection of additional fittings required at a turnout, cross- over or over-lap
46.00 Block 11(a)(i):Supply (without Insulator) and Erection of 25 kV Solid Core Cut-in Insulator
713.00 Block 11(a)(ii):Supply (without Insulator) and Erection of 25 kV Solid Core Suspension Insulator
188.00 Block 11(b):Supply (without Insulator) and Erection of 25 kV Post Insulator
368.00 Block 12(a):Supply (without Insulators) and Erection of 25 kV Section Insulator Assembly for Conventional OHE
2.00 Block 13(c):Supply and Erection of Earth Contact Assembly for an Isolator
1.00 Block 13(g):Supply (without Insulators) and Erection of 25 kV Double Pole Isolator (1600 A) without earth contact assembly.
1.00 Block 14(a):Erection of PTFE Neutral Section Assembly
Each SCR HQ-ELECTRICAL/SOUTH CENTRAL RLY
1.00 Block 15(a):Supply and Erection of 50 sq.mm Copper Jumper (C-Jumper, F-Jumper, Anti-Theft Jumper) (excluding copper jumper supply)
4552.00 Block 15(b):Supply and Erection of 160 or 105 sq.mm Copper Jumper (Isolator Jumper, G-Jumper) (excluding copper jumper supply)
284.00 Block 15(c):Supply and Erection of Large copper jumper wire 160 sq. mm between Aluminium Bus and Cross- feeder (excluding copper jumper supply)
1.00 Block 15(d):Supply and Erection of Large copper jumper wire 160 sq. mm between Cross-feeder and OHE (excluding copper jumper supply)
1.00 Block 15(e):Supply and Erection of Aluminium Jumper
10.00 Block 16(a):Supply and Erection of Structure Bond
Each 16(b):Supply and Erection of Longitudinal Bond
Each 16(c):Supply and Erection of Transverse & Special Bond
Each 16(aa):Drilling of Holes on Rails
Each 16(d):Supply and Erection of Structure Bond on Platform Area
Each SCR HQ-ELECTRICAL/SOUTH CENTRAL RLY 17(a):Supply and Erection of Single Earth Electrode at COP/FOB/PTFE/Steel Girder etc
Each 17(b):Supply and Erection of Earth Bus
Metre 17(j):Supply and Erection of 8 SWG G.I wire for earthing
Metre 17(k):Supply and Erection of Earth Screen Wire
Metre 26(a)(i):Supply and Erection of Aluminium Bus Bar 36 mm x 28 mm
Metre 26(a)(ii):Supply and Erection of 18 mm Copper Bus Bar
Metre 26(b)(i):Supply and Erection of Aluminium Bus Terminal (6480)
Each 31(a):Transfer of Overhead Equipment from one Mast or Support to another, including removal of Cantilever Assembly from old Mast or Support
5182.00 Block 31(b):Provision of additional bracket assembly/assemblies on a mast or support
10.00 Block 31(c):Dismantling of Overhead Equipment
Per Track Erection KM
1.00 Block KM 31(d): Dismantling of Along Feeder Wire (Aluminium or Copper)
1.00 Block 31(e):Splicing and Extension of Anchored OHE
120.00 Block 31(f):Dismantling of Section Insulator
Each SCR HQ-ELECTRICAL/SOUTH CENTRAL RLY
2.00 Block 31(g):Slewing and Putting back of OHE in original position
Each Erection Span
1.00 Block Span 31(h): Dismantling of an Isolator
28.00 Block 31(i):Dismantling of Post Insulator
368.00 Block 31(j)(i):Dismantling of Suspension Insulator
7.00 Block 31(j)(ii):Dismantling of Cut-in Insulator
669.00 Block 31(k)(i):Dismantlement of OHE Mast or structure by cutting
190.00 Block 31(k)(ii):Dismantlement of Upright of TTC/Portal by cutting
276.00 Block 31(l)(ii):Removal of OHE Masts on Bridges
5.00 Block 31(n):Dismantling of Guy Rod
10.00 Block 31(p):Dismantling of Drop Arms/Booms/ Temporary Masts
92.00 Block 31(q):Splicing and Extension of Feeder conductor
Each 31(s): Dismantling of Fabricated Steel or Small Parts Steel (SPS)
7.00 Block 31(t)(i):Dismantling of a Regulating Equipment (Three-pulley type) with counter weight assembly for Conventional OHE SCR HQ-ELECTRICAL/SOUTH CENTRAL RLY
446.00 Block 31(t)(iii):Dismantling of Anti-creep with galvanized steel wire or cadmium catenary wire
446.00 Block 31(t)(iv):Dismantling of all types of Copper Jumpers
1653.00 Block 31(t)(v):Dismantling of Termination for Conventional type Overhead Equipment
446.00 Block 31(t)(vii):Dismantlement of Termination for Along Feeder (Aluminium or Copper)
5.00 Block 31(t)(ix):Re-adjustment of OHE Spans, including droppers
Each Erection Span
4014.00 Block Span 31(t)(x):Dismantling of Structure Bond / Longitudinal Bond / Transverse and Special Bond
Each 34(j):Providing and Laying Pitching with Stone Boulders
cum 36(a):Unloading of all types of Steel Structures
MT 36(b):Loading of all types of Steel Structures
MT 37(a):Unloading of all types of Copper & Aluminium conductors
MT 37(b):Loading of all types of Copper & Aluminium conductors
MT 38:Transportation of OHE structures / Materials / Equipments
MT-Km 40(a):Supply and Erection of Number Plate (Enamel Type)
Each 40(b):Supply and Erection of Number Plate (Retro-Reflective Type)
Each SCR HQ-ELECTRICAL/SOUTH CENTRAL RLY
Each 41(b):Supply and Erection of Enamel type Public Caution board
Each 41(c): Supply and Erection of Enamel type Staff Caution board
Each 41(d):Supply and Erection of Retro- Reflective Type Electric Engine Stop Board/Caution Unwired Turnout Board
Each 41(e):Supply and Erection of Retro- Reflective Type Power Block Working Limit Board
Each 41(f):Supply and Erection of Enamel type Caution Clearance to OHE nearby Restricted Board
Each 41(g):Supply and Erection of Retro- Reflective type Danger Board for Height Gauge
Each 41(h):Supply and Erection of Vitreous Enameled 25 kV Danger Board with skull & bones for Overline Structure (OLS) and Auxiliary Transformer
Each 41(i):Supply and Erection of Enamel Protected Area Board
Each 41(j):Supply and Erection of Retro- Reflective Sigma Board
Each 41(l):Supply and Erection of set of Isolator operation OPEN/CLOSE boards
Set 42:Supply and Erection of Shock Treatment Chart
Each 43:Supply and Erection of Protective Screens at/on ROB/FOBs
Set 33(b):Extra on erection rates for steel work manually under Item 3(a)
1.00 Block Total 278244837.00 SCR HQ-ELECTRICAL/SOUTH CENTRAL RLY
Item Breakup - A2-Foundation items
cum 2(a)(ii):Concrete for foundations and plinth in Rocky Soil
cum 2(b):Concrete for foundations and plinth in other than Hard and Rock Soil
cum 2(c)(i):Reinforced Concrete for foundation, plinth and trench
cum 2(c)(ii):Reinforced Concrete for Cable Trench covers
Sqm 2(d)(i):Reinforcement of Brick Work
cum 2(g):Casting of single under reamed pile foundation (M15 grade)
cum 2(h)(i):Reinforcement cement concrete, ratio 1:2:4 in columns with 20 mm and down graded stone aggregate and coarse sand.
cum 2(i):Breaking of foundation up to 200 mm below track formation and drain / PF surface etc
Item Breakup - B1-Steel supply
MT 3(bs):Supply of Fabricated and Galvanized structures such as TTCs, Portals, other than masts
MT 3(cs):Supply of Fabricated and Galvanized Small Parts Steel (SPS) other than Masts, TTCs and Portals.
Item Breakup - B2-Copper Supply
Kg 6(ds):Supply of 5 mm dia Hard Drawn Round Copper Dropper Wire
Kg 7(bs):Supply of 150 sq.mm Hard Drawn Stranded Copper Cross Feeder Wire
Kg 7(cs):Supply of 130 sq.mm Cadmium Copper Large Span Wire
Kg 15(as):Supply of 50 sq.mm Annealed Stranded Copper Jumper Wire
Kg 15(bs):Supply of 160 sq.mm Annealed Stranded Copper Jumper Wire
Item Breakup - B3-Insulator supply
Set 4(ax)(i):Supply of Porcelain Stay Insulator for Item No. 4(a)(i) / 4(a)(iv)
Each 4(ax)(ii):Supply of Porcelain Bracket Insulator for Item No. 4(a)(i) / 4(a)(iv)
Each 4(axx):Supply of Composite Stay and Bracket Insulators for Item No. 4(a)(i) / 4(a)(iv)
Set 4(axx)(i):Supply of Composite Stay Insulator for Item No. 4(a)(i) / 4(a)(iv)
Each 4(axx)(ii):Supply of Composite Bracket Insulator for Item No. 4(a)(i) / 4(a)(iv)
Each 4(bx):Supply of Porcelain Insulator Item no. 4(b)(i)/ 4(b)(ii)
Each 4(bxx):Supply of Composite Insulator Item no. 4(b)(i)/ 4(b)(ii)
Each 8(bx): Supply of Porcelain 9-ton Insulator for item no. 8(b)(ii)/8(b) (iii)/8(b)(vi)/8(b) (ix)/9(a)/9(b)/9(c)/9(d)/11(a)(i)/11(a)(ii)
Each 8(bxx):Supply of Composite 9-ton Insulator for item no. 8(b)(ii)/8(b) (iii)/8(b)(vi)/8(b) (ix)/9(a)/9(b)/9(c)/9(d)/11(a)(i)/11(a)(ii)
Each 11(bx): Supply of Post Insulator for Item no. 11(b) SCR HQ-ELECTRICAL/SOUTH CENTRAL RLY
Each 12(ax):Supply of Sectioning and 9-ton Insulators for Item no. 12(a)
Set 13(bx):Supply of Post and Operating Rod Insulators for Item no. 13(b) & 13(g)
Item Breakup - B4-General supply
Kilometre 14(as):Supply of PTFE Short Neutral Section Assembly
Item Breakup - C -General items
Each 18(z)(ii):Supply of Paint and Painting of ATD Counter Weight including Temperature Marking of 'Y' value for 15°C, 35°C & 45°C
Item Breakup - D -2x25KV items
Kilometre 7(d):Supply and Erection of of Buried Earth Conductor (BEC) with necessary accessories fittings and fasteners
Kilometre 7(d)(i):Supply and Erection of TEE connector for BEC end and lug for connection
Each 8(a)(i):Supply and Erection of 3:1 type Modified ATD with counter weight assembly for Conventional OHE (regulated) 2400 kgf
Each SCR HQ-ELECTRICAL/SOUTH CENTRAL RLY 13(h): Supply and Erection of DP Isolator complete with SPS, insulators and jumpering arrangement etc suitable for 2x25 kV system.
Item Breakup - E1 -Non-SOR(Additional items for 2x25kV)
Numbers NS(2):Supply of Set of cast iron counter weight (140 Kg) consisting of 03 nos. 40 Kg. (RI no. 5092) & one 20Kg. for regulating equipment
Set NS(3):Supply of 3:1 type Modified ATD as per RDSO specification no. TI/SPC/OHE/3PHTATD/0150 With ACS 1 for 2400kgf Tension
Numbers NS(4):Erection of 3:1 type modified ATD with counterweight assembly including all accessories for Conventional OHE
Each NS(5):Dismantling of PTFE Neutral section
Each NS(6):Design, fabricate,Supply, transport and erection of Anti-climbing device made with 22 gauge Galvanised steel sheet in Monkey prone area to stop climbing of monkeys on OHE masts of different types with nuts and bolts.
Each NS(7):Design, fabricate,Supply, transport and erection of Anti-climbing device made with 22 gauge Galvanised steel sheet in Monkey prone area to stop climbing of monkeys on OHE portals of different types with nuts and bolts.
Each NS(8):Supply & erection of MS Flat 50x6 mm as per IS:2062 for Cross bond arrangement
Metre Total 16390003.08
Item Breakup - E2 -Non-SOR(Crane Operator)
Man- Supply Month Total 670356.00 SCR HQ-ELECTRICAL/SOUTH CENTRAL RLY
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TD-2x25PGDP-VNUP-MTMI.pdf
ATTACHMENT
ACS-11.pdf
ATTACHMENT
GCC-2022.pdf
ATTACHMENT
ACS-1.pdf
ATTACHMENT
ACS-2.pdf
ATTACHMENT
ACS-3.pdf
ATTACHMENT
ACS-4.pdf
ATTACHMENT
ACS-5.pdf
ATTACHMENT
ACS-6.pdf
ATTACHMENT
ACS-7.pdf
ATTACHMENT
ACS-8.pdf
ATTACHMENT
ACS-9.pdf
ATTACHMENT
ACS-10.pdf
ATTACHMENT
SpecialGuidelinesPertainingto2x25kVOHE.pdf guidelines
ATTACHMENT
SpecialGuidelinesPertainingto2x25kVOHE.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].