Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.1 LAccepted-AOC | L1 | Accepted-AOC Being First Lowest | |
| 2 | L2₹18.5 L+₹75,389.80 (4.24%)Rejected-Finance | L2 | Rejected-Finance Other Than First Lowest | |
| 3 | L3₹18.7 L+₹86,128.80 (4.84%)Rejected-Finance 656 VINOBA BASTI SRI GANGANAGAR 335001 RAJ | SRI GANGANAGAR | SRI GANGANAGAR | RAJASTHAN | 335001 | L3 | Rejected-Finance Other Than First Lowest | |
| 4 | L4₹21.3 L+₹3.5 L (19.8%)Rejected-Finance | L4 | Rejected-Finance Other Than First Lowest | |
| 5 | L5₹21.9 L+₹4.1 L (22.9%)Rejected-Finance | L5 | Rejected-Finance Other Than First Lowest |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
14 Mar 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Lalgarh Jattan
GE Lalgarh Jattan
REPAIR MAINT OF EXISTING US LUMINARIES INCLUDING DAY TO DAY COMPLAINTS AT ZONE A, B, C D AT LGJ MIL STN
2024_MES_642472_1
8934-62/GE/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE Lalgarh Jattan
As per tender documents
8 documents required · 8 mandatory
₹500
GE Lalgarh Jattan
₹60,000
Yes
24 Apr 2024
15 Feb 2024
16 Mar 2024
15 Feb 2024
14 Mar 2024
29 Feb 2024
Amount
Taking down old U/S carefully copper/aluminum point wiring (light, fan, socket or power) complete including fittings such as switches, ceiling rose, pendent holder, sketch fitting, sockets, regulator etc and making good distrubed surfaces of walls and floors etc to match with the existing all as specifided and directed by Engineer-in-Charge.
Taking down old U/S carefully copper/ Aluminium submain wiring/ service connection of any type complete with casing caping / conduit etc all as directed by Engineer-in-Charge.
Taking down MCB with sheet metal enclosure, main switch, DB, etc and making good disturbed surfaces to match with existing surfaces.
M&L point wiring for one light point controlled by one switches with 1.5 Sqmm (nominal cross section area) PVC insulated unsheathed multistranded copper conductor cable in and including medium grade rigid PVC concealed conduit in wall after cutting chases in wall including cast iron or pressed steel terminal box covered with and including 3 mm thick bakelite sheet top cover fixed flush with wall using brass screws, washers and 1.5 Sqmm single core PVC insulated unsheathed copper conductor wire as earth continuity to common earth and connecting to earth dolly for one light point controlled by one switch and making good disturbed surfaces complete all as specified and directed by Engineer-in-Charge.
All as per item No 4 above, but for one ceiling/exhaust fan point controlled by one switch and regulator complete all as specified and directed by Engineer-in-Charge..
All as per item No 4 above, but for One bell/buzzer point controlled by one bell push complete all as specified and directed by Engineer-in-Charge.
All as per item No. 4 here-in-before but for one three pin 5 Amps socket outlet with 2 pin out let of 5 Amps on same board all as specified and directed by Engr-in-Charge.
All as per item No. 4 here-in-before but for one three pin 5 Amps socket outlet with 2 pin out let of 5 Amps on independent board all as specified and directed by Engr-in-Charge.
All as per item No. 4 here-in-before but controlled with two way switches complete all as specified and as directed.
All as per item No 10 here -in- before but point wiring with 4 sqmm multi stranded conductor cable and 2.5 sqmm unsheathed copper conductor earth wire for two in one 6 pin 15 Amps socket outlet on independent board all as specified and as directed by Engr-in-Charge.
Material and labour for point wiring controlled by on switches with 1.5 sqmm,FRLS, single core PVC insulated, unsheathed, multistranded copper conductor cable, with universal colour code drawn in existing steel/PVC conduit/casing capping in existing sunken pressed steel terminal boxes, providing 3 mm thick plastic laminated sheet top cover including 1.5 sqmm PVC insulated, unsheathed, multistranded copper conductor cable as earth wire in green colour and making good the disturbed surfaces in cement mortar (1:3), complete all as specified & directed for light point controlled by one switch complete.
All as per item No 11 above, but for one ceiling/exhaust fan point controlled by one switch and regulator.
All as per item No 11 above, but for for bell point controlled by one bell push complete.
All as per item No 11 above, but for 3 pin 5 Amp socket outlet on the same board with other switch, sockets complete all as specified and as directed.
All as per item No 11 above, but for for 3 pin 5 Amp socket outlet independent complete.
All as per item No. 11 here-in-before but controlled with two No. two way switches completye all as specified and as directed.
All as per item No 11 here -in- before but point wiring with 4 sqmm multi stranded conductor cable and 2.5 sqmm unsheathed copper conductor earth wire for two in one 6 pin 15 Amps socket outlet on independent board all as specified and as directed by Engr-in-Charge.
Supply & fixing switch piano type flush button single pole one way 5/6 Amps, 230 volts all as specified & directed by Engineer-in- charge.
M&L in repair switch piano type flush button single pole one way 5/6 Amps, 230 volts inc taking down old one all as specified & directed by Engineer-in- charge.
Supply & fixing switch piano type flush button double pole two way 5 Amps, 230 volts all as specified & directed by Engineer-in- charge.
Supply & fixing in repair switch piano type flush button single pole one way 5 Amps, 230 volts inc taking down old one all as specified & directed by Engineer-in- charge.
Supply & fixing socket outlet 2 in 1, 3 pin 5 Amp,flush type all as specified & directed by Engineer-in- charge.
Supply & fixing electric bell ding dong 230 volts AC supply all as specified and directed by Engineer-in-Charge.
Supply & fixing in repair electric bell ding dong 230 volts AC supply incl taking down old one complete all as specified and directed by Engineer-in-Charge.
M&L Iin repair socket outlet 2 in 1, 3pin 5amp, flush type incl taking down old one complete all as specified & directed by Engineer-in- charge.
Supply & fixing bell push flush button 5/6 Amps, 230 volts complete all as specified & directed by Engineer-in- charge.
Supply & fixing switch piano type flush button single pole one way 15/16 Amps 230 volts all as specified & directed by Engineer-in- charge.
M&L in repair switch piano type flush button single pole one way 15/16 Amps 230 volts all as specified & directed by Engineer-in- charge.
Supply & fixing socket outlet two in one, 6 pin 5 Amp and 15 Amp flush type all as specified & directed by Engineer-in- charge.
Supply & fixing in repair socket outlet 2 in 1, 6 pin 5 Amp and 15 Amp,flush type all as specified & directed by Engineer-in- charge.
S & F in repair sheet metal single pole and neutral enclosure 240 volts with a two pin and earth plug and socket complete with 20 Amp single pole MCB complete all as specified and as directed by Engr-in-charge.
S & F Lamp holder incl LED lamp 9 watt, insulated body with back plate etc all as specified and as directed by Engr-in-Charge.
Supply & fixing ceiling rose surface bakelite 65 mm x 50 mm size, 3 terminals complete all as specified and directed by Engineer-in-Charge.
S & F fan regulator electronic socket type 80/100 watt all as specified and as directed by Engr-in-charge.
M & L in repair fan regulator electronic socket type 80/100 watt including taking down old one complete all as specified and as directed by Engr-in-charge.
Supply and fixing in repair LED tube light fitting polycarbonate housing 1 x 20 Watt, appx 4 feet long, with decorative box linear, housing environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 110 Lumen per watt. (b) Input Voltage range : 140 to 270 volts. (c) Temp operating range : Minus 5°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Current THD Max10% and voltage THD max 5% (f) IP rating : IP-20. (g) LED Driver of the same make as of the luminaire. (h) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (j) Surge protection minimum 2.5 kV. (k) CCT : Minimum 6000K (l) CRI : Minimum 80 (m) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
Supply and fixing in repair LED Bulkhead fitting 1 x 10 Watt, complete with Standard LED lighting fixture with extruded polycarbonate housing environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to light fitting, complete fitting with all accessories and following specifications complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 5°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : <15%. (f) IP rating : IP-65. (g) CCT : Minimum 5400K (h) Polycarbonate housing white coloured (j) LED Driver of the same make as of the luminaire. (k) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (l) Surge protection minimum 2.5 kV. (m) CRI : Minimum 80 (n) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
Supply and fix in repair Switch socket combination 2 in 1, 5 A flush type inc taking down old onecomplete all as specified and as directed.
Supply and fix in repair Switch socket combination 5A/16A, 5 in 1inc taking down old one complete all as specified and as directed.
Supply and fix in repair modular Socket, 6A - 2/3 pin combined 2 module inc taking down old one complete all as specified and as directed.
Supply and fix in repair modular Socket, 6A/16A - 2/3 pin combined 2 module inc taking down old one complete all as specified and as directed.
Supply and fix in repair modular Modular switch 1 way 6 A, 1 module inc taking down old one complete all as specified and as directed.
Supply and fix in repair modular Modular switch 1 way 16 A, 1 module inc taking down old one complete all as specified and as directed.
Supply and fix in repair modular Fan step regulator, 120W - 2 module inc taking down old one complete all as specified and as directed.
S & F in repair factory made sheet metal distribution boards, SPN, 12 way double door; protection class IP-30 suitable for mounting MCB/ conforming to IS- 8623 with 200 Amps rated copper bus bar suitable for working on 240 volts AC supply complete all as specified & directed by Engineer-in- charge.
S & F in repair factory made sheet metal distribution boards, SPN, 8 way; double door; protection class IP-30 suitable for mounting MCB/ MCCB, conforming to IS- 8623 with 200 Amps rated copper bus bar suitable for working on 240 volts AC supply complete all as specified & directed by Engineer-in- charge.
S & F in replacement of factory made sheet metal distribution boards, vertical type double door TPN, 4 way;with 200Amps rated copper bus bar suitable for working on 415 volts AC supply complete all as specified & directed by Engineer-in- charge.
S & F in repair MCB tripple pole 63 Amp, 415 Volts, rupturing capacity 9 KA confirm to IS- 8828-1996, IEC - 60898 complete all as specified and directed by Engr-in-charge.
S & F in repair MCB SPN 63 Amp, 240 Volts, rupturing capacity 10 KA confirm to IS- 8828- 1996, IEC - 60898 complete all as specified & directed by Engr-in-charge.
S & F in repair MCB SPN 32 Amp, 240 Volts, rupturing capacity 9 KA confirm to IS- 8828-1996, IEC - 60898 complete all as specified and directed by Engr-in-charge.
S & F in repair MCB SP 6 to 32 Amp, 240 Volts, rupturing capacity 9 KA confirm to IS- 8828- 1996, IEC - 60898 complete all as specified & directed by Engr-in-charge.
S & F in repair MCB tripple pole & Nuetral 63 Amp, 415 Volts, rupturing capacity 9 KA complete all as specified and directed by Engr-in-charge.
Sub main wiring with two single core PVC sheathed insulated cable of 6 sqmm size copper multi stranded conductor 1100 volts grade drawn-through and including 25 mm dia stove enamelled rigid steel conduit of adequate size of conduit and junction boxes,terminal boxs,terminal 6 sqmm copper conductor unsheathed multi stranded earth wire earth continuty conductor. (Two run of single core cable and one run of 6 sqmm copper wire earth continuty conductor and conduit with accessories shall be measured as one length) complete all as specified and directed by Engineer-in-charge.
Sub main wiring with Four single core PVC sheathed insulated cable of 10 sqmm size copper multi stranded conductor 1100 volts grade drawn-through and including 32 mm dia stove enamelled rigid steel conduit of adequate size of conduit and junction boxes,terminal boxs,terminal boxes and accessories such as tees, bend elbows, reducers, bell mouth tube ends fixed concealed in wall including one run of 6 sqmm copper conductor unsheathed multi stranded earth wire earth continuty conductor. (four run of 10 Sqmm single core cable and one run of 6 sqmm copper wire earth continuty conductor and conduit with accessories shall be measured as one length) complete all as specified and directed by Engineer-in-charge.
S & F 1100 volts grade heavy duty PVC insulated aluminium stranded conductor cable served with inner sheathing twin core flat or circular of size 10 sqmm in service connection & suspended by insulating hangers not more than 1 metre apart including 4 mm dia GI suspension wire all as specified & directed by Engineer-in-charge.
Supply and fixing in repair energy efficient LED security light fitting of 25W pressure die cast aluminium housing/body, heat resistant clear toughened glass, better optics for uniform distribution street luminaire, with driver, including electric connection with using 2 core flexible copper conductor cable 1Sqmm from ceiling rose to light fitting, fixing the light fitting with new bracket made out of GI tubing light grade 32mm dia, 1.5 metre long bent to shape at 120 degree angle at half metre from bottom, including two Nos clamps made out of MS Flat iron size 25x3 mm with suitable nuts and bolts for fixing of bracket including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 110 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) IP rating : IP66. (g) IK rating : Minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection 10 kV (inbuilt + extended) (l) CCT : 5700 K. (m) CRI : Minimum 70 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs @L70
M&L for repair to door hinges of sheet metal cabinet of 22 SWG of CRCA of size 660 mm x 660 mm x 200 mm icluding necessary welding and painting the cabinetl with two coat of synthatic enamelled paint over a coat of red oxide primer and reaarangig all elctrical connection in the box complete all as specified and as directed.
Supply and fixing MS sunken box 1.2 mm thick and min 60 mm deep including making good the disturbed surfaces with cement mortar complete all as per existing sizes.
Supply and fixing bakelite hylem sheet of size as per existing switch board and tightening with brass screw and cup washers complete all as specified
S& F fresh air fan 230 mm sweep, single phase 230 volts 50 Hz including grouting with fasteners, nuts/bolts etc complete all as specified.
Excavation in trenches not exc 1.5 m wide and n. exc 1.5 m deep in soft/loose soil for foundation/cable etc n exc 10 Sqm on plan and n exc 1.5 Sqm in depth all as specified and directed by Engr-in-Charge
Returning, filling in including spreading levelling, watering and well ramming in layer n. exc 25 cm thick complete all as specified and directed by Engr-in-Charge
Removing surplus soil to a distance n. exc 50 m and depositing where directed at level n. exc 1.5 m above the starting point complete all as specified and directed by Engr-in-Charge
M&L sand cushioning with dry coarse sand to under ground cable 230 mm deep (80 mm below and 150 mm above the cable ) complete all as specified and directed by Engr-in-Charge
M&L brick protection with sub class'B' brick laid flet across the cable complete all as specified and directed by Engr-in-Charge.
Supply and laying in replacement LT XLPE cable 1100 Volt grade 16 Sqmm 4 Core with stranded aluminium conductor PVC sheathed armoured confirming to IS 1556 laid in trenches/along poles/ through pipe/through duct complete including taking out all as specified and directred by Engr-in-Charge.
Supply and laying in replacement LT XLPE cable 1100 Volt grade 25 Sqmm 4 Core with stranded aluminium conductor PVC sheathed armoured confirming to IS 1556 laid in trenches/along poles/ through pipe/through duct complete including taking out all as specified and directred by Engr-in-Charge.
Supply and laying in replacement LT XLPE cable 1100 Volt grade 35 Sqmm 3.5 Core with stranded aluminium conductor PVC sheathed armoured confirming to IS 1556 laid in trenches/along poles/ through pipe/through duct complete including taking out all as specified and directred by Engr-in-Charge.
Supply & Fix in replacement of MCCB 4 Pole, 415 V, Adjustable type, 100 Amps with breaking capacity 25 KA all as specified and directed
Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ
Ganganagar Enterprises
jassal engineering
M/s Tarun Traders
Soma Enterprises
Aggarwal brothers and company
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .