Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹4.8 LAccepted-AOC | 1 | Accepted-AOC BEING LOWEST | |
| 2 | 2₹5.0 L+₹13,149 (2.69%)Rejected-Finance | 2 | Rejected-Finance Being not lowest | |
| 3 | 3₹5.8 L+₹93,741 (19.2%)Rejected-Finance | 3 | Rejected-Finance Being not lowest | |
| 4 | 4₹6.0 L+₹1.1 L (21.9%)Rejected-Finance | 4 | Rejected-Finance Being not lowest |
Tender Value
Refer Docs
EMD Value
₹12,000
Closing Date
22 Jul 2021, 6:00 pmClosed
AGE (I)
AGE (I) Fatehgarh Cantt.
SPL REPAIR TO BLDG NO T-06AT MILLITARY HOSPITAL FATEHGARH CANTT
2021_MES_445191_2
AGE(I) /FAT/ET-06 OF 2021-2022
Open Tender
Miscellaneous Works
Item Rate
120 days
AGE (I) Fatehgarh
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
AGE (I) Fatehgarh
₹12,000
Yes
10 Sept 2021
25 Jun 2021
24 Jul 2021
25 Jun 2021
22 Jul 2021
25 Jun 2021
Amount
Demolition of PCC in Ground floors/PCC Path/Plinth Protection and paving n.exc 15cm thickness (below or above ground level) etc complete all as specified and directed.
M&L for 75 mm thickness PCC (1:3:6) type C-2 using 40mm stone aggregate in plinth protection including finishing smooth without using extra cement, complete all as specified and directed.
Dismantiling Floor, hearth or Wall tiling including cement mortar bedding (but not baking), removing serviceable tiles to store and rubbish off the premises etc complete all as specified and directed.
M&L Glazed ceramic coloured tiles 350x250x7mm / 450 x 350 x 7mm thick as in Vertical surfaces set and jointed in neat cement slurry and jointed or coloured cement to match etc complete over 15 mm th rendering in CM 1:4 complete all as specified and directed.
S&F Non Skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceedifng 0.18 sqm but not exceeding 0.36 sqm in floors and skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 15 mm screed bed in CM (1:4) complete all as specified and directed.
S&F in repair false ceilng Horizontal level regular edge grid 600mm X 600mm from work using hot dip sections and fixing tiles vinyl laminated MPL gypsum panels size 595 X 595 X 8 mm thick after lamination suspended the grid with grid hanger to roof truss/ RCC slab complete all as specified and directed.
Taking down Cement Plaster on brick work or concrete surfaces incl racking out joints etc complete all as specified and directed.
M&L for 15mm thick Rendering in CM 1:6 on brick work or concrete surfaces finished even and smooth etc complete all as specified and directed.
M&L for 15mm thick Rendering in CM 1:4 on brick work or concrete surfaces finished even and smooth etc complete all as specified and directed.
M&L preparation of Newly plastered surfaces and applying two coats of oil emulsion distemper over priming coat complete all as specified and directed.
M & L for two coats of Cement based paint over a coat of alkali resistant primer on new plastered wall surfaces including preparation complete all as specified and directed.
Taking down Chowkhats incl shutterrs (without taking off shutters from the frame) n.exc 1.5 sqm each etc complete all as specified and directed.
Taking down Chowkhats incl shutterrs (without taking off shutters from the frame) exc 1.5 sqm and n.exc 4.00 sqm each etc complete all as specified and directed.
S&F anodized aluminium frame work for door, window, ventilators made out of approved section including necessary joining cleats, glazing clips, rubber packing, anodized aluminium snap beading screws complete all as specified and directed. Note :- (i) Fabrication work shall be got done approved fabricator or manufacture of aluminium sections.
S&F anodized aluminium door shutters, aluminium section weighing 0.55 Kg/m including clips, rubber neoprrene packing,handle 2 Nos in each door ,hinges anodised aluminum snap beading screws etc. complete all as specified and directed. Note :- Fabrication work shall be got done approved fabricator or manufacture of aluminium.
S&F anodized aluminium window and ventilator shutters,side hung type without sash bars, aluminium sections weighting 0.55 Kg/m incl providing necessary joining cleats,glazing clips,rubber packing,anodised aluminium snap beading screws, anodised aluminium fittings such as peg stays 150 mm long ( 1 No.) hinges type B-21 100 mm long (2no.) suitable handle 1 no.), complete all as specified and directed. Note :- Fabrication work shall be got done approved fabricator or manufacture of aluminium.
S&F sheet glass 5.5mm thick ordinary quality complete all as specified and directed.
S&F aluminium composite panel having 3mm thick exterior grade PVDF coating complete all as specified and directed.
Dismantling timber scantlings 40 Sqcm and over in section, in any position, unframed work and removing obtained materials from site complete all as specified and directed.
Dismentaling of asbestos cement (Corrugated, semi corrugated etc) sheetiting in roof covering all as specified and directed by Engineer-in-Charge.
M&L 6mm thick asbestos cement, corrugated or semi-corrugated sheets in roof, fixed with L type or J type or cranked hook bolt complete all as specified and directed.
M&L for rolled mild steel in rolled section as in main and cross beams, hip and jack rafter, purlins where connected to comman rafter and running rails, fixed with angle cleats or other connecting plates of Fe 410-W (Gde - E-250) quality A complete all as specified and directed.
S&F prepainted galvalume sheet aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick (TCT) of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws all as per manufacturer instruction complete all as specified and directed.
M&L Preparing surfaces new of steel and applying two coats of SE paint over a coat of red oxide primer, complete all as specified and as directed.
M&L cement concrete type B-1, (1:3:6) using 20 mm broken stone as in foundation, filling and mass conrete complete all as specified and as directed.
S&F in Door closer hydraulically regulated, designation No. 3 , universal type , suitable for door shutters of 851 to 1000mm in width and of weight between 61 to 80 Kg and fixed complete all as specified and directed.
S&F 250 mm long Aluminium alloy. Anodised, sliding door bolt with hasp, staple ( bolt type) and fixing clips of sheet , cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed.
Demolition of brick work or stone / boulder masonry built in cement mortar incliding all quoins,arches,pillars etc complete all as specified and directed.
M&L brick work using old size sub class B bricks cum strainght or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed.
.....ditto as above but except brick ..ditto...
Taking down copper/aluminium point wiring of any discrapation and any position (light, fan, socket or power point) complete, including fixture and fittings such as switches,socket, ceiling rose,lamp holder,pendants, bracket and regulator etc and removing material from site including making good disturbed surface to match with the existing surface complete all as specified and directed.
Taking down Aluminium sub main wiring and making good disturbed surfaces to match with the existing surface roof/wall/floor complete all as specified and as directed
M&L for point wiring for One light/fan/bell/exhaust fan point controlled by one switch with 1100 volt grade PVC insulated-unsheathed 1.5 Sq mm (FRLS) multistranded copper conductor cable, with continuous earth wire of 1.5 Sq mm (FRLS) multistranded copper conductor cable PVC insulated-unsheathed, drawn in & including concealed PVC conduit medium grade with fittings (ISI marked) not less than 19 mm dia & 1.6 mm thick sunken pressed steel galvanised terminal boxes with top cover 2.80 mm thick ISI marked plastic laminated hylam sheet of required colour for housing/ fixing switches etc complete all as specified and directed Note- Cutting chases for concealed point wiring shall be made good by the contractor at his own cost with using Cement Mortar ( 1:4)/PCC ( 1:2:4) type B-0 (using 12.5mm graded stone aggregate) and surface finished to match the existing surface.
...ditto .. but point wiring for One 5 pin 5 Amp switch socket out let point on an independent board ..ditto...
...ditto .. but point wiring for One 5 pin 5 Amp socket out let point controlled by one switch on same board ..ditto...
...ditto .. But point wiring for one 15 Amp 6 Pin switch socket out let on independent board with using 2.5 Sqmm FRLS unsheathed copper conductor single core multistranded cable complete all as specifed and directed.
S&F switch piano flush type 5 Amp single pole one way complete all as specifed and directed.
S&F socket 2 in 1 flush type 5 Amp 5 Pin complete all as specifed and directed.
S&F switch socket combination 5 in 1, 5/15 Amp flush type complete all as specifed and directed.
S&F elctrnoic fan regulator 5 stepped type complete all as specifed and directed.
S&F ceiling rose PVC/Poly carbonate isolated body three terminal AC 230 volts complete all as specified and directed.
M&L for sub main wiring with two single core 6 Sqmm FRLS copper conductor PVC insulated and unsheathed cable including PVC conduit medium grade (appropriate size) concealed in wall for sub main connection including 4 Sqmm FRLS insulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly complete all as specified and directed. ( Note :- Two runs of 6 sqmm FRLS and one run of 4 sqmm FRLS copper conductor shall be measured as one unit length.)
Supply and fixing in replacement MCB distribution board SPN 240 Volt 8 way with 200 Amp rated bus bar having IP-43 protection and double metal door concealed in wall including connection with copper thimbles as required complete all as specified.
S&F in replacement of MCB SPN 16-40 Amp 240 volt 'C' curve complete all as specifed and directed.
S&F in replacement of MCB SP 6 to 32 Amp 240 Volt 'C' curve 10 KA complete all as specified and directed.
S&F LED wall light 12 W unbreakable poly carbonate suitable for mounting on wall /surface complete all as specified and directed. (Make: Surya Cat No SLE WL 12 W-GP200 or equivalent to specified make )
S&F surface and wall mounted 18/20W LED extruded aluminium batten fiitting provided for efficient heat dissipation including LED retrofit polycarbonat tube complete all as specified and directed.
Supply and fixing PVC exhaust fan of sweep 300 mm complete with self closing MS louvers, mounted in suitable opening arrangement and suitable on 230 volt singal phase 50Hz AC supply and connecting up with and including opening of suitable hole, fixing and making connection and fixed by using 4 Nos 200 mm long 12 mm dia bolts, nuts and washers and grounted in wall in CM 1:3 complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick, burried directly into the ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to GI earth wire 4 mm dia by means of bolts, nuts, check nuts, and washers of galvanised iron or steel all as shown iln electrical plate No - 3 connected to earthing test point all as specified or indicated including excavation and connected earth work, PCC chamber and cover, watering pipe, funnel wire mesh but without earth lead protection pipe and test on completion after dismantling unserviceable erthing (above GL only) complete all as directed incl dismantling of exsisting earthing. ( Note :- On testing after completion if desired earth resistence is not obtained, the earthing will be redone at no extra cost.)
M/S BABA BUILDERS
M/S S P CONSTRUCTION
Shree Gopal Engineers & Contractor
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .