Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.1 LAccepted-AOC OLD PAHARGAON POLY TECHNIC ROAD DOLLYGUNJ SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | ₹43.1 L Quoted ₹43.2 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹44.5 L+₹1.3 L (2.95%)Rejected-Finance 2ND CROSS DEEN STREET M G ROAD JUNGLIGHAT POST SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744103 | ₹44.5 L+₹1.3 L (2.95%) | L2 | Rejected-Finance Not being L1 |
| 3 | L3₹44.7 L+₹1.5 L (3.38%)Rejected-Finance | ₹44.7 L+₹1.5 L (3.38%) | L3 | Rejected-Finance Not being L1 |
| 4 | L4₹44.9 L+₹1.6 L (3.71%)Rejected-Finance | ₹44.9 L+₹1.6 L (3.71%) | L4 | Rejected-Finance Not being L1 |
| 5 | L5₹45.4 L+₹2.2 L (5.04%)Rejected-Finance NEAR OLD CCS JUNGLIGHAT SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | ₹45.4 L+₹2.2 L (5.04%) | L5 | Rejected-Finance Not being L1 |
Tender Value
₹43.5 L
EMD Value
₹87,100
Closing Date
9 Nov 2024, 6:00 pmClosed
GE HADDO PORT BLAIR
GARRISON ENGINEER HADDO Military Engineer Services Haddo Post Port Blair Andaman and Nicobar 744102
PROVN OF WAITING ROOM AT HQ ANC UNDER GE HADDO AT SRI VIJAYA PURAM
2024_MES_680296_1
8929/E8
Open Tender
Civil Works
Item Rate
180 days
GE HADDO PORT BLAIR
As per tender document
9 documents required · 9 mandatory
₹500
GE HADDO
₹87,100
Yes
21 Jan 2025
19 Oct 2024
16 Nov 2024
19 Oct 2024
9 Nov 2024
2 Nov 2024
20 Oct 2024 - 26 Oct 2024
Amount
Excavation in trenches n. exc 1.5m wide and not exc 1.5m in depth depth in hard/dense soil for foundation, etc or for shafts, wells, cesspits, manholes, pierholes, etc n. exc 10 Sqm on plan and getting out complete all as specified and directed
All as per Item No. 1 but additional 1.5m or part there of in depth beyond the first 1.5m complete all as specified and directed
Surface excavation n. exc 30 cm deep and averaging 15 cm deep in any type of soil and getting out complete all as specified and directed
M&L for returning filling in hard/dense soil including spreading levelling watering and well ramming in layers n. exc 25cm thick complete all as specified and directed
M&L for removing excavated material (any type of soil) to a distance n. exc 50m and depositing where directed at a level n. exc 1.5m above the starting point complete all as specified and directed
M&L Cement concrete 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundations or mass concrete complete all as specified and as directed
M&L for nominal mix RCC 1:1.5:3 type A1 (using 20mm graded crushed stone aggregate) in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc, basement slabs, under-reamed piles and mass concrete complete all as specified and directed
M&L for nominal mix RCC 1:1.5:3 type A1 (using 20mm graded stone aggregate) in columns, pillars, piers, posts and struts complete all as specified and directed
M&L for nominal mix RCC 1:1.5:3 type A1 (using 20mm graded stone aggregate) in beams, cantilevers, bressummers, lintels over 1.5m span all as specified and directed
M&L for nominal mix RCC 1:1.5:3 type A1 (using 20mm graded crushed stone aggregate) in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed
M&L formwork for rough finished flat surface to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work, vertical or to batter complete all as specified and directed
M&L formwork for rough finished surface of square, rectangular or triangular surface to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed
M&L formwork for rough finished flat surface to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup-ports, overhangs, etc also splays between floors and beams, etc complete all as specified and directed
M&L formwork for rough finished flat surface to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exceeding 200mm thick (horizontal or sloping) complete all as specified and directed
M&L formwork rough finished surface of concrete to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n. exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 5cm but n. exc 10 cm wide complete all as specified and directed
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed
M&L for mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed
M&L precast cement concrete block masonry exc 10 cm width with solid block PCC 1:3:6 type C1 (using 20 mm graded stone aggregate) and setting in cement mortar 1:6 all as specified
M&L for 10mm thick plaster in CM 1:6 on fair face of concrete surface or brick walls finished even and smooth without using extra cement complete all as specified
M&L for preparation of newly plastered surface of wall and applying two coats of oil bound distemper over a coat of average 1mm thick wall care putty to make the surface smooth complete all as specified and directed
M&L for 15mm thick plaster in CM 1:4 including liquid water proofing compound @ 200ml per 50 Kg cement bag on fair face of brick walls or concrete surface, finished the surface even and smooth without using extra cement complete all as specified (Note : WPC shall be measured and paid seperately)
M&L for preparing newly plastered wall surface and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 Sqm complete all as specified and directed
M&L for 10mm thick plaster in CM 1:3 on concrete ceiling surfaces finished even and smooth without using extra cement complete all as specified
M&L for preparation of newly plastered ceiling surface and applying two coats of oil bound distemper of approved tint over a coat of average 1mm thick wall care putty complete all as specified and directed
M&L for 25mm thick cement concrete 1:2:4 type B0 (Using 12.5mm graded stone agrregate) as in levelling course, padding etc complete all as specified and directed
M&L for vitrified ceramic tiles light shade 10mm thick (square/ rectangular) polished, area of each tiles exc 0.42 Sqm but n. exc 1 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed of cement mortar 1:4 complete all as specified and directed
M&L for vitrified ceramic tiles light shade 10mm thick (square/ rectangular) polished, area of each tiles exc 0.42 Sqm but n. exc 1 Sqm as in vertical surface such as dado/ skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick rendering in CM 1:3 to recieve tiles complete all as specified and directed
M&L for hardcore of broken stone or boulders of gauge n. exc 63 mm deposited spread and levelled in layers n. exc 15 cm thick watered and rammed to a true surface complete all as specified and directed
M&L for 100mm thick PCC 1:4:8 type D2 (Using 40mm graded stone aggregate) as in path finish the top surfaces even and rough to receive top layer complete all as specified and directed
M&L for 75mm thick PCC 1:3:6 type C1 (Using 20mm graded stone aggregate) as in plinth protection/path laid in panels, finish the top surfaces even and smooth complete including filling the joints with mastic compound all as specified and directed
M&L for plain cement concrete 1:3:6 type C1 (using 20mm graded stone aggregate) as in surface channel or drain or benching in manhole including necessary formwork complete all as specified and directed
M&L for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement including forms, moulds, mitered/stopped ends etc complete all as specified and directed
M&L for chequered cement concrete tiles of size 30cm X 30cm X 25mm thick with grey cement and pigments set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile as in floor over and including 20mm thick screed bed in CM 1:4 complete all as specified and directed
S&F for 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified
M&L for PCC 1:2:4 type B0 (using 12.5mm graded stone aggregate) as in coping, edging including necessary form work complete all as specified
M&L 14-16mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed
M&L for 20mm thick plaster on RCC roof slab in CM 1:4 including liquid water proofing compound @ 200ml per 50 Kg cement bag complete all as specified (Note : WPC shall be measured and paid seperately)
Supply only liquid water proofing compound
M&L for non glazed ceramic coloured wall cladding tiles 9-10mm thick area of each tiles n. exc 0.18 Sqm as in vertical surface incl cutting the tiles for fixing on curved surfaces set and jointed in neat cement slurry and pointed with white or coloured cement over and including 10mm thick rendering or bedding layer of cement mortar 1:3 complete all as per sample kept in the office, specified and directed by Engr-in-Charge
S&F 12mm thick toughned glass in required sizes in openings duly crystal polished at the edges and with full etched design finalised by GE in different colours fixed with stainless steel brackets of size 50x25mm, 100mm long made out with 3mm thick SS sheet at the top and bottom, stainless steel hinges & brackets to connecting to glass to glass, wall to connector, magnetic seal, middle seal etc all as specified
S&F 12mm thick toughned glass doors (frameless) in required size duly crystal polished at the edge and with full etched design finalized by GE in different colours fixed with stainless steel brackets of size 50x25mm, 100mm long made out with 3mm thick SS sheet at the top and bottom, Door fittings & floor springs or SS pivot, stainless steel handles 600mm 'D' type and locking arrangement to each door, stainless hinges to connect glass to glass, wall to glass connector, magnetic seal, middle seal and the water dispenser etc all as directed (Note : It includes all necessary hardwares required for functioning)
M&L for 18mm thick designed rubco hut rubber wood frame shutter for cupboard, WHB counter cupboard, wall with finish to match all adjoining surfaces including sanding and applying mixture of filler and NCD thinner (Sheenlac make), pasting chalk putty, applying sealer (Sheenlac make) and wall nut colour stainer and finally applying waxpol (Silicon make) complete all as specified and as directed
M&L for preparation of new/old wooden surfaces and applying melamine polish through the process of snading with wood sanding paper of size 60 & 80 and applying wood filler mixed with NCD thinner including applying wood putty on shabby/ nailing area and sanding with sand paper of size 120 and applying sealer and walnut colour stainer and sanding with sand paper of size 320 and melamine polishing with spray application and again sanding with 400 sand paper and finally applying silicon of make Waxpol with soft fine cloth for better shining and finishing complete all as specified and directed
M&L for seamless designed gypsum board false ceiling 12mm thick including for any sunk or raised moulding with 25mm long self drilling/ tapping screws having philips head with joining compound and 48mm wide fiber tape to provide seam less finish and including GI frame work of seamless ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flange of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm c/c intermediate channel 0.9mm thick having two equal flanges of 15mm suspended from soffit at approx 900mm c/c with GI cleats and steel expansion fasteners with and incl ceiling section ( not exc 1.2m length) of 0.55mm thick having kurled web of 50mm an flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with connecting across the intermediate channel at 457mm c/c incl hangers 6mm dia GI adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long complete and finally applying two coats of oil bound distember with roller finish over a coat of chalk whiting primer cmplete all as specified and directed
Supply only sheet glass, ordinary quality 5.5mm thick in uPVC window/ventilator shutter n. exc 0.5 Sqm in each pane complete all as specified and as directed
Supply,laying,testing and commissioning of LT XLPE insulated, armoured heavy duty electric aluminium conductor cable 1100 Volts grade 3.5 core of cross section 35 sqmm (laid in terenches, ducts, pole ,wall etc.) all as specified and directed
Supply and laying in trenches or in cable ducts or clamping on wall DWC HDPE pipe of size 50 mm(OD) x 38 mm (ID) along with connected accessories like couplers, bends, end caps etc. for LT cable protection all as specified and directed
M&L point wiring complete with 1100 volts grade, 1.5 sq.mm (nominal area), single core, FRLS PVC insulated ,unsheathed, multi stranded copper conductor cable drawn through and including medium grade, rigid , non-metallic PVC concealed conduit of size not less than 20mm dia, with all necessary fittings, concealed in walls /roof/ floor duly earthed with one run of single core cable of same size but green in colour as continuous earthing wire and connecting to common earth duly including suitable size of factory made fabricated MS sheet modular terminal box, flush mounting in the wall for mounting switches/switch socket combinations/ fan regulators etc., covered with suitable size of modular cover plates complete in making good the existing surface with existing colour coding as required at site complete all as specified for the following :-
Description same as per item Ser No 49 above but for One light/fan point controlled by one modular switch 5 Amps one way
Description same as per item Ser No 49 above but for two light point controlled by one switch 5 Amps one way complete all as specified and directed
Description same as per item Ser No 49 above but for one modular 3 pin 5 Amp socket out let on independent board
Description same as per item Ser No 49 above but for one modular 3 pin 5 Amps switch socket on same Board
Description same as per item Ser No 49 above but point wiring with 4.0 sqmm PVC FRLS insulated multistranded copper conductor suitable for one 3 pin 15 Amps socket out let and one run of 4.0 sqmm cable for earth in green colour on independent board
S&F for switch modular type, 6 Amps 1 module, 230 volts AC circuit complete all as specified and directed
S&F for socket outlet modular type 1 way 6 Amps, 3 pin, 230 volts AC circuit complete all as specified and directed
S&F Socket outlet 2 in 1 modular type, 3 pin, 6 and 16, universal all as directed
S&F Switch modular type , single pole one way 16 amps all as directed
S&F Ceiling rose PVC polycarbonate , isolated body 3 terminals 230 V complete
S&F stepped type electronic fan regulator modular type complete all as specified
Supply & fix starter switch of capacity 25 Amps working on 240 volts AC supply alongwith with 25 Amps mini MCB SP type 'C' 240 volts for air conditioner including suitable size of factory made fabricated MS sheet modular terminal box, flush mounting in the wall complete all as specified and directed Make:- Anchor (Roma) or equivalent in Havells /leader / cona.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) Make: CG Model No : ENERGION Riviera with out remote 32 watt or equivalent make of Havells/Orient/Usha.
Supply & fixing Wall mounting fan 400 mm sweep incl all fixing arrangement complete all as specified and directed Make: Havells Model No : 400 mm FHWMWHSWHB16 (Marvel Wind HS White Blue) or equivalent to CG/ Usha/ Orient
Supply and fixing of Decorative ultra slim linear LED lighting fixture of 18 Watt recess mounted 220V , 50Hz with Aluminium housing ,environmental friendly energy efficient fitting recess mounted round/square in shape (Warm white/ white colour as per requirement of site complete) of light as required at site) complete all as specified and directed Make - Philips Cat Part No : Dura Slim or equivalent make in CG//Havells / Luker. NOTE: The rate quoted deemed to include for any alterations required to existing false ceiling as per site condition for fixing light fitting .
Description all per item No 59 above but 15 watt
S&F concealed cob/ spot LED light energy efficient of cap 4 watt (WH/WW/NW of colour) LED for low ceiling height applications round in shape, pressure die-cast aluminium housing, spring loaded clips for easy mounting complete all as directed Make : Luker LCOB04 or equivalent to Havells /Philips /CG
S&F LED light, Flexible neck for adjusting beam, Bronze finish for superior feel, aluminium housing of cap 12 watt complete all as specified and directed by Engr-in-Charge Make : Philips model No - 31403 or equivalent to CG, Havells
S&F LED Strip light, 60 LED per metre, 24 watts with driver, 5 metre length, of any colour (WW/NW/CDL), including all fixing arrangment as per site requirement complete all as specified and as directed The cradle is provided for monitoring purpose all as directed Make : Philips Model: Skycove or equivalent to CG/ Havells
S&F Sub main wiring with PVC insulated FRLS cable 2 runs single core 4.0 sq mm 1100 V grade with stranded copper conductor cable using proper colour coding Phase Red /Yellow /Blue, Neutral- black and earth- green in and incl suitable size rigid PVC concealed/surface conduit (ISI marked) incl all specials/ accessories etc and provision of PVC insulated FRLS copper conductor single core 4.0 sq mm for earth continuity all as directed Note : 3 runs of cable and 1 runs of PVC conduit shall be measured as 1 unit.
S&F Triple pole and neutral sheet steel powder coated Distribution board IP -54 protection with door earthing for MCBs fitted with 200 Amps rated bus bar , Neutral link ,Earth Bar and Din rail suitable for use on 415 V, 50 Hz supply double door TPN DB system 04 ways (8+12) modules, and making good to the distrubed surface /walls complete all as specified and directed
S&F SPN DB sheet metal enclosure double door suitable (IP-43) Protection 8 Way with 200 Amp rated standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete
S&F of MCB, TPN, "C" series, 415 volts, 63 Amps, 10 KA rupturing capacity complete all as specified and as directed
S&F of RCCB, 4 pole, 63 Amps, 100 mA rupturing capacity complete all as specified and as directed
Supplying & fixing MCB SPN 32 Amps (`C’ series) having current rating 10 KA complete all as specified and directed
Supplying & fixing MCB single pole, 6 to 32 Amps (`C’ series) having current rating 10 KA complete all as specified and directed Note for item No 65 & 70 :- All copper conductors should be connected with MCB alongwith copper reducer terminals of suitable size duly crimpled.”
M&L Cutting channels, grooves or rebates n exc 15cm girth, and trimming surface with or without reinforcement all as specified and as directed by Engr-in-Charge
Earthing complete with galvanised earth plate electrode 60 cm x 60cmx 6.15 mm thick, buried directly in ground vertically (earth pit not less than 2.25 m deep below ground level) with top edge of the earth plate not less than 1.5m below ground level , connected to GI earth wire 4 MM Dia as earthling lead by means bolts and nuts check nuts and washers of galvanized iron and connected to main switch board including watering arrangement with PCC chamber , MS funnel with wire mesh,. CI cover with frame etc including necessary excavation in any type of strata , returning, filling removal of soil outside MD land ,filling of charcoal and salt complete all as shown in electrical plate No. 3 of MES Sch Part I , connected to Earthing test point all as specified and directed on testing on completion. NOTES: 1. The unit rate shall also include for earth work in any type of soil, PCC (1:3:6) type C1 chamber, pre-cast RCC (1:2:4) type B-1 using 20mm graded stone aggregate cover 50mm thick reinforced with TMT bars 8mm dia @ 100mm c/c both ways, funnel with watering pipe 20mm dia medium grade, GI protection pipe light grade 40mm dia and wire mesh complete in addition to item No. 1(a) to (e) of preamble (notes) under sub-heading earthing, specified on Sl. Page Nos. 422 & 423 of SSR Part-II. 2. Earthing lead and GI protection pipe beyond 7.5m will be measured and paid separately.
JD Construction (BID ID -3158821)
M/s K Moorthi (BID ID -3159753)
V KARTHICK (BID ID -3158336)
SKV Engineering (BID ID -3159168)
Sree Tirumala Enterprises (BID ID -3160333)
CHANDER SEKER ENTERPRISE (BID ID -3159235)
CARTWHEEL CONSTRUCTION (BID ID -3158638)
M/S VISHAL CONSTRUCTION (BID ID -3159847)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .