Requiredshould be as indicated in the bid document. Documentary evidence in the form of certified Audited Balance Sheets of relevant periods or a certificate from the Chartered Accountant/Cost Accountant indicating the turnover details for the relevant period shall be uploaded with the bid. In case the date of constitution/incorporation of the OEM is less than 3 year old
Requiredthe average turnover in respect of the completed financial years after the date of constitution shall be taken into account for this criteria. SPECTROPHOTOMETER ( 1 pieces ) Technical Specifications 1/6 * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) TYPE Type of Spectrophotometer UV - VISIBLE UV - VISIBLE Type of Optical System Double Beam Double Beam Monochromator Type Czerny-turner Czerny-turner Detector Type Photodiode Photodiode Spectral Bandwidth Type Fixed Bandwidth Fixed Bandwidth LIGHT SOURCE Light Source Xenon Flash Xenon Flash Diffraction Grating (lines/mm) 1200 1200 Switching of Light Source Automatic Automatic Wavelength Setting And Scanning Automatic Automatic OPTICAL PERFORMANCE Source Wavelength - Minimum 190 190.0 Source Wavelength - Maximum 1100 1100
Required1500
Required2000
Required2500
Required2700
Required3000
Required3200
Required3300
Required1650 Or higher Resolution 1.5 1.5 Wavelength Accuracy (+/-) 0.1 0.1 Bandwidth (nm) 1 1 If variable band width
RequiredSpecify the incremental step value(mm) 0.1 * Scanning Speed (nm/min) 5000 * Focal length (mm) 0 to 49 0 to 49 Photometric measurement modes Transmittance
RequiredAbsorba nce
RequiredConcentration (Wavelength
Requiredtime)
RequiredReflectance Transmittance
RequiredAbsorbance
RequiredConcentration (Wavelength
Requiredtime)
RequiredReflectance Photometric Absorbance (Max) (Abs) (+/-) 3.5 3.5 Photometric Absorbance 0.001 0.001 - 0.001 Or lower 2/6 Accuracy (Max) (+/-) Photometric Transmittance (Max) (+/-) 100 100.0 Photometric Transmittance Accuracy (Max) (+/-) 0.05 0.0 - 0.05 Or lower Photometric Reflectance (Max) (+/-) 100 100.0 Photometric Reflectance Accuracy (Max) (+/-) 0.1 * Stray Light Correction Automatic * Baseline Correction Automatic * GENERIC Display Through PC Through PC Display type LED LED Display Size 19 19.0 - 30.0 Or higher Test result printing Through external printer Through external printer If inbuilt printer
RequiredType of printer N/A N/A Suitable software for connecting PC & Printer Yes * Connectivity USB
RequiredETHERNET * Internal storage(GB) 4 4.0 - 80.0 Or higher Sample switching/selection Automatic * Capacity of Sample holder/Sample Carousel 1 * Mximum Path Length of sample 100 100.0 Number of Cuvettes supplied-inclusive in the scope of supply 10 10 Power Supply 230 V ± 10
Required50 Hz * Any other features/accesories covered in scope of supply - * Spares and Consumables inclusive in the scope of supply No No 3/6 List of Items and Quantity of each item included in the offer - * OPERATING CONDITIONS Minimum Operating Temperature 5 5.0 Maximum Operating Temperature 40 40.0 Operating Humidity (RH) (%) at 40 degree C 80 80.0 WARRANTY Onsite Warranty 1 1.0 Availability of Spares (at extra cost) 7 7.0 Certification Availability of UL/CE Certification as per EN 61010-1:2010 Safety requirements for electrical equipment for measurement
Requiredcontrol
Requiredand laboratory use General requirements Yes Yes Conformance to EMC/EMI as per EN 61326-1:2013 Electrical equipment for measurement
Requiredcontrol and laboratory use Yes Yes Availability of Test Reports from Central Govt/NABL approved/ILAC acredited lab to prove conformity to the specification Yes Yes If yes test report to furnished
Requiredto the buyer on demand Yes * Test Report number and date - * Name and address of the Lab - * * Specifications highlighted in bold are the Golden Parameters. * Bidders may note that In respect of non-golden Parameters
Requiredthe specifications 'Values' chosen by Buyer will generally be preferred over 'Bid requirement ( allowed Values) by the Buyer. 4/6 Additional Specification Documents