Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.1 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹32.4 L+₹1.2 L (3.94%)Rejected-Finance | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹33.4 L+₹2.2 L (7.13%)Rejected-Finance | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹34.0 L+₹2.9 L (9.26%)Rejected-Finance C O SHRI AMRENDER KUMAR YADAV IACHHIPUR SANTOSH NAGAR GORAKHNATH GORAKHPUR UTTAR PRADESH PIN 273015 | GORAKHPUR | UTTAR PRADESH | 273015 | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹34.1 L+₹3.0 L (9.55%)Rejected-Finance WARD NO 40 REGRON KA MOHALLA NEAR RAVI DASS JI MANDIR SHIV BARI BIKANER RAJSTHAN 334001 | BIKANER | RAJASTHAN | 334001 | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
19 Jan 2023, 6:00 pmClosed
GE ARMY SURATGARH
SURATGARH MIL STN
Repair to internal wiring and replacement of electrical fittings in certain MD Accn in MAP and KLP area under GE (Army) Suratgarh at Suratgarh Mil Stn
2022_MES_570769_1
GE (A) SOG - 70/22-23
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
SURATGARH
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE ARMY SURATGARH
₹98,000
Yes
17 Feb 2023
22 Dec 2022
21 Jan 2023
22 Dec 2022
19 Jan 2023
5 Jan 2023
Amount
Taking down carefully or drawing out from conduit, existing copper / aluminium point wiring for light, fan, bell, socket, power point etc complete including fixture and fittings such as switches, sockets, ceiling rose, pendent holder, light fittings, top sheet covers, fan regulators, MCB, DB, earth plug, lamp, street light etc (excluding MS sunken boxes) and making good the disturbed surfaces of wall/ceiling complete all as specified and as directed by Engineer-in-charge.
M&L for Modular point wiring complete with 1.5 Sqmm (nominal cross section area) FRLSH PVC insulated multistranded unsheathed copper conductor cable drawn in and including concealed PVC rigid conduit medium grade 20mm dia, pipe hooks, elbows, junction covers and junction boxes including cutting chases in walls for conduits and for sunken pressed steel terminal boxes and making good the disturbed surfaces of wall with all jointing accessories including provision of pressed steel sunken terminal boxes made of 1.2mm thick pressed steel sheet, 60mm deep of suitable length and painted with red oxide primer for mounting modular switches, sockets, fan regulator including suitable size modular plates fixed flush with wall including 1.5 Sqmm PVC insulated multistranded unsheathed copper conductor wire as earth continuity to common earth and connecting to earth dolly for one light point, fan point, bell point controlled by one switch complete all as specified and directed by Engineer-in-Charge. Make of cable : Havells / Finolex / L&T or equivalent in makes mentioned in Appendix 'A' here-in-after. Make of Conduit :- Polycab / Kalinga / Finolex or equivalent in makes mentioned in Appendix 'A' here-in-after. Note : The quoted rate shall be deemed to included with modular cover plates with frame of any colour and metal flush boxes of suitable size as directed by Engr-in-Charge.
All as per serial item No. 2 here-in-before but for One 3 pin 5 Amp socket outlet on the same board with other switches.
All as per serial item No. 2 here-in-before but for One 3 pin 5 Amp socket outlet on independent board.
All as per serial item No. 2 here-in-before but for One light point controlled by Two 2- way switches.
All as per Srl item No. 2 above, but wiring with cable of cross sectional area 2.5 Sqmm (nominal area) multi-stranded copper conductor FRLSH, PVC sheathed cable 1100 Volts shade for one switch socket combination 6 pin, 5/15 Amps on independent board including 2.5 Sqmm PVC insulated multistranded unsheathed copper conductor wire as earth continuity to common earth dolly.
S&F Modular switch piano 6 Amps single pole, one way, 01 Module complete all as specified and directed by Engineer-in-charge.
S&F Modular switch piano 6 Amps single pole, two way, 01 Module complete all as specified and directed by Engineer-in-charge.
S&F Modular switch piano 16 Amps single pole, one way, 01 Module complete all as specified and directed by Engineer-in-charge.
S&F Modular socket 2 / 3 pin, 6 Amps, 230 volts, combined 2 Module complete all as specified and directed by Engineer-in-charge.
S&F Modular socket 6 pin, 6 / 16 Amps, 230 volts, combined 2 Module complete all as specified and directed by Engineer-in-charge.
S&F Modular bell push, flush type, 5 Amp, 230 Volts grade complete all as specified and directed by Engineer-in-charge.
S&F Modular electronic fan regulator suitable for ceiling fan 2 Module, 1200mm / 1400mm sweep, socket size, rotary type complete all as specified and directed by Engineer-in-charge.
S&F in replacement Modular electronic fan regulator suitable for ceiling fan 2 Module, 1200mm / 1400mm sweep, socket size, rotary type complete all as specified and directed by Engineer-in-charge.
M&L for point wiring complete with 1.5 sqmm (nominal cross sectional area) FRLSH PVC insulated multistandard unsheathed copper conductor cable with colour coding drawn in and including concealed PVC rigid conduit medium grade 20mm dia with accessories such as pipe hooks, elbows, junction box, terminated in existing sunken box and covered with new 3mm thick bakelite plastic laminated sheet top cover fixed flush with wall using brass screws & cup washers including cutting chases in wall for conduits and making good the disturbed surfaces of wall and including 1.5 sqmm PVC insulated unshethed multistandard copper conductor wire as earth continuity to common earth and connecting to earth dolly for one light point, fan point, bell point controlled by one switch complete all as specified and directed by Engineer-in- charge. Make of cable : Havells / Finolex / L&T or equivalent in makes mentioned in Appendix 'A' here-in-after. Make of Conduit :- Polycab / Kalinga / Finolex or equivalent in makes mentioned in Appendix 'A' here-in-after.
All as per serial item No. 15 here-in-before but for One 3 pin 5 Amp socket outlet on the same board with other switches.
All as per serial item No. 15 here-in-before but for One 3 pin 5 Amp socket outlet on independent board.
All as per serial item No. 15 here-in-before but for One light point controlled by Two 2- way switches.
All as per serial item No. 15 here-in-before but for One bell or buzzer point controlled by by one push button on same board with other or independent switches
All as per Srl item No. 15 here-in-before but wiring with cable of cross sectional area 2.5 Sqmm (nominal area) multi-stranded copper conductor FRLSH, PVC unsheathed cable 1100 Volts shade for one switch socket combination 6 pin, 5/15 Amps on independent board including 2.5 Sqmm PVC insulated multistandard unsheathed copper conductor wire as earth continuity to common earth dolly.
S&F switch socket combination 5 pin, 5/15 Amps, 230 volts, flush type complete all as specified and directed by Engineer-in-charge.
S&F socket outlet 3/5 pin, 15 Amps 240 volts, flush type complete all as specified and directed by Engineer-in-charge.
S&F sheet metal plug & socket DB, SP, with a two pin and earth plug with socket, 230 Volts with & including one MCB SP ‘C’ Curve 10 kA, 20 Amps complete all as specified and directed by Engineer-in-charge. Make of DB :- Legrand Cat part No 507811 or equivalent in makes mentioned in Appendix 'A' here-in-after. Make of MCB :- Legrand Cat Part No 408593 or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F switch piano flush button 5 Amps single pole, one way complete all as specified and directed by Engineer-in-charge.
S&F switch piano flush button 5 Amps single pole, two way complete all as specified and directed by Engineer-in-charge.
S&F switch socket combination 3 pin, 5 Amps, 240 volts, flush type complete all as specified and directed by Engineer-in-charge.
S&F socket outlet 3/5 pin, 5 Amps 240 volts, flush type complete all as specified and directed by Engineer-in-charge.
S&F bell push, flush type, 5 Amp, 230 Volts grade complete all as specified and directed by Engineer-in-charge.
S&F electric bell (ding - dong), AC, 230 Volts, Single pole & connecting up complete all as specified and directed by Engineer-in-charge.
S&F ceiling rose surface bakelite 65mmx50mm with two or three terminal complete all as specified and directed by Engineer-in-charge.
S&F electronic fan regulator suitable for ceiling fan 1200mm/1400mm sweep, socket size, rotary type complete all as specified and directed by Engineer-in-charge.
S&F Energy efficient decorative ultra slim, prewired, Maxoled batten for T-8 LED retro lamp, ultra bright, glass shell, glare free, wide angle single/ double side connection retrofit LED tube with G-13 lamp holder/patti 20 watt LED light fitting (Day cool light) including 20 watt LED tube with all accessories prewired fixed on wall / hanging complete all as specified and as directed by Engineer-in-charge. Make :- Havells Cat part No LHFXCENNTN1W020 & LHLDDCXCML8Q020 or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F Energy efficient decorative ultra slim prewired 9 / 10watt (600mm length) LED light fitting (Mirror light) (Day cool light), surface and wall mounted LED batten, extruded aluminium housing with polycarbonate diffuser & integrated electronic driver and all accessories fixed on wall / hanging complete all as specified and as directed by Engineer-in-charge. Make :- Havells Cat part No LUMILINEBS9WLED865S PCWH / Crompton cat part No LCTLN-10-CDL or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F Energy saving 9/10 watt environmental friendly, ultra modern, energy saving, surface mounted, decorative oval bulk head edge-lit LED luminaire comprising of high brightness LEDs, IP 65 protection fixed on wall complete all as specified and as directed by Engineer-in-charge. Make :- Havells Cat part No HEXAFT10WLED857SSY MBOPC / Crompton cat part No LBHE-10-CDL or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F Lamp holder, insulated body with back plate etc complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing LED lamp minimum 3 star rated 9W LED B-22 base complete all as specified and directed by Engr-in-Charge with following specifications (a) Lumen system efficacy of lamp should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 45°C (d) Power factor : Minimum 0.90 (e) CRI : Morethan 80
S&F in replacement Energy efficient decorative round LED surface down light fitting of 18 watt, 6500K lumen output, prewired with complete with all accessories, IP 54 protection connecting up 3 core sheathed copper flexible cable 1.5 sqmm up to light fitting & connecting and testing complete all as specified and as directed by Engineer-in-charge. complete all as specified and as directed by Engineer-in-charge. Make :- Havells / Crompton / Wipro / Philips or equivalent in makes mentioned in Appendix 'A' here-in-after.
Supply, fixing and testing LED Street / Security light fitting of 25 Watt, 5700K - 6500 K (including LED drive and internally prewired) complete with body robust, corrosion resistant, superior finish and without any cracks or through holes, made in a single piece by high pressure die cast aluminum alloy. The luminaries shall be monolithic construction totally enclosed dust and water proof with IP -65 / 66 protection as per IS - 10322-1982(Part -I) with latest amendments and input voltage range 140 - 300 V, AC, frequency 50 - 60 Hz ,P.F should be more than 0.9 with Total Harmonic Distortion THD(I) less than 15% ,cool white colour and lamp starting time should not be more than 10 second including 10 KV surge protection in built or external. Driver should be constant current constant voltage driver. Driver should have high voltage withstanding capacity upto 300 V, AC. Driver should also have double phase protection, no load , open circuit and short circuit protection .LED light fitting should be suitable for ambient temperature from -10 degree Centigrade to 50 degree Centigrade and humidity level 10% to 90 % RH. Covers should be polycarbonate/toughened glass to ensure minimum IP 65 degree protection. Cover should not degrade due to heating and ageing. The efficiency of LED luminaries system shall be more than 100 lumens per watt and must be certified by the LM-79 test report and including connection for street light from pole box with 1.5 Sqmm, 3 core PVC insulated stranded copper conductor FRLSH cable, 1100 Volts grade ISI marked including addition / alteration in bracket (if required) for fixing light fitting complete all as specified and directed by Engineer-in- charge.
Notes for srl Item No 38 :- (a) Tenderer shall submit test report of LED street light fitting from Government accredited test laboratory for LM - 79 and LM - 80 . (b) Contractor has to furnish a replacement warranty of 05 years for LED light fittings complete including lamps from the date of completion of CA. Contractor shall obtain warranty from the manufacturer of product on their letter head and submit the same to deparment alonwith his letter head. The product will be replaced free of cost in the following case :- (i) Manfacturing defects (ii) Failure due to mechanical and electrical impact. (iii) Drop in lumen (or lux at 1 m) below 90% of clamied values of lumen(or lux at 1 m) of the LED /Luminaries. (c) All LED light/luminare must meet the provision laid down in IS - 16101 , 16102 Part -I/II ,16103 Part -I , 16104 ,16105 ,16106 , 16108/2012 and 15885 Part -II / Section 13. (d) Scope of work shall include supply and fixing street light fittings on street light bracket fixed on poles, If street light fitting requires to fixed on existing street light bracket and any addition alterration required in bracket for fixing street light, In that case cost of additional / alteration is included in the unit rate of this item, which also includes needful T & P and required accessories such as 1.5 sqmm, 3 core PVC insulated stranded copper conductor cable for connection from pole box to light fitting etc complete including making connection, testing etc complete .No extra payment is admissible on this account. (e) Light fittings shall be provided with 10 KV surge protection as mentioned in description of item. If 10 KV surge protection is not provided in light fitting for which cat part is mentioned in BOQ. Contractor has to provide light fitting with 10 KV surge protection without any extra cost to department. (f) Contractor shall write CA No on street light fitting with synthetic enamel paint which should be visible from ground level. Cost of the same is included in the unit rate of this item nothing shall be extra paid on this account.
S&F flush mounting factory made SPN DB 8 way, 240 Volt, Single door, IP-43 protection, IK-09 with metal door with 100 Amps copper bus bar, with neutral bar, earth bar and cables ties for cable management fully insulated bus bar complete all as specified and directed by Engineer-in-charge. Make :- Legrand Cat Part No 507611 or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F flush mounting factory made SPN DB 12 way, 240 Volt, Double door, IP-43 protection, IK-09 with metal door with 100 Amps copper bus bar, with neutral bar, earth bar and cables ties for cable management fully insulated bus bar complete all as specified and directed by Engineer-in-charge. Make :- Legrand Cat Part No 507612 or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F MCB 6 to 32 Amps, Single Pole 240 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge. Make :- Legrand Cat Part No 408587 to 408595 or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F MCB 40 Amps, Single Pole & neutral 240 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge. Make :- Legrand Cat Part No 408618 or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F MCB 63 Amps, Single Pole & neutral 240 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge. Make :- Legrand Cat Part No 408620 or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F MCB 100 Amps, double pole 240 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge. Make :- Legrand Cat Part No 408641 or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F MCB 40 Amps, four pole 240 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge. Make :- Legrand Cat Part No 408700 or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F MCB 63 Amps, four pole 240 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge. Make :- Legrand Cat Part No 408702 or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F MCB 100 Amps, four pole 240 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge. Make :- Legrand Cat Part No 408704 or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F flush mounting factory made SPN DB 4 way, 240 Volt, Double door, IP-43 protection, IK-09 with metal door with 100 Amps copper bus bar, with neutral bar, earth bar and cables ties for cable management fully insulated bus bar complete all as specified and directed by Engineer-in-charge. Make :- Legrand Cat Part No 507610 or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F Sub main wiring complete with 2 single core 6 Sqmm (Nominal area) multi stranded copper conductor PVC insulated unsheathed cable FRLSH drawn in and including heavy duty PVC conduit ISI marked not less than 25mm dia concealed including single core multistranded copper conductor 6 Sqmm size cable as earth continuity wire drawn in same conduit complete all as specified and directed by Engineer-in- charge Note : Two runs of 6 Sqmm single core cable and one run of 6 sqmm copper wire earth continuty conductor and conduit with fittings shall be measured as one length.
S&F Sub main wiring complete with 2 single core 4 Sqmm (Nominal area) multi stranded copper conductor PVC insulated unsheathed cable FRLSH drawn in and including heavy duty PVC conduit ISI marked not less than 25mm dia concealed including single core multistranded copper conductor 4 Sqmm size cable as earth continuous wire drawn in same conduit complete all as specified and directed by Engineer-in- charge Note : Two runs of 4 Sqmm single core cable and one run of 4 sqmm copper wire earth continuty conductor and conduit with fittings shall be measured as one length.
M&L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to earth lead of GI wire 4 mm dia (8 SWG) by means of bolts, nuts and washers of the earth wire galvanised iron or steel and thimbles and other end of the earth wire connected to earthing test point and protected by galvanised iron pipe light grade 15mm dia and water pipe 20mm dia GI light grade top of pipe with funnel & wiremesh, and bottom connected to earth plate by slit and two bolts/nuts/washers, PCC chamber in cement concrete (1:2:4) type B-1 and 40mm thick RCC cover, excavation & earth work complete all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009 including taking down old eathing complete all as specified and directed by Engr-in-charge. Notes :- (i) GI wire upto DBs or upto earth test point is included in this item. (ii) Outer edge of earth pit chamber shall be 1.5 metre away from the outer edge of PCC chamber. (iii) Minimum weight of reinforcement for RCC cover shall be 1 KG.
S&F in repair street light bracket made out of 40mm dia GI pipe light grade 1.5m long , bent to shape at 120 degree angle from vertical fixed along pole with and including required number of clamp made out of Flat iron 25mm x 6mm with nuts, bolts ,washers etc. duly painted with two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed by Engineer-in-charge.
Supplying, laying, jointing, commissioning and testing XLPE insulated screened PVC bedded, armoured, heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade of cross sectional area 16 sq mm 2 core confirming to IS-7098 (Part-I-1988) laid in trenches, along poles through pipes etc including taking down old unserviceable cable complete all as specified and directed by Engineer-in-charge. Notes :- (i) Excavation, earth work, sand cushioning, cable protection and GI pipe shall be measured & paid for separately under respective items of BOQ (ii) Road cutting / floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall deemed to be inclusive of the above provisions.
All as per item No 53 above but cable of cross sectional area 16 sq mm 4 core
All as per item No 53 above but cable of cross sectional area 25 sq mm 4 core
Excavation in trenches, not exc 1.5 m wide and n. exc 1.5 m depth, or n exc 10 Sqm on plan and n exc 1.5 m in depth for foundations of poles, struts, stays etc. or laying underground cable and water supply / sewage pipe line etc. in soft / loose soil & getting out including taking out old brick or precast cable cover complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, leveling watering and well ramming in layers n.exc 25 cm in soft/loose soil complete all as specified and directed by Engineer-in-charge.
Removal of excavated soil/ material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and directed by Engineer-in-charge.
M&L for dry sand (Tibba sand) and punning for cushioning to underground cable complete all as specified and directed by Engineer-in-charge Note: - For payment purpose thickness after punning shall be measured.
M & L for brick protection with old size sub class 'B' bricks laid flat, length of bricks across the route of underground cable all as specified and directed by Engineer-in-Charge.
S&F in replacement Galvanized iron tubing, 40mm bore light grade, ISI marked, including all fittings and laid in trenches / under road / drains, fixed to poles / walls with required numbers of clamps made out of 25x3mm flat iron, bolts, nuts and washers for protection of LT electric cable complete all as specified and as directed by Engineer-in-charge. Notes :- (i) Excavation & earthwork shall be measured & paid for separately under respective items of BOQ (ii) Cost of flat iron clamp if required is included in the unit rate of this item. Nothing extra shall be paid on this account.
S&F in replacement switch piano flush button 5 Amps single pole, one way complete all as specified and directed by Engineer-in-charge.
S&F in replacement switch piano flush button 15 Amps single pole, one way complete all as specified and directed by Engineer-in-charge.
S&F in replacement switch socket combination 3 pin, 5 Amps, 240 volts, flush type complete all as specified and directed by Engineer-in-charge.
S&F in replacement switch socket combination 5 pin, 5/15 Amps, 230 volts, flush type complete all as specified and directed by Engineer-in-charge.
S&F in replacement socket outlet 3/5 pin, 15 Amps 240 volts, flush type complete all as specified and directed by Engineer-in-charge.
S&F in replacement Lamp holder, insulated body with back plate etc complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement ceiling rose surface bakelite 65mmx50mm with two or three terminal complete all as specified and directed by Engineer-in-charge.
S&F in replacement electric bell (ding - dong), AC, 230 Volts, Single pole & connecting up complete all as specified and directed by Engineer-in-charge.
S&F in replacement electronic fan regulator suitable for ceiling fan 1200mm/1400mm sweep, socket size, rotary type complete all as specified and directed by Engineer-in-charge.
S&F in replacement flush mounting factory made SPN DB 8 way, 240 Volt, Single door, IP-43 protection, IK-09 with metal door with 100 Amps copper bus bar, with neutral bar, earth bar and cables ties for cable management fully insulated bus bar complete all as specified and directed by Engineer-in-charge. Make :- Legrand Cat Part No 507611 or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F in replacement flush mounting factory made SPN DB 12 way, 240 Volt, Double door, IP-43 protection, IK-09 with metal door with 100 Amps copper bus bar, with neutral bar, earth bar and cables ties for cable management fully insulated bus bar complete all as specified and directed by Engineer-in-charge. Make :- Legrand Cat Part No 507612 or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F in replacement MCB 63 Amps, Single Pole & neutral 240 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge. Make :- Legrand Cat Part No 408620 or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F in replacement MCB 40 Amps, Single Pole & neutral 240 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge. Make :- Legrand Cat Part No 408618 or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F in replacement sheet metal plug & socket DB, SP, with a two pin and earth plug with socket, 230 Volts with & including one MCB SP ‘C’ Curve 10 kA, 20 Amps complete all as specified and directed by Engineer-in-charge. Make of DB :- Legrand Cat part No 507811 or equivalent in makes mentioned in Appendix 'A' here-in-after. Make of MCB :- Legrand Cat Part No 408593 or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F in replacement MCB 6 to 32 Amps, Single Pole 240 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge. Make :- Legrand Cat Part No 408587 to 408595 or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F in replacement MCB 63 Amps, four pole 240 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge. Make :- Legrand Cat Part No 408702 or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F in replacement of MCCB, 100 Amp, 4 Pole, 16KA, 415 volts with fixed thermal magnetic release complete all as specified and directed by Engineer-in-charge. Make :- Legrand DPX-160 Cat Part No 420015 or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F in replacement of MCCB, 125 Amp,4 Pole,16KA, 415 volts with fixed thermal magnetic release complete all as specified and directed by Engineer-in-charge. Make :- Legrand DPX-160 Cat Part No 420016 or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F in replacement Energy efficient decorative ultra slim, prewired, Maxoled batten for T-8 LED retro lamp, ultra bright, glass shell, glare free, wide angle single/ double side connection retrofit LED tube with G-13 lamp holder/patti 20 watt LED light fitting (Day cool light) including 20 watt LED tube with all accessories prewired fixed on wall / hanging complete all as specified and as directed by Engineer-in-charge. Make :- Havells Cat part No LHFXCENNTN1W020 & LHLDDCXCML8Q020 or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F in replacement Energy efficient decorative ultra slim prewired 9 / 10watt (600mm length) LED light fitting (Mirror light) (Day cool light), surface and wall mounted LED batten, extruded aluminium housing with polycarbonate diffuser & integrated electronic driver and all accessories fixed on wall / hanging complete all as specified and as directed by Engineer-in-charge. Make :- Havells Cat part No LUMILINEBS9WLED865 SPCWH / Crompton cat part No LCTLN-10-CDL or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F in replacement Energy saving 9/10 watt environmental friendly, ultra modern, energy saving, surface mounted, decorative oval bulk head edge-lit LED luminaire comprising of high brightness LEDs, IP 65 protection fixed on wall complete all as specified and as directed by Engineer-in-charge. Make :- Havells Cat part No HEXAFT10WLED857SSY MBOPC / Crompton cat part No LBHE-10-CDL or equivalent in makes mentioned in Appendix 'A' here-in-after.
Supply and fixing in replacement LED lamp minimum 3 star rated 9W LED B-22 base complete all as specified and directed by Engr-in-Charge with following specifications (a) Lumen system efficacy of lamp should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 45°C (d) Power factor : Minimum 0.90 (e) CRI : Morethan 80
Supply and fixing in replacement LED lamp minimum 3 star rated 18W LED B-22 base complete all as specified and directed by Engr-in-Charge with following specifications (a) Lumen system efficacy of lamp should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 45°C (d) Power factor : Minimum 0.90 (e) CRI : Morethan 80
Dismantling all electronic meters from the existing panel and refixing in new panel after testing, S&F single pjhase multi meter mounting box (650mm x 450mm x 150mm ) for mounting 04 Nos electronic meter, shockproof and rustproof, termite resistant, cable entry from bottom side, 100% weather proof, pole mounting arrangement, , temper & pilferage proof , fire retardant-class FV-0 as per IS 11731 part-II or V-0 as per UL-94 Make : Sintex Model No GSMB 6545 or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F in replacement Sub main wiring complete with 2 single core 6 Sqmm (Nominal area) multi stranded copper conductor PVC insulated unsheathed cable FRLSH drawn in and including heavy duty PVC conduit ISI marked not less than 25mm dia concealed including single core multistranded copper conductor 6 Sqmm size cable as earth continuity wire drawn in same conduit complete all as specified and directed by Engineer-in- charge Note : Two runs of 6 Sqmm single core cable and one run of 6 sqmm copper wire earth continuty conductor and conduit with fittings shall be measured as one length.
S&F in replacement Sub main wiring complete with 2 single core 4 Sqmm (Nominal area) multi stranded copper conductor PVC insulated unsheathed cable FRLSH drawn in and including heavy duty PVC conduit ISI marked not less than 25mm dia concealed including single core multistranded copper conductor 4 Sqmm size cable as earth continuous wire drawn in same conduit complete all as specified and directed by Engineer-in- charge Note : Two runs of 4 Sqmm single core cable and one run of 4 sqmm copper wire earth continuty conductor and conduit with fittings shall be measured as one length.
Supply, fixing and testing in replacement LED Street / Security light fitting of 25 Watt, 5700K - 6500 K (including LED drive and internally prewired) complete with body robust, corrosion resistant, superior finish and without any cracks or through holes, made in a single piece by high pressure die cast aluminum alloy. The luminaries shall be monolithic construction totally enclosed dust and water proof with IP -65 / 66 protection as per IS - 10322-1982(Part -I) with latest amendments and input voltage range 140 - 300 V, AC, frequency 50 - 60 Hz ,P.F should be more than 0.9 with Total Harmonic Distortion THD(I) less than 15% ,cool white colour and lamp starting time should not be more than 10 second including 10 KV surge protection in built or external. Driver should be constant current constant voltage driver. Driver should have high voltage withstanding capacity upto 300 V, AC. Driver should also have double phase protection, no load , open circuit and short circuit protection .LED light fitting should be suitable for ambient temperature from -10 degree Centigrade to 50 degree Centigrade and humidity level 10% to 90 % RH. Covers should be polycarbonate/toughened glass to ensure minimum IP 65 degree protection. Cover should not degrade due to heating and ageing. The efficiency of LED luminaries system shall be more than 100 lumens per watt and must be certified by the LM-79 test report and including connection for street light from pole box with 1.5 Sqmm, 3 core PVC insulated stranded copper conductor FRLSH cable, 1100 Volts grade ISI marked including addition / alteration in bracket (if required) for fixing light fitting complete all as specified and directed by Engineer-in- charge.
Notes for srl Item No 88 :- (a) Tenderer shall submit test report of LED street light fitting from Government accredited test laboratory for LM - 79 and LM - 80 . (b) Contractor has to furnish a replacement warranty of 05 years for LED light fittings complete including lamps from the date of completion of CA. Contractor shall obtain warranty from the manufacturer of product on their letter head and submit the same to deparment alonwith his letter head. The product will be replaced free of cost in the following case :- (i) Manfacturing defects (ii) Failure due to mechanical and electrical impact. (iii) Drop in lumen (or lux at 1 m) below 90% of clamied values of lumen(or lux at 1 m) of the LED /Luminaries. (c) All LED light/luminare must meet the provision laid down in IS - 16101 , 16102 Part -I/II ,16103 Part -I , 16104 ,16105 ,16106 , 16108/2012 and 15885 Part -II / Section 13. (d) Scope of work shall include supply and fixing street light fittings on street light bracket fixed on poles, If street light fitting requires to fixed on existing street light bracket and any addition alterration required in bracket for fixing street light, In that case cost of additional / alteration is included in the unit rate of this item, which also includes needful T & P and required accessories such as 1.5 sqmm, 3 core PVC insulated stranded copper conductor cable for connection from pole box to light fitting etc complete including making connection, testing etc complete .No extra payment is admissible on this account. (e) Light fittings shall be provided with 10 KV surge protection as mentioned in description of item. If 10 KV surge protection is not provided in light fitting for which cat part is mentioned in BOQ. Contractor has to provide light fitting with 10 KV surge protection without any extra cost to department. (f) Contractor shall write CA No on street light fitting with synthetic enamel paint which should be visible from ground level. Cost of the same is included in the unit rate of this item nothing shall be extra paid on this account.
S&F in replacement modular white cover plate 1 module with screws and nuts complete all as specified and directed by Engineer-in-charge.
S&F in replacement modular white cover plate 2 module with screws and nuts complete all as specified and directed by Engineer-in-charge.
S&F in replacement modular white cover plate 3 module with screws and nuts complete all as specified and directed by Engineer-in-charge.
S&F in replacement modular white cover plate 4 module with screws and nuts complete all as specified and directed by Engineer-in-charge.
S&F in replacement modular white cover plate 6 module with screws and nuts complete all as specified and directed by Engineer-in-charge.
S&F in replacement modular white cover plate 8 module with screws and nuts complete all as specified and directed by Engineer-in-charge.
S&F in replacement modular Metal flush box 1/2 module complete by making hole / place to house box inside wall and finish good distrurbed portion complete all as specified and directed by Engineer-in-charge.
S&F in replacement modular Metal flush box 3 module complete by making hole / place to house box inside wall and finish good distrurbed portion complete all as specified and directed by Engineer-in-charge.
S&F in replacement modular Metal flush box 4 module complete by making hole / place to house box inside wall and finish good distrurbed portion complete all as specified and directed by Engineer-in-charge.
S&F in replacement modular Metal flush box 6 module complete by making hole / place to house box inside wall and finish good distrurbed portion complete all as specified and directed by Engineer-in-charge.
S&F in replacement modular Metal flush box 8 module complete by making hole / place to house box inside wall and finish good distrurbed portion complete all as specified and directed by Engineer-in-charge.
S&F white cover blanking plate 1 module complete all as specified and directed by Engineer-in-charge.
Supplying, laying or passing through pipes, jointing, commissioning and testing PVC insulated stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanized steel wire or tape and over all PVC sheathed 1100 volts grade of cross sectional area 10 sq mm 2 core confirming to IS-7098 (Part-I-1988) including taking down old UNSV pipe complete all as specified and directed by Engineer-in-charge.
Taking down carefully existing storage type geyser 25/50 ltr capacity and disconnection of inlet and outlet water connection taking out all accessories inside the body removing nut bolt from base plate assembly cleaning of inside of stainless steel/copper tank with the help of brush, checking any leakage testing of each unserviceable parts/spairs for its functioning and replacement of unserviceable parts, re fixing the same after cleaning and making proper functioning to maintain proper water temperature complete all as specified and directed by Engineer-in-Charge. Note: The accessories/spare parts such as base plate assembly, insulation material, outer shell & stainless steel tank which are required to be replaced shall be measured and paid for separately as "Supply only" under respective items of BOQ.
S&F in replacement heating element of capacity 1.5 KW including rubber washer, bolts, clamps etc for geysers of 25 ltr capacity of any type & make complete all as specified and as directed by Engineer-in-charge. Make : Dasspass / Racold / Bajaj
S&F in replacement heating element of capacity 2 KW including rubber washer, bolts, clamps etc for geysers of 50 ltr capacity of any type & make complete all as specified and as directed by Engineer-in-charge. Make : Dasspass / Racold / Bajaj
S&F in replacement thermostatic switch (ISI marked) of range 0˚C to 80˚C suitable for 25/50 ltr capacity geyser complete all as specified and as directed by Engineer-in-charge. Make : Dasspass / Racold / Bajaj
Supply only base plate assembly consisting of inlet and outlet CP brass pipe, thermostatic, CP brass pipe, drain plug, pressure release valve spring controlled and rubber gasket, bolts, washers etc as per existing pattern suitable for 25 ltr capacity geyser complete all as specified and as directed by Engineer-in-charge.
Supply only base plate assembly consisting of inlet and outlet CP brass pipe, thermostatic, CP brass pipe, drain plug, pressure release valve spring controlled and rubber gasket, bolts, washers etc as per existing pattern suitable for 50 ltr capacity geyser complete all as specified and as directed by Engineer-in-charge.
Supply only glass wool between the inner and outer cover for geysers complete all as specified and as directed by Engineer-in-charge.
S&F in replacement indicating lamp round/rectangular type as per existing suitable for 25/50 ltr capacity geysers working on 230 volt AC supply complete all as specified and as directed by Engineer-in-charge.
Supply only outer shell as per existing size and shape made of 20 gauge MS sheet suitable for 25 ltr capacity geyser of any make including rubber ring and screws complete all as specified and as directed by Engineer-in-charge.
Supply only outer shell as per existing size and shape made of 20 gauge MS sheet suitable for 50 ltr capacity geyser of any make including rubber ring and screws complete all as specified and as directed by Engineer-in-charge.
Supply only stainless steel tank of 25 ltr capacity geysers as per existing size and shape complete all as specified and as directed by Engineer-in-charge.
Supply only stainless steel tank of 50 ltr capacity geysers as per existing size and shape complete all as specified and as directed by Engineer-in-charge.
S&F in replacement fusible safety brass plug as per existing suitable for 25/50 ltr capacity geysers complete all as specified and as directed by Engineer-in-charge.
S&F in replacement 600mm long PVC connection suitable for 15 mm bore with PTMT nuts on both sides complete all as specified and directed by Engineer-in-charge.
S&F in replacement PVC insulated flexible copper conductor cable 3 core of size 70/0.0076 (ISI marked) complete all as specified and as directed by Engineer-in-charge.
S&F in replacement plug top 3 pin, 15 Amp, 230 volt AC complete all as specified and as directed by Engineer-in-charge.
M&L for grouting of 'T' type bolt in PCC (1:2:4), 6" / 150mm long and 5/8" dia with nut and washer after removing / taking out the old bolts etc complete all as specified and as directed by Engineer-in-charge.
S&F in repair of zebra fastner of size 12x100mm complete all as specified and as directed by Engineer-in-charge. ----------------------------------------------------------------------------- Note :- A sum of Rs. 229391/- will be deducted on account of credit for dismantled/ demolished / taken down material. Please refer details on Srl Page No. 33 & 34 (Schedule of Credit) of Tender documents.
Gupta Suppliers
AK CONSTRUCTION
SHIVA BUILDERS
B.K. ROY & SONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .