Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹19.8 LAccepted-AOC 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NORTH | DELHI | 110006 | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹22.1 L+₹60,315 (2.81%)Rejected-Finance | L-2 | Rejected-Finance L-2 | |
| 3 | L-3₹22.8 L+₹1.3 L (6.29%)Rejected-Finance PLOT NO 32 FF SHIVAJI ENCLAVE NEW DELHI 110027 | NEW DELHI | NEW DELHI | DELHI | 110027 | L-3 | Rejected-Finance L-3 | |
| 4 | L-4₹25.7 L+₹4.2 L (19.6%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 IP EXTN PARPARGANJ DELHI 110092 | EAST | DELHI | 110092 | L-4 | Rejected-Finance L-4 |
Tender Value
₹29.6 L
EMD Value
₹59,200
Closing Date
17 Jul 2024, 6:00 pmClosed
GE (AF) FARIDABAD
GE (AF) FARIDABAD
SPECIAL REPAIR/REPLACEMENT TO RUSTED OUT GI/CI PIPE, OTHER ALLIED WORKS AT AF STN FARIDABAD UNDER AOR OF GE (AF) FARIDABAD
2024_MES_660126_1
GE (FBD)/AF-10/2024-2025
Open Tender
Civil Works - Water Works
Item Rate
180 days
Faridabad
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹59,200
Yes
16 Nov 2024
15 Jun 2024
19 Jul 2024
15 Jun 2024
17 Jul 2024
29 Jun 2024
15 Jun 2024 - 22 Jun 2024
Amount
Excavation in trenches n exc 1.5 m wide & n exc 1.5 mtr deep in soft/lose soil for taking out pipe & laying of pipe & getting out for diverting of pipe line complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, leveling, watering & well ramming in layers n. exc 25 cm thick complete all as specified and directed by Engineer-in-Charge.
Removal of excavated soil to a distance not exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-Charge.
Taking down in repairs the following sizes of bore dia steel tubing and connections, complete all as specified and directed by Engineer-in-Charge.
All as per item No 04 above but 50 mm bore
All as per item No 04 above but 40 mm bore
All as per item No 04 above but 25 mm bore
All as per item No 04 above but 20 mm bore
All as per item No 04 above but 15 mm bore
Supplying and laying of CPVC pipes SDR 13.5 & Plain CPVC SDR 11 incl necessary fittings in trenches complete all as specified and directed by Engineer-in-Charge.
All as per item No 10 above but 50 mm bore
All as per item No 10 above but 40 mm bore
All as per item No 10 above but 25 mm bore
Supply and Laying in trenches galvanised steel water tubing ,medium grade including necessary fittings such as GI bends,Tees,Union etc complete and connecting to water supply pipe line after taking out existing old/rusted out steel tubing and connections pipe line of following sizes complete all as specified and directed by Engineer-in-Charge:-
All as per item No 14 above but 40 mm bore
All as per item No 14 above but 25 mm bore
Supply and Laying 3- layer PP-R Polypropylene random copolymer)concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene including random fittings fixed complete to walls, ceilings or in floors etc pipe line of following sizes complete all as specified and directed by Engineer-in-Charge:-
All as per item No 17 above but 25 mm bore
All as per item No 17 above but 20 mm bore
All as per item No 17 above but 16 mm bore
Supply and fixing in repairs sluice valve cast iron body class PN 1.6 marked both ends flanged with Brass spindle and Brass check nuts with cast iron hand wheel including jointing material like rubber insulation sheet 3 mm thick,bolts ,nuts and fixed to pipe line,after and including taking out old unserviceable one for following sizes complete all as specified and directed by Engineer-in-Charge:-
All as per item No 21 above but 150 mm bore
All as per item No 21 above but 100 mm bore
M&L Fix PP-R Gate valves (brass insert) as per requirement of the site after and including taking out old unserviceable of the following sizes complete all as specified and directed by Engineer-in-Charge:-
All as per item No 21 above but 50 mm bore
All as per item No 21 above but.25 mm bore
All as per item No 21 above but 20 mm bore
Dismantling unserviceable old valve chambers of any size and keeping aside old materials such as CI covers, angle iron frames and bricks etc complete all as specified and directed by Engineer-in-Charge
M&L for costruction of valve chamber of brick masonry built in CM(1:4) with MS covers 3 mm thick and locking arrangement including excavaton and earth works in any type of soil PCC (1;4;8) type D2 for foundation PCC bed/coping in cement concrete (1:2:4) type B1 plastering 15 mm thick with Cm 1:4 painting with one coat of bituminous black paint on all steel surface for the following sizes chambers complete all as specified and directed by Engineer-in-Charge :-
All as per item No 29 above but 1350 mm x 1000 mm x 1200 mm internal dimension
All as per item No 29 above but 900 mm x 900 mm x 1000 mm internal dimension
All as per item No 29 above but 900 x 600 x 1000 mm internal dimension
Taking up cast iron water mains,200 mm bore dia (incl all fittings) with spigot and socket end and lead joint incl burning out joint complete all as specified and directed by Engineer-in-Charge
All as per item No 33 above but 150 mm bore dia
Supply and lay pipe ductile Iron , S/S including specials, Class “K-7” ,150 mm (6”) dia bore ISI marked with all fittings laid in trenches or fixed to wall etc complete all as specified and directed by Engineer-in-Charge
Supply and lay pipe ductile Iron , S/S including specials, Class “K-7” ,200 mm (8”) dia bore ISI marked with all fittings laid in trenches or fixed to wall etc complete all as specified and directed by Engineer-in-Charge
M&L for DI Pipe fitting (Tee,bends any type,radius and angle) tapers any type (straight,bend,increasing, decreasing or double sockets etc.) junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs of all size dia DI pipe complete all as specified and directed by Engineer-in-Charge
M&L for earthing in repair complete with galvanized mild steel earth plate electrode of size 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 mtr below ground level) with top edge of earth plate not less than 1.5 mtr below ground level connected to galvanized iron strip of size 32mm x 6mm as earthing lead by means of nuts, bolts, thimbles, check nuts, washers of GI or steel, PCC (concrete chamber) shall be size 300mm x 300mm x 300mm (internal dimension) using PCC 1:2:4, type B-1, using 20mm graded stone aggregate internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge of 22 gauge (0.68mm) 8 mesh per liner inch, 80mm thick RCC cover B-1, size 320mm x 320mm, made out with RCC 1:2:4, type B-1, using 20mm graded stone aggregate, reinforced with four Nos 8mm dia TMT bars @ 80mm centre to centre, both ways and charcoal dust and common salt all as shown in Electrical plate No 3 of SSR Part – I (2009) and specified including 40mm dia GI light grade pipe as protection pipe and watering pipe shall be 20mm bore GI medium grade including necessary excavation and earth work & connection the earthing to an earthing test point as specified and directed by Engineer-in-Charge.
M&L RO membrane HM 8040-BWE-400 complete all as specified and directed by Engineer-in-Charge
M&L RO membrane HM 4040-BWE-400 complete all as specified and directed by Engineer-in-Charge
M&L 8" end cap assy end port with L key clamp, 300 PSI complete all as specified and directed by Engineer-in-Charge
M&L 4" end cap assy endport with key clamp, 300 PSI complete all as specified and directed by Engineer-in-Charge
Supply & fix of STD Cartridge filter 2.5" dia x 20" long, 5 Micron complete all as specified and directed by Engineer-in-Charge
Supply & fix of Jumbo Cartridge filter 4.5" dia x 20" long, 5 Micron complete all as specified and directed by Engineer-in-Charge
Supply,install and commissioning mono block centrifugal pump heavy 3 HP of pipe size 50mmx50mm with copper winding and maximun flow rate 22000 ltrs/hour complete all as specified and directed by Engineer-in-Charge
Supply and install submersible pump , rating 12.5 HP, voltgae rating 440 volts, outlet 50 mm, head range 148-63 meter 3 phase suitable for 150 mm borewell radial flow complete all as specified and directed by Engineer-in-Charge
M&L Anti scalant suitable for preventing formation of calcium carbonate and calcium sulphate and fouling by silica complete all as specified and directed by Engineer-in-Charge
Supply and fix 100 liter PE/FRP Tank with PE/FRP lid & Level guage and ferrules including waters piping works for inlet and out let complete all as specified and directed by Engineer-in-Charge
S&F chemical Dozing pump,0.5 HP 6 LPH,5.5 BAR suitable for commercial RO water purifier as existing sample including testing and commissioning complete all as specified and directed by Engineer-in-Charge
laxmi enterprises (BID ID -3063734)
Singh Associates (BID ID -3051196)
Saini Enterprises (BID ID -3055097)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .