| 1 | L1₹3.6 LAccepted-AOC | ₹3.6 L | L1 | Accepted-AOC AOC |
| 2 | L2₹3.6 LRejected-Finance NUTANCHATI BHOWMIK GATE BANKURA | BANKURA | WEST BENGAL | 713142 | ₹3.6 L | L2 | Rejected-Finance Rejected |
| 3 | L3₹4.0 LRejected-Finance | ₹4.0 L | L3 | Rejected-Finance Rejected |
| Sl No | Description | Qty | Unit | PRADIP KUMAR DHABAL L2 | Allied Concern L1 | RS SYSTEMS AND PROJECTS L3 |
|---|---|---|---|---|---|---|
| 1.00 | Supply & fixing close type of 415V, 100 A , 50KA , 4-Pole MCCB with Thermal - Magnetic release incl speader terminals with necy. inter connection by suitable copper bars as per direction of E.I.C .( Make:-L&T Cat no-SK90484) | 1 | Each | 12,541 ₹12,541 | 12,541 ₹12,541 | 12,550 ₹12,550 |
| 2.00 | Supplying of 1.1 KV Grade following sizes Al. Armoured PVC/ XLPE Cable ( Make : Havells/ Glostar/ KEI/PWD Approved ) as per direction of EIC. 4 core 95 sqmm (from SSB Sub station to MGPs) | 247 | Mtr | 1,090 ₹2,69,230 | 1,086 ₹2,68,242 | 1,205 ₹2,97,635 |
| 3.00 | Laying of one No. cable above 35 sqmm and upto 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed. | 212 | Mtr | 216 ₹45,792 | 216 ₹45,792 | 230 ₹48,760 |
| 4.00 | Laying of one cable upto 150 sqmm through existing covered masonry trench incl. taking out RC covers, setting them in order, mending good the damages filling the trench with fine dry sand incl. supplying sand. | 35 | Mtr | 129 ₹4,515 | 129 ₹4,515 | 150 ₹5,250 |
| 5.00 | Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 mm above 150 mm. thick | 5 | Cu Mtr | 1,689 ₹8,445 | 1,689 ₹8,445 | 1,700 ₹8,500 |
| 6.00 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : 4 core 95 sq mm | 2 | Set | 293 ₹586 | 293 ₹586 | 300 ₹600 |
| 7.00 | Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials 4 core 95 sq mm | 2 | Set | 389 ₹778 | 389 ₹778 | 425 ₹850 |
| 8.00 | Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required 50 mm dia | 6 | Mtr | 414 ₹2,484 | 414 ₹2,484 | 415 ₹2,490 |
| 9.00 | Excavation of soil for installation of Earth Electrode and filling & ramming as to GS. For morrum soil | 4 | Cu Mtr | 358 ₹1,432 | 358 ₹1,432 | 400 ₹1,600 |
| 10.00 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level & restoring surface duly rammed (:For Morrum Soil ISI-Medium GI pipe as to GS. By ISI -Medium GI pipe | 2 | Set | 1,713 ₹3,426 | 1,713 ₹3,426 | 1,900 ₹3,800 |
Tender Value
Refer Docs
EMD Value
₹7,270
Closing Date
21 Mar 2024, 10:55 amClosed
AE/BMCESD/PWD
Kenduadihi, Gobindanagar Hospital campus, Bankura-722102
Arrangement of Electrical Power Source at Manifold Room (MGPs) under Bankura Sammilani Medical College and Hospital in Bankura.
2024_WBPWD_686726_1
WBPWDTE/ AE /BMCESD /NIQ-55/ Q of 2023-24
Open Tender
ELECTRICAL WORKS ORG
14 days
AE/BMCESD/BANKURA
Please refer Tender documents.
3 documents required · 3 mandatory
₹7,270
Yes
24 Jun 2026
15 Mar 2024
23 Mar 2024
15 Mar 2024
21 Mar 2024
15 Mar 2024
Amount
Supply & fixing close type of 415V, 100 A , 50KA , 4-Pole MCCB with Thermal - Magnetic release incl speader terminals with necy. inter connection by suitable copper bars as per direction of E.I.C .( Make:-L&T Cat no-SK90484)
Supplying of 1.1 KV Grade following sizes Al. Armoured PVC/ XLPE Cable ( Make : Havells/ Glostar/ KEI/PWD Approved ) as per direction of EIC. 4 core 95 sqmm (from SSB Sub station to MGPs)
Laying of one No. cable above 35 sqmm and upto 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed.
Laying of one cable upto 150 sqmm through existing covered masonry trench incl. taking out RC covers, setting them in order, mending good the damages filling the trench with fine dry sand incl. supplying sand.
Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 mm above 150 mm. thick
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : 4 core 95 sq mm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials 4 core 95 sq mm
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required 50 mm dia
Excavation of soil for installation of Earth Electrode and filling & ramming as to GS. For morrum soil
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level & restoring surface duly rammed (:For Morrum Soil ISI-Medium GI pipe as to GS. By ISI -Medium GI pipe
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe as to GS.
Extra for treatment of soil by using salt & charcoal or coke for plate electrode
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required
PRADIP KUMAR DHABAL
RS SYSTEMS AND PROJECTS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid