Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.2 LAccepted-AOC MOHALLA KAMA KHAN WARD NO 07 HOUSE NO 88 DISTT POONCH J K | L1 | Accepted-AOC L1 | |
| 2 | L2₹38.5 L+₹2.3 L (6.43%)Rejected-Finance | L2 | Rejected-Finance Other than L1 Bidder | |
| 3 | L3₹38.6 L+₹2.5 L (6.84%)Rejected-Finance | L3 | Rejected-Finance Other than L1 Bidder | |
| 4 | L4₹48.1 L+₹11.9 L (33.0%)Rejected-Finance 05 MR PRASHANT DESHMUKH PLOT NO 05 SHUBHALAKSHMI APARTMENT ADHYAPAK LAYOUT HINGNA T POINT NAGPUR 440036 MH NAGPUR | NAGPUR | MAHARASHTRA | 440036 | L4 | Rejected-Finance Other than L1 Bidder |
| Sl No | Description | Qty | Unit | M/S PARSHOTAM KUMAR GUPTA L2 | M/S KEWAL KRISHAN SANJEEV KUMAR VAID L3 | JAMWAL CONSTRUCTION CO L1 | GLOBAL POWER SYSTEMS L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | Supply, installation, testing and commissioning of Servo controlled voltage stabilizer (confirming to BIS 9815 (Part-1) 1994, reaffirmation 2019 latest version) Three phase, four wire (RYBN), 50 Hz, Naturally Oil cooled, outdoor, unbalanced type, cooper wound, metallic body duly power coated with lifting Hooks two nos, digital display type, relay free smooth and silent operation with 1st filling of Transformer oil up to level having following specification:-
(a) Capacity 150 KVA
(b) Type - Suitable for unbalanced load and unbalanced input
(c) Input voltage -360V-480V, Input frequency 50 Hz
(d) Output voltage - stabilized at any deigned/ desired voltage 415/+-1%
(e) Rated frequency - 50 Hz
(f) Wave form distortion - Nil
(g) Response time - not to exceed 20 milli seconds
(h) Sensitivity - (+/-) 1%
(j) Rate of correction - Not less than 6 Volt/second between phase and neutral
(k) Efficiency - more than 95%
(l) Type of load - three phase, unbalanced type
(m) Metering - Digital display Voltmeter/Ammeter with multi-functional meter
(n) Operating temperature - For indoor use upto max ambient temp + 55°C
(o) Dimmer rating - 200 Amp
(p) Dimension of tanks - as per OEM design
(q) Oil capacity- as per OEM design | 1 | Each | 5,50,000 ₹5,50,000 | 6,00,000 ₹6,00,000 | 7,00,000 ₹7,00,000 | 5,00,000 ₹5,00,000 Lowest |
| 1.01(r) Class of insulation - Class F (s) Mode of operation Automatic/manual (t) Winding Temperature rise - Max 55°C (10°C above operating temp) (u) Transformer oil -IS 335 marked (v) Core-CRGO M4 Grade/CRNO (Cold Roll Grain Oriented)/ (Cold Rolled Non-Oriented) (w) Auto transformer (Variac) -100 percent Copper wound Electrolytic Grade (x) Losses - As per IS Norms (y) Power Factor - Not less than 0.95 (z ) Protection - (i) Over load protections (ii) Short Circuit protections (iii) High/Low voltage cut off (iv) By pass arrangement in case of Emergency (v) Single phase sequence change /phase fail protection (vi) Earth fault protection (aa) Standard Fitting & Accessories e.g Marking plate, lifting lugs, CI Rollers, Earthing Terminals, cable box including suitable platform as reqd on site complete all as as specified & directed. | |||||||
| 2.00 | Supply, installation, commissioning and testing of Silent Diesel Engine Generating Set comprising of diesel engine liquid- cooled (latest IS and CPCB- Norms ) & alternator, of output capacity not less than 160 KVA at site (DG Set to be installed at HAA 950m above MSL and capacity of DG set shall be selected, so as to deliver 160 KVA in all adverse conditions) 3 phase, 4 wire, 415 V, 50 Hz., 0.8pf at 1500 RPM, with control panel having all necessary switch gears for automatic starting on main failure (AMF Panel), both coupled and aligned on a common base frame complete with standard accessories like MS Fuel tank (having the minimum fuel capacity for running of DG set continously for 12 hours), AVM Pads fitted on base frame, Control Panel with digital measurement devices, alongwith accoustic enclosure with the confirmination of latest BS/IS and complete in all respects Including lubricating oil filled in engine, DG Set Manual comprising of following complete as as specified:-
Prime Mover : Prime mover suitable for driving alternator 160 KVA Capacity having the suitable BHP at 1500 RPM for rated output for alternator in accordance with latest BS/IS Specification with electric starting device with all standard fittings and suitable capacity of lead acid maintenance free battery of 12 Volts as per manufracturer -01 nos with Battery and Charger Engine over speed safety mechanism shall be incorporated. The engine shall be equipped with standard fittings as per manufacture's recommendations. | 1 | Each | 20,87,000 ₹20,87,000 | 24,50,000 ₹24,50,000 | 19,50,000 ₹19,50,000 Lowest | 23,00,000 ₹23,00,000 |
| 2.01Engine Control Panel : (a) All relevant parameters shall be conventionally displayed on complete panel thereby providing easy monitoring of lub oil, pressure, Coolant Temperature, Battery charging, Ammeter, RPM, Hour meter and starting switch etc. (b) AMF Panel with Bye Pass arrangement for Main and DG Both supply, internal wiring and power contactors suitable for 160 KVA generator set, all as per manufacturer's recommendation. Bye Pass arrangement Main & DG set Supply along with all the parameters and accessories as per manufacturer recommendation and CPRI Approved & as per relevant IS. Fuel Tank : Fuel Tank of 12 hours capacity will be installed as per the manufacturer's requirement including all necessary pipe connections from fuel tank to engine and over flow from engine to tank. | |||||||
| 2.02Engine Alternator Engine Alternator of capacity 160 KVA output 3 Phase 50 HZ 415 Volts 4 wire AC supply 0.8 Power Factor at 1500 RPM self regulated self excised screen protected and drip type, insulation class 'H' continously rated brush less type conforming to relevant BS/ IS code as per current manufacturing shedule of standard manufacturer. Engine Alternator shall be mounted on specially designed base plate of rigid welded constructions with anti vibraton pads. The DG Set shall be placed on foundation including necessary civil works as per the manufacturer's recommendations/site requirement. The output of alternator not less than 160 KVA in all adverse conditiones, as the DG set to be installed at HAA 950 m above MSL. Note:- (a) The unit rate shall deemed to include the cost of Diesel and lubrication required for testing and commissioning of DG Set as per department procedure and shall be arranged by contractor. (b) Extenssion of exhaust pipe for DG set along with standerd accessories like flange, nut bolts , asbestous rope etc. shall be provided by the contractor and the cost of the same shall be included in the unit rate quoted by contractor. (c) Cost of foundation and necessary civil works as per the manufacturer's recommendations/site requirement shall be incuded in the unit rate quoted by the contractor. | |||||||
| 3.00 | Supply, installation commissioning and testing of transformer, step down 11 KV/0.433 KVA complete, out door /indoor , copper wound of capacity 160 KVA. NOTE : The unit rate includes Construction of platform suitable for transformer of size 4m x 3m x 1.2m high (external size) from ground level and 30cm below GL, with burnt brick construction in wall and steps, XPM fencing with angle iron post including gate with locking arrangement, PCC (1:5:10) type E-2 in foundation, brickwork in cement mortar (1:4), 10mm thick rendering in cement mortar (1:4) to walls, 50mm thick PCC (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in flooring, 40mm thick PCC (1:2:4) type B-1 on steps, painting to XPM fencing with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and shown in drawings. all connections and carrying out all routine tests before commissioning, complete all as specified and directed. | 1 | Each | 8,45,000 ₹8,45,000 | 3,00,000 ₹3,00,000 Lowest | 5,50,000 ₹5,50,000 | 12,00,000 ₹12,00,000 |
| 4.00 | Supply and fixing of Lightning arrestors (set of three) metal oxide surge type (ZnO) complete with all fittings transmission class discharge capacity 65 Kilo Amps suitable for 11000 volts complete all as specified and as directed. | 1 | Set of three | 2,000 ₹2,000 | 5,000 ₹5,000 | 500 ₹500 Lowest | 15,000 ₹15,000 |
| 5.00 | Supply , laying and testing XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor rating 11000 volts grade of size 95 Sqmm 3 core laid in trenches or passing through pipes/ducts or fixed to walls/poles complete all as specified. (Earth work, brick protection and sand cushioning shall be measured and paid for separately). | 70 | Rm | 800 ₹56,000 | 1,500 ₹1,05,000 | 700 ₹49,000 Lowest | 1,500 ₹1,05,000 |
| 6.00 | Supply , laying and testing XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 95 Sqmm 3.5 core laid in trenches or passing through pipes/ducts or fixed to walls/poles complete all as specified. (Earth work, brick protection and sand cushioning shall be measured and paid for separately). | 100 | Rm | 500 ₹50,000 | 300 ₹30,000 Lowest | 650 ₹65,000 | 800 ₹80,000 |
| 7.00 | Supply , laying and testing XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 06 Sqmm 2.0 core laid in trenches or passing through pipes/ducts or fixed to walls/poles complete all as specified. (Earth work, brick protection and sand cushioning shall be measured and paid for separately). | 40 | Rm | 50 ₹2,000 Lowest | 300 ₹12,000 | 200 ₹8,000 | 150 ₹6,000 |
Tender Value
₹35.7 L
EMD Value
₹71,380
Closing Date
11 Mar 2026, 6:00 pmClosed
CWE Rajouri
HQ CWE Rajouri, C/o 56 APO
PROVN OF TRANSFORMER, DG SET, SERVO STABLIZER ALONGWITH ALLIED SERVICES FOR OXYGEN GENERATION PLANT AT 425 FD HOSPITAL UNDER GE 881 EWS
2025_MES_746377_2
CWE/PNH-80/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE 881 EWS
As per tender documents
8 documents required · 8 mandatory
₹500
Yes
GE 881 EWS
₹71,380
Yes
10 Apr 2026
25 Feb 2026
18 Mar 2026
25 Feb 2026
11 Mar 2026
4 Mar 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, installation, testing and commissioning of Servo controlled voltage stabilizer (confirming to BIS 9815 (Part-1) 1994, reaffirmation 2019 latest version) Three phase, four wire (RYBN), 50 Hz, Naturally Oil cooled, outdoor, unbalanced type, cooper wound, metallic body duly power coated with lifting Hooks two nos, digital display type, relay free smooth and silent operation with 1st filling of Transformer oil up to level having following specification:-
(a) Capacity 150 KVA
(b) Type - Suitable for unbalanced load and unbalanced input
(c) Input voltage -360V-480V, Input frequency 50 Hz
(d) Output voltage - stabilized at any deigned/ desired voltage 415/+-1%
(e) Rated frequency - 50 Hz
(f) Wave form distortion - Nil
(g) Response time - not to exceed 20 milli seconds
(h) Sensitivity - (+/-) 1%
(j) Rate of correction - Not less than 6 Volt/second between phase and neutral
(k) Efficiency - more than 95%
(l) Type of load - three phase, unbalanced type
(m) Metering - Digital display Voltmeter/Ammeter with multi-functional meter
(n) Operating temperature - For indoor use upto max ambient temp + 55°C
(o) Dimmer rating - 200 Amp
(p) Dimension of tanks - as per OEM design
(q) Oil capacity- as per OEM design | 1 | Each | - | - |
| 1.01 | (r) Class of insulation - Class F
(s) Mode of operation Automatic/manual
(t) Winding Temperature rise - Max 55°C (10°C above operating temp)
(u) Transformer oil -IS 335 marked
(v) Core-CRGO M4 Grade/CRNO (Cold Roll Grain Oriented)/ (Cold Rolled Non-Oriented)
(w) Auto transformer (Variac) -100 percent Copper wound Electrolytic Grade
(x) Losses - As per IS Norms (y) Power Factor - Not less than 0.95
(z ) Protection - (i) Over load protections
(ii) Short Circuit protections
(iii) High/Low voltage cut off
(iv) By pass arrangement in case of Emergency
(v) Single phase sequence change /phase fail protection
(vi) Earth fault protection
(aa) Standard Fitting & Accessories e.g Marking plate, lifting lugs, CI Rollers, Earthing Terminals, cable box including suitable platform as reqd on site complete all as as specified & directed. | - | - | - | - |
| 2 | Supply, installation, commissioning and testing of Silent Diesel Engine Generating Set comprising of diesel engine liquid- cooled (latest IS and CPCB- Norms ) & alternator, of output capacity not less than 160 KVA at site (DG Set to be installed at HAA 950m above MSL and capacity of DG set shall be selected, so as to deliver 160 KVA in all adverse conditions) 3 phase, 4 wire, 415 V, 50 Hz., 0.8pf at 1500 RPM, with control panel having all necessary switch gears for automatic starting on main failure (AMF Panel), both coupled and aligned on a common base frame complete with standard accessories like MS Fuel tank (having the minimum fuel capacity for running of DG set continously for 12 hours), AVM Pads fitted on base frame, Control Panel with digital measurement devices, alongwith accoustic enclosure with the confirmination of latest BS/IS and complete in all respects Including lubricating oil filled in engine, DG Set Manual comprising of following complete as as specified:-
Prime Mover : Prime mover suitable for driving alternator 160 KVA Capacity having the suitable BHP at 1500 RPM for rated output for alternator in accordance with latest BS/IS Specification with electric starting device with all standard fittings and suitable capacity of lead acid maintenance free battery of 12 Volts as per manufracturer -01 nos with Battery and Charger Engine over speed safety mechanism shall be incorporated. The engine shall be equipped with standard fittings as per manufacture's recommendations. | 1 | Each | - | - |
| 2.01 | Engine Control Panel :
(a) All relevant parameters shall be conventionally displayed on complete panel thereby providing easy monitoring of lub oil, pressure, Coolant Temperature, Battery charging, Ammeter, RPM, Hour meter and starting switch etc. (b) AMF Panel with Bye Pass arrangement for Main and DG Both supply, internal wiring and power contactors suitable for 160 KVA generator set, all as per manufacturer's recommendation. Bye Pass arrangement Main & DG set Supply along with all the parameters and accessories as per manufacturer recommendation and CPRI Approved & as per relevant IS.
Fuel Tank :
Fuel Tank of 12 hours capacity will be installed as per the manufacturer's requirement including all necessary pipe connections from fuel tank to engine and over flow from engine to tank. | - | - | - | - |
| 2.02 | Engine Alternator
Engine Alternator of capacity 160 KVA output 3 Phase 50 HZ 415 Volts 4 wire AC supply 0.8 Power Factor at 1500 RPM self regulated self excised screen protected and drip type, insulation class 'H' continously rated brush less type conforming to relevant BS/ IS code as per current manufacturing shedule of standard manufacturer. Engine Alternator shall be mounted on specially designed base plate of rigid welded constructions with anti vibraton pads. The DG Set shall be placed on foundation including necessary civil works as per the manufacturer's recommendations/site requirement. The output of alternator not less than 160 KVA in all adverse conditiones, as the DG set to be installed at HAA 950 m above MSL.
Note:-
(a) The unit rate shall deemed to include the cost of Diesel and lubrication required for testing and commissioning of DG Set as per department procedure and shall be arranged by contractor.
(b) Extenssion of exhaust pipe for DG set along with standerd accessories like flange, nut bolts , asbestous rope etc. shall be provided by the contractor and the cost of the same shall be included in the unit rate quoted by contractor.
(c) Cost of foundation and necessary civil works as per the manufacturer's recommendations/site requirement shall be incuded in the unit rate quoted by the contractor. | - | - | - | - |
| 3 | Supply, installation commissioning and testing of transformer, step down 11 KV/0.433 KVA complete, out door /indoor , copper wound of capacity 160 KVA. NOTE : The unit rate includes Construction of platform suitable for transformer of size 4m x 3m x 1.2m high (external size) from ground level and 30cm below GL, with burnt brick construction in wall and steps, XPM fencing with angle iron post including gate with locking arrangement, PCC (1:5:10) type E-2 in foundation, brickwork in cement mortar (1:4), 10mm thick rendering in cement mortar (1:4) to walls, 50mm thick PCC (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in flooring, 40mm thick PCC (1:2:4) type B-1 on steps, painting to XPM fencing with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and shown in drawings. all connections and carrying out all routine tests before commissioning, complete all as specified and directed. | 1 | Each | - | - |
| 4 | Supply and fixing of Lightning arrestors (set of three) metal oxide surge type (ZnO) complete with all fittings transmission class discharge capacity 65 Kilo Amps suitable for 11000 volts complete all as specified and as directed. | 1 | Set of three | - | - |
| 5 | Supply , laying and testing XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor rating 11000 volts grade of size 95 Sqmm 3 core laid in trenches or passing through pipes/ducts or fixed to walls/poles complete all as specified. (Earth work, brick protection and sand cushioning shall be measured and paid for separately). | 70 | Rm | - | - |
| 6 | Supply , laying and testing XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 95 Sqmm 3.5 core laid in trenches or passing through pipes/ducts or fixed to walls/poles complete all as specified. (Earth work, brick protection and sand cushioning shall be measured and paid for separately). | 100 | Rm | - | - |
| 7 | Supply , laying and testing XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 06 Sqmm 2.0 core laid in trenches or passing through pipes/ducts or fixed to walls/poles complete all as specified. (Earth work, brick protection and sand cushioning shall be measured and paid for separately). | 40 | Rm | - | - |
stage.html
html • 0.05 MB
technical_844700.pdf
techsummary_844700.pdf
finance_844700.pdf
BOQ Comparative Chart
xlsx
finsummary_844700.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.32 MB
TD.pdf
Tender Documents • 1.22 MB
BOQ_844700.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .