REGIONAL OFFICE-JALPAIGURI SJDA COMPOSITE COMPLEX,DENGUAJHAR PIN-735121
ERECTION OF DIFFERENT SUB STATION EQUIPMENT,LAYING OF CONTROL CABLES AND OTHER ALLIED WORKS FOR THE NEW SWITCHYARD AND CONTROL ROOM OF HALDIBARI 33/11 KV SUB STATION UNDER IPDS OF JALPAIGURI DISTRICT
2019_WBSED_243213_1
RM/JRO/IPDS/E/19-20/07
Open Tender
Electrical Work/ Equipment
Fixed-rate
75 days
HALDIBARI
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,121
WBSEDCL
₹18,350
Yes
31 Aug 2020
9 Sept 2019
26 Sept 2019
9 Sept 2019
24 Sept 2019
9 Sept 2019
Amount
Fixing of 33 KV Polymer Composite Pin Insulator
Fixing of 33 KV Polymer Composite 70KN Disc Insulator with hardware fittings
Fixing of 33 KV Post Insulator (3 nos in a set)
Fixing of 11 KV Polymer Composite Pin Insulator
Erection, testing and commissioning of 33 KV, 400 A,3 Phase,double break CR type Isolator alongwith insulator,operating mechanism base channel,down pipe,auxiliary switch,terminal connector and other accessories complete as per TS.(i)with Earth Switch (HL)
(ii)without any attachment (LL)
(iii)without any attachment (HL).
Erection, testing and commissioning of 36 kV, 1250 A, 31.5 KA for 3 sec., 3-phase outdoor type SCADA Compatible Vacuum Circuit Breaker with support structure, marshalling box and other accessories complete as per TS & approved drawings.
Erection, testing and commissioning of 33 kV SCADA Compatible Breaker control and Relay panel (30 V DC, auxiliary supply) consisting of panel mounted digital voltmeter, Ammeter, PF meter, microprocessor based relays, provision for TVM energy meter, indicating lamps & other accessories complete as per TS & approved drawings.(i)Individual control of feeder
Individual control of transformer
Erection,testing,commisioning of RTCC Panel and other accessories complete
Erection, testing and commissioning of 33 kV, 200 - 200/ 1-1-1 A, 1-phase,Outdoor type, Current Transformer with terminal connectors, junction box etc. complete for Transformer Control as per TS & approved drawings.Erection, testing and commissioning of 33 kV, 200 - 200/ 1-1-1 A, 1-phase,Outdoor type, Current Transformer with terminal connectors, junction box etc. complete for Transformer Control as per TS & approved drawings.
Erection, testing and commissioning of 33 kV, 400 - 200/ 1-1 A, 1-phase,Outdoor type, Current Transformer with terminal connectors, junction box etc. complete for Feeder Control as per TS & approved drawings.Erection, testing and commissioning of 33 kV, 400 - 200/ 1-1 A, 1-phase,Outdoor type, Current Transformer with terminal connectors, junction box etc. complete for Feeder Control as per TS & approved drawings.
Erection, testing and commissioning of 33 kV/110V, 1-phase, 100 VA per phase potential transformer as per TS & approved drawings.
Supply & Installation of CT/PT Terminal Box
Erection, testing and commissioning of 33/0.433 kV, 100 kVA, OD type station service transformer with distribution box and all accessories as per TS & approved drawings.
Erection, testing and commissioning of 42 kV 1-phase, station class, heavy duty, gap less ZnO type Surge Arrestor with fittings and accessories complete as per TS & approved drawings.
Erection, testing and commissioning of 12 kV 1-phase, station class, heavy duty, gap less ZnO type Surge Arrestor on 11KV Cable support with fittings and accessories complete as per TS & approved drawings.
Erection, testing and commissioning of 12 kV, 16 KA for 3 sec. multi-panel metal enclosed, shunt trip, indoor type switchgear with motor operated spring charging Vacuum Circuit Breaker as per TS & approved drawings.2 incomer (1250 A) + 7 outgoing (800 A) + 1 bus coupler (1250 A) Bus Bar Rating 1250A
Installation/Erection, testing and commissioning of 15 nos x 2 V (30 V DC), 100 AH, Lead Acid Plante type Storage Battery along with terminal connectors, wooden rack , cables and other accessories complete as per TS.
Erection, testing and commissioning of 30 V DC, 20.5 A, Auto/ Manual Float-cum-Boost Charger for charging above Battery Bank complete with connectors, cables and other accessories ( as per TS ).
Stringing & sagging of 200 sqmm ACSR panther (3 Wire) for different connections.
Stringing & sagging of 100 sqmm ACSR DOG (3 Wire) for different connections.
Supply and Delivert of Aluminium tubular pipe bus 40 mm dia with all required accessories(Connectors, Copper Flat,Bimetalic Flat, MS Material) complete as per TS
Supply and delivery of clamp connectors,Copper Flat,Bimetalic Flat, MS Material for 40mm dia Aluminium Bus Pipe as per TS & approved drawings
Drawal of 40mm dia aluminium pipe on post insulators for 33KV HL &LL Bus & drooper between HL & LL with all necessary fittings and accessories complete as per TS & approved drawings.
Laying of 1.1KV grade PVC insulated steel armoured Copper Conductor Control Cable through surface trench includding digging of trench, supply & laying of sand , bricks(8 Bricks mer meter) etc complete for laying with supply and fixing of lugs,ferrules and termination sockets as per approved scheduled.(i) 2.5 sqmm,4 Core
(ii)2.5 sq mm, 8 core
(iii) 2.5 sq mm, 12 core
Dismantling of 36 kV, 1250 A, 31.5 KA for 3 sec., 3-phase outdoor type SCADA Compatible Vacuum Circuit Breaker with support structure, marshalling box and other accessories complete as per TS & approved drawings.
Dismantling of 33 kV SCADA Compatible Breaker control and Relay panel (30 V DC, auxiliary supply) consisting of panel mounted digital voltmeter, Ammeter, PF meter, microprocessor based relays, provision for TVM energy meter, indicating lamps & other accessories complete as per TS & approved drawings.(i) Individual control of transformer
(ii) Individual control of feeder
Dismantling of RTCC Panel and other accessories complete
Dismantling of 33 kV, 200 - 200/ 1-1-1 A, 1-phase,Outdoor type, Current Transformer with terminal connectors, junction box etc. complete for Transformer Control as per TS & approved drawings.Erection, testing and commissioning of 33 kV, 200 - 200/ 1-1-1 A, 1-phase,Outdoor type, Current Transformer with terminal connectors, junction box etc. complete for Transformer Control as per TS & approved drawings.
Dismantling of 33 kV, 400 - 200/ 1-1 A, 1-phase,Outdoor type, Current Transformer with terminal connectors, junction box etc. complete for Feeder Control as per TS & approved drawings.Erection, testing and commissioning of 33 kV, 400 - 200/ 1-1 A, 1-phase,Outdoor type, Current Transformer with terminal connectors, junction box etc. complete for Feeder Control as per TS & approved drawings.
Dismantling of 33 kV/110V, 1-phase, 100 VA per phase potential transformer as per TS & approved drawings.
Dismantling of 33/0.433 kV, 100 kVA, OD type station service transformer with distribution box and all accessories as per TS & approved drawings.
Dismantling of 15 nos x 2 V (30 V DC), 75 AH, Lead Acid Plante type Storage Battery along with terminal connectors, wooden rack , cables and other accessories complete as per TS.
Dismantling of 30 V DC, 16 A, Auto/ Manual Float-cum-Boost Charger for charging above Battery Bank complete with connectors, cables and other accessories ( as per TS ).
Dismantling of control cable(i)2.5 sq mm, 4 core
(ii) 2.5 sq mm, 8 core
(III) 2.5 sq mm, 12 core
Dismantling of 33 KV, 400 A,3 Phase,double break CR type Isolator alongwith insulator,operating mechanism base channel,down pipe,auxiliary switch,terminal connector and other accessories complete as per TS.(i)with Earth Switch (HL)
(ii)without any attachment (LL)
Dismantling of 12 kV, 16 KA for 3 sec. multi-panel metal enclosed, shunt trip, indoor type switchgear with motor operated spring charging Vacuum Circuit Breaker as per TS & approved drawings.2 incomer (1250 A) + 7 outgoing (800 A) + 1 bus coupler (1250 A) Bus Bar Rating 1250A
Deplinth of existing 6.3 MVA,33/11 KV PTR and erection the same on the newly erected plinth within 50 mtr
Hot filtration of Transformer oil
M/S R N ENTERPRISE
M/S TARUN ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .