| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.0 LAccepted-AOC OLD PULL MADIYA JAIRAMPUR AZAMGARH AZAMGARH UTTAR PRADESH 276001 | AZAMGARH | UTTAR PRADESH | 276001 | L1 | Accepted-AOC DUE TO LOWEST BID. | |
| 2 | L2₹13.9 L+₹55,410 (4.15%)Rejected-Finance | L2 | Rejected-Finance DUE TO HIGHER BID | |
| 3 | L3₹15.7 L+₹2.4 L (17.7%)Rejected-Finance SUMEL BAMANWAS SWAI MADHOPUR | L3 | Rejected-Finance DUE TO HIGHER BID | |
| 4 | L4₹16.7 L+₹3.4 L (25.5%)Rejected-Finance | L4 | Rejected-Finance DUE TO HIGHER BID | |
| 5 | L5₹17.8 L+₹4.5 L (33.5%)Rejected-Finance | L5 | Rejected-Finance DUE TO HIGHER BID |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
12 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (WEST) FEROZEPUR CANTT
GE (WEST) FEROZEPUR CANTT
REPAIR TO HOT WATER APPLIANCES AND ALLIED WORKS UNDER AGE E AND M OF GE (WEST) FEROZEPUR CANTT
2023_MES_618079_1
802023/GE-45/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
FEROZEPUR CANTT
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (WEST) FEROZEPUR CANTT
₹50,000
Yes
24 Nov 2023
15 Sept 2023
14 Oct 2023
15 Sept 2023
12 Oct 2023
29 Sept 2023
Amount
S&F in replacement steel tank suitable for 25 Litre geyser including taking down of geyser storage type cap 25 Litre, including taking down of geyser storage type cap 25 Litre. Including disconnecting electrical & water supply connection, dismantling, stripping up for inspection for repair, cleaning, replacement of unserviceable parts and re-assembling & re-fixing in position complete all as specified and directed.
All as per item No 1 here-in-before but of capacity 50 Litre.
S&F in replacement inner assembly steel with steel pressure screw for 25 Litre capacity complete all as per sample produce including taking down of geyser storage type cap 25 Litre, including disconnecting electrical & water supply connection, dismantling, stripping up for inspection for repair, cleaning, replacement of unserviceable parts and re-assembling & re-fixing in position complete all as specified and directed.
All as per item no 3 here-in-before but capacity 50 Litre.
S&F in replacement outer body made out of 18 guage MS sheet for geyser capacity 25 Litre size and shape as per sample produce, duly painted with white enamelled paint including taking down of geyser storage type cap 25 Litre including disconnecting electrical & water supply connection, dismantling, stripping up for inspection for repair, cleaning, replacement of unserviceable parts and re-assembling & re-fixing in position complete all as specified and directed. .
All as per item No 05 here-in-before but for capacity 50 Litre.
S&F in replacement heating element 1500 Watt capacity for geysers (in triangle/round shape) including taking down of geyser storage type cap 25/50 Litre, including disconnecting electrical & water supply connection, dismantling, stripping up for inspection for repair, cleaning, replacement of unserviceable parts and re-assembling & re-fixing in position complete all as specified and directed. Makes: Theeta/ Bajaj/ Racold/ Pioneer or techno-commercially equivalent as approved by GE
S&F in replacement heating element 2000 Watt capacity for geysers ( in triangle/round shape) including taking down of geyser storage type cap 25/50 Litre, including disconnecting electrical & water supply connection, dismantling, stripping up for inspection for repair, cleaning, replacement of unserviceable parts and re-assembling & refixing in position complete all as specified. Makes: Theeta/ Bajaj/ Racold/ Pioneeror techno-commercially equivalent as approved by GE
S&F in replacement thermostat range 20 degree to 80 degree centigrade ISI marked for 25/50 Litre capacity geysers including taking down of geyser storage type cap 25/50 Litre, including disconnecting electrical & water supply connection, dismantling, stripping up for inspection for repair, cleaning, replacement of unserviceable parts and re-assembling & re-fixing in position complete all as specified and directed.
S&F in replacement LED indicator lamp red & green as per existing shape and size, 230V complete all as specified and directed.
S&F in replacement PVC 3 core copper conductor flexible cable of size 2.5 Sqmm for geyser connection etc complete all as specified and directed.
S&F in replacement pressure release valve 15mm for 25 Litre cap geyser etc complete all as specified and directed.
S&F non-return valve of size 15mm for 25/50 Litre cap geyser etc. complete all as specified and directed.
S&F in replacement inlet pressure reducer valve of size 15mm suitable to fix in inlet of geyser of any size and shape complete all as specified and directed.
S&F in replacement bottom cover (Half round plate) duly powder coated and matching colour of existing geyser of any make for 25 Litre capacity including screws and connection of indicator etc including taking down of geyser storage type cap 25/50 Litre, including disconnecting electrical & water supply connection, dismantling, stripping up for inspection for repair, cleaning, replacement of unserviceable parts and re-assembling & re-fixing in position complete all as specified and directed.
All as per Item No 15 here-in-before but capacity 50 Litre.
S&F in replacement dead nut of suitable size (as per sample produce) for fixing on 25/50 Litre geysers of any make and size complete all as specified and directed.
S&F in replacement reinforced PVC connection pipe 15mm bore and 45cm long with brass nuts at both ends etc complete all as specified and directed.
S&F in replacement reinforced PVC connection pipe 15mm bore and 60cm long with brass nuts at both ends for hot water complete all as specified and directed.
S&F in replacement PVC Washer suitable for fixing in reinforced PVC Connection pipe of size 15mm all as specified and directed.
S&F in replacement heavy duty steel reinforced steel connection 15mm bore and 60cm long with steel nuts at both ends etc complete all as specified and directed.
S&F in replacement heavy duty steel reinforced steel connection 15mm bore & 45cm long with brass nut at both end etc complete all as specified & directed.
S&F in repair Stop valves for 15 mm Bore, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified & directed.
S&F in replacement of spacer ring for 25/50 Litre capacity made out of 1.6 mm thick MS sheet etc complete all as specified and directed.
S&F in replacement Chromium plated hexagonal nipple of 15mm dia of required length as per site requirement for connecting the PVC connection and replacement chromium plated stop cock to the geyser complete all as specified and directed.
S&F in replacement glass wool for geyser for inner side of Outer & Inner tank for insulation including taking down of geyser storage type cap 25/50 Litre, including disconnecting electrical & water supply connection, dismantling, stripping up for inspection for repair, cleaning, replacement of unserviceable parts and re-assembling & re-fixing in position complete all as specified and directed.
M&L for spray painting of geyser of any capacity 25 Litre with white duco paint, including taking down of geyser storage type cap 25 Litre and re-assembling & re-fixing in position complete all as specified and directed.
M&L for spray painting of geyser of any capacity 50 Litre with white duco paint complete all as specified and directed.
M&L for shifting/fixing of geyser of 25 Litre capacity in brick wall by taking down it from its existing location to new location by grouting of 04 Nos holding Fasteners nut bolts in PCC (1:2:4) of appropriate size, masonry work complete all as specified and directed.
M&L for shifting/fixing of geyser of 50 Litre capacity in brick wall by taking down it from its existing location to new location by grouting of 04 Nos holding Fasteners nut bolts in PCC (1:2:4) of appropriate size, masonry work complete all as specified and directed.
S&F in replacement metal clad 2 Pin plus earth arrangement (2P+E) top plug of 20 Amp capacity 230 volts only for replacement of burnt/ unserviceable metal clad top plug for geysers complete all as specified & directed.
S&F in replacement metal clad 2 Pin plus earth arrangement (2P+E) socket of 20 Amp capacity 230 volts only for replacement of burnt/ unserviceable metal clad socket for geysers complete all as specified & directed.
S&F in replacement 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 20 to 32 AMP, in the MCB DB complete with connection testing and commissioning complete all as specified & directed.
S&F in replacement Socket outlet, 2 in one 6 pin 5 and 15 Amps piano flush type ISI marked complete all as specified and directed.
S&F in replacement 3 pin Bakellite Top of 16 Amp capacity,240V only for replacement of burn / unserviceable top for geyser complete all as specified and directed.
S&F in replacement Switch piano flush type 16 amps, single pole one way duly ISI marked.
S&F in replacement Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole 20 Amp MCB complete with one single pole 20 Amp MCB complete all as specified and directed.
Taking down for gas welding of minor leakage geyser storage type Cap 25/50 Litre any make or type including disconnecting electrical and water supply connection, dismantling , stripping up for inspection and repair it by gas welding , cleaning, reassembling and re-fixing in position complete all as specified and directed. Note:- The replacement of unserviceable parts shall be measured and paid for separately under relevant item.
M&L for disconnecting, dismantling of solar water heating system including all water and electric connection of capacity 500 Litre per day and re-fixing the same in existing position after the following repairs and testing complete:- (a) Replacement of the worn out/missing nuts bolts , washers, unions, sockets flanges and screw etc complete. (b) Descaling/ desludging the hot water pipes and normal water by using appropriate chemicals/Anti corrosive/Anti scaling agent solution, cleaning and washing all copper tube & water circulated pipes of heat convertor sets thoroughly cleaning the complete solar pannel of making the tube scale free and reassembling the pannel. (c) Cleaning hot and cold water tanks, removing sludge and scale from the tank manually using suitable chemicals complete. (d) Repair of collector fins including required welding works etc complete. (e) Testing on completion after repair work and making the Solar Water Heater functional in each aspects. Note:- The spare parts such as Solar energy collector panel, toughned glass, rubber gasket, hose pipe, insulation for hot water pipe, heating element, thermostat, Water Storage tank, gate valve/float valve, MS Clamp shall be measured & paid separately under respective items.
All as per item No. 39 here-in-before but of capacity 300 Litre per day complete all as specified and directed.
Supply and installation in replacement of complete one solar energy collector panel (FPC) made of aluminium body with toughened glass complete with copper fins including all accessories capable to heat 100 Litre water per day suitable to be fitted for 500 LPD, 300 LPD & 100 LPD Solar water heating system complete all as specified and directed. Makes:-Tata BP Solar/Sun Stellar/Inter Solar/RES or Equivalent. Notes: 1 Solar FPC collector can heat 100 LPD water.
S&F hose pipe 1" (25 mm) inner dia for hot/cold water for solar system of suitable length as existing size complete with 02 Nos clamps of required size complete all as specified and directed.
M&L for legging to pipes used for Hot water supply or plumbing all around with 25mm min thick bonded material wool preformed, snap on pipe section of density of 144 Kg/Cum conforming to IS 9842 for 15 mm dia pipe complete all as specified and directed.
S&F Evacuated Tubes Box of 58mm×1800mm or equivalent size as of existing complete all as specified and directed.
S&F Evacuated Tubes Box of 58mm×2100mm or equivalent size as of existing complete all as specified and directed.
M&L in replacement Sub main wiring with 4 Sqmm (Nominal area) with two runs (Red for phase and Black for neutral) of single core, PVC insulated, multi stranded, unsheathed, FRLS copper conductor cables 1100 V grade drawn through existing PVC conduits/casing-caping fixed to wall/ceiling etc including 4 sqmm (nominal area) single core, PVC insulated, multistranded, unsheathed, copper conductor green in colour as earth wire and duly connected to earth point complete as specified and directed. Note: 2 run of wire and 1 run of earth wire will be measured as one unit.
S&F heating element for solar water heater of wattage 3.0 KW operating on 240 Volt, AC as in repairs complete all as specified and directed.
S&F heating element for solar water heater of wattage 2.0 KW operating on 240 Volt, AC as in repairs complete all as specified and directed.
S&F thermostat for solar water heater of thermostat range 20 degree to 80 degree centigrade ISI marked on 240 Volt, AC as in repairs complete all as specified and directed.
S&F rotational moulded triple layered polyethylene water storage tank of capacity 500 Litre HDPE/LDPE tank cylindrical vertical with closed top hoisted and fixed in position including taking down water tanks all as specified and directed.
S&F ball brass valves high pressure with polythene float and fitnut complete screwed for iron pipe or brass ferrule and fixed of size 20 mm dia as fixed in repairs complete all as specified and as directed.
S&F gun metal globe or gate valves with iron wheel head, screwed both ends for iron pipe of size 20 mm dia as fixed in repairs complete all as specified and as directed.
S&F MCB, Single pole 240 Volt, 40 Amps 10 KA 'B Series in repair complete all as specified and as directed.
S&F MCB SPN, 40Amps - 63Amps, 240 Volts, "C" series, 10KA duly ISI marked, in MCB DB, complete with connection testing and commissioning in repair complete all as specified and directed.
S&F sheet metal enclosure SPN DB's 2 way Single door factory made powder coated out of CRCA mild steel sheet 1.2 mm thick wih metallic painting white series, 240 Volt, 2 way dust and vermin proof suitable for incorporation of MCBs duly concealed in wall and making good to disturbed surface and colour matching in repair complete all as specified and directed.
S&F 20 mm bore medium grade steel tubes galvanised with all fittings and fixed complete to walls & celling or laid in floor as fixed in repairs complete all as specified and directed.
S&F 15 mm bore medium grade steel tubes galvanised with all fittings and fixed complete to walls & celling or laid in floor as fixed in repairs complete all as specified and directed.
M/s Shri Krishna Enterprises
GS and Co
M/s Sham and Company
M/S CHAWLA CONSTRUCTION COMPANY
manoj and company
M/s Bansi Lal
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .