Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹29.4 LAccepted-AOC | ₹29.4 L Quoted ₹30.5 L | 1 | Accepted-AOC Being lowest and reasonable |
| 2 | 2₹30.9 L+₹45,718 (1.50%)Rejected-Finance | ₹30.9 L+₹45,718 (1.50%) | 2 | Rejected-Finance Not being the lowest bidder |
| 3 | 3₹37.7 L+₹7.3 L (23.8%)Rejected-Finance | ₹37.7 L+₹7.3 L (23.8%) | 3 | Rejected-Finance Not being the lowest bidder |
| 4 | 4₹38.8 L+₹8.3 L (27.3%)Rejected-Finance | ₹38.8 L+₹8.3 L (27.3%) | 4 | Rejected-Finance Not being the lowest bidder |
| 5 | 5₹39.0 L+₹8.5 L (27.9%)Rejected-Finance | ₹39.0 L+₹8.5 L (27.9%) | 5 | Rejected-Finance Not being the lowest bidder |
Tender Value
₹41 L
EMD Value
₹82,000
Closing Date
6 Jul 2020, 6:00 pmClosed
GE I R AND D RCI, HYDERABAD
GE(I) RND RCI, MILITARY ENGINEER SERVICES, VIGNYANAKANCHA, RCI, HYDERABAD
REPAIR/REPLACEMENT OF LT DISTRIBUTION SYSTEM/UG CABLE AND CONNECTED ITEMS AT RESIDENTIAL AREA CPDC ELSEC AND DSC LINES UNDER GE I RND RCI HYDERABAD
2020_MES_350910_1
8563
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE I R AND D RCI
MES enlisted Class D category b i Un enlisted Meeting enlistment criteria of D class in MES and having no recovery pending. For further details ref NIT
8 documents required · 8 mandatory
₹500
Yes
GE I R AND D RCI, HYDERABAD
₹82,000
Yes
12 Oct 2020
8 Jun 2020
13 Jul 2020
8 Jun 2020
6 Jul 2020
22 Jun 2020
Amount
Supplying, laying, jointing, testing and commissioning 1100 volts grade, LT XLPE insulated, PVC sheathed as per IS-7098 (Part-I), 1988 galvanized steel strip or wire armoured, heavy duty, electric cables, with multistranded aluminium conductor laid in trenches/ passing through pipe/duct/road crossing or fixed on poles, walls with suitable size clamps made out of mild steel flat iron including jointing material such as crimping type lugs, brass cable glands, heavy duty double compression type etc., including taking down unserviceable cable complete all as specified and directed for the following sizes:- Note: Earthwork Excavation, sand cushioning GI pipe and cable protection will be measured and paid separately.
3.5core 240Sqmm
3.5core 185Sqmm
3.5core 120Sqmm
3.5core 95Sqmm
3.5core 70Sqmm
3.5core 50Sqmm
3.5core 35Sqmm
3.5core 25Sqmm
3.5/4core 16Sqmm
Taking up, unserviceable LT XLPE underground cable of size 3.5/4 core 16Sqmm to 95Sqmm, 1100 volts grade from trenches or walls and re-laying of cable in trenches/ passing through pipe/duct/road crossing or fixed on poles, walls in different location complete all as directed by Engineer in Charge.
Taking up, unserviceable LT XLPE underground cable of size 3.5 core 120Sqmm to 240Sqmm, 1100 volts grade from trenches or walls and re-laying of cable in trenches/ passing through pipe/duct/road crossing or fixed on poles, walls in different location complete all as directed by Engineer in Charge. Note for item No 2 & 3: Earthwork Excavation, sand cushioning GI pipe and cable protection will be measured and paid separately.
Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50m depth for foundation, for laying of pipes/cables/poles etc., and getting out in any type of soil complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each layer as in soil complete all as specified and as directed.
Removing excavated material/soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
Supply and spreading sand of approved quality for cushioning of cable laid in trenches including compacting and leveling complete all as specified and as directed Note: Punned thickness will only be measured and paid.
Supply and laying un reinforced precast concrete cable cover, class LV Type 2, size 300mm x 180mm x 40mm, laid flat adjacent to each other, perpendicular to cable in trenches for protection of cable complete all as directed.
Cutting of existing bituminous/PCC road or flooring/ plinth protection for laying of GI pipe in intersection for passing of LT XLPE cable including excavation in any type of soil, returning and filling in and making good top 30cm of the trench by providing PCC 1:2:4 type B1 using 20mm graded stone aggregate to flush with existing road surface complete all as directed.
S&F, 50mm dia GI pipe light grade fixed to walls/poles or laid in trenches, road crossing etc., for protection of underground cable/earth strip including sealing ends with hessian cloth impregnated with bituminous compound in ground and with teak wood bushes for ends fixed on walls/poles complete all as specified and directed.
S&F, 80mm dia GI pipe light grade fixed to walls/poles or laid in trenches, road crossing etc., for protection of underground cable/earth strip including sealing ends with hessian cloth impregnated with bituminous compound in ground and with teak wood bushes for ends fixed on walls/poles complete all as specified and directed.
S&F in repairs, 4pole 630Amp MCCB with adjustable thermal and magnetic settings, 50KA rupturing capacity at 415volt, conform to IEC -60947-II/ IS-13947-II including provision of copper cable/extended terminals of suitable ratings from MCCBs to busbar and connection of LT cables with MCCBs with suitable size aluminium lugs complete all as specified and directed. Make: Legrand CAT No 4220 23 or equivalent in L&T/ Siemens/Schneider/C&S
All as per item No 12 above but 4Pole 400Amp MCCB, 50KA Make: Legrand CAT No 4220 21 or equivalent in L&T/ Siemens/Schneider/C&S
All as per item No 12 above but 4Pole 200Amp MCCB, 36KA Make: Legrand CAT No 4202 48 or equivalent in L&T/ Siemens/Schneider/C&S
All as per item No 12 above but 4Pole 100Amp MCCB, 16KA Make: Legrand CAT No 4200 15 or equivalent in L&T/Siemens/Schneider/C&S
All as per item No 12 above but 3Pole 100Amp MCCB, 16KA Make: Legrand CAT No 4200 05 or equivalent in L&T/Siemens/Schneider/C&S
All as per Sl item No. 12 above but 3 pole 63Amps MCCB, 16KA 415volts Make: Legrand CAT No 4200 03 or equivalent in L&T/ Siemens/Schneider/C&S
S&F in repairs, aluminium lugs suitable for 25Sqmm cable complete all as specified and directed.
S&F in repairs, aluminium lugs suitable for 35Sqmm cable complete all as specified and directed.
S&F in repairs, aluminium lugs suitable for 50Sqmm cable complete all as specified and directed.
S&F in repairs, aluminium lugs suitable for 70Sqmm cable complete all as specified and directed.
S&F in repairs, aluminium lugs suitable for 95Sqmm cable complete all as specified and directed.
S&F in repairs, aluminium lugs suitable for 120Sqmm cable complete all as specified and directed.
S&F in repairs, aluminium lugs suitable for 150Sqmm cable complete all as specified and directed.
S&F in repairs, aluminium lugs suitable for 185Sqmm cable complete all as specified and directed.
S&F in repairs, aluminium lugs suitable for 240Sqmm cable complete all as specified and directed.
S&F in repairs, aluminium lugs suitable for 400Sqmm cable complete all as specified and directed.
Disconnecting electric supply and removing burnout/ unserviceable cable jointing kit, supply and jointing new straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5core XLPE armoured aluminium conductor cable of size 185 to 300sqmm for 1.1KV (Earthed) grade including testing complete all as specified and directed.
All as per item No 28 above but cable of size 3.5core 150sqmm to 185sqmm.
All as per item No 28 above but cable of size 3.5core 70sqmm to 150sqmm.
All as per item No 28 above but cable of size 3.5/4core 25sqmm to 50sqmm Note for item No 28 to 31: Quoted rate shall deemed to include cost of earth work excavation in any type of soil and returning and filling in.
M&L, two coats of spray painting using synthetic enamel paint to outer surfaces LT panel board of any type, indoor/outdoor, area of panel board not exceeding 3Sqm complete all as directed.
M&L, two coats of spray painting using synthetic enamel paint to outer surfaces LT panel board of any type, indoor/outdoor, area of panel board exceeding 3Sqm and not exceeding 6Sqm complete all as directed.
Supply, Install, testing and commissioning, factory made and tested, CPRI approved LT panel board outdoor type, weather, dust and vermin proof, free standing floor mounting type mounted on floor, separate cable alley for all the feeders, suitable for 440Volts, 3 Phase 4wire 50Hz AC supply system, conforming to IS, IP-54 class protection and made of 3mm CRCA mild steel sheet & angle iron frame, compartmentalized with rubber gasket hinged doors, front & rear opening and locking arrangement (including provision of 65mm Godrej (freedom) lock with 2 keys) with necessary bus bar arrangement with electrolytic grade aluminium bus bar 1000Amps rating for phase and neutral 4 strips with colour
coded PVC sleeves, installed on epoxy insulators housed in separate bus chambers covered with heat shrinkable sleeves with necessary bus bar tapings for MCCBs, copper control wiring of required size for instruments and duly powder coated on the outside and inside including air ventilation for heat dissipation, suitable size knock out holes for cable glands, necessary earthwork excavation and provision of PCC platform 100mm thick with PCC 1:2:4 type B-2 using 40mm graded stone aggregate one meter around the panel board, cable gland and lugs for incoming and outgoing cable etc., independent multilayer chambers to accommodate complete all as specified and directed including the following accessories :-
MCCB 4pole, 630Amps, with adjustable thermal and magnetic settings, 50KA rupturing capacity at 415volt, conform to IEC -60947-II/ IS-13947-II - 01 No (Incoming)
MCCB 4pole, 400Amps, with adjustable thermal and magnetic settings, 36KA rupturing capacity at 415volt, conform to IEC -60947-II/ IS-13947-II - 01 No (Outgoing)
MCCB 4pole, 250Amps, with adjustable thermal and magnetic settings, 36KA rupturing capacity at 415volt, conform to IEC -60947-II/ IS-13947-II - 01 No (Outgoing)
MCCB 4pole, 125Amps, with adjustable thermal and magnetic settings, 16KA rupturing capacity at 415volt, conform to IEC -60947-II/ IS-13947-II - 04 No (Outgoing)
Indicator lamp R,Y,B LED type with 3 Nos of 2A HRC fuses - 01 Set
Supply, Install, testing and commissioning, factory made and tested, CPRI approved LT panel board outdoor type, weather, dust and vermin proof, free standing floor mounting type mounted on floor, separate cable alley for all the feeders, suitable for 440Volts, 3 Phase 4wire 50Hz AC supply system, conforming to IS, IP-54 class protection and made of 3mm CRCA mild steel sheet & angle iron frame, compartmentalized with rubber gasket hinged doors, front & rear opening and locking arrangement (including provision of 65mm Godrej (freedom) lock with 2 keys) with necessary bus bar arrangement with electrolytic grade aluminium bus bar 1000Amps rating for phase and neutral 4 strips with colour
coded PVC sleeves, installed on epoxy insulators housed in separate bus chambers covered with heat shrinkable sleeves with necessary bus bar tapings for MCCBs, copper control wiring of required size for instruments and duly powder coated on the outside and inside including air ventilation for heat dissipation, suitable size knock out holes for cable glands, necessary earthwork excavation and provision of PCC platform 100mm thick with PCC 1:2:4 type B-2 using 40mm graded stone aggregate one meter around the panel board, cable gland and lugs for incoming and outgoing cable etc., independent multilayer chambers to accommodate complete all as specified and directed including the following accessories :-
MCCB 4pole, 630Amps, with adjustable thermal and magnetic settings, 50KA rupturing capacity at 415volt, conform to IEC -60947-II/ IS-13947-II - 01 No (Incoming)
MCCB 4pole, 125Amps, with adjustable thermal and magnetic settings, 16KA rupturing capacity at 415volt, conform to IEC -60947-II/ IS-13947-II - 07 No (Outgoing)
Indicator lamp R,Y,B LED type with 3 Nos of 2A HRC fuses - 01 Set
Supply, Install, testing and commissioning, factory made and tested, CPRI approved LT panel board outdoor type, weather, dust and vermin proof, free standing floor mounting type mounted on floor, separate cable alley for all the feeders, suitable for 440Volts, 3 Phase 4wire 50Hz AC supply system, conforming to IS, IP-54 class protection and made of 3mm CRCA mild steel sheet & angle iron frame, compartmentalized with rubber gasket hinged doors, front & rear opening and locking arrangement (including provision of 65mm Godrej (freedom) lock with 2 keys) with necessary bus bar arrangement with electrolytic grade aluminium bus bar 1000Amps rating for phase and neutral 4 strips with colour
coded PVC sleeves, installed on epoxy insulators housed in separate bus chambers covered with heat shrinkable sleeves with necessary bus bar tapings for MCCBs, copper control wiring of required size for instruments and duly powder coated on the outside and inside including air ventilation for heat dissipation, suitable size knock out holes for cable glands, necessary earthwork excavation and provision of PCC platform 100mm thick with PCC 1:2:4 type B-2 using 40mm graded stone aggregate one meter around the panel board, cable gland and lugs for incoming and outgoing cable etc., independent multilayer chambers to accommodate complete all as specified and directed including the following accessories :-
MCCB 4pole, 630Amps, with adjustable thermal and magnetic settings, 50KA rupturing capacity at 415volt, conform to IEC -60947-II/ IS-13947-II - 01 No (Incoming)
MCCB 4pole, 125Amps, with adjustable thermal and magnetic settings, 16KA rupturing capacity at 415volt, conform to IEC -60947-II/ IS-13947-II - 11 No (Outgoing)
Indicator lamp R,Y,B LED type with 3 Nos of 2A HRC fuses - 01 Set
Supply, Install, testing and commissioning, factory made and tested, CPRI approved LT panel board outdoor type, weather, dust and vermin proof, free standing floor mounting type mounted on floor, separate cable alley for all the feeders, suitable for 440Volts, 3 Phase 4wire 50Hz AC supply system, conforming to IS, IP-54 class protection and made of 3mm CRCA mild steel sheet & angle iron frame, compartmentalized with rubber gasket hinged doors, front & rear opening and locking arrangement (including provision of 65mm Godrej (freedom) lock with 2 keys) with necessary bus bar arrangement with electrolytic grade aluminium bus bar 800Amps rating for phase and neutral 4 strips with colour
coded PVC sleeves, installed on epoxy insulators housed in separate bus chambers covered with heat shrinkable sleeves with necessary bus bar tapings for MCCBs, copper control wiring of required size for instruments and duly powder coated on the outside and inside including air ventilation for heat dissipation, suitable size knock out holes for cable glands, necessary earthwork excavation and provision of PCC platform 100mm thick with PCC 1:2:4 type B-2 using 40mm graded stone aggregate one meter around the panel board, cable gland and lugs for incoming and outgoing cable etc., independent multilayer chambers to accommodate complete all as specified and directed including the following accessories :-
MCCB 4pole, 400Amps, with adjustable thermal and magnetic settings, 36KA rupturing capacity at 415volt, conform to IEC -60947-II/ IS-13947-II - 01 No (Outgoing)
MCCB 4pole, 125Amps, with adjustable thermal and magnetic settings, 16KA rupturing capacity at 415volt, conform to IEC -60947-II/ IS-13947-II - 04 No (Outgoing)
Indicator lamp R,Y,B LED type with 3 Nos of 2A HRC fuses - 01 Set
Supply, Install, testing and commissioning, factory made and tested, CPRI approved LT panel board outdoor type, weather, dust and vermin proof, free standing floor mounting type mounted on floor, separate cable alley for all the feeders, suitable for 440Volts, 3 Phase 4wire 50Hz AC supply system, conforming to IS, IP-54 class protection and made of 3mm CRCA mild steel sheet & angle iron frame, compartmentalized with rubber gasket hinged doors, front & rear opening and locking arrangement (including provision of 65mm Godrej (freedom) lock with 2 keys) with necessary bus bar arrangement with electrolytic grade aluminium bus bar 400Amps rating for phase and neutral 4 strips with colour
coded PVC sleeves, installed on epoxy insulators housed in separate bus chambers covered with heat shrinkable sleeves with necessary bus bar tapings for MCCBs, copper control wiring of required size for instruments and duly powder coated on the outside and inside including air ventilation for heat dissipation, suitable size knock out holes for cable glands, necessary earthwork excavation and provision of PCC platform 100mm thick with PCC 1:2:4 type B-2 using 40mm graded stone aggregate one meter around the panel board, cable gland and lugs for incoming and outgoing cable etc., independent multilayer chambers to accommodate complete all as specified and directed including the following accessories :-
MCCB 4pole, 200Amps, with adjustable thermal and magnetic settings, 36KA rupturing capacity at 415volt, conform to IEC -60947-II/ IS-13947-II - 01 No (Outgoing)
MCCB 4pole, 125Amps, with adjustable thermal and magnetic settings, 16KA rupturing capacity at 415volt, conform to IEC -60947-II/ IS-13947-II - 03 No (Outgoing)
Timer 10KV - 01 No
Power Contactor ML-6 - 01No
Indicator lamp R,Y,B LED type with 3 Nos of 2A HRC fuses - 01 Set
SHRI GANESH ENTERPRISES
EXELLENT POWER CORPORATION
M/s ANUSHA ENTERPRISES
Shreshta Associates
Mavee Syndicate
Maruthi international
SUN LIGHT HOUSE
M/S GDR CONSTRUCTIONS
Anjana corporation
UNITY ENGINEERING TRADERS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .