Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.1 LAccepted-AOC 712 GORAKHPUR JABALPUR 482001 MP | JABALPUR | MADHYA PRADESH | 482001 | L1 | Accepted-AOC L1 bidder lowest | |
| 2 | L2₹30.7 L+₹12,489 (0.41%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹34.3 L+₹3.7 L (12.3%)Rejected-Finance MAIN ROAD RANJHI BAZHAR JABALPUR MP PIN 482005 | JABALPUR | MADHYA PRADESH | 482005 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹34.3 L+₹3.8 L (12.3%)Rejected-Finance 114 BARH CHONDI BARH PATNA BIHAR 803213 | PATNA | PATNA | BIHAR | 803213 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹34.4 L+₹3.9 L (12.7%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
19 Nov 2020, 6:00 pmClosed
GE (West) Jabalpur
Garrison Engineer (West) Jabalpur Supply Marg Post Box No. 54 Jabalpur Cantt-482001 (MP)
REPAIR/REPLACEMENT OF INTERNAL WIRING, FITTING FIXTURE DISTRIBUTION MAINS, SUB MAIN WIRING AND OTHER CONNECTED SERVICE CONNECTION UNDER GE (WEST) JABALPUR
2020_MES_389102_1
8289/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (West) Jabalpur
As per Tender documents
5 documents required · 5 mandatory
₹500
GE (West) Jabalpur
₹96,000
11 Dec 2020
22 Oct 2020
21 Nov 2020
22 Oct 2020
19 Nov 2020
5 Nov 2020
23 Oct 2020 - 3 Nov 2020
Amount
Supply & Fixing in repairs sheet metal enclosure MCB DB double door , Vertical Triple pole and neutral [VTPN], 440 volts, 4 way with 200 Amp, 10 KA breaking capacity rated copper bus bar, Din rail earth bar with blanking plate wherever required and IP-43 degree protection complete all as specified & directed. Make : Legrand CAT NO 507745 / siemens/ GE /schneider
Supply & Fixing in repairs sheet metal enclosure MCB DB double door, Triple pole and neutral, 440 volts, 4 way with 200 Amp, 10 KA breaking capacity rated copper bus bar with blanking plate wherever required and IP-43 degree protection complete all as specified & directed. Make : Legrand CAT NO 507640 / SIEMENS CAT NO 8GB32203RC04 / GE/schneider
Supply & Fixing in repair sheet metal enclosure MCB DB double door, single pole and neutral, 240 volts, 4 way with 200 Amp, 10 KA breaking capacity rated bus bar with blanking plate wherever required and IP-43 degree protection complete all as specified & directed.Make : Legrand CAT NO 507610 /SIEMENS /ABB / schneider
Supply & Fixing in repair sheet metal enclosure MCB DB double door single pole and neutral, 240 volts, 8 way with 200 Amp, 10 KA breaking capacity rated bus bar with blanking plate wherever required and IP-43 degree protection complete all as specified & directed. Make : Legrand CAT NO 507611 / SIEMENS CAT NO 8 GB 32102RC8/GE/schneider
Supply & Fixing in repair sheet metal enclosure MCB DB double door single pole and neutral, 240 volts, 12 way with 200 Amp, 10 KA breaking capacity rated bus bar with blanking plate wherever required and IP-43 degree protection complete all as specified & directed. Make : Legrand CAT NO507612 / SIEMENS CAT NO 8GB32203RC12/GE/schneider
Supply & Fixing in repairs MCB Triple Pole and Neutral 63 Amps,10KA breaking capacity complete all as specified & directed. Make : Legrand DX3 TPN C 63A AC 408683 / Siemens cat no- 5SL44637 RC / GE /schneider
Supply & Fixing in repairs MCB double pole and neutral 230Volt, 32 Amps,10KA breaking capacity complete all as specified & directed. Make : Legrand DX3 DP CAT No 408636/ Siemens cat no- 5SL 42327RC / GE/schneider
Supply & Fixing in repairs MCB Double Pole and Neutral 240Volt, 63 Amps,10KA breaking capacity complete all as specified & directed. Make : Legrand Dx3 408639 / Siemens / GE/schneider
Supply & Fixing in repairs MCB Single Pole 240Volt, 6 to 32Amps,10KA breaking capacity complete all as specified & directed. Make : Legrand cat no DX3 SP 408587,408590,408592,408593,408594,408595 / Siemens cat no- 5SL41067RC, 5SL41107RC, 5SL41167RC, 5SL41207RC, 5SL41257RC, 5SL41327RC / GE/schneider
Supply & Fixing in repairs RCBO double Pole 240Volt, 32 Amp,100 MA protection for earth over load and short circuit complete all as specified & directed. Make : Legrand 411333 / Siemens / GE
Supply & Fixing in repairs RCBO four Pole 240Volt, 63 Amp,100 MA protection for earth over load and short circuit complete all as specified & directed. Make : Legrand 411374 / Siemens / GE
Taking down carefully any type of old unserviceable point wiring copper or aluminium conductor (light, fan, socket, bell or power) point complete with fittings such as switches ceiling roses, lamp holders, sockets, fan regulators, call bell, light fittings with PVC conduit surface / concealed or wooden battens including sunken cast iron / pressed steel terminal boxes etc and making good the disturbed surfaces of walls, roof, floors etc to match with the existing surfaces complete all as specified & directed by Engineer-in-Charge.
Taking down carefully and re-fixing ceiling fan / Exhaust fan of any sweep with 1.5 Sqmm new copper wire upto ceiling rose complete all as specified and directed.
S&F in repairs Sub main wiring with two single core PVC Insulated cable two run of size 6.0 Sqmm multi-strand copper conductor FRLS cable 1100 volts grade drawing in and including PVC conduit, medium grade not less than 25 mm dia with all conduit accessories and one run of 4.0 Sqmm multi-strand copper conductor FRLS cable as continuous earth wire complete all as specified and directed. Note : - Two run of 6.0 Sqmm & one run of 4.0 Sqmm cable shall be measured as one unit run Make:FInolex,havells or equivalent
S&F in repairs Sub main wiring with two single core PVC Insulated cable two run of size 4.0 Sqmm multi-strand copper conductor FRLS cable 1100 volts grade drawing in and including PVC conduit, medium grade not less than 25 mm dia with all conduit accessories and one run of 2.5 Sqmm multi-strand copper conductor FRLS cable as continuous earth wire complete all as specified and directed. Note : - Two run of 4.0 Sqmm & one run of 2.50 Sqmm cable shall be measured as one unit run.make:FInolex,havells or equivalent
S&F in repairs Sub main wiring with four single core PVC Insulated cable two run of size 10.0 Sqmm multi-strand copper conductor FRLS cable 1100 volts grade drawing in and including PVC conduit, medium grade not less than 25 mm dia with all conduit accessories and one run of 6.0 Sqmm multi-strand copper conductor FRLS cable as continuous earth wire including making good disturbed surface to match existing complete all as specified & directed. Note : - Two run of 10.0 Sqmm & one run of 6.0 Sqmm cable shall be measured as one unit run.Make:FInolex,havells or equivalent
S&F in repairs Sub main wiring with four single core PVC Insulated cable four run of size 10.0 Sqmm multi-strand copper conductor FRLS cable 1100 volts grade drawing in and including PVC conduit, medium grade not less than 32 mm dia with all conduit accessories and two run of 6.0 Sqmm multi-strand copper conductor FRLS cable as continuous earth wire including making good disturbed surface to match existing complete all as specified & directed. Note : - Four run of 10.0 Sqmm & two run of 6.0 Sqmm cable shall be measured as one unit run.Make:FInolex,havells or equivalent
S&F in repairs Sub main wiring with two single core PVC Insulated cable two run of size 2.5 Sqmm multi-strand copper conductor FRLS cable 1100 volts grade drawing in and including PVC conduit, medium grade not less than 25 mm dia with all conduit accessories and one run of 1.5 Sqmm multi-strand copper conductor FRLS cable as continuous earth wire including making good disturbed surface to match existing complete all as specified & directed. Note : - Two RUN of 2.5 Sqmm & one run of 1.5 Sqmm cable shall be measured as one unit run. Make:FInolex,havells or equivalent
Supply & fixing in repair 25 mm dia non mettalic Rigid PVC conduit, ISI Marked conforming to IS : 9537 medium grade Including all fittings like bends, elbow reducer, junction boxes, tee bell mouth fixing accessories such as coupler lock, nuts, saddles pipe hooks etc complete including cutting & chasing required on brick wall not exceeding 10 CM girth for concealed conduit wiring and making good to disturbed surface with cement mortar 1:3 and treated with distemper or colour wash to match with existing surfaces complete all as specified & directed.
Supply & fixing in repair 32 mm dia non mettalic Rigid PVC conduit, ISI Marked conforming to IS : 9537 medium grade Including all fittings like bends, elbow reducer, junction boxes, tee bell mouth fixing accessories such as coupler lock, nuts, saddles pipe hooks etc complete including cutting & chasing required on brick wall not exceeding 10 CM girth for concealed conduit wiring and making good to disturbed surface with cement mortar 1:3 and treated with distemper or colour wash to match with existing surfaces complete all as specified & directed.
Material & Labour for concealed Point wiring with PVC Insulated 1.5 Sqmm multi-strand copper conductor FRLS cable 1100 Volts grade drawn into and including concealed PVC conduit medium grade not less than 20mm (ISI marked) including all fitting and fixing accessories including 1.25 mm thick sunken pressed steel terminal boxes duly painted with two coats of anti-corrosive paint outside and two coats of aluminium paint inside with and including 3mm thick hylam brand laminated white bakelite sheet cover for mounting switches, sockets, fan regulators fixed with CP screws with cup washers and PVC insulated 1.5 Sqmm multi-strand copper conductor cable as earth wire and making good the disturbed surfaces with cement sand mortar 1:3 to match with the existing surfaces complete all as specified & directed by Engineer-in-charge.
(a) One light point controlled by one switch.
(b) One fan point controlled by one switch.
(c) One socket point 5 Amp controlled by one switch on same board.
(d) One socket point 5 Amp controlled by one switch on Independent board.
(e) One socket point 5 Amp controlled by one switch on Independent board below the switch board.
(f) One bell point controlled by one bell push button independent board.
(g) One light point controlled by two way switch.
Ditto all as per above item but with 1100 Volts grade copper stranded conductor FRLS cable of size 2.5 Sqmm main & with 1.5 Sqmm earth multi-strand copper conductor cable as earth wire for 3 pin switch socket outlet 15 Amp on Independent board complete all as specified & directed by Engineer-in-Charge.
Ditto all as per above item but with 1100 Volts grade copper stranded conductor FRLS cable of size 4.0 Sqmm main & with 2.5 Sqmm earth multi-strand copper conductor cable as earth wire for 3 pin switch socket outlet 15 Amp on Independent board complete all as specified & directed by Engineer-in-Charge.
Material & Labour for point wiring with PVC Insulated 1.5 Sqmm multi-strand copper conductor FRLS cable 1100 Volts grade drawn into the existing conduits including all fitting and fixing accessories including 1.25 mm thick sunken pressed steel terminal boxes duly painted with two coats of anti-corrosive paint outside and two coats of aluminium paint inside with and including 3mm thick hylam brand laminated white bakelite sheet cover or inner outer plate for modular switches/socket for mounting switches, sockets, fan regulators fixed with CP screws with cup wahssrs and PVC insulated 1.5 Sqmm multi-strand copper conductor cable as earth wire and making good the disturbed surfaces with cement sand mortar 1:3 to match with the existing surfaces complete all as specified & directed by Engineer-in-charge.
(a) One light point controlled by one switch.
(b) One fan point controlled by one switch.
(c) One socket point 5 Amp controlled by one switch on same board.
(d) One socket point 5 Amp controlled by one switch on Independent board.
(e) One socket point 5 Amp controlled by one switch on Independent board below the switch board.
(f) One bell point controlled by one bell push button independent board.
(g) One light point controlled by two way switch.
Ditto all as per above item but with 1100 Volts grade copper stranded conductor FRLS cable of size 2.5 Sqmm main & with 1.5 Sqmm earth multi-strand copper conductor cable as earth wire for 3 pin switch socket outlet 15 Amp on Independent board complete all as specified & directed by Engineer-in-Charge.
Ditto all as per above item but with 1100 Volts grade copper stranded conductor FRLS cable of size 4.0 Sqmm main & with 2.5 Sqmm earth multi-strand copper conductor cable as earth wire for 3 pin switch socket outlet 15 Amp on Independent board complete all as specified & directed by Engineer-in-Charge.
M&L for drawing the wire in with casing caping complete with point wiring with FRLS PVC insulated, unsheathed stranded copper conductor of nominal area 1.5 Sqmm, 1100 volts grade, along with one single run of same size and type of copper wire as continuous earth wire to common earth dolly in and sunken terminal boxes pressed MS/GI steel terminal boxes not less than 1.20 mm thick for mounting switch, socket etc including 3 mm thick Hylam brand sunmica laminated sheet cover or inner outer plates for modular switches with brass screw and cup washers with all accessories and making good to disturbed surface with cement mortar ratio of 1:3 and matching surface with existing white/colour wash, oil bound or cement base paint etc to match with existing surface complete all as specified and directed and suitable for the following: -Make of wire -Finolex/plaza/gloster
(i) One light point point controlled by one way, single pole switch
(ii) One light one fan point controlled by one way, single pole switch
(iii) One 3 pin socket outlet, 6 Amp on “independent board” but below/side the switch board of the light point in same vertical plane.
(iv) One 3 pin socket out let, 6 amps on the "same board" with other switches
(v) One 3 pin socket outlet, 6 Amp on “independent board”
(vi) One bell / buzzer point controlled by one bell push
(vii) do but one light point controlled by two way switch
Ditto all as per above items but drawing in casing caping point wiring using 2.5 Sqmm (Nominal area)triple layer FRLS PVC insulated unsheathed copper conductor 1100 volts for one 3/6 pin socket outlet ,suitable for 6/16 amps on “independent board”.with 1.5 sqmm with one single run copper wire as continuous earth wire to common earth dolly complete.
Supply & Fixing Modular Switches 5 /6 AMPS with fixing arrangements all as required and directed at site
Supply & Fixing Modular Switches 15 /16 AMPS with fixing arrangements all as required and directed at site
Supply & Fixing Modular Sockets 6 amps 3/5 pin with fixing arrangements all as required and directed at site
Supply & Fixing Modular Sockets 15/16 amps 5/6 pin with fixing arrangements all as required and directed at site
Supply & Fixing Ceiling Fan regulator modular electronic ROTARY / Step type 80/120 Watt capacity of ploycarbonate body ISI marked complete all as specified & directed.
Supply & Fixing Modular bell push switches 5 /6 AMPS with fixing arrangements all as required and directed at site
Supply & Fixing Modular Switches 5 /6 AMPS single pole two way with fixing arrangements all as required and directed at site
Supply & Fixing switch piano flush button type single pole one way 5 Amps of polycarbonate complete all as specified & directed.
Supply & fixing call bell ding dong sound type suitable for AC 240 volt single pole complete all as specified & directed.
Supply & Fixing switch bell push flush type suitable for 5 Amp 230 Volt of polycarbonate body complete all as specified & directed.
Supply & Fixing socket outlet 2 in 1, 5 Pin 5 Amp flush type of polycarbonate body complete all as specified & directed.
Supply & Fixing Switch socket combination 2 in 1, 3 pin / 5 Amp and 15 Amps flush type universal of polycabonate body complete all as specified & directed.
Supply & Fixing lamp holder / batten or angle holder Insulated body with back plate suitable for batten fittings complete all as specified & directed.
Supply & Fixing 9 Watt capacity LED lamp fixed in lamp holder complete all as specified & directed.Make :Bajaj,havells,surya
Supply & Fixing Ceiling rose surface type 60x30 mm three terminals of polycarbonate body complete all as specified & directed.
Supply & Fixing Ceiling Fan regulator electronic ROTARY / Step type 100 / 120 Watt capacity of ploycarbonate body ISI marked complete all as specified & directed.
Supply & Fixing Smart bright Batten Series, LED luminaire using LEDs 22 watt 110 LM/watt with diffuser which ensures uniform distribution and comfort batten series features latest LEDs and delivers consistent light output, stable color start Extruded Aluminum housing, Energy efficient, Flicker free start Inbuilt driver unit Suitable for wall and ceiling mounting using brackets (supplied along with The Luminaire has been tested as per Standard Specification IEC 60598-2-1 / IS: 10322(Parts/Secl), report has established conformity of the product(s) to the requirements of the Standard/Specification Make : Philips 0211 LED 22 S 6500/4000 PSUGR/ SI OR OSRAM
Supply & Fixing Ceiling light round shape surface mounted LED 10/12 WATT with dome shape opal diffuser compelete with fixing all as required and directed at site with copper conductor of suiyable size & length complete all as specified & directed. Make : Bajaj cat no BCCML12W WH /SURYA CAT NO SLEDLS 12WXX OR Havells Cat Part No.INTEGRANEOSURFACEDLS10WLED830S Equivalent make & model in Philips / Crompton
Supply & Fixing Bulk head endura LED light fitting complete with10 watt LED and making necessary electric connection to ceiling rose with copper conductor of suiyable size & length complete all as specified & directed. Make : Havells Cat Part No. RUGBY NEONFT10WLED760SSYMBOP/ BIBWP10W LED OF bAJAJ Equivalent SURYA SLEBLH 10 / Philips / Crompton
Supply & fixing in repair 45 to 50 watt watt LED security light fitting out door type with stove enamelled finish sheet aluminium housing with CRCA sheet steel reflector, ribbed acrylic bowl cover and accessories inlcuding 40 mm dia GI pipe light grade bracket fixed with 30x5 mm FI clamp with nut bolts & washers complete in all respect as specified & directed. MAKE- :SURYA CAT NO SLEUL45W OR BAJAJ CAT NO BRTFG 45W LED V2
Supply & fixing in repair 55 to 65 watt LED security light fitting out door type with stove enamelled finish sheet aluminium housing with CRCA sheet steel reflector, ribbed acrylic bowl cover and accessories with 40 mm dia GI pipe light grade bracket fixed including 30x5 mm FI clamp with nut bolts & washers complete in all respect as specified & directed. MAKE :SURYA CAT NO SLEUL 60 WATT /BAJAJ CAT NO BRTFG 60 WATT LED V3
S&F LED Decorative /mirror light fitting 9 watt along with fixture Surface mounted suitable for indoor aplication , connector block, etc . Complete with all accessories internally pre-wired and including round wood block, connecting up with three core flexible flexible copper conductor cable suitable size complete all as specified and directed by Engineer in charge. Make Surya Cat No SLE BT 10 W OR havells Cate no LUMILINEBS9WLED830SPCWH LUMIN Luker code no LMR 10 or Wipro or equvalent philips/syaska
Supply and fixing decorative wall light fitting WITH LAMPS 9 WATT made up of Polycarbonate, Cylindrical shape , with LED lamp complete with fixing arrangements on wall all as specified and directed. make CITY 1 OF HAVELLS /luker light code no LWL-110-2 or equivalent OR equivalents Bajaj/Philips/CG as approved by GE(I)
Supply & Fixing Indoor commercial recessed mounted luminaires energy efficient LED luminaire suitable for 600mm x 600mm for grid ceiling light not less than 36 watt with diffusers channel incluidng all accessories, internally pre-wired & making connection to ceiling rose with copper conductor of suitable size & length complete all as specified & directed. Make : Surya cat NO SLEFP 36 R22 or bAJAJ cAT NO BZRSQL36W/ WIPRO Cat Part No. CRCO10R036HP57G1 or Equivalent make & model in Philips or crompton
Supply & fixing in repair 20 watt LED security light fitting out door type with stove enamelled finish sheet aluminium housing with CRCA sheet steel reflector, ribbed acrylic bowl cover and accessories including 40 mm dia GI pipe light grade bracket fixed with 30x5 mm FI clamp with nut bolts & washers complete in all respect as specified & directed. MAKE: BAJAJ CAT NO BRLEP20WLED V2 OR SURYA CAT NO SLEUL20W OR OR PHILIPS/CROMPTON
S&F LED light fitting INDOOR TYPE of 15 to 18 watt along with fixture recessed slim LE luminaries mounting channel Luminaires ers, connector block, etc . Complete with all accessories internally pre-wired and including round wood block, connecting up with three core flexible flexible copper conductor cable suitable size complete all as specified and direc tedy by Enginmeer in charge. Make :SURYA CAT NO SLEDLR 15 W XX OR Havells Cat no Pulto1x1PLR15wlfd857s or Luker elegent slim panel LNPS30 or Wipro or philips/syaska
Supply & fixing in repair LED light down lighter die cast aluminum luminaire in powder coated white with drop down PC diffuser with optimised heat sink with repalaceable electronic driver complata recess or surface mounted 15 watt with fixing arrangemnts on ceiling with steel chain complete all as specified & directed. mkae SURYA CAT NO SLEDR 15 W STELER /Havells Cat No RISEDLR15WLED83OS or Bajaj/Philips make
Supply & fixing in repair LED 18/20 watt lamp high efficiency linear lamp complete all as specified & directed.make: surya ,bajaj,havells
Supply and fixing in repairs three phase static energy meter of accuracy class 1.0,3 x240v,50hz with backlit LCD display of rating 10-60 A (Suitable for measurement of KWH only) Make : HPL, Havells and equivalent
Supply & fixing in repair copper Ballast suitable for 36/40 Watt, 240 Volt tube light fittings complete all as specified & directed.
Supply & Fixing in repair single pole and netural sheet metal enclosure with a two pin and earth plug and socket complete with 01 number single pole MCB 20 Amps complete all as specified & directed.
Supply & Fixing in repair tube rod 36 watt 240 volt fitted in tube light fiitings complete all as specified & directed.
Supply and fixing in repairs 36 watt 4 pin lamps complete with fixing all as required and directed at site
S&F in repairs 36 watt ballast suitable CFL 36 watt lamps all as required and directed at site
S&F decorative wall mounted light fitting as persample fixing on wall suitable with lamps 7 watt per sample.Make: havells city 1,bajaj,surya
S&F in repairs Recess/ Surface mounted IP20 PIR movement detector with a built-in switch for lighting. It should be able to take lighting load of 6A. It should control office area of around 20sq.mtr for small movement and 50sq.mtr for large movements. It should have smart daylight sensing for additional savings through daylight override and daylight switching. It should have timer knob (1 to 30 min setting) and light detection knob (100 to 1500 Lux setting) on the bottom face for ease of controlling after installation as well. Smart timer should extend the delay time by 10 mins if movement is detected shortly after switch-off. It should have a retractable shield. Operating temperature +5 to +50 Degree Celsius. It should have EMC compliance IEC (EN) 60669-2-1, Immunity IEC (EN) 61547 And Immunity IEC (EN) 55015 & IEC (EN) 55022, Class B. Max power consumption of 1.2W at standby. Make: Philips LRM1071 or Bajaj/ Crompton
Supply & fixing in repairs electronic energy meter tamper proof design digital technology of 3 phase 3 x 240 volts 50 HZ 0.4% basic current for direct connected meter with LCD display class-1 accuracy as per IS : 13779 Microprocessor based single phase energy meter of 10--60 Amp / 5 Amp CT operated with CT with optical communication port complete with all accessories complete all as specified & directed at site make SECURE SPRINT 350 OR HPL socomec model or equivalent in Havells or as approved by GE.
Supply & fixing in repairs ectronic energy meter tamper proof design digital technology of SINGLE phase 1 x 240 volts 50 HZ 0.4% basic current for direct connected meter and 0.2% of basic current for CT operated meter with LCD display class-1 accuracy as per IS : 13779 Microprocessor based single phase energy meter of 10--60 Amp / 5 Amp CT operated with CT with optical communication port complete with all accessories complete all as specified & directed at site. Make :SARAL OF SECURE OR equivalent in,HPL Havells or as approved by GE.
Taking out old Unserviceable meter of any capacity after disconnecting the electric connection and refixing the electric meter new or old as directed of any capacity and making necessary electric connection and sealing the same with sealign wire and lead seal complete all as directed at site.
Taking down the old fitting 2x2 feet or 1x1 feet from ceiling safely and refixing the same after minor repair complete all as required and directed at site
S&F in repairs tube 14 watt complete all as required.Make:surya,bajaj,havells
S&F in repairs Bipin holder suItable for tube light fitting rotary type all as required and directed at site
Taking down old T-5 tube light 28 watt fitting and refixing the same after minor repair complete all as required and directed at site. Make: bajaj,surya
Supply & Fixing in repairs MCCB with thermal magnetic protection of 63 amps 415 volts 3 pole capacity complete all as specified & directed. Make : Legrand cat no DPX3 TP 420003 / Siemens/ GE/ABB
Supply & Fixing in repairs MCCB with thermal magnetic protection of 100 amps 415 volts 3 pole capacity complete all as specified & directed. Make : Legrand cat no DPX3 TP 420004 / Siemens/ GE/ABB
Supply and fixing in reparis copper wire 3 core round with sheathed 2.5 sqmm all as required An directed at site
Supply and fixing in replacemnt of mainswitch single pole with neutral link 32 amps complete with sheet steel enclosure and fixing on board all as required and directed at site
Supply and fixing in replacemnt of mains switchTriple pole with neutral link 32 amps complete with sheet steel enclosure and fixing on board all as required and directed at site
Supply and fixing in replacemnt of main switch single pole with neutral link 63 amps complete with fixing on board all as required and directed at site
Supply and fixing in replacemnt of main switch triple pole with neutral link 63 amps complete with fixing on board all as required and directed at site
Supply and fixing in replacemnt of main switch triple pole with neutral link 125 amps complete with fixing on board all as required and directed at site
S&F in repairs change over switch 63 amps TPNL on load type with sheet steel enclosure all as required and direct6ed at site
S&F in repairs change over switch 125 amps four on load type with sheet steel enclosure all as required and direct6ed at site
Supplying & fixing in repairs 1100 volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathed of PVC tape and over all PVC sheathed in service connection, one twin core 6 Sqmm stranded aluminium conductor cable flat or circular complete all as specified and directed.
Supplying & fixing in repairs 1100 volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathed of PVC tape and over all PVC sheathed in service connection, one twin core 10 Sqmm stranded aluminium conductor cable flat or circular complete all as specified and directed.
Supplying & fixing in repairs 1100 volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathed of PVC tape and over all PVC sheathed in service connection, one twin core 4 Sqmm stranded aluminium conductor cable flat or circular complete all as specified and directed.
Supply & fixing in repair Electronic Ballast suitable for 36/40 Watt, 240 Volt light fittings complete all as specified & directed.
Supply and fixing in repairs Modular Plate polycarbonate make suitable for fixing 5/15 AMP switches sockets and regulators complete etc all as specified and directed of Make : Anchor, Indoasian, Havells or equivalent
2 Module
3 Module
6 Moudle
8 Moudle
Supply and fixing in repairs Modular Box polycarbonate make suitable for fixing 5/15 AMP switches sockets and regulators complete all as specified and directed Make : Anchor, Indoasian, Havells or equivalent
2 Module
3 Module
6 Moudle
8 Moudle
Earthing complete with galvanised steel earthpipe of 3000mm long and 65mmouter x50mm inner dia laid in ground by drilling in the ground as required with filling the back fill compound complete with all as required and directed wit 4 mm dia GI wire and making the earth pit of PCC as per sample as required at site and testing after completion complete all as specified and directed.Make HP earth or eqvt
S&F blanking plate in modular switch board
S&F in repairs bed side lamp light fitting with lamps with LED lamps 9/10 watt with glass complete all as per sample
Supply & fixing in repair of cubical board of meter box of size 750 mm x 500 mm x 150 mm with 1.6 mm thick CRCA sheet cover with fabricating of required size welding moulding of required shape with suitable hinging device & providing locking arrangement with & including Godrej pattern locks five lever 65 mm size having three keys fixed in meter box with cutting the sheet in square shape / size of 100mm x 100mm (06 Nos) with providing transparent fibre sheet for looking the meter from outside and painting steel surface with grey colour synthetic enamel paint over a coat of red oxide primer and fixed on wall with required nut, bolts grouting on wall and making holes for connections complete all as specified & directed.
SONAL CONSTRUCTION AND ENGINEERS
ELCON
MAA SHARDA CONSTRUCTION
mandeka constructions
S K TRADERS
kiran electrical and hardware centre
ASHOKA ASSOCIATES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .