Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.5 LAccepted-Finance | L1 | Accepted-Finance Accepted | |
| 2 | L2₹26.6 L+₹2.1 L (8.49%)Accepted-Finance H NO 196 LAJPAT NAGAR FATEHABAD HARYANA 125050 | HISAR | HARYANA | 125050 | L2 | Accepted-Finance Accepted | |
| 3 | Not Admitted-Fee/PreQual/Technical VILLAGE LOHINA TEHSIL HODAL DISTRICT PALWAL 121106 | LOHINA | PALWAL | HARYANA | 121106 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹23.5 L
EMD Value
₹47,000
Closing Date
6 Jan 2020, 5:00 pmClosed
Executive Engineer
Executive Engineer Provincial Division PWD BandR Branch Faridabad
Special repair for renovation of Polyclinic at Sector 55, Faridabad in Faridabad District Civil and PH work only REINVITED
2019_HRY_113162_1
9249-9298
Open Tender
Civil Works - Buildings
Works
90 days
Sector 55 District Faridabad
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
Executive Engineer Provincial Division PWD BandR
₹47,000
25 Feb 2020
18 Dec 2019
8 Jan 2020
18 Dec 2019
6 Jan 2020
18 Dec 2019
Amount
Special repair for renovation of Polyclinic at Sector-55, Faridabad in Faridabad District REINVITED
Dismantling Brick work, Tile Masonry or Tile Lining and Tile Terracing in Cement [HSR 8.5 (b)]
Scraping- White wash and colour wash [HSR 8.32 (a)]
Cement concrete 1:2:4 with stone aggregate 20 mm nominal size in first storey upto 4 metres above plinth level [HSR 10.59]
First class brick work laid in cement, stone dust (from crusher) mortar 1:4 in first storey upto 4 metres above plinth level [HSR 11.29]
Corrugate G.I sheet roofing 0.80 mm thick fixed with galvanized iron ‘J’ or ‘L’ hooks, 10 mm dia G.I limpet and bitumen washers complete, excluding the cost of purlins, rafters and trusses [HSR 13.18]
Providing and fixing mineral fibre false ceiling tiles at all hieght of size 595x595 mm of approved texture, design and pattern. The tiles should have humidity resistance (RH) of 99%, light reflectance 285%, thermal conductivity K=0.052-0.057 w/m K, fire performance as per (BS 476 pt - 6&7) in true horizontal level suspended on inter locking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (Galvanized @ 120gms) comparsing of main T runners of 15x32 mm of length 1200 mm and secndary intermediate cross T of size 15x32 mm of length 600mm to form grid model of size 600x600 mm suspended from ceiling using glavanised mild steel item (glavanised @ 80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6mm diamter fully threded hanger rod upto 1000mm length and L shape level adjuster of size 85x25x2mm spaced at 1200mm entre to centre along main T. the system should rest on periphery walss/ partiotions with the help of GI perimeter wall angle of size 24x24x3000 mm made of 0.40mm thick sheet to be fixed to the wall with helop of plastic rawl plug at 450 mm centre to centre & 40mm long dry wall screws. The exposed bottom portion of all T-section used in false ceilding support system shall be pre-painted with polyster baked paint, for all heigthts. the work shall be carried out as per specification, drawings and as per direction of the Engineer-in-Charge. with of without grroves [HSR 13.92]
12 mm thick cement plaster 1:4 [HSR 15.5]
15 mm thick cement plaster 1:4 on the rough side of single or half brick wall [HR 15.10]
Applying priming coat with cement primer in all shades on newly plastered or concrete exterior surfaces [HSR 16.25]
Painting two coats with plastic emulsion paint on walls on new work to give an even shade [ HSR 16.30 ]
Providing two coats of exterior acrylic emulsion paint (b) Ist. Quality [HSR 16.79 (b)]
Providing and Applying two coats white cement based putty over plastered surface and grinding the surface smooth with sand paper to get an even and smooth finish including cost and carriage of all material, labour charges, scaffolding, sundries etc. complete (J.K. / Birla make) [HSR 16.81]
Providing and fixing aluminium work for doors windows, ventilators and partitions with extruded built up standard tubular sections appropriate Z sections and other sections of approved make conforming to IS 733 and IS : 1285 fixed with rawlplugs and screws or with fixing clips or with expansion hold fasterner including necessary fitting up of gaps at junction, at top, bottom and sides with required neoprene felt etc. aluminium sections shall be smooth, rust free straight mitred and jointed mechanically whereever required including cleat angle . Aluminium snap beading for glazing / panclling C.P. brass/stainless steel screws all complete. Fixed portion( Anodised Aluminium transparent or dyed to required shade according to IS: 1868 minium anodic coating of grade AC 15 ) [HSR 17.95]
Providing and fixing aluminium work for doors windows, ventilators and partitions with extruded built up standard tubular sections appropriate Z sections and other sections of approved make conforming to IS 733 and IS : 1285 fixed with rawlplugs and screws or with fixing clips or with expansion hold fasterner including necessary fitting up of gaps at junction, at top, bottom and sides with required neoprene felt etc. aluminium sections shall be smooth, rust free straight mitred and jointed mechanically whereever required including cleat angle . Aluminium snap beading for glazing / panclling C.P. brass/stainless steel screws all complete. Shutters of doors, windows & ventilation including providing and fixing hinges/ pivots and making provision for fixing of fittings whereever required including the cost of PVC /neoprene gasket required including aluminium fitting [HSR 17.96]
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 grade 1 type II in panelling fixed in aluminium doors windows shutters and partition frames with C.P. brass/stainless steel screws etc. complete . (b) Prelaminated particle board with decorative lamination on both side [HSR 17.97 (b)]
Providing and fixing glazing in Aluminium door , windows , ventilators , shutter and partition etc. PVC/neoprene gasket etc. complete ( cost of aluminium snap beading shall be paid in basis items ) [HSR 17.98 (b)]
Providing fixing aluminium round shape handle of outer dia 100 mm with screws etc. complete. (i) Anodised (AC -15 ) [ Aluminium [HSR 17.102 (i)]
Structural steel work in angles, tees and flats, welded including cutting fixing all gusset plates, bolts, nuts, welding rod, etc., with hoisting and erecting in positon for roof trusses, well kerbs, plates and trussed girders, etc., of any span for buildings and bridges [HSR 18.7]
Wrought iron and mild steel (using angles, flats square bars, tees and channels) ladders, grills, gratting frames, window guards, iron doors openable or fixed stair case or parapet or any other type of railing, gates and tree guards etc., including cost of screws and welding rods or bolts and nuts complete fixed in position [HSR 18.12]
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts,fasteners etc.) [NS]
Providing and fixing in position reinforced barbed type to support the punched type Concertina coil complete as per sketch including cost of screw and welding rod or bolts and nuts if required, fixed in position at the boundary complete as per directions of Engineer-in-charge [NS]
Providing & fixing Aluminum clip/bidding on the existing aluminum frame including all material and labour, complete in all respect as per direction of Engineer-in-Charge [NS]
Providing & fixing of EPDM rubber on the existing Aluminum frame including all material and labour complete in all respect as per direction of Ëngineer-in-Charge [NS]
Public Health Providing & fixing CP extension piece 15 mm 1-1/2" long nipple complete in all respect as per the directions of Engineer-in-charge [NS]
Providing & fixing CP long body bib cock with flange Parryware make G4706complete in all respect as per the directions of Engineer-in-charge [NS]
Providing & fixing CP Basin mixer G4715 A1 complete in all respect as per the directions of Engineer-in-charge [NS]
Providing & fixing CP Swan neck pillar cock G4768 A1 complete in all respect as per the directions of Engineer-in-charge [NS]
Providing & fixing CP angle valve with flange G4753 A1 of parryware make complete in all respect as per the directions of Engineer-in-charge [NS]
Providing & fixing slimline health faucet with hose & hook T9940 A1 of parryware make complete in all respect as per the directions of Engineer-in-charge [NS]
Providing & fixing EWC floor mounted Parryware cascade NXT range C8808/8807 of size 645x365x702 closet of white colour of parryware make complete in all respect as per the directions of Engineer-in-charge [NS]
Providing & fixing viterous chinaware washbasin cascade NXT C0407 of parryware make complete in all respect as per the directions of Engineer-in-charge [NS]
Providing & fixing CP bib cock with flange Parryware make G4704 A1 complete in all respect as per the directions of Engineer-in-charge [NS]
Providing & fixing connecting hose 1.5 ft T991299 of Parryware make complete in all respect as per the directions of Engineer-in-charge [NS]
Providing & fixing Bottle trap heavy 18" vertical pipe T3202 A1 of Parryware make complete in all respect as per the directions of Engineer-in-charge [NS]
Providing & fixing in position marilyn looking mirror of size 600x450mm of Parryware make complete in all respect as per the directions of Engineer-in-charge [NS]
Providing & fixing in position Paper holder with cover T6414 A1 of Parryware make complete in all respect as per the directions of Engineer-in-Charge [NS]
Providing and fixing HDPE Water storage tanks of Sintex, Diplast, O.K. Supreme make with covers/lids marked with IS:12701 on roof top of buildings including cost of hoisting and placing in position, making connection with inlet and outlet pipes, providing overflow or scour provisions with suitable plug on scour pipe including cost of nipples, washers, flanges for connections in tanks complete in all respect to the satisfaction of Engineer- in - charge.(HSR-30.119) 2000 Ltr. capacity)
Kamal Kumar Gera
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .