| Sl No | Description | Qty | Unit | OM SAI ELECTRICALS AND MACHINARY L5 | Mahendra Rewinding and Electricals Works L1 | Shree Rewinding Works L2 | Sakharkar Rewinding Works L3 | ST Rewinding Works Gondia L4 |
|---|---|---|---|---|---|---|---|---|
| 1.00Jet Pump,Monoblock Pump, Bare Pump Underwater Pum all Submit Rate as per GSDA-ITEM Sheet | ||||||||
| 1.01 | India Mark -2 & 3 Hand Pump Repairing Drive out the Pipe line with diameter of 65.0 mm. | 1 | Nos | 4,699 ₹4,699 | 4,680 ₹4,680 | 4,684 ₹4,684 | 4,685 ₹4,685 | 4,690 ₹4,690 |
| 1.02 | Drive out the Pipe line with diameter of 65.0 m.m which fell in well. | 1 | Nos | 4,843 ₹4,843 | 4,824 ₹4,824 | 4,828 ₹4,828 | 4,834 ₹4,834 | 4,834 ₹4,834 |
| 1.03 | Drive out the Pipe line with diameter of 32.0 m.m from which fell in well. | 1 | Nos | 4,130 ₹4,130 | 4,114 ₹4,114 | 4,118 ₹4,118 | 4,122 ₹4,122 | 4,122 ₹4,122 |
| 1.04 | Drive out the Pipe line with diameter of 32.0 m.m from well. | 1 | Nos | 2,380 ₹2,380 | 2,371 ₹2,371 | 2,373 ₹2,373 | 2,376 ₹2,376 | 2,376 ₹2,376 |
| 1.05 | To pull out the Stucked, fell or caught in drag Pump Set. ( Contractor use their own tools.) | 1 | Nos | 6,867 ₹6,867 | 6,840 ₹6,840 | 6,846 ₹6,846 | 6,846 ₹6,846 | 6,854 ₹6,854 |
| 1.06 | To increse or reduce the pipe line of Jet Pump inh well. ( For every 3.0 m. ) | 1 | Nos | 523 ₹523 | 521 ₹521 | 522 ₹522 | 522 ₹522 | 521 ₹521 |
| 1.07 | To fit new pump set (Upto 1.0 to 5.0 HP) in well/borewell , to give panel wiring earthig test report & start after electric supply. (Z.P. provides Pumpset panel, earthing material G.I. wire, plate, pipe and other assesaries.) | 1 | Job | 2,744 ₹2,744 | 2,733 ₹2,733 | 2,735 ₹2,735 | 2,735 ₹2,735 | 2,733 ₹2,733 |
| 1.08 | To rewinding electric motor with copper wire , above rate valid for without returning old copper wire, 1.0 HP to 5.0 HP open pump motor rewinding. | 1 | Nos | 3,514 ₹3,514 | 3,500 ₹3,500 | 3,500 ₹3,500 | 3,500 ₹3,500 | 3,507 ₹3,507 |
| 1.09 | To test electric pump on site ( transport and with minor repairing) | 1 | Nos | 3,012 ₹3,012 | 3,000 ₹3,000 | 3,003 ₹3,003 | 3,003 ₹3,003 | 3,006 ₹3,006 |
Tender Value
Refer Docs
EMD Value
₹27,000
Closing Date
19 Feb 2026, 5:00 pmClosed
Chief Executive Officer Z P Bhandara
Zilla Parishad Bhandara
Jet Pump, Monoblock Pump, Bare Pump, Underwater Pump VTPump India mark - 2 and Mark - 3 Hand Pump repairing and spare parts rate for Zilla Parishad Bhandara.
2026_BHAND_1277146_1
ZPBhand/GSDAJetP/ET6/140/25-26
Open Tender
Farm Machinery and Equipments
365 days
ZP Bhandara
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
₹27,000
9 Mar 2026
11 Feb 2026
20 Feb 2026
11 Feb 2026
19 Feb 2026
11 Feb 2026
Jet Pump,Monoblock Pump, Bare Pump Underwater Pum all Submit Rate as per GSDA-ITEM Sheet
India Mark -2 & 3 Hand Pump Repairing Drive out the Pipe line with diameter of 65.0 mm.
Drive out the Pipe line with diameter of 65.0 m.m which fell in well.
Drive out the Pipe line with diameter of 32.0 m.m from which fell in well.
Drive out the Pipe line with diameter of 32.0 m.m from well.
To pull out the Stucked, fell or caught in drag Pump Set. ( Contractor use their own tools.)
To increse or reduce the pipe line of Jet Pump inh well. ( For every 3.0 m. )
To fit new pump set (Upto 1.0 to 5.0 HP) in well/borewell , to give panel wiring earthig test report & start after electric supply. (Z.P. provides Pumpset panel, earthing material G.I. wire, plate, pipe and other assesaries.)
To rewinding electric motor with copper wire , above rate valid for without returning old copper wire, 1.0 HP to 5.0 HP open pump motor rewinding.
To test electric pump on site ( transport and with minor repairing)
To repaire panel board & starter of all types motor & Any HP control panel starter minor repairing to fit grip set, rotory switch, contactor plate, ampear meter, volt meter, on-off switch, fuse and minor wiring.
Starter panel board main repairing & to fit coil relay, single phasing preventer water label guard &Total wiring of 1.0 HP to 10.0 Hp pump.
Starter panel board main repairing & to fit coilrelay, single phasing
Preventer water label guard &Total wiring of 10.0 HP to 30 Hp pump.
Preventer water label guard & total wiring of 31.0 HP to 40 Hp pump.
To remove tin shed flushing of pump if necessary and fit as it is after work.
To remove handpump with pipeline for flushing and insert 10 feet G.I. pipeline towards 32 mm. dimeter& remove after flashing and fit handpump as it is before.
To remove handpump for capacity test and after testing fit as it is before.
Yield Test Single phase 1 HP to 2 Hp electric pump capacity test for regular three Hour with help of generator
Yield Test 1 HP to 2 Hp electric pump capacity test for regular three Hour without help of generator with necc equip
Yield Test 2 HP to 5 Hp electric pump capacity test for regular three Hour with help of generator with necc equipment
Yield Test 2 HP to 5 Hp electric pump capacity test for regular three Hour without help of generator with necc equip
i) Other material G.I. Coupling heavy duty 32 mm.
ii) G.I. Coupling heavy duty 40 mm.
iii) G.I. Coupling heavy duty 50 mm.
iv) G.I. Coupling heavy duty 65 mm.
v) G.I. Coupling heavy duty 75 mm.
vi) G.I. Coupling heavy duty 100 mm.
vii) G.I. Coupling heavy duty 125 mm.
viii) G.I. Coupling heavy duty 150 mm.
Bend heavy duty i) 32 mm.
iii) 50 mm.
vii) 125 mm.
viii) 150 mm.
3) Foot valve : i) 32 mm.
iii) 50 mm.
vii) 125 mm.
viii) 150 mm.
Wooden board 3 x 2 f x ½ “
Iron box 18 guage tin 3f x 2f x 1f
G.I.Pipe 1½“ / 1¼ “ cutting threding
G.I.Pipe 2“ cutting threding
G.I.Pipe 2½“ / 3 “ cutting threding
E) Submercible Motor Rewinding : 1.0 HP to 3.5 HP
4.0 HP to 5.0 HP
6.0 HP to 10.0 HP
11.0 HP to 15.0 HP
16.0 HP to 20.0 HP
21.0 HP to 30.0 HP
31.0 HP to 50.0 HP
F) To Remove Motor Pump Set with Pipeline from well: 1 HP to 6.0 HP
7.0 HP to 15 HP
16.0 HP to 30.0 HP
31.0 HP to 50.0 HP
G) To pull out the Stuck, fell or caught in dreg Pump Set with pipeline from well: 1) 1 HP to 6.0 HP
2) 7.0 HP to 15 HP
3) 16.0 HP to 30.0 HP
4) 31.0 HP to 50.0 HP
H) To fit motor pump in well with pipe line : 1) 1 HP to 6.0 HP
2) 7.0 HP to 15 HP
3) 16.0 HP to 30.0 HP
4) 31.0 HP to 50.0 HP
I) To increase or reduse pipeline of submercible pump in well Rate 3 meter / per pipe: 1 HP to 6.0 HP
7.0 HP to 15 HP
16.0 HP to 30.0 HP
31.0 HP to 50.0 HP
J) To submit in the office pump, : 1 HP to 7.5 HP
8.5 HP to 15 HP
16.0 HP to 30.0 HP
31.0 HP to 50.0 HP
K) New pump set (Upto 1.0 to 5.0 HP) : 1 HP to 7.5 HP
8.5 HP to 15 HP
16.0 HP to 30.0 HP
31.0 HP to 50.0 HP
L) To open sub motor, repairing, fitting and testing.: 1 HP to 7.5 HP
8.5 HP to 15 HP
16.0 HP to 30.0 HP
31.0 HP to 50.0 HP
M) To open sub pump, repairing, fitting and testing.: 1) 1 HP to 7.5 HP
2) 8.5 HP to 15 HP
3) 16.0 HP to 30.0 HP
4) 31.0 HP to 50.0 HP
N) To repaire sub motor and sub pump:To sub motor / pump bush fitting per
Damage stater repairing
Rotorshaft turning and polishing
Damage Rotor repairing (Rewinding)
Sub pump shaft turning & polishing
To joint cable with kit
O) Sub motor & sub pump spare parts1 to 5 HP: i) Sub motor bush
ii) Sub pump bush
Thrust Bearing block
Thrust Bearing full
Block
Upper stage casing
Lower stage casing
Middle stage casing
i) Impeller
ii) Brass Impeller
Neck ring
Diffuser
Pump key
Rubber parts kit
Submersible Motor base
Strainer
Male- Female bush
Male- Famale key
NRV stage casing
Stud big
Stud small
Motor bush housing
i) Upper
ii) Lower
Allen srew
SS Sleeve motor /pump
SS Sleeve cover
O) Sub motor & sub pump spare parts1 to 7.5 HP: i) Sub motor bush
ii) Sub pump bush
Thrust Bearing block
Thrust Bearing full
Block
Upper stage casing
Lower stage casing
Middle stage casing
i) Impeller
ii) Brass Impeller
Neck ring
Diffuser
Pump key
Rubber parts kit
Submersible Motor base
Strainer
Male- Female bush
Male- Famale key
NRV stage casing
Stud big
Stud small
Motor bush housing
i) Upper
ii) Lower
Allen srew
SS Sleeve motor /pump
SS Sleeve cover
O) Sub motor & sub pump spare parts 8 to15 HP : i) Sub motor bush
ii) Sub pump bush
Thrust Bearing block
Thrust Bearing full
Block
Upper stage casing
Lower stage casing
Middle stage casing
i) Impeller
ii) Brass Impeller
Neck ring
Diffuser
Pump key
Rubber parts kit
Submersible Motor base
Strainer
Male- Female bush
Male- Female key
NRV stage casing
Stud big
Stud small
Motor bush housing
i) Upper
ii) Lower
Allen srew
SS Sleeve motor /pump
SS Sleeve cover
O) Sub motor & sub pump spare parts 16 to30 HP: i) Sub motor bush
ii) Sub pump bush
Thrust Bearing block
Thrust Bearing full
Block
Upper stage casing
Lower stage casing
Middle stage casing
i) Impeller
ii) Brass Impeller
Neck ring
Diffuser
Pump key
Rubber parts kit
Sub motor base
Strainer
Male- Female bush
Male- Famale key
NRV stage casing
Stud big
Stud small
Motor bush housing i) Upper
ii) Lower
Allen srew
SS Sleeve motor /pump
SS Sleeve cover
1) Three ply core flat flexible submersible cable: i) 1.5 sq.mm.
ii) 2.5 sq.mm.
iii) 4 sq.mm.
iv) 6 sq.mm.
v) 10 sq.mm.
vi) 1.5 sq.mm.
1) Three ply core flat : Arm cable : i) 1.00 sq.mm.
ii) 1.50 sq.mm.
iii) 2.50 sq.mm.
iv) 4.00 sq.mm.
v) 6.00 sq.mm.
vi) 10.00 sq.mm.
vii) 16.00 sq.mm.
viii) 25.00 sq.mm.
ix) 35.00 sq.mm.
x) 50.00 sq.mm.
Copper wire P.V.C. insulated & P.V.C. coated: i) 3/20
Copper wire P.V.C. insulated & P.V.C. coated: ii) 7/20
Copper wire P.V.C. insulated & P.V.C. coated: iii) 7/16
27) New Pump Shaft i) 1.5 HP to 6 HP
27) New Pump Shaft ii) 7.5 HP to 15 HP
27) New Pump Shaft iii) 16 HP to 30 HP
Borewell Protecting Plate
Borewell Protecting Cap
P) 25.0 HP to 40 HP V.T. Motor pump set repairing 25HP: Drive out V.T. Motor from well
V.T. Pump fit in well
Drive out Column assembly with pipeline from well
To fit Column assembly with pipeline in well
To open V.T. Motor
V.T. Motor fitting & testing
Bowl assembly fitting & testing
To open bowl assembly
V.T. Pump rewinding with copper wire. Without returning old copper wire
Allignment checking & repairing i) Line shaft
ii) Column pipe
iii) Oil tube
Cutting & Threading i) Line shaft (R.H./L.H)
ii) Column pipe (R.H./L.H)
iii) Oil tube (R.H./L.H)
To fit new Flange, threading collar, welding, nutbolt in Column pipe
To Making ,Bearing sheet on lathe machine
Bearing plate both side
P) 25.0 HP to 40 HP V.T. Motor pump set repairing 35HP: Drive out V.T. Motor from well
V.T. Pump fit in well
Drive out Column assembly with pipeline from well
To fit Column assembly with pipeline in well
To open V.T. Motor
V.T. Motor fitting & testing
Bowl assembly fitting & testing
To open bowl assembly
V.T. Pump rewinding with copper wire. Without returning old copper wire
Allignment checking & repairing i) Line shaft
ii) Column pipe
iii) Oil tube
Cutting & Threading i) Line shaft (R.H./L.H)
ii) Column pipe (R.H./L.H)
iii) Oil tube (R.H./L.H)
To fit new Flange, threading coller, welding, nutbolt in Column pipe
To Making ,Bearing sheet on lathe machine
Bearing plate both side
P) 25.0 HP to 40 HP V.T. Motor pump set repairing 40HP : Drive out V.T. Motor from well
V.T. Pump fit in well
Drive out Column assembly with pipeline from well
To fit Column assembly with pipeline in well
To open V.T. Motor
V.T. Motor fitting & testing
Bowl assembly fitting & testing
To open bowl assembly
V.T. Pump rewinding with copper wire. Without returning old copper wire
Allignment checking & repairing i) Line shaft
ii) Column pipe
iii) Oil tube
Cutting & Threading i) Line shaft (R.H./L.H)
ii) Column pipe (R.H./L.H)
iii) Oil tube (R.H./L.H)
To fit new Flange, threading coller, welding, nutbolt in Column pipe
To Making ,Bearing sheet on lathe machine
Bearing plate both side
Q) 25 HP to 40 HP V.T. Pump Spare Part 25HP : 1) V.T. MotorBearing i) Upper
ii) Lower
Discharge & sectioncaseBearing bush gun metal
Water seal (Oil water separater)
Line Shaft
Oil Tube
T.T. Plate cast iron
Brain rubber bush (spider)
Net (cast iron)
Nut bolt ¾“ x 2 “
Nut bolt ¾“ x 6 “
Rubber Seat
T.T. Plate Bush
Neck Ring (Gun Metal)
Impeller (Gun Metal)
Browl assembly casing
6” Column pipe M.s.
8” Column pipe M.s.
Transformer Oil
Pump Colet
Shaft Tube Oil 10 no.
Impeller pump shaft
Latern Ring
Guide spider
Column Pipe Coupling
Line shaft Coupling
Oil tube Bearing
Gland nut
Top Oil Tube
SpiderBearing Bush
Guide Spider Rubber Bush with Sirclip
Rubber Bush/Bearing
Line Shaft Sleeve S.S.
Water Lubricating Tube
Stuffing Box Bush & with gaskit
Stuffing Box Bearing
Latern Ring
Sole Plate
Base Plate
Water Deflector
Q) 25 HP to 40 HP V.T. Pum Spare Part 25HP : 1) V.T. Motor Bearing
i) Upper
ii) Lower
Discharge & section case Bearing bush gun metal
Water seal (Oil water separater)
Line Shaft
Oil Tube
T.T. Plate cast iron
Brain rubber bush (spider)
Net (cast iron)
Nut bolt ¾“ x 2 “
Nut bolt ¾“ x 6 “
Rubber Seat
T.T. Plate Bush
Neck Ring (Gun Metal)
Impeller (Gun Metal)
Browl assembly casing
6” Column pipe M.S.
8” Column pipe M.S.
Transformer Oil
Pump Colet
Shaft Tube Oil 10 no.
Impeller pump shaft
Latern Ring
Guide spider
Column Pipe Coupling
Line shaft Coupling
Oil tube Bearing
Gland nut
Top Oil Tube
Spider Bearing Bush
Guide Spider Rubber Bush with Circlip
Rubber Bush/Bearing
Line Shaft Sleeve S.S.
Water Lubricating Tube
Stuffing Box Bush & with gasket
Stuffing Box Bearing
Latern Ring
Sole Plate
Base Plate
Water Deflector
Q) 25 HP to 40 HP V.T. Pum Spare Part 40HP: 1) V.T. Motor Bearing i) Upper
ii) Lower
Discharge & section case Bearing bush gun metal
Water seal (Oil water separater)
Line Shaft
Oil Tube
T.T. Plate cast iron
Brain rubber bush (spider)
Net (cast iron)
Nut bolt ¾“ x 2 “
Nut bolt ¾“ x 6 “
Rubber Seat
T.T. Plate Bush
Neck Ring (Gun Metal)
Impeller (Gun Metal)
Browl assembly casing
6” Column pipe M.S.
8” Column pipe M.S.
Transformer Oil
Pump Colet
Shaft Tube Oil 10 no.
Impeller pump shaft
Latern Ring
Guide spider
Column Pipe Coupling
Line shaft Coupling
Oil tubeBearing
Gland nut
Top Oil Tube
Spider Bearing Bush
Guide Spider Rubber Bush with Sirclip
Rubber Bush/Bearing
Line Shaft Sleeve S.S.
Water Lubricating Tube
Stuffing Box Bush & with gaskit
Stuffing BoxBearing
Latern Ring
Sole Plate
Base Plate
Water Deflector
i) Drive out 1 HP to 3 HP Monoblock Pump
ii) Drive out 4 HP to 10 HP Monoblock Pump
iii) Drive out 10 HP to 30 HP Monoblock Pump
ii) 1 to 3 HP Monoblock Motor Rewinding
iii) 4 to 5 HP Monoblock Motor Rewinding
iv) 6 to 7½ HP Monoblock Motor Rewinding
v) 8 to 10 HP Monoblock Motor Rewinding
vi) 10 to 15 HP Monoblock Motor Rewinding
Monoblock Pump Open, Repairing, Fitting & Testing i) 1 to 3 HP
Monoblock Pump Open, Repairing, Fitting & Testing ii) 3 to 5 HP
Monoblock Pump Open, Repairing, Fitting & Testing iii) 6 to 10 HP
Monoblock Pump Open, Repairing, Fitting & Testing iv ) 10 to 15 HP
RotorPump Shaft Turning & Polishing i) 1 to 5 HP
Rotor Pump Shaft Turning & Polishingii) 6 to 10 HP
Rotor Pump Shaft Turning & Polishingii) 11 to 20 HP
To make Monoblock Pump Bush & Housing (Bearing ) i) 1 to3 HP
To make Monoblock Pump Bush & Housing (Bearing ) ii) 3 to 5 HP
To make Monoblock Pump Bush & Housing (Bearing ) iii) 6 to 10 HP
To make Monoblock Pump Bush & Housing (Bearing ) iii) 11 to 15 HP
To Fit New Pump Set i) 1 to 3 HP
To Fit New Pump Set ii) 3 to 5 HP
To Fit New Pump Set iii) 6 to 10 HP
To Fit New Pump Set iii) 10 to 15 HP
T) Monoblock Pump Spare Parts Bearing 1 to 1.5 HP(Driving side)
Bearing (Driven side)
Impeller Key
Pump Bush
Air Fan
Star-Nut Key
Bearing Plate both side 1 item
Water seal
Gland Rope
Gland Bush
Gland Plate
Rotorfitted shaft
Latern Ring
Brass Impeller
Impeller C.I.
Diffuser
Bearing housing
Neck Ring
Foot valve
Flange (Delivery/ suction)
Shaft Sleeve
Delivery casing
Stater Fitted motorbody
Spacer
Fan cover
Water Deflector
T) Monoblock Pump Spare Parts 2 to 3 HP Bearing (Driving side)
Bearing (Driven side)
Impeller Key
Pump Bush
Air Fan
Star nut Key
Bearing Plate both side
Water seal
Gland Rope
Gland Bush
Gland Plate
Rotorfitted shaft
Latern Ring
Brass Impeller
Impeller C.I.
Diffuser
Bearing housing
Neck Ring
Foot valve
Flange (Delivery/ suction)
Shaft Sleeve
Delivery casing
Stater Fitted motorbody
Spacer
Fan cover
Water Deflector
T) Monoblock Pump Spare Parts 4 to 5 HP Bearing (Driving side)
Bearing (Driven side)
Impeller Key
Pump Bush
Air Fan
Star-Nut Key
Bearing Plate both side
Water seal
Gland Rope
Gland Bush
Gland Plate
Rotorfitted shaft
Latern Ring
Brass Impeller
C.I. Impeller
Diffuser
Bearing housing
Neck Ring
Foot valve
Flange (Delivery/ suction)
Shaft Sleeve
Delivery casing
Stater Fitted motorbody
Spacer
Fan cover
Water Deflector
T) Monoblock Pump Spare Parts Bearing 6 to 7½HP (Driving side)
Bearing (Driven side)
Impeller Key
Pump Bush
Air Fan
Star-Nut Key
Bearing Plate both side
Water seal
Gland Rope
Gland Bush
Gland Plate
Rotor-fitted shaft
Latern Ring
Impeller brass
Impeller C.I.
Diffuser
Bearing housing
Neck Ring
Foot valve
Flange (Delivery/ suction)
Shaft Sleeve
Delivery casing
Stater Fitted motorbody
Spacer
Fan cover
Water Deflector
T) Monoblock Pump Spare Parts Bearing 8 to 10HP (Driving side)
Bearing (Driven side)
Impeller Key
Pump Bush
Air Fan
Star-Nut Key
Bearing Plate both side
Water seal
Gland Rope
Gland Bush
Gland Plate
Rotor fitted shaft
Latern Ring
Impeller brass
Impeller C.I.
Diffuser
Bearing housing
Neck Ring
Foot valve
Flange (Delivery/ suction)
Shaft Sleeve
Delivery casing
Stater Fitted motor body
Spacer
Fan cover
Water Deflector
U) Monoblock Pump Spare Parts Bearing 11 to 15HP (Driving side)
Bearing (Driven side)
Impeller Key
Pump Bush
Air Fan
Star-Nut Key
Bearing Plate both side
Water seal
Gland Rope
Gland Bush
Gland Plate
Rotor fitted shaft
Latern Ring
Impeller brass
Impeller C.I.
Deffuser
Bearing housing
Neck Ring
Foot valve
Flange (Delivery/ suction)
Shaft Sleeve
Delivery casing
Stater Fitted motor body
Spacer
Fan cover
Water Deflector
U) Bare Pump Repairing To drive out bare pump i) 10 to 20 HP
ii) 21 to 50 HP
Bare Pump to open, repairing, fitting & Testing i) 10 to 20 HP
ii) 21 to 50 HP
Pump shaft turning & polishing i) 10 to 20 HP
ii) 21 to 50 HP
To make pump bush & housing (Bearing ) i) 10 to 20 HP
ii) 21 to 50 HP
To fit new bare pump i) 10 to 20 HP
ii) 21 to 50 HP
Pump repairing & fitting i) 10 to 20 HP
ii) 21 to 50 HP
To make gland bush housing i) 10 to 20 HP
ii) 21 to 50 HP
Drive out bare pump pipe line with foot valve i) 10 to 20 HP
ii) 21 to 50 HP
To fit bare pump pipeline with foot valve i) 10 to 20 HP
ii) 21 to 50 HP
V) Bare Pump spare parts 10 to 15 HPBearing (BallBearing )
Roller Bearing
Impeller Key
Pump bush
Stud nut
Nut bolt kit
Air cock
Base plate
Water seal
Gland bush
Gland plate
Pump shaft
Latern Ring
Impeller Brass
Impeller (C.I)
Diffuser
Bearing housing
Neck ring (small)
Neck ring (big)
Flasher
Foot valve
Check nut
Impeller housing
Rotor casing
Rotor
Delivery casing
Stuffing box bush
Shaft Sleeve
Water deflector
Coupling half flexible
Bearing cover
Grease cup
Flange section/ delivery
V) Bare Pump spare parts 16 to 20HPBearing (BallBearing )
Roller Bearing
Impeller Key
Pump bush
Stud nut
Nut bolt kit
Air cock
Base plate
Water seal
Gland bush
Gland plate
Pump shaft
Latern Ring
Brass Impeller
Impeller(C.I)
Diffuser
Bearing housing
Neck ring (small)
Neck ring (big)
Flasher
Foot valve
Check nut
Impeller housing
Rotor casing
Rotor
Delivery casing
Stuffing box bush
Shaft Sleeve
Water deflector
Coupling half flexible
Bearing cover
Grease cup
Flange section/ delivery
V) Bare Pump spare parts 21 to 50 HPBearing (BallBearing )
Rolor Bearing
Impeller key
Pump bush
Stud nut
Nut bolt kit
Air cock
Base plate
Water seal
Gland bush
Gland plate
Pump shaft
Latern Ring
Impeller brass
Impeller (C.I)
Diffuser
Bearing housing
Neck ring (small)
Neck ring (big)
Flasher
Foot valve
Check nut
Impeller housing
Rotor casing
Rotor
Delivery casing
Stuffing box bush
Shaft Sleeve
Water deflector
Coupling half flexible
Bearing cover
Grease cup
Flange section/ delivery
W) Bare Motor repairing Drive out bare motor
W) Bare Motor repairing Drive out bare motor i) 10 to 20 HP
W) Bare Motor repairing Drive out bare motor ii) 21 to 50 HP
Bare motor rewinding i) 1 to 5 HP
Bare motor rewinding ii) 6 to 10 HP
Bare motor rewinding iii) 11 to 15 HP
Bare motor rewinding iv) 16 to 20 HP
Bare motor rewindingv) 21 to 30 HP
Bare motor rewinding vi) 31 to 35 HP
Bare motor rewinding vii) 36 to 40 HP
Bare motor rewinding viii) 41 to 50 HP.
Motor opening, over oiling, fitting & testingi) 1 to 5 HP
Motor opening, over oiling, fitting & testing ii) 6 to 10 HP
Motor opening, over oiling, fitting & testing iii) 11 to 15 HP
Motor opening, over oiling, fitting & testing iv) 16 to 20 HP
Motor opening, over oiling, fitting & testing v) 21 to 30 HP
Motor opening, over oiling, fitting & testing vi) 31 to 35 HP
Motor opening, over oiling, fitting & testing vii) 36 to 40 HP
Motor opening, over oiling, fitting & testing viii) 41 to 50 HP.
Rotor shaft turning & polishing i) 1 to 5 HP
Rotor shaft turning & polishing ii) 6 to 10 HP
Rotor shaft turning & polishing iii) 11 to 15 HP
Rotor shaft turning & polishing iv) 16 to 20 HP
Rotor shaft turning & polishing v) 21 to 30 HP
Rotor shaft turning & polishing vi) 31 to 35 HP
Rotor shaft turning & polishing vii) 36 to 40 HP
Rotor shaft turning & polishing viii) 41 to 50 HP.
To make motor bush & housing (Bearing Seat) i) 1 to 5 HP
To make motor bush & housing (Bearing Seat) ii) 6 to 10 HP
To make motor bush & housing (Bearing Seat) iii) 11 to 15 HP
To make motor bush & housing (Bearing Seat) iv) 16 to 20 HP
To make motor bush & housing (Bearing Seat) v) 21 to 30 HP
To make motor bush & housing (Bearing Seat) vi) 31 to 35 HP
To make motor bush & housing (Bearing Seat) vii) 36 to 40 HP
To make motor bush & housing (Bearing Seat) viii) 41 to 50 HP.
To fit new motor i) 1 to 5 HP
To fit new motor ii) 6 to 10 HP
To fit new motor iii) 11 to 15 HP
To fit new motor iv) 16 to 20 HP
To fit new motor v) 21 to 30 HP
To fit new motor vi) 31 to 35 HP
To fit new motor vii) 36 to 40 HP
To fit new motor viii) 41 to 50 HP.
Panel board & Starter repairing i) 1 to 5 HP
Panel board & Starter repairing ii) 6 to 10 HP
Panel board & Starter repairing iii) 11 to 15 HP
Panel board & Starter repairing iv) 16 to 20 HP
Panel board & Starter repairing v) 21 to 30 HP
Panel board & Starter repairing vi) 31 to 35 HP
Panel board & Starter repairing vii) 36 to 40 HP
Panel board & Starter repairing viii) 41 to 50 HP.
To fit motor as it is i) 1 to 5 HP
To fit motor as it is ii) 6 to 10 HP
To fit motor as it is iii) 11 to 15 HP
To fit motor as it is iv) 16 to 20 HP
To fit motor as it is v) 21 to 30 HP
To fit motor as it is vi) 31 to 35 HP
To fit motor as it is vii) 36 to 40 HP
To fit motor as it is viii) 41 to 50 HP.
X) Bare Motor spare parts 10 to 15 : Bearing
Air fan
Shaft
Bearing plate
Motor bush
Rotor assembly
Stud nut kit
Nut bolt kit
X) Bare Motor spare parts 6 to 20 : Bearing
Air fan
Shaft
Bearing plate
Motor bush
Rotorassembly
Stud nut kit
Nut bolt kit
X) Bare Motor spare parts 21 to 50 : Bearing
Air fan
Shaft
Bearing plate
Motor bush
Rotor assembly
Stud nut kit
Nut bolt kit
Y) Vaccum Pump Repairing Drive out pump i) 1 to 3 HP
Y) Vaccum Pump Repairing Drive out pump ii) 4 to 5 HP
Motor Rewinding i) 1 to 3 HP
Motor Rewinding ii) 4 to 5 HP
Pump opening, repairing, over oiling, fitting & testing i) 1 to 3 HP
Pump opening, repairing, over oiling, fitting & testing ii) 4 to 5 HP
Rotor shaft turning & polishing i) 1 to 3 HP
Rotor shaft turning & polishing ii) 4 to 5 HP
To make Vaccum pump bush &Bearing housing i) 1 to 3 HP
To make Vaccum pump bush &Bearing housing ii) 4 to 5 HP
To fit new pump set i) 1 to 3 HP
To fit new pump set ii) 4 to 5 HP
Panel board & starter repairing i) 1 to 3 HP
Panel board & starter repairing ii) 4 to 5 HP
Z) Vaccum Pump Spare Parts 1 to 3 HP : Bearing
Impeller Key
Pump bush
Air fan
Star nut key
Bearing plate both side
Mechanical seal
Gland rope
Gland bush
Gland plate
Rotor fitted shaft
Latern Ring
Rotor G.M.
Fan cover
Spacer
Bearing housing
Neck Ring
Port plate
Flange (Delivery/ section)
Shaft Sleeve
Suction & delivery chember
Starter fitted motorbody
Tie rod
Rotor casing
Liquid diflector
Z) Vaccum Pump Spare Parts 4 to 5 HP : Bearing
Impeller Key
Pump bush
Air fan
Star nut key
Bearing plate both side
Mechanical seal
Gland rope
Gland bush
Gland plate
Rotor-fitted shaft
Latern Ring
Rotor G.M.
Fan cover
Spacer
Bearing housing
Neck Ring
Port plate
Flange (Delivery/ section)
Shaft Sleeve
Suction & delivery chember
Starter fitted motorbody
Tie rod
Rotor casing
Liquid deflector
Starter Relay i) 6 to 10 A.
ii) 9 to 14 A.
iii) 13 to 21 A
iv) 19 to 27 A
Starter no volt & over load coil
Contactor set full i) S. K. -1
iii) M.L. -2
vii) M.L. - 6
viii) M.L. - 7
Relay plate (kit)
Contactor point kit i) S. K. -1
iii) M.L. -2
vii) M.L. - 6
viii) M.L. - 7
i) Fuse grip 16 A.
ii) Fuse grip 32 A.
iii) Fuse grip 63 A.
iv) Fuse grip 100 A
v) Fuse grip 200 A..
Fuse Base i) 16 A.
Connector Plate i) Volt meter 0-440 Volt small
ii) Volt meter 0-440 Volt Big
Ampere meter i) 0 to 15 A.
ii) 0 to 50 A.
iii) 0 to 100 A.
Capasitor 1 K.V.A.R.
Single Phasing Preventor
Water Level Guard with 60 M. wire
On-Off Rotory switch
Volt meter /Ampereee meter switch
Nuon Indicator Lamp
Main Switch 440 Volt three phase i) 16 A.
M.C.C.B. Unit i) 32 A.
H.R. C. Fuse i) 100 A.
Auxiilary Coil
Timer Coil
C.T. coil i) 60 A.
Tunge Tester
Multi meter
Insulation Tester
Meger
Hand gloves - 1 pair (Rubber)
Insulated Rubber Matting
To Earthing with arthing 300 x 300 x 50 mm. earthing plate, G I. pipe & earthing wire
To Earthing with earthing 450 x 450 x 50 mm. earthing plate, G I. pipe & earthing wire
Earthing wire 14 to 6 guage
Starter D.O.L
i) 1 to 5 HP
ii) 5 to 10 HP
iii) Star Delta auto 10 to 20 HP
vi) Star Delta auto 21 to 30 HP
v) Auto transformer starter 20 to 30 HP
vi) Auto transformer starter 31 to 50 HP
transformer coil rewinding with copper wire in transformer starter. without returning old copper wire.
Change over switch 50 A. 3 phase
Change over switch 100 A. 3 phase
Change over switch 200 A. 3 phase
Bus bar 30 to 50 HP
Transformer Oil
1) :- Providing, erecting and giving test of 100 mm dia. submersible pump sets confirming to IS 8034 and motor confirming IS 9283. Pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and Motor suitable for working on 415 V± 10%, 3Ph, 50 Hz., A.C. supply, Cable guard, thrust carbon/fibre bearing to accept entire hydraulic thrust, water proof winding shall be provided. The pump set shall be suitable for direct coupling. Pump shall have suitable suction stainer shall also be provided. 3 core, single/double run copper conductor submersible type flat cable 3 Mtr. and 3 pairs of erection clamps. Rates per pump upto 20 stages (as per design) 1.0 HP
Submersible pump 150 mm dia (with bronze /Stainless (CF8M) impeller) up to 8 stages 1.0 HP
Submersible pump 150 mm dia (with bronze /Stainless (CF8M) impeller) up to 12 stages 10.0 HP
Submersible pump 150 mm dia (with bronze /Stainless (CF8M) impeller) up to 15 stages 17.5 HP
Submersible Pump 200mm dia (withBronze / Stainless steel (CF8M) Impeller)upto5 stages of category A & B 7.5 HP
Submersible Pump 200mm dia (with Bronze /Stainless steel (CF8M) Impeller)upto 8 stages of category A & B 15 HP
Submersible Pump 250mm dia (withBronze / Stainless steel(CF8M) Impeller)upto8 stages of category A & B 15 HP
Providing, erecting and giving test of submersible pump set conforming to IS 8034 and motor conforming toIS 8967-8986 with waterproof winding. Pump shall be suitable for various delivery head and dIsc harge with stainless steel shaft. Motor suitable for working on 415 V + 10%, 3 Ph, 50 Hz A.C. Su pply, with ca ble guard, thrustcarbon / fibre bearing to withstand entire hydraulic thrust. The pump set shall be suitable for direct coupling, with suitable suction trainer. Pump s hould have suitable discharge outlet as per man ufac t mer’s des ign. Antithruststreamlined non return valve s haII be provided with the pump. 3 m submersible c opper cond‹ictor cable in single / double run and 2 pairs of s uitable s ize erection clamp10 mm thick shall be provided with each pump..Submersible Pump 250 mm dia. (with Bronze / Stainless steel CF8M) impeller up to 8 stages of catagory A & B 35 HP
Supply rate should be increase per stage more than 8 Stage
Supply rate should be increase per stage more than 8 Stage
Supply rate should be increase per stage more than 8 Stage
Supply rate should be increase per stage more than 8 Stage
Supply rate should be increase per stage more than 8 Stage
Submersible Monoblock (with bronze / stainless steel (CF8M) Impeller ) Horizontal/vertical -upto 3 stages ( Motor with water lubricated bearing to accept entire hydraulice threst ) 3.0 HP
V.T. Pump erection charges (For column length up to 6 m. Erecting, commissioning and giving test of Vertical Turbine giving test of Vertical Turbine Pump (Water Lubricated) including bowl assembly and dischargeheadetconprovided channel / RSJ / RCC beam including erecting on provided sole plate with blue matching. Up to 30 HP
31 HP to 100 HP
101 HP to 200 HP
201 HP to 300 HP
above 300 HP
Sewage Pumps-SupplyingNon clog SubmersiblePumpsuitable for sewage/ Liquid waste applicationwithstandardMOC and given duty points as below head upto 10 m 1 HP (Up to 9000 LPH)
2 HP (Up to 12000 LPH
3 HP (Up to 18000 LPH
5 HP (Up to 35000 LPH)
7.5 HP (Up to 72000 LPH)
10 HP (Up to 90000 LPH)
15 HP (Up to 132000 LPH) E
20 HP (Up to 192000 LPH)
25 HP (Up to 228000 LPH
30 HP (Up to 240000 LPH)
35 HP (Up to 276000 LPH
Sewage Pump, Erection charges Erection and giving test and trial for directly coupled sewage pump set on provided foundation. Up to 30 HP
31 HP to 100 HP
101 HP to 200 HP
201 HP to 300 HP
above 300 HP
Supplying and erecting submersible pumpset 0.75kw/ 1HP with 415v 50 cycles ac supply suitable for 100 mm dia borewell . suitable for 10 to 50 LPM Discharge at 70 to 20 M and ( Max Effciency at 52 m. head 30 LPM discharge) & delivery pipe of 32 mm diameter with a neccssary H. type clamp as per specification No. WP. SMP
Suppluing and erecting 3 core pvc. insulated flat flexible submersible cable with Copper Conductor, PVC insulated and PVC sheathed 3core 1.5 sq.mm
3core 2.5 sq.mm
3core 4 sq.mm
3core 6 sq.mm
Providing, suplying & in standard lenghts MDPE Pipes. Conforming to I.S.O. 4427:1996/with necessary jointing material like mechanical connection I.e. thread/insert joint/quick release coupler joint/compresion fitting joint or flanged joint. ...............etc complete. PN-16 SDR - 9 20 mm dia
Providing ISI mark GI pipe with one coupler of following class and dia including all local and central taxces, octroi, inspection charges, transportation to stores etc. complete. IS 1239/2004 15 mm dia Medium
20 mm dia Medium
25 mm dia Medium
32 mm dia Medium
40 mm dia Medium
50 mm dia Medium
65 mm dia Medium
80 mm dia Medium
100 mm dia Medium
125 mm dia Medium
150 mm dia Medium
Lowering, laying, jointing G.I. pipes and specials of following class and dia. including conveyance from stores to site of works, all labour, giving satisfctory hydraulic testing etc. complete. Either underground or in vertical position, as directed by Engineer-in-charge. 15 mm dia Medium
20 mm dia Medium
25 mm dia Medium
32 mm dia Medium
40 mm dia Medium
50 mm dia Medium
65 mm dia Medium
80 mm dia Medium
100 mm dia Medium
125 mm dia Medium
150 mm dia Medium
Providing, supplying ISI mark C.I.D/F. reflux valve (non return valve ) with jointing to pipe work(including all hardware and packing) water works quality with jointing to pipe without bypass arrangement with gunmetal seat excluding c.c. foundation/structural steel supports. For rating PN - 1.6 confirming to IS - 5312: 1984 50 mm dia
65 mm dia
80 mm dia
Lowering, laying and jointing in position following CIDF Reflux valve/ Butterfly valve and Sluice valve including cast of all labour, jointing material including nut bolts and giving satisfactory hydraulic testing etc. complete. 50 mm dia
65 mm dia
80 mm dia
Providing and supplying ISI standard C.I. flanged / S & S specials including all taxes (central and local) railway freight, insurance, unloading from railway wagon, loading into truck, transport to depaRmtental stores/ site unloading stacking etc. complete. D.F.Specials 80 mm to 300 mm dia
Supplying, erecting, testing and commissioning of automatic control panel for three phase , 415 V, A.C. supply, submersible/centrifugal pump set upto 7.5 HP consisting of D.O.L. starter having relay range 9-14 A, S.P.P., combined ammeter/voltmeter, phase indicating lamp enclosed in CRCA powder coated vibration proof enclosure with IP54 protection with single phasing, phase reversal, phase imbalance, etc.
Supplying, erecting, testing and commissioning of automatic control panel for three phase, 415 V, A.C. supply submersible/centrifugal pump set for 7.5 HP to 10 HP consisting of D.O.L. starter having relay range 13-21 A, S.P.P., combined ammeter/voltmeter, phase indicating lamp enclosed in CRCA powder coated vibration proof enclosure with IP54 protection with single phasing, phase reversal, phase imbalance, etc.
Supplying, erecting, testing and commissioning of automatic control panel for three phase, 415 V, A.C. supply submersible/centrifugal pump set upto 7.5 HP- 10 HP consisting of D.O.L. starter having relay range 28-42 A, S.P.P., combined ammeter/voltmeter, phase indicating lamp enclosed in CRCA powder coated vibration proof enclosure with IP54 protection with single phasing, phase reversal, phase imbalance, etc.
Supplying, erecting, testing and commissioning of automatic control panel for single phase, 230 V, A.C. supply submersible/centrifugal pump set upto 3 HP consisting of D.O.L. starter of suitable relay range, S.P.P., combined ammeter/ voltmeter, phase indicating lamp enclosed in CRCA powder coated vibration proof enclosure with IP54 protection.
Supplying, erecting, testing and commissioning of automatic control panel for three phase, 415 V, A.C. supply submersible/centrifugal pump set upto 20 HP consisting of star delta starter having relay range 13-21 A, S.P.P., combined ammeter/ voltmeter, phase indicating lamp enclosed in CRCA powder coated vibration proof enclosure with IP54 protection with single phasing, phase reversal, phase imbalance, etc.
Supplying, erecting, testing and commissioning of automatic control panel for three phase, 415 V, A.C. supply submersible/centrifugal pump set upto 20 HP consisting of star delta starter having relay range 28-42 A, S.P.P., combined ammeter/ voltmeter, phase indicating lamp enclosed in CRCA powder coated vibration proof enclosure with IP54 protection with single phasing, phase reversal, phase imbalance, etc
Supplying, erecting, testing and commissioning of automatic control panel for three phase, 415 V, A.C. supply submersible/centrifugal pump set upto 30 HP consisting of star delta starter having relay range 30-50 A, S.P.P., combined ammeter/ voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP54 protection with single phasing, phase reversal, phase imbalance, etc .
Supplying, erecting, testing and commissioning of soft starters for three phase, 415 V, A.C. supply water pump upto 15 HP consisting ofRS-485 communication port, compact size & range, internal bypass contactor, 400% max. allowed overload of nominal current, with compatibility with teleservice software "remote drive" on internet, having protection for motor overload, phase sequence, excess start time, phase loss, power circuit fault, supply frequency, communication failure etc. complete.
Supplying, erecting, testing and commissioning of soft starters for three phase 415 V, A.C. supply water pump 25 HP consisting of RS-485 communication port, compact size & range, internal bypass contactor, 400% max. allowed overload of nominal current, with compatibility with teleservice software "remote drive" on internet, having protection for motor overload, phase sequence, excess start time, phase loss, power circuit fault, supply frequency, communication failure etc. complete.
Supplying, erecting, testing and commissioning of automatic control panel for three phase, 415 V, submersible/centrifugal pump set upto 10 HP consisting of star delta starter having relay range 9-14 A, S.P.P., combined ammeter/ voltmeter, phase indicating lamp enclosed in CRCA powder coated vibration proof enclosure with IP54 protection with single phasing, phase reversal, phase imbalance, etc.
Supplying, erecting, testing and commissioning of automatic control panel for three phase, 415 V, submersible/centrifugal pump set upto 10- 15 HP consisting of star delta starter having relay range 13-22 A, S.P.P., combined ammeter/ voltmeter, phase indicating lamp enclosed in CRCA powder coated vibration proof enclosure with IP54 protection with single phasing, phase reversal, phase imbalance, etc.
Supplying, erecting, testing and commissioning of float sensor switch for water level controller working on 250 V & rated current 8A, with 2 m wire & high quality of wire & plastic body.
Supplying, erecting, testing and commissioning of directly operated single phasing preventer complete erected and connected to supply to operate in case of single phasing with guarantee for minimum one year.
DOL STARTER- Supplying and erecting DOL starter to operate squirrel cage induction motor working on 380 - 400 V, 3 Ph., 50 Hz., with no volt coil, overload element with necessary material & connected to supply etc. comp. Starter with original sheet steel encloser. Up to 7.5 HP
Up to 10 HP
F.A.S.D. STARTER- Supplying and erecting Fully Automatic Star delta starter to operate squirrel cage induction motor working on 380 - 400 V, 3 Ph., 50 Hz., with no volt coil, overload element and on off push button with necessary material & connected to supply etc. comp. 7.5 HP to 12.5 H.P.
above 12.5 HP to 20 H.P.
above 20 HP to 25 H.P.
above 25 HP to 40 H.P.
Providing structural steel work in single stanctions composed of RSJ chanel etc. with caps, bases, mild steel plates angles, bracket cleats, gusset plates, anchour bolts etc. as per detailed drawing and design or as directed by Engineer-in-charge including cutting, fabricating, hoisting, erecting, fixing, in position making reveted/bolted/welded in connection and one coat of anti corrosive point and over it two coats of oil painting etc. complete.
Earthing for pumping machinery Supplying and erecting earthing with galvanised cast iron earth plate size 60x60x0.6 cm complete with all materials,testing &recording the result as per specification no.EA-EP
Excavation for foundation / pipe trenches in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding back filling, etc. complete. Lift 0-1.5 M.
Excavation for foundation / pipe trenches in Hard murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding back filling, etc. complete. Lift 0-1.5 M.
Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipes suitable for potable water with unplastised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as per IS specification no. 4985 / 1988 including all local and central taxes, transportation, freight charges, inspection charges, loading, unloading, conveyance to the depaRmtental stores/ site and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material i.e. solvent cement, etc.complete (selffit type to be jointed with cement solvent). 63 mm dia. PVC 4 Kg/ cm²
75 mm dia. PVC 4 Kg/ cm²
90 mm dia. PVC 4 Kg/ cm²
110 mm dia. PVC 4 Kg/ cm²
140 mm dia. PVC 4 Kg/ cm²
Lowering, laying and jointing PVC pipes and specials of following class and diameter including cost of conveyance from stores to site of work including cost of all labour, material, except cement solvent, rubber ring, giving satisfactory hydraulic testing as per IS code, etc. complete (with cement solvent joint / ring fit joint). 63 mm dia. PVC 4 Kg/ cm²
75 mm dia. PVC 4 Kg/ cm²
90 mm dia. PVC 4 Kg/ cm²
110 mm dia. PVC 4 Kg/ cm²
140 mm dia. PVC 4 Kg/ cm²
Providing and laying in citu C.C. of of trap / granite/ quartzite/gneiss metal for foundation and bedding including normal dewatering, formwork, compacting and curing, finishing, etc.complete. PCC M -100 For Reinstaining of cement road
Providing and constructing two taps standpost as per type design with excavation 15 cm thick PCC (1:3:6) bedding 20 mm thick PCC (1:2:4) concrete for platform of 1.75 M dia. With side curb and bucket rest 80 mm dia, heavy duty GI pipe central post duly filled therein with C.C. (1:2:4) 5 M long, 20 mm dia. medium G.I. Pipe from point of tapping to standpost additional 20 mm dia G.I. pipe fixed verticaly upto 15 mm dia self closing water taps on brass ferrule etc. complete together with all labour and material charges as per drawing and as directed by Engineer-in-charge when good foundation is available. rate includes draining arrangement by excavating open gutters.
Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete.
Providing,hosting and fixing in position of approved make high density polyethylene UV stabilized conforming to IS 12701 ,water storage tank with necessary connections, testinfg etc complete 9 prior approval of sample by ex. Engineer is necessary before use ) Spect. No. as directed by engineer in charge. for 200 to 1000 lit.
for 1000 to 2000 lit.
Providing fixing 15mm dia screw down bib stop tap of brass including necessory socket union nut complete (PWD CSR 22-23 P.NO. 288 I.NO. 41.40
Providing fixing 20 mm dia screw down bib stop tap of brass including necessory socket union nut complete (PWD CSR 22-23 P.NO. 288 I.NO. 41.41
Providing fixing 25mm dia screw down bib stop tap of brass including necessory socket union nut complete (PWD CSR 22-23 P.NO. 288 I.NO. 41.42
Providing and fixing screwdown 15mmdia. wheeled stop tap of brass including necessary sockets/union nut complete
Providing and fixing screwdown 20mmdia. wheeled stop tap of brass including necessary sockets/union nut complete
Providing and fixing screwdown 25mmdia. wheeled stop tap of brass including necessary sockets/union nut complete
Providing and fixing screw down for 32 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete.
Providing and fixing screw down for 40 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete.
Providing and fixing screw down for 50 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete.
Providing and fixing screw down for 50 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete.
Providing and laying in trenches dia CPVC PIPE including necessary excavation fitting reffilling trenches etc complete including removing existing pipe line if the same in pwd chewky or as directed etc complete for 15 mm dia
for 20 mm dia
for 25 mm dia
for 32 mm dia
for 40 mm dia
for 50 mm dia
For ABove Submersible Pump 30.HP Providing, erecting and giving test of 150 mm dia. submersible pump sets confirming to IS 8034 and motor confirming IS 9283. Pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and Motor suitable for working on 415 V± 10%, 3Ph, 50 Hz., A.C. supply, Cable guard, thrust carbon/fibre bearing to accept entire hydraulic thrust, water proof winding shall be provided. The pump set shall be suitable for direct coupling. Pump shall have suitable suction stainer shall also be provided. 3 core, single/double run copper conductor submersible type flat cable 3 Mtr. and 3 pairs of erection clamps. Rates per pump upto 8 stages (as per design) FOR 75 HP
FOR 75HP supply rate should be increased per stage for pump with more than 8 Stage
Submersible Pump 150 mm dia (with Bronze / Stainless steel (CF8M) Impeller) up to 8 stages 1.50 HP
Submersible Pump 150 mm dia (with Bronze / Stainless steel (CF8M) Impeller) up to 8 stages 2.0 HP
Submersible Pump 150 mm dia (with Bronze / Stainless steel (CF8M) Impeller) up to 8 stages 3.0 HP
Submersible Pump 150 mm dia (with Bronze / Stainless steel (CF8M) Impeller) up to 8 stages 4.0 HP
Submersible Pump 150 mm dia (with Bronze / Stainless steel (CF8M) Impeller) up to 8 stages 5.0 HP
Submersible Pump 150 mm dia (with Bronze / Stainless steel (CF8M) Impeller) up to 8 stages 6.0 HP
Submersible Pump 150 mm dia (with Bronze / Stainless steel (CF8M) Impeller) up to 8 stages 7.5HP
Design Supplying, installing, testing and commissioning of Hybrid Controller for 3 to 100Hp solar Pumping System Compatible to cloudbase (RMS) Dashboard reporting/monitoring and Management monitoring system with FIve Years C.M.C. as per GSDA Circular Dtd. 11/09/2024 5.0 Hp to 7.50 HP
Design Supplying, installing, testing and commissioning of Hybrid Controller for 3 to 100Hp solar Pumping System Compatible to cloudbase (RMS) Dashboard reporting/monitoring and Management monitoring system with FIve Years C.M.C. as per GSDA Circular Dtd. 11/09/2024 7.5 Hp to 10.0 HP
Design Supplying, installing, testing and commissioning of Hybrid Controller for 3 to 100Hp solar Pumping System Compatible to cloudbase (RMS) Dashboard reporting/monitoring and Management monitoring system with FIve Years C.M.C. as per GSDA Circular Dtd. 11/09/2024 Above 10 hp to 15 HP
Design Supplying, installing, testing and commissioning of Hybrid Controller for 3 to 100Hp solar Pumping System Compatible to cloudbase (RMS) Dashboard reporting/monitoring and Management monitoring system with FIve Years C.M.C. as per GSDA Circular Dtd. 11/09/2024 Above 15 HP to 20 HP
Design Supplying, installing, testing and commissioning of Hybrid Controller for 3 to 100Hp solar Pumping System Compatible to cloudbase (RMS) Dashboard reporting/monitoring and Management monitoring system with FIve Years C.M.C. as per GSDA Circular Dtd. 11/09/2024 Above 20 hp To 25 HP
Design Supplying, installing, testing and commissioning of Hybrid Controller for 3 to 100Hp solar Pumping System Compatible to cloudbase (RMS) Dashboard reporting/monitoring and Management monitoring system with FIve Years C.M.C. as per GSDA Circular Dtd. 11/09/2024 Above 25 hp To 35 HP
Design Supplying, installing, testing and commissioning of Hybrid Controller for 3 to 100Hp solar Pumping System Compatible to cloudbase (RMS) Dashboard reporting/monitoring and Management monitoring system with FIve Years C.M.C. as per GSDA Circular Dtd. 11/09/2024 Above 35 hp To 50 HP
Design Supplying, installing, testing and commissioning of Hybrid Controller for 3 to 100Hp solar Pumping System Compatible to cloudbase (RMS) Dashboard reporting/monitoring and Management monitoring system with FIve Years C.M.C. as per GSDA Circular Dtd. 11/09/2024 Above 50 hp To 75 HP
Design Supplying, installing, testing and commissioning of Hybrid Controller for 3 to 100Hp solar Pumping System Compatible to cloudbase (RMS) Dashboard reporting/monitoring and Management monitoring system with FIve Years C.M.C. as per GSDA Circular Dtd. 11/09/2024 Above 75 hp To 100 HP
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.14 MB
BOQ_2197584.xls
BOQ • 0.79 MB
GSDA6NIT140Details.pdf
Tender Documents • 0.57 MB
Download all tender documents and submit your bid