Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹23.7 LAccepted-AOC A 93 SECTOR 36 GREATER NOIDA GAUTAM BUDDHA NAGAR UTTAR PRADESH 201308 | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201308 | ₹23.7 L Quoted ₹24.4 L | 1 | Accepted-AOC L1 bidder |
| 2 | 2₹27.7 L+₹3.3 L (13.7%)Rejected-Finance G 58 KIRAN GARDEN UTTAM NAGAR NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | ₹27.7 L+₹3.3 L (13.7%) | 2 | Rejected-Finance 2nd |
| 3 | 3₹28.8 L+₹4.5 L (18.3%)Rejected-Finance WZ 88A JANAK PARK HARI NAGAR NEW DELHI 110064 | NEW DELHI | NEW DELHI | DELHI | 110064 | ₹28.8 L+₹4.5 L (18.3%) | 3 | Rejected-Finance 3rd |
| 4 | Rejected-Technical 1 OPP NAGAR NIGAM KATNI MAIN ROAD KATNI MADHYA PRADESH 483501 | KATNI | MADHYA PRADESH | 483501 | - | - | Rejected-Technical Not admitted due to not enlisted in category c(vi) |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
1 Jul 2024, 6:00 pmClosed
GE AF Tughlakabad
GE AF TUGHLAKABAD SANGAM VIHAR PO NEW DELHI 110080
REPAIR/MAINT OF FIRE EQUIPMENT, FIRE ALARM, FIRE PANEL, SMOKE DETECTOR, FIRE HYDRANTS AND FIRE PIPE LINE AND CONNECTED WORK AT TECH AREA UNDER GE (AF) TUGHLAKABAD
2024_MES_652636_1
GE/TKD-20/2024-25
Open Tender
Civil Works - Others
Item Rate
270 days
GE AF Tughlakabad
MES contractor enlisted having deposited Standing Security with dept. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category
9 documents required · 9 mandatory
₹500
GE AF Tughlakabad
₹60,000
Yes
9 Nov 2024
3 Jun 2024
3 Jul 2024
3 Jun 2024
1 Jul 2024
18 Jun 2024
Amount
S&F in replacement and installation and testing of single loop analogue addresssable Fire control panel of make Hochiki cat No: HFP AP-AS certified to EN54-2/EN54-4 having following features: A) Panel Physical features: Single loop, Compact & stylish enclosure, removable equipment chasis, supporting hochiki ESP loop drivers, which are all capable of providing upto 400 milliamps of loop current, integral 3 programmable relays, 3A power supply & temperature compensated battery charger provides ample power for the two 1 Amp rated standard sounder outputs & loop powered sounder & other devices. B) Connectivity: HFP AP-AS should connect seamlessly to other HFP AS or HFP multi loop panels and repeaters via the fully fault tolerant and robust HFP network card. The HFP AP-AS support all HFP serial bus peripherals such as HFP AP-CRL repeaters, 16 channel I/O boards, realy boards, sounder boards & conventional zone board to provide an additional 512, fully programmable points, 16 zonal LED indicators are provided as standard and panel will support upto 500 network wide software zone as per HFP multi loop panels.
C) Software: Panel should include 2 programmable inputs, 5 programmable inputs, , large graphic display, real time clock, sensitivity adjustment and drift compensation, networked with HFP control panel and existing system, compatible with HFP & HFP AP-CRL repeaters, stores 500 last events in event log, dial up modem connection. Make: Hochiki cat No: HFP AP-AS or equivalent make (compatible with existing sytem & network) Note: 1) Integration & programming from OEM of new panel with addressable detectors & old network is deemed to be included in quoted rates. 2) Cost of software & its installation, T&P, tradsmen or any security clearance required at site will be arranged by contactor. Cost of same is deemed to be included in quoted rates. 3) Installation of New sealed maintenance free batteries 12V, 7/7.2 Ah suitable for FACP panel as per panel requirement is deemed to be included in quoted rates.
S&F in replacement and installation and testing of analogue addressable fire control panel repeater of make: Hochiki having full display & optional control from a small and unobtrusive local control station, full colour graphical display with touch screen functionality, delivers information on the status of the fire alarm system to single or multiple locations, for other annunciation and control applications panel should be configured to provide customisableswitches and indications for a host of fire system ancillary functions, panel be connected to the fire control panels fault tolerant, ancillary RS485 bus or to the fire alarm panel fault tolerant network. Panel should have following features: 1) Robust full colour 7" 800x480 touch screen graphical display. 2) Full indication of all information displayed at the fire control panel 3) Automatic display brightness adjustment 4) Silenceable internal sounder 5) Connections Via: Control panel RS485 bus or option to connect to control panel network 6) Low current, 24V DC powered 7) Configurable functionality, Configurable languages & optional enable keyswitch.
Make: Hochiki Model: latitude or equivalent make (compatible with existing sytem & network) Note: 1) Integration & programming from OEM of new panel with addressable detectors & old network is deemed to be included in quoted rates. 2) Cost of software & its installation, T&P, tradsmen or any security clearance required at site will be arranged by contactor. Cost of same is deemed to be included in quoted rates. 3) Installation of New sealed maintenance free batteries 12V, 7/7.2 Ah suitable for FACP panel as per panel requirement is deemed to be included in quoted rates.
S&F in replacement and installation and testing of analogue addressable smoke sensor having removable high performace chamber with Twin Fire LED's allow 360 degree vewing lock mechanism (sensor to base), variable sensitivity, electronically addressed, approved by LPCB, EN 54 approved, complete all as specified and as directed by Engr-in-Charge. Make: Hochiki or equivalent make (compatible with existing sytem & network)
S&F in replacement and installation and testing of analogue addressable manual call points ESP analogue addressable protocol having status LED for alarming and standby mode, electronically addressed., approved by LPCB, EN-54 approved, complete all as specified and as directed by Engr-in-Charge Make: Hochiki or equivalent make (compatible with existing sytem & network)
S&F in replacement and installation and testing of analogue addressable Beam Master detector with Transmitter and receiver (Add power supply units & Module), of make: hochiki, compitble with the existing hochiki system, complete all as specified & directed. Note: 1) Integration & programming from OEM of beam detector compitible with old network is deemed to be included in quoted rates. 2) Cost of software & its installation, T&P, tradsmen or any security clearance required at site will be arranged by contactor. Cost of same is deemed to be included in quoted rates.
Supply, fixing and testing in replacement of analogue addressable dual input module which allows 2 independently controlled change over relays, relays operated at 30 V DC at 1 Amps having auxiliary monitored input, followed by ESP analogue addressable protocol, electronically addressed, approved, by LPCB, EN-54 approved complete all as specified and as directed by Engr-in-Charge Make: Hochiki or equivalent make (compatible with existing sytem & network)
Supply, fixing and testing in replacement of analogue addressable dual relay controller which allows 2 independently controlled change over relays, relays operated at 30V DC at 1 Amps having auxiliary monitored input, followed by ESP analogue addressable protocol, electronically addressed, approved, by LPCB. EN-54 approved complete all as specified and as directed by Engr-in-Charge Make: Hochiki or equivalent make (compatible with existing sytem & network)
M&L for disconnecting of unserviceable analogue addressable Fire alarm panel from site of make: hochiki, transporting to and getting it repaired from a authorised service center, reinstallation & testing of panel. Servicing/repair include change of network card, power card, display of any type, charging card, SMPS, upgradation/re-installation of software mini-transformer coil of any size & capacity, mother board & IC's from authorised service center or any other minor parts as required to make panel serviceable, complete all as specified & directed.
Supply, installation, testing and commissioning in replacement of microprocessor based 4 Zone conventional fire alarm control panel robustly designed and easy to operate, fully compliant with and tested to BS EN 54-2 and BS EN 54-4, Compatible for use on BS5839, Part 1, 2002 installation, 2 wire repeaters and ancillary boards, fully programmable using simple menu options, simple, single board construciton, installer friendly, compatible with Hochiki, conventional range of devices, two monitored sounder outputs, 3 Amp power supply, auxiliary power output, The control must be EN 54 approved, complete all as specified and as directed by Engr-in-Charge Make : Ceasefire/ LTS/ Agni
Supply, installation, testing and commissioning of microprocessor based 2 Zone conventional fire alarm control panel robustly designed and easy to operate, fully complaint with and tested to BS EN 54-2 and BS EN 54-4, Compatible for use on BS5839, Part 1, 2002 installation, 2 wire repeaters and ancillary boards, fully programmable using simple menu options, simple single board construciton, installer friendly, compatible with Hochiki, conventional range of devices, two monitored sounder outputs, 3 Amp power supply, auxiliary power output, The control must be EN 54 approved, complete all as specified and as directed by Engr-in-Charge Make : Ceasefire/ LTS/ Agni
Supply, installation, testing and commissioning in replacement of (multi criteria) type detector with combination of both heat and smoke detection arrangement of the same make as of fire alarm control panel. Detector should have a third terminal to provide an integral remote indicator output, removable high performance chamber, remote indicator output, wide voltage range (9.5 to 30V d.c) low profile design with one piece outer cover, twin fire LED's allow 360 degree viewing, range of mounting bases, approved by LPCB complete all as specified and as directed by Engr-in-Charge Make : Ceasefire/ LTS/ Agni
Supply, installation , testing and commissioning in replacement of conventional manual call point of the same make as ot fire control panel, based upon the industry standard KAC world series housing and features easy to install, push fit wiring terminals.The unit can support either a Frangible glass element or a 'Non frangible plastic' element. Approved to EN54-11 : 2001 Terminals can accommodate upto a 2.5mm solid conductor. approved by LPCB. complete all as specified and as directed by Engr-in-Charge Make : Ceasefire/ LTS/ Agni
M&L in replacement for laying on wall/roof/floor/ground of fire survival copper cable 1.5 Sqmm 3 cores, stranded (class-2) non compacted circular annelaed plain copper conductor, glass mica tape over conductor, XLPE insulated, cores laid up, extruded FRLS-ZH inner sheathed, glavanised steel round wire, extruded FRLS-ZH outer sheathed, 1100V grade confirming to circuit integrity test @ 950 degree celsius for 3 hrs, complete all as specified & directed. Note: 1) Steel clip & saddle, screw etc. along with copper thimble (both pin type & nut bolt type) at each end & as per site is deemed to be included in quoted rate. T&P required for saddling/ cliping on wall is deemed to be included in quoted rates. 2) Rates are inclusive of making holes of suitable size with drill machine in concrete/brick/stone wall of any thickness to pass cable from one section to other of building.
Supply & fixing in replacement of sealed maintenance free (SMF) lead acid batteries 12V, 7/7.2 Ah suitable for FACP panel complete all as specified and as directed by Engr-in-Charge
Supply & fixing in replacement of PCB suitable for FACP circuit incl wiring kit of existing capacity complete all as specified and as directed by Engr-in-Charge
Labour only tracing out the fault and functiong the microprocessor based upto 8 Zone conventional/ addressable fire alarm control system, reassembling and testing from a authorised person/ fire expert, complete all as specified and directed. Note :- (i) The fault shall be carry out by highly skilled trades man only and charges for new items are not deemed to be included under this item. (ii) The contractor has to provide necessary T&P & manpower to skilled trades men for detection of fault in beam detector & smoke detector upto a height of 12-14 mtrs height hangers/bldg.
Testing & Maintenance/repair of fire alarm system & fire hydrant system per month at various location in 7 BRD as required viz, fire panel, smoke detecter, beam detecter, wall sounder, all cable connection, manual call bell point and replacement of unserviceable parts with new parts re-assembling, connecting, commissioning and testing complete all as specified and directed by Engr-in-charge. Note:- (i) New parts if any required shall be measured and paid separately.
Supply & fix in replacement of SS fire hydrant landing valve type B ( double head outlet) of 63 mm dia conforming to IS 13039-1991 along with 2 nos cast iron hand wheel , 2 nos female Instantaneous outlet, 2 nos ABS blank cap and chain, complete all as specified and directed. Make: Padmini/DSS/Newage/kartar/life gaurd.
Supply & fix in replacement of SS fire hydrant landing valve type B ( single head outlet) of 63 mm dia conforming to IS 13039-1991 along with 1 nos cost iron hand wheel , 1 nos female Instantaneous outlet, 1 nos ABS blank cap and chain, complete all as specified and directed. Make: Padmini/DSS/Newage/kartar/life gaurd.
Supply and fix in replacement hose box wall mounting type for keeping 2 Nos hose pipe of length 15 meter each, branch pipe.nozzle, coupling etc made out of 16 gauge mild steel sheet size 800mm x 600mm x 250mm , acrylic fronted double door with lock , 2 keys and a break glass recess for Key, painted fire red, complete all as specified and directed. Make: Padmini/DSS/Newage/kartar/life gaurd.
Supply and fix in replacement fire hose pipe shut off SS nozzle suitable for 20/25mm hose pipe, having 6mm dia outlet dia, made threaded outlet, conforming to IS 903, complete all as specified and directed. Make: Padmini/DSS/Newage/kartar/life gaurd.
Supply and fix in replacement of SS branch pipe 63mm instantaneous inlet, made threaded outlet, 15/20mm bore nozzle long conforming to IS 903, complete all as specified and directed. Make: Padmini/DSS/Newage/kartar/life gaurd.
Supply and fix in replacement of reinforced rubber lined (RRL) fire hose type-II, ISI marked 63 mm dia 15 meter long conforming to IS 636 complete with SS male and SS female coupling conforming to IS 903, complete all as specified and directed. Make: Padmini/DSS/Newage/kartar/life gaurd.
S&F in replacement of thermoplastic fire hose pipe 30mtr long, 20mm dia, ISI marked, Type-II (W.P. - 10Kgf/cm sq) confirming to IS:12585, complete all as specified & directed.
Supply and fix in replacement Manual Swing type fire hose reel ISI marked IS: 884 with Thermoplastic hose pipe 30mtr. Long, dia 20mm, ISI marked IS: 12585 with GM shut off nozzle complete in all respect Type II (W.P. 10.2 Kgf/cm2) including fixing assembly on wall with fastner of suitable size and connection of water pipe line & taking out old u/s one frome site, Complete all as specified and as directed by Engr-in-charge. Make: Padmini/DSS/Newage/kartar/life gaurd/ Life gaurd/ Kartar
Taking out heavy duty MS/concrete duct cover 1.2x0.7x0.08mtr weighing 250 kg for cleaning of mud/stone whichever is their and refixing the duct cover after taking out pipe line and refixing the same of any size and capacity in the duct complete all as specified and as directed by Engr-in-charge
M&L for boring holes 2 mtr deep (trench less) in soil for under-reamed piles, 250mm dia pipe, getting out and disposal of spoil to a distance of not exceeding 50 mtr and making good distrubed surface all as specified and as directed by Engr-in-Charge.
M&L for dismantlling joints of flanged pipes in position including removing old gasket, nut ,bolts etc upto size 150mm dia complete all as specified and directed by Engr-in-Charge.
M&L for joints of flanged pipes in position including new rubber or fiber board gasket, nut ,bolts washers etc upto size 150mm dia complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Lead wool joint for CI pipe of 150mm dia including spurn yarn of suitable size, complete all as specified & directed.
All as above item No: 33, but for 100/80mm dia including spurn yarn of suitable size, complete all as specified & directed.
Taking up U/S CI/DI water main(incl all fitting) with flanged ends incl disconnecting pipes and fittings complete of size upto 150 mm bore for laying /rerouting of serviceable pipe after cleaning complete all as specified and directed.
Material and labour In replacement of CI/DI pipes of size 150 mm bore with flanged ends centrifugally cast class A in any length laid in trenches/on surface/ over masonary pillar and connection to old or new position complete all as directed. Make- Jindal/ kesoram/electro steel. Note: CI fitting /gasket joint will be measured and paid seperately all the dismanted / demolished /taking down materyal shall be removed from site.
Material and labour In replacement of CI/DI pipes of size 100 mm bore with flanged ends centrifugally cast class A in any length laid in trenches/on surface/ over masonary pillar and connection to old or new position complete all as directed. Make- Jindal/ kesoram/electro steel. Note: CI fitting /gasket joint will be measured and paid seperately all the dismanted / demolished /taking down materyal shall be removed from site.
M&L in replacement CI/DI special like bend any type radius and angle tapers any type straght bend increacing decreacing single or double branch etc) tee pipe single branch y juction double branch cross(all end flanged of the following size upto 150 mm dia complete all as specified and directed. Note: Gasket, nut bolt & washers for fitting shall be measured and paid separately.
Suply and fixing in replacement cast iron NRV flanged end of size 150 mm dia with all fitting and accessories including taking down old unserviceable NRV complete all as specified and directed by Engr-in-charge. Make:Zoloto or equivalent in Kirloskar/Kartar/Bir
S&F in replacement of CI/Gunmetal NRV 50mm dia PN 1.6 with rubber seat, complete all as specified & directed. Make: Kartar/ leader/Bir/ Zoloto
S&F in replacement of CI/Gunmetal NRV 65mm dia, PN 1.6 with rubber seat, complete all as specified & directed. Make: Kartar/ leader/Bir/ Zoloto
S&F in replacement of CI Y stainer flanged end 65mm dia, complete all as specified & directed. Make: Kartar/ leader/Bir/ Zoloto
S&F in repair Cast iron foot valve of size 150mm dia heavy duty with necessary fixing arrangement like nut , bolts washer packing sheet etc including taking out existing unserviceable foot valve complete all as specified and directed.
S&F in replacement of CI Foot valve 50mm dia threaded ends type operation with heavy duty rubber seat as per IS:4038 along with accessories, complete all as specified and directed.
S&F in replacement of CI Foot valve 65mm dia threaded ends swing type operation with heavy duty rubber seat as per IS:4038 along with accessories, complete all as specified and directed.
Supply & Fix in replacement Cast Iron sluice valve of size 80 mm bore class PN-1.6 IS : 14846 with SS spindle, both ends flanged with holes, provision of nuts, bolts, washers, rubber gasket etc. with CI wheel, fixed to CI water mains , and including taking down old unsv Sluice valve complete all as specified and directed by Engr-in-charge. Make:Zoloto/ kartar/ Kirloskar/ Leader/ Bir
All as per item above but 100 mm dia bore, complete all as specified and directed. Make:Zoloto/ kartar/ Kirloskar/ Leader/ Bir
All as per item above but 150 mm dia bore, complete all as specified and directed. Make:Zoloto/ kartar/ Kirloskar/ Leader/ Bir
Opening of fire Jokey Pump type 30 LPS for repair and replacement of following u/s parts including re-fixing of all the same and testing and commissioning complete all as directed. (a) Replacement of gun metal impeller. -01 Nos (b)Replacement of gun metal bush -02 Nos (c) Replacement of ball bearing.Make: SKF - 02 Nos. (d) Replacement of oil seal -01 Nos. (e) Replacement of gland -01 Job
M&L for rewinding of burnt Jokey pump motor of capacity upto 30HP, 30 LPS, 3 phase ,415 V, 50 Hz of any make with copper conductor of the same specification as per old one after dismantling / cutting out burnt windings from stator assembly, cleaning slots properly complete with insulating slots packing, sleeves, papers & reassembling stator and rotor after replacement of worn out spares/matching works including painting with two coats of synthetic enamel paint over a coat of red oxide primer after preparation of motor external surface and water proof jointing for cable 3 core, with replacement of oil seal, sand guard, bolt gasket, cable packing ring, circlip, bearing bush upper & lower etc complete all as specified and as directed.
M&L in replacement for panel inbuilt change over switch 160A, 4 pole, open execution, Phase Barriers & Handle with door interlock kit is integral part of the Changeover Switch, complete all as specified and directed by Engr-in-charge. make- Havell's Cat No: IHCNFO0160/ Legrand/seimens / L&T/ Standard.
M&L in replacement for MCCB 4 pole 160 amps, 36 KA Breaking capacity, with fixed thermal magnetic release, along with spreader of suitable rating, size & length, complete all as specified and directed by Engr-in-charge. Make- Legrand/Havell's / L&T/Standard.
All as above item No: 52, but MCCB 3 pole 160 amps,36 KA, complete all as specified and directed by Engr-in-charge. Make- Legrand/ Havells/ L&T/ Siemens
All as above item No: 52, but MCCB 3 pole 100 amps,36 KA, complete all as specified and directed by Engr-in-charge. Make- Legrand/ Havells/ L&T/ Siemens
All as above item No: 52, but MCCB 3 pole 63 amps,36 KA, complete all as specified and directed by Engr-in-charge. Make- Legrand/ Havells/ L&T/ Siemens
S&F in replacement of HRFR PVC Insulated copper conductor, (Unsheathed) Flexible Cables 25sqmm single core, 1100 Volt Conforming to IS 694, complete all as specified and directed. Note: copper thimble of suitable size & any qty as required on site is deemed to be included in quoted rates.
All as above item No: 56, but for 10sqmm copper wire, complete all as specified and directed.
M&L in replacement of LED indicator lamp, complete all as specified and directed. Make- SG/L&T/Selzer
M&L in replacement of panel mounted ON/OFF push button with contact block, complete all as specified and directed
M&L in replacement of CT 50/5 complete all as directed. Make-AE/kappa/Legrand
Supply & fix in replacement of Electronic timer 415 Volt, 50 Hz range 3-30 Secs complete all as specified and directed by Engr-in-charge. Make- L&T Cat No: ST80329OOOO/ Havells/Siemens
M&L in replacement of Single phase preventor VSP 2 auto/manual reset, 40Volt unbalance suitable for motor starter of any size , 415V complete all as specified & directed. Make-AE/L&T/SG/Minilec.
Supply & fix in replacement of contactor MNX18 with 1NC/1NO , AC Rating 30Amp suitable for direct mounting, complete all as specified and directed. Make- L&T or equivalent ISI marked.
Supply & fix in replacement of contactor MNX70, AC Rating 100Amp suitable for direct mounting, complete all as specified and directed. Make- L&T or equivalent ISI marked.
S&F in replacement of Add-on block with 1NO/1NC, 415V, complete all as specified & directed.
S&F in replacement of Add-on block with 2NO+2NC, 415V, complete all as specified & directed.
M&L in replacement of Thermal overload relay (Manual reset) relay range 9-16 amp suitable for direct mounting, complete all as specified and directed. Make- L&T / Havells/ seimen/ legrand
M&L in replacement of Thermal overload relay (Manual reset) relay range 45-75 amp suitable for direct mounting, complete all as specified and directed. Make- L&T / Havells/ seimen/ legrand
S&F in replacement sheet metal enclosed Three phase Direct on line starter of capacity 5 HP overload relay range 9-14 Amp.Make- L&T /Havell's/ Seimens/ Schineder
S&F in replacement Nut, bolt, washer of different size ISI marked, complete all as specified and directed.
S&F in replacement lather gasket ISI marked, complete all as specified and directed.
Supply in repair of grease for pump servicing and filling of gland dori in pump ISI marked, complete all as specified and directed.
M&L for Removal of the existing paint from the pumping set & LT panel of any size by the hand scrapping and painting gray colour for the motor, Blue colour for pumps and black colour for the pump base & grey for LT panel with two coat of synthetic enamel paint and rewriting the SM NO. All as specified and directed by Engr-in- charge.
M&L for Removal of the existing paint from the suction and discharge pipe line upto 200mm dia by the hand scrapping and painting black colour for the suction line and discharge line with two coat of synthetic enamel paint, all as specified and directed by Engr-in- charge.
M&L for minor reparing / rectified and attending the complaint of pressurized fire pipe line leakage, motor pump set stater, Fire hydrant leakage, electrical defects or any other plumbing defect and reparing of any size by highly skilled trades man and making functional including all GI fittings like elbow, socket, Tee, Nipple, bend, union etc and making new threads as required at site including excavation,return refilling and removing soil & earth work etc. complete all as specified and directed.
M&L for Cement concrete in foundations, filling and mass concrete of Type C2 (1:3:6), (40 mm graded aggregate) for 5000Ltrs HDPE tank foundation, motor foundation etc.
Supply and fixing in repair of pre-fabricated MS structural steel (IS marked) work consisting of channels / angles /flats/ round bars/MS pipe & other sections etc of various sizes and shape, cut / weld / drilled holes etc hot / cold in position for cross arms with FI clamps (full, half D and earth clamp etc) incl necessary MS bolts, nuts etc and painting for hanging strcture for repair bay all as directed by Engr in Charge.
S&F in replacement of pre-painted galvatume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering/clading to wall, fixed with self tapping screws and bending of sheet as required and as directed by Engineer-in-Charge.
M&L in replacement of pressure gauge to read in IS/BS unit type KG/cm2 and LB/inc2 reading marked 0-2, 0-30 respectively including taking old one complete all as specified and as directed.
Material and labour in replacement of earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to GI strip 25×4mm mm main earthing lead by means of galvanized bolts, nuts and washers all as shown in electrical plate no 5 of MES Schedule Part-I (1991) with connected to earth test point & to main switch board etc with & including adequate quantity of charcoal dust and common salt all around earth plate, PCC (1:3:6) type C-1 (using 40mm graded stone aggregate), angle iron frame for cover, pre cast RCC (1:2:4) type B-1 (using 20mm graded stone aggregate) with 12mm dia round bar handle, GI medium grade watering pipe 20 mm dia with funnel and wire mesh, and 40 mm dia GI medium grade earth lead protection pipe, complete all as specified and directed. NOTE : Earth strip and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item and additional earth strip/protection pipe etc. if any required at site shall be measured and paid for separately under appropriate item of Schedule `A’
All as above item No: 83, but for galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel, complete all as specified & directed.
S&F in replacement of Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire, complete all as specified and directed.
All as above item No: 85, but 25x4mm galvanised iron strip, complete all as specified & directed.
Disconnecting, taking out, removing old existing unserviceable underground and Supplying ,Laying, jointing and testing new XLPE insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed of size 3.5 core 35 sqmm. Note: aluminium thimbles any qty required at site is deemed to be included in quoted rates. Make :- Havells/Polycab/Gloster/Finolex.
All as above item No: 87, but for 3.5 core, 95 Sqmm, complete all as specified & directed.
M&L for heat shrinkable 1.1KV XLPE cable staright through joint, complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 sqmm to 150sqmm, complete all as specified & directed.
M&L for heat shrinkable 1.1KV XLPE cable outdoor termination, complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 sqmm to 150sqmm, complete all as specified & directed.
Excavation in trenches not exceeting 1.5 Mtr wide and not Exceding 1.5 Mtr in depth and getting out in Hard/Dense soil for laying cables all as directed.
Returning, filling in including spreading, levelling, watering and ramming in layers not exc. 25 cms, complete all as specified and directed.
Removing excavated material not exceeding 50 Mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Supply and fill dry river sand in trenches for cable cushioning, complete all as specified and directed.
Supply and fix bricks subclass B designation 75 complete all as specified and directed.
M&L in replacement of construction of valve chambers with MS cover 3 mm thick of valve pit of size 1200x1200x1200 MM( internal dimensions) including necessary excavation, earth work 150 mm thick PCC 1:4:8 Type D2 as in foundation, PCC 1:2:4 Type B1 in coping plastering 15 mm thick in cm 1:4, and angle iron frame 50x50x06 mm and locking arrangement including painting with coat of synthetic enameled paint over a coat of redoxide primer after preparation of surface complete all as specified and directed by Engineer-in-charge.
Taking out existing U/S GI pipe line of size upto 80 mm bore, complete all as specified and directed.
S&F in replacement of galvanised steel water tubing medium grade in trenches / wall /floor with all fittings of following size , complete all as directed by Engr-in-charge.
20 mm bore GI pipe
25 mm bore GI pipe
40mm bore GI pipe
50mm bore GI pipe
80 mm bore GI pipe
S&F in replacement Ball valve brass with iron handle screwed both ends for iron pipe and fixed of following sizes :- Make-Zoloto, Leader, Castle
Dia of pipe 15mm
Dia of pipe 20mm
Dia of pipe 25mm
Dia of pipe 50mm
Disconnecting the water mains from the suction and delivery pipe line of Monoblock/centrifugal pump sets/open well pump set of any description and in any position and taking out pump set / motor from the base frame including disconnecting electric connections and foundation, nuts and bolts. for servicing /overhauling, cleaning, oiling/greasing, fixing of serviceable parts in position, removing & replacement of defective / unserviceable parts with new parts and reassembling the pump and motor of capacity 5 HP capacity, ensuring proper alignment of pump and motor, fixing in position, connecting to existing system and testing at site on full load to the entire satisfaction of the Engineer-in-Charge. Note: - (i) The replacement of defective / unserviceable parts shall be measured and paid separately as “Supply only” under appropriate item of Sch ‘A’ and fixing rate for new items are deemed to include under these item. (ii) The rates for above items are deemed to include transportation of pumps/ motors to and from workshop as approved by Engineer-in-charge for necessary repairs, alignment and testing of pump and motors at workshop.
Rewinding of 5 HP motor same gauge with super enamelled copper wire including removing burnt winding cleaning of slotes sepration of rotor and startor making insulation to all joint . and replacement of the following items.All as specified and directed by Engr-in- charge. (a) Replacement of ball bearing.Make: SKF-01 Nos (b) Replacement of cooling fan - 01 Nos. (c) Replacement of capacitor of suitable mfd (d) Replacement of seal, bush (e) Repair/replacement of shaft Note: The rate quoted by the contractor shall be deemed to include the cost of transportation from site to authorised workshop and back, fixing / lowering in position
S&F in replacement of nitrile lining Butterfly valve of 50mm dia with MS handle, complete all as specified and directed.
S&F in replacement of PVC insulated Copper cable of 2.5Sqmm 3 core, complete all as specified & directed.
Material & Labour for Wiring with Copper conductor cables in PVC casing & caping with single core PVC insulated and unsheathed 1100 volts grade cable with multistranded copper conductor of size 1.5 Sqmm nominal area drawn through & including PVC casing & caping (circular/flat pvc conduit), medium duty not less than 20 mm dia on wall/fixed on wall/ceiling with GI saddles , GI screws , rawl plugs with all fittings including tees , junction boxes including fixing GI gang box of any module not less than 3.15mm thickness flushed in wall with hylem cover sheet of suitable size for mounting switches , sockets & regulators & drawing through continuous earth wire of PVC insulated unsheathed 1100 volts grade cable with copper conductor solid conductor of size 1.5 sqmm, for 3 pin socket outlet 5Amps independent with cable 1.5 Sqmm size, complete all as specified & directed by Engineer -In-Charge.
Supply and Fixing in replacement of modular switches 1 way, 6 Amp 1 module complete all as specified & directed by Engineer - In-Charge.
Supply and Fixing in replacement of modular Socket, 6A - 2/3 pin combined 2 module, complete all as specified & directed by EIC.
Supply and fix in replacement of factory made epoxy polyster powder coated double door distribution board SP&N 4 way fabricated from minimum 1.6 mm thick CRCA sheet with double door (IP-43 protection) fixed flush to wall and standard DIN rail, earth bar and cable ties for cable management, suitable for one incoming and 6 outgoings complete all as specified and confirming to IS: 8623. Note: Cutting on wall and taking out old one and then flushing new DB and making all the connection as before and any accessories required to fix the DB including making good the disturbed surface is deemed to be included in quoted rate.
S&F in replacement of SPN MCB, 32Amp , B Curve, 10 KA , complete all as specified & directed.
S&F in replacement of SP MCB, 6-20Amp , B Curve, 10 KA , complete all as specified & directed.
S&F in replacement of TP MCB, 63Amp , C Curve, 10 KA , complete all as specified & directed.
S&F in replacement of Wiring for circuit/submain wiring alongwith earth wire in PVC conduit pipe with wire of 2x4.0 sq. mm + 1x2.5 sq. mm earth wire of FR is PVC insulated copper conductor, single core cable in surface/recessed as required, complete all as specified & directed.
S&F in replacement of polycarbonate 3 pin plug top, 5Amp, 215V, ISI marked, complete all as specified & directed.
M&L for cleaning of SWT upto 3000Gln, complete using suitbale no of labour & dewatering of complete water with pump set, complete all as specified & directed.
Sumit Enterprises (BID ID -3043878)
SANWARIYA ENTERPRISES (BID ID -3038736)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .