Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.8 LAccepted-AOC KALIAPPA COMPLEX THRICHY ROAD RANGANATHAPURAM SULUR COIMBATORE 641 402 | COIMBATORE | COIMBATORE | TAMIL NADU | 641402 | L1 | Accepted-AOC AWARD OF CONTRACT | |
| 2 | L2₹50.0 L+₹34,214 (0.69%)Rejected-Finance | L2 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 3 | L3₹50.0 L+₹36,103.60 (0.73%)Rejected-Finance | L3 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 4 | L4₹50.1 L+₹43,277 (0.87%)Rejected-Finance NO 2 16 KANGAYAMPALAYAM SULFUR PO COIMBATORE 641 401 | COIMBATORE | COIMBATORE | TAMIL NADU | 641401 | L4 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 5 | L5₹51.1 L+₹1.4 L (2.85%)Rejected-Finance | L5 | Rejected-Finance BEING NOT LOWEST TENDER |
Tender Value
Refer Docs
EMD Value
₹99,000
Closing Date
1 Sept 2022, 6:00 pmClosed
GE AF SULUR
Garrison Engineer AF Sulur Military Engineer Services Kangayampalayam Post Sulur Coimbatore 641 401
REPAIR/ MAINT OF GEYSERS, SOLAR WATER HEATERS, INTERNAL ELECTRIFICATION FITTINGS, FIXTURE, MAIN DBs, BLDG EARTHING, INTERNAL ELECTRIC SUPPLY SERVICES AND OTHER MISC E/M WORKS IN SMQS AT AF STN SULUR
2022_MES_545169_1
8509/E8
Open Tender
Miscellaneous Works
Item Rate
304 days
GE AF SULUR
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Yes
GE AF SULUR
₹99,000
Yes
20 Sept 2022
12 Aug 2022
2 Sept 2022
12 Aug 2022
1 Sept 2022
26 Aug 2022
12 Aug 2022 - 22 Aug 2022
Amount
SCHEDULE A BOQ
Demolition of Brickwork/stone boulder masonry, built in cement mortar complete all as specified and as directed.
M&L Fly ash Brick work with Old size brick, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:4 complete all as specified and directed.
Taking down cement plaster on brick or stone walls, or concrete or ceilings etc., including raking out joints, hacking for key, scrubbing down with water, etc., including removal of rubbish off the premises, removal and depositing serviceable materials where directed.
M & L Rendering 10 mm thick in cement mortar on brick or stone or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for applying two coat of oil bound distemper over one coat of putty including preparation of newly plastered surfaces complete all as specified and as directed.
Note for Item No 1 to 6:- The above items are required for making good the disturbed surfaces of wall/ ceiling during execution of electrical repairs.
Inspection, taking down the defective parts, checking alignment and minor repairs of storage water heater 25/35/50 ltr capacity of any type any make vertical/ horizontal type which includes the following complete all as specified and directed:- (a) Inspection, taking out of drain plug & dewatering and refix the same complete all as directed . (b) Checking water tightness of storage tank . (c) Checking stop cocks with outlet/inlet pipe of geysers, pressure reducing valves etc to ensure free movement of water and easy functioning of parts. (d) Inspecting over flow vent pipe connections to ensure water-tightness and proper flow. (e) Checking and correct earth continuity of electrical items. (f) Checking functioning of heating element and correct setting adjustment of thermostat upto 55º C. (g) Alignment of reducing valves, checking of dead weight type high pressure release valve and visual check of fusible plug for its intactness. (h) Replacement of defective spares shall be measured and paid under relevant items mentioned below separately as supply and fix.
Note for Item No 8:- The above job shall be carried out by a trained electrician having ITI in electrical, documentary proof of the education of tradesman shall be produced, before commencement of work.
The entire job will be carried out in entire domestic area of Air Force stn Sulur and necessary documents showing qtr No, bldg No supported with user signature shall be prepared as per format given by Engr-in-charge and will be deposited to concerned JE (E/M) within 24 hrs.
All types of T&P, PVC insulation tape, minor nuts, bolts, washers etc required for maintaining the services shall be provided by contractor without any cost to the department.
S&F Heating element, thread type, 1.5 KW 230 volts, ISI marked suitable for 25/50 ltrs geysers of any capacity and any make, including washer/packing suitably complete all as specified and as directed. Make:- Theeta/Swarna or equivalent approved make.
S&F pressure relieving valve CP brass confirming to relevant IS with washer suitable for 15mm bore GI pipe suitable for 25/50 ltrs geysers complete all as specified and as directed. Make : Leader / Theta or equivalent approved make.
S&F thermostat switch range of 30-80 degree suitable for geysers of 25/50 ltrs capacity (ISI marked) complete all as specified and as directed. Make : Havells/Theeta/Swarna/ Elcon or equivalent approved make.
S&F Glass wool for insulation of Geysers any capacity and any make complete all as directed by the Engr-in-Charge.
S&F Heating element, tikona type, 1.5 KW 230 volts, ISI marked suitable for 25/50 ltrs geysers of any capacity and any make including suitable washer/packing complete all as specified and as directed. Make :Theeta/Swarna or equivalent approved make.
S&F PVC connection for hot/ cold water made of double layer nylon braided and fabric at a pressure of 6kg/sq cm at both ends, 450 mm long, heavy duty with CP brass adopters, washers, suitable for 15 mm bore pipe complete all as specified and as directed.
S&F Indicator lamp for geyser 25/50 ltr capacity of colour green & red complete all as specified and as directed. Make : Usha / Bajaj/ Crompton or equivalent approved make.
S&F Copper inner tank of minimum 20 gauge sheet rated pressure not less than 7kg/sqcm suitable for 25 ltrs capacity geysers (wt not less than 3.75 kg) as per sample complete all as specified and as directed.
S&F brass non return valves, screwed down, high pressure, screwed both ends for 15mm bore iron pipe or for union, ISI marked, complete all as specified and as directed. Make : Seiko, Leader, Zoloto or equivalent approved make.
Cutting and screwing existing steel water tubing 15/20/25 mm bore for addition /alteration required for connections to geysers etc complete all as specified and directed.
S&F bottom cover of MS sheet 20 gauge suitable for 25 ltrs capacity geysers and providing a coat of red oxide primer to inner surface and applying one coat of synthetic enamel paint by spray painting to outer surface complete all as specified and as directed.
S&F provision brazing of inner copper tank Geysers using quality of copper electrode blow lamp welding process brazing length n.exc 10 cm all as specified and directed at site the Engr-in-Charge.
S&F heating element, cup (square) type, 1.5 KW 230 volts, ISI marked suitable for 25/50 ltrs geysers of any capacity and any make including washer/packing suitable complete all as specified and as directed. Make : Theeta/Swarna or equivalent approved make.
M&L PVC connection for hot/ cold water made of double layer nylon braided and fabric at a pressure of 6kg/sq cm at both ends, 600 mm long, heavy duty with CP brass adopters, washers, suitable for 15 mm bore pipe complete all as specified and as directed.
Taking down carefully storage water heater (geyser) 25 ltr capacity of any type, any make from the location by removing the electric & water supply connection and shifted to work shop/MES store yard for repair and re-installation at any location including S&F in repair of heavy duty pin type fastener 4" long and making necessary inlet/outlet electric & water supply connection from existing source to geyser complete all as specified and as directed.
Description all as per Sl item No. 26 here-in-above but 35/50 Ltr capacity.
S&F Heating element, tikona type, 2.00 KW 230 volts, ISI marked suitable for 25/50 ltrs geysers of any capacity and any make including provision of suitable washer/packing complete all as specified and as directed. Make : Theeta/Swarna or equivalent approved make.
M&L for painting of outer surface of 25 ltrs storage type water geysers after cleaning of dust & other organic/inorganic materials if any and applying one coat of synthetic enamel white paint by spray painting and writing MES No on the geyser complete all as specified and as directed.
S&F 25 Ltr capacity in any make, indoor assembly, compatible to existing geyser, with inlet and thermostat pipe with drain plug inclusive of clamps for holding the element with nuts, bolts and gasket complete all as specified and as directed.
S&F Copper inner tank of minimum 20 gauge sheet rated pressure not less than 7 Kg/sqcm suitable for 35/50 ltrs capacity geysers (wt not less than 5.25 kg) as per sample including complete all as specified and as directed.
S&F bottom cover of MS sheet 20 gauge suitable for 35/50 ltrs capacity geysers and providing a coat of red oxide primer to inner surface and applying one coat of synthetic enamel paint by spray painting to outer surface complete all as specified and as directed.
M&L Bottom cover in two pieces for covering the base plate, heating element, thermostat made out of MS sheet 22 gauge as per existing size and shape duly painted with two coat of white synthetic enamel paint over one coat of red oxide primer including preparation of surfaces complete all as specified and as directed.
S&F Heating element, thread type, 2.00 KW 230 volts, ISI marked suitable for 25/50 ltrs geysers of any capacity and any make inlcuding suitable washer/packing complete all as specified and as directed. Make : Theeta/Swarna or equivalent approved make.
S&F 35/50 Ltr capacity in any make indoor assembly, compatible to existing geyser, with inlet and thermostat pipe with drain plug inclusive of clamps for holding the element with nuts, bolts and gasket complete all as specified and as directed.
Dismantling carefully solar storage water heating system including taking down old defective parts of any capacity, any type for following works with testing and refixing the same in original position including all water/ electric connection to entire satisfaction of Engineer-in-charge after carry out servicing as under :- (a) Inspection, opening, of all parts, descaling, washing of inner tank with chemical solution and cleaning of outer cover storage tank. (b) Checking water tightness of storage tank after cleaning. (c) Checking and correcting earth continuity of electrical items. (d) Alignment of reducing valves, checking of dead weight type high pressure release valve and visual check of fusible plug for its intactness. (e) Replacement of damaged solar cells (solar cell shall be measured and paid separately under relevant item) (f) Necessary T&P such as ladder,helper shall be contractor responsibiliy.
M&L for painting of outer surface of 50 ltrs storage type water geysers after cleaning of dust & other organic/inorganic materials if any and applying one coat of synthetic enamel white paint by spray painting and writing MES No on the geyser complete all as specified and as directed.
S&F thermostat switch suitable for solar water heater of any make and size complete all as specified and as directed. Make : USHA / Bajaj / Recold / Theta or equivalent approved make.
S&F heating element 3 KW, 230 volt ISI marked suitable for solar geyser tank of any make, any size complete all as specified and as directed. Make : Theta / Daspas / Recold / Bajaj or equivalent approved make.
S&F Gasket set for solar water heater panel suitable for 100Ltr capacity complete all as specified and as directed.
Supply and fix rotational moulded 300 litres capacity double layered HDPE water storage tanks cylindtrical vertical with closed top as per IS 12701-1996 hoisted and fixed in position, including provn of inlet pipe, over flow pipe, washout pipe etc complete all as specified in SSR Part I and as directed.
S&F bib taps, cast copper alloy, with crutch or butterfly handle, chromium plated, fancy type, screwed down, screwed for 15mm bore iron pipe, ISI marked, complete all as specified and as directed. Make: Seiko, Leader, Jaguar or equivalent approved make.
Supply and fix solar cells to replace the damaged cells in the solar panel for solar water heater 100 Ltr capacity complete all as specified and as directed.
Supply and fix of solar tube as per exisiting type complete all as specified and as directed.
S & F industrial type metal clad plug top & socket single pole and a natural link earth enclosure with MCB SP 20 Amp complete all as specified and as directed.
S&F Stop valves, 15 mm Bore of pipe in mm fancy type, chromium plated , high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed.
S&F ball brass valve high pressure with polythene float and fly nut complete screwed for iron pipe 25mm bore complete all as specified and as directed.
S&F PVC water storage tank cover suitable for 250/ 300 ltrs capacity tank with locking arrangement complete all as specified and directed
Supply and fix solar panel glass suitable for 100 ltrs capacity solar water heater with gasket complete all as specified and as directed.
Supply and Fix of solar water heater tank 100 ltr capacity tank having 1.60 mm thickness low carbon steel with porcelain coating, outer tank should be 0.4 mm thickness stainless steel 202 grade Non Magenetic grade, insulation is PUF 50mm including provn for suitable solar tubes complete all as specified and directed.
Supply and fixing MCB SPN 32/40 amps 240 V complete all as specified and as directed.
S&F in repairs 3 layer PP-R (Polypropylene random copolymer) concealed pipes SDR 7.4 (PN-16) UV stablized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain and brass threaded polypropylene random fittings fixed complete to walls/ceilings or floors of 32 mm (outer dia of pipe) complete all as specified and as directed. Make : Supreme, KPT, Prince or equivalent approved make.
S&F in repairs 3 layer PP-R (Polypropylene random copolymer) concealed pipes SDR 7.4 (PN-16) UV stablized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain and brass threaded polypropylene random fittings fixed complete to walls/ceilings or floors of 25 mm (outer dia of pipe) complete all as specified and as directed. Make : Supreme, KPT, Prince or equivalent approved make.
Note for item No 52 & 53 :- (a) The unit rate shall be include for taking down existing pipe and connections and all fittings as directed.
(b) The unit rate shall be include the cost of short lengths, with all pipe fittings such as bends, tees, short pieces connectors, elbows, reducers, unions, sockets etc and fixing accssories such as pipe hooks, screws clamps etc
(c ) Wall thickness of pipes shall be all as per IS : 15801
S&F ball brass valve high pressure with polythene float and fly nut complete screwed for iron pipe 20mm bore complete all as specified and as directed.
M & L cleaning of service tanks of 250/ 300 ltrs capacity on roof top of bldgs upto five storrey after disconnection from inlet and outlet pipe, removing of float valve of service tank and keep aside safely for reuse drain out water through drain plug, cleaning thoroughly to remove all scales and dirt by brushing internal surface, cleaning properly inside with soda wash, flushing out with fresh water, re-positioning of tank at same place, re-connecting inlet and outlet pipes, closing of drain plug, re-installation of float valve duly cleaned, writing/ labelling the record of cleaning carried out with white bold letter such as "TANK CLEANED ON"--------- (month and year), including removing creepers, vegitation and roots of plants, trees branches on or surrounding of service tank complete all as directed.
M&L for Staging / frame work for Solar water tanks using standard mild steel sections like angle iron / MS pipe / flat iron / sheets etc using steel of Fe 410-W (Gde E-250) quality - A including necessary welding suitable to keep 300 ltrs PVC water tank in repairs complete all as specified and directed by Engr in charge.
M & L Preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint (ordinary tint) over a coat of red oxide zinc chrome primer complete all as specified and directed.
Repair, maintenance and making the continuity of supply for rectifying the defects including taking down defective electrical items such as light point, fan/exhaust fan point, call bell point, socket point 5A/15A, switches, sockets, regulator, lamp holder, brackets, bell, buzzer, push button, ceiling rose, pendent, any type of MCB's, SPN DB's any type of internal light fixtures, any type of lamp, ceiling fan, exhuast fan, geyser, capacitor, replacement of fuse wires and all elcectrical accessories in day to day/door to door maintenance including reconnection with S&F small pieces of elctrical cable of size upto 6 sqmm single core and length not exceeding 0.50m complete all as specified and as directed.
Note:- following shall be part of job under item No 61:-
(a) The above job shall be carried out by a trained electrician having ITI in electrical, documentary proof of the education of tradesman shall be produced before commencement of work.
(b) All bldg light complaints including service connection, submain & internal electric for entire Domestic area of AF Stn sulur shall be attended.
(c) Record of complaints/complaint slip showing qtr No, bldgs No, nature of job supported with users signature shall be prepared as per format directed by Engr-in-charge & will be deposited to concerned JE E/M within 24 hrs.
(d) Necessary complaints slip/complaints register & other stationary required shall be contractor responsibility.
(e) All sort of petty T&P items such as PVC insulation table, ladder, galvanised screws, nuts, bolts, washers etc. required to accomplish the job shall be provided by the contractor with out any extra cost to dept.
(f) Defective items if any, required to be replaced shall be measured and paid separately.
(g) The quoted rate is deemed to be inclusive for small pieces of elctrical cable of size upto 10 sqmm single core and length not exceeding 0.50m
(h) The contractor shall maintain a record of all urgent/ routine works and if the work is repeated due to poor workmanship, he will be liable to repair the same without any extra expenditure to the Govt.
(j) In case of any delay in attending the complaint more than 12 hrs after handing over routine/urgent complaints, the contractor shall be liable to pay the penalty as described in penalty clause given here as under.
(k) The penalty shall be applicable to the contractor if the delay is noticed by the Engr-in-Cahrge more than twelve hrs after handing over works of urgent/ routine nature to the contractor. The Engr-in-Charge shall handover the slip containing specification of work to the contractor by lodging the time and signature of contractor be obtained on slip. The contractor shall attend the complaint immediately and shall report to Engr-in-Charge with in 12 hrs. The contractor will keep his tradesmen in stand by for attending any routine / urgent works from the executive. If the nature of job is such that the work cannot be completed within period of 12hrs then the facts shall be brought to the notice of the GE/Engr-in-Charge and the period for the working to the complaint shall be decided by the GE/EIC. If the delay is more then twelve hrs period and the GE is not satisfied with the reason for delay then penalty at the rate of Rs 50/- per job shall be deducted from the dues of the contractor. Please note that this penalty is exclusively other then the condition 56 of IAFW - 2249 and shall be treated as interim condition of the contract and shall be enforce above as and when delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt.
(l) The decision of the Accepting Officer in this regard shall be final and binding.
Supply & fix switch piano flush type 5 Amps 240 volts single pole one way. Make : Anchor (Model Penta PC), Havells (Reo), SSK (Topline) or equivalent approved make.
Supply & fix switch piano flush type 5 Amps 240 volts single pole two way. Make : Anchor (Model Penta PC), Havells (Reo), SSK (Topline) or equivalent approved make.
All as per item No 74 here-in-before but 15 Amp Make : Anchor (Model Penta PC), Havells (Reo), SSK (Topline) or equivalent approved make.
Supply & fix shuttered socket outlet 3 pin 5 amps, flush type
Supply & fix shuttered socket outlet 2 in 1, 5 pin, 5 and15 amps
Supply & fix switch socket combination out let 3 pin 5 amps, flush type.
Supply & fix switch socket combination out let 5 in 1, 5 pin 5 and 15 amps, flush type.
Supply & fix for Ceiling rose 3 plates flush type 6 Amps,250 volts AC ISI marked,
Supply & fix lamp holder, insulated body, cord grip pattern SP 230 volt, complete all as specified and as directed.
Supply & fix electronic fan regulator 230 volts, step type socket type, hum free 100/240 watt. Make : Havells / Schnieder/ crabtree or equivalent approved make.
Supply & fix PVC gang box 1 way 05 amp . Make. Cona/SSK/Anchor or equivalent approved make.
Supply & fix Electronic ballast for 36/40 W flourecent tube light fittngs, 230V, Make : Sumo Slim EBE(Slim) 136 TLD 240 of Philips or equivalent of Bajaj/Crompton Greaves (CG) or equivalent approved make.
Supply & fix starter for 40W flourecent tube light fittngs 1x40 /2x40 watts 230V. Make : Philips/ Bajaj/ CG or equivalent approved make.
Supply & fix single pole MCB 6 to 32 Amps, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996 all as specified (Make/Model : Lexic MCB of MDS Legrand Cat No :408587 to 408595 / Siemens/ Schnieder or equivalent approved make.
Supply & fix electric bell, AC 230 volt, single pole Ding Dong type complete all as specified and directed. Make : Anchor/ cona/ Plaza or equivalent approved make.
Supply & fix 7 watt LED lamp complete all as specified and directed. Make : Philips/ Bajaj/ Crompton Greaves or equivalent approved make.
Supply & fix 2.5 mfd condensor for ceiling fan complete all as specified and directed. Make : Epcos/ Asian/ Tyton or equivalent approved make.
Supply & fix plug top 3 pin 15 amps AC 230 volts complete all as specified and directed. Make : Havells/ Cona/ Plaza or equivalent approved make.
Supply & fix plug top 3 pin 5 amps AC 230 volts complete all as specified and directed. Make : Havells/ Cona/ Plaza
Supply & fix bakelite sheet not less than 3 mm thick of size 100 x 100 mm complete all as specified and as directed. Make : Hylam/ Formica/ Green laminated boards or equivalent approved make.
Supply & fix TP, MCB 40 to 63 amp, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 all as specified (Make/Model : Siemens/ Schneider/ L&T or equivalent approved make.
Supply & fix TPN, MCB 20 to 32 amp, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 all as specified (Make/Model : Siemens/ Schneider/ L&T or equivalent approved make.
Supply & fix electronic fan regulator modular typre 230 volts, step type socket type, hum free 100/240 watt Make : Havells / Schnieder/ Crabtree or equivalent approved make.
Supply & fix insulation tape 25 mm width 10m long
Supply & fix PVC rectangular/square block 75mmx75mmx35mm
Supply & fix Electronic ballast for 2 x 36/40 W flourecent tube light fittngs, 230V, Make : Sumo Slim EBE 236 TLD 240 of Philips or equivalent of Bajaj/CG or equivalent approved make.
Supply & fix 4' 20W/ 18W LED tube rod suitable for existing fitting. Make : Philips, Bajaj, Havells or equivalent approved make.
Supply & fix bell push. Make : Anchor/ Cona/ Havells or equivalent approved make.
Supply & fix bell push, modular 1 way
Supply & fix Electronic ballast for 28W TL5 lamp flourecent tube light fittngs, 240V, Make : Sumo Slim EBE 128 TL5 240 of Philips or equivalent of Bajaj/CG or equivalent approved make.
Supply & fix Electronic ballast for 1x18 W flourecent tube light fittngs, 230V, Make : Philips or equivalent of Bajaj/CG or equivalent approved make.
Supply & fix PVC gang box 2 way 15 amp . Make. Cona/SSK/Anchor or equivalent approved make.
Supply & fix bakelite sheet not less than 3 mm thick of size 200 x 250mm complete all as specified and as directed. Make : Hylam/ Formica/ Green laminated boards or equivalent approved make.
Supply & fix bakelite sheet not less than 3 mm thick of size 250 x 300mm complete all as specified and as directed. Make : Hylam/ Formica/ Green laminated boards or equivalent approved make.
Supply & fix 4 mfd condensor for ceiling fan complete all as specified and directed. Make : Epcos/ Asian/ Tyton or equivalent approved make.
Supply & fix electric buzzer, AC 230 volt, single pole complete all as specified and directed. Make : Anchor/ cona/ Plaza or equivalent approved make.
Supply & fix modular switch 1 way 6 amp.1 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti) or equivalent approved make.
Supply & fix modular Socket, 6A - 2/3 pin combined 2 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti) or equivalent approved make.
Supply & fix modular switch 1 way 16 amp.1 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti) or equivalent approved make.
Supply & fix modular Socket, 16A - 2/3 pin combined 2 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti) or equivalent approved make.
Supply & fix modular white cover plate with frame,3 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti) or equivalent approved make.
Supply & fix modular white cover plate with frame,4 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti) or equivalent approved make.
Supply & fix modular white cover plate with frame,6 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti) or equivalent approved make.
Supply & fix in repair rigid, non-matalic, PVC conduit pipe, ISI marked, 32 mm bore, including bends, saddles, accessories complete all as specified and as directed. Make : Prince/ Supreme/ Diplast or equivalent approved make.
Supply & fix in repair rigid, non-matalic, PVC conduit pipe, ISI marked, 25 mm bore, including bends, saddles, accessories complete all as specified and as directed. Make : Prince/ Supreme/ Diplast or equivalent approved make.
Supply & fix switch socket combination outlet 3 in 1/ 3 pin 3 and 5 amps flush type with box
Supply & fix switch socket combination outlet 5 in 1/ 5 pin 5 and 15 amps flush type with box
Supply & fix electronic fan regulator 230 volts, step type, switch type, hum free 100/ 240 watt. Make : Anchor/ Cona/ Havells or equivalent approved make.
Supply & fix Double pole MCB 40 amp, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 all as specified Make/Model : Siemens/ ABB/ Legrand or equivalent approved make.
Supply & fix in repair PVC batten of 15 mm (width) complete all as specified and directed. Make : Polycab/Modi/ Presto Plast or equivalent approved make.
Supply & fix in repair PVC batten of 20 mm (width) complete all as specified and directed. Make : Polycab/Modi/ Presto Plast or equivalent approved make.
Supply & fix in repair PVC batten of 25 mm (width) complete all as specified and directed. Make : Polycab/Modi/ Presto Plast or equivalent approved make.
Supply & fix TPN, MCB 40 to 63 amp, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 all as specified Make/Model : Siemens/ ABB/ Legrand or equivalent approved make.
Supply & fix 9 watt LED lamp complete all as specified and directed. Make : Philips/ Bajaj/ CG or equivalent approved make.
Supply & fix of 4 pin 18 watt CFL. Make: Crompton Greaves/ Havells/ Osram or equivalent approved make.
Supply & fix of 4 pin 36 watt CFL. Make: Crompton Greaves/ Havells/ Osram or equivalent approved make.
Supply & fix PVC gang box 2 way 05 amp . Make. Cona/SSK/Anchor or equivalent approved make.
Supply & fix bakelite sheet not less than 3 mm thick of size 175 x 100mm complete all as specified and as directed. Make : Hylam/ Formica/ Green laminated boards or equivalent approved make.
Supply & fix bakelite sheet not less than 3 mm thick of size 200 x 200mm complete all as specified and as directed. Make : Hylam/ Formica/ Green laminated boards or equivalent approved make.
M&L for Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed to wall/floors along with one run of 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note:- (a) 2 runs of 4 sqmm cable along with one run of 4 sqmm cable for earth conductor and one run of PVC casing capping shall be measured as one length. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 6 sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed to wall/floors along with one run of 6 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note:- (a) 2 runs of 6 sqmm cable along with one run of 6 sqmm cable for earth conductor and one run of PVC casing capping shall be measured as one length. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
S&F in replacement factory made powder coated distribution board VTPN, 8 way double door including bus bar, Neutral bar, standard DIN rail, earth bar complete all as specified and conforming to IS: 8623 all as specified. Make/Model : Siemens/ Schnieder/ Legrand or equivalent approved make.
S&F in replacement factory made powder coated distribution board VTPN, 4 way double door including bus bar, Neutral bar, standard DIN rail, earth bar complete all as specified and conforming to IS: 8623 all as specified. Make/Model : Siemens/ Schnieder/ Legrand or equivalent approved make.
S&F in replacement factory made powder coated distribution board TPN, 4 way double door including bus bar, Neutral bar, standard DIN rail, earth bar complete all as specified and conforming to IS: 8623 all as specified. Make/Model : Siemens/ Schnieder/ Legrand or equivalent approved make.
S&F in repairs Electronic energy meter single Phase 5 to 30Amps range capacity complete all as specified. Make : BENTEC / L&T/ABB or equivalent approved make. Note :- Old unserviceable meter shall be deposited to E/M store yard.
M&L for wiring for circuit complete submain wiring with 2 runs of 1.5 sqmm single core PVC insulated, unsheathed FRLS 100 Volt grade multi stranded copper conductor cable drawn through and incl suitable dia rigid PVC conduit and accessories complete fixed surface to wall/roof/ceiling etc and incl onr run of 1.5 sqmm single core wire PVC insulated, unsheathed FRLS 1100v grade multi stranded copper conductor cable as earth continuity conductor etc including taking down existing sub main wiring of any size and all as specified. Note:- (a) 2 runs of 1.5 sqmm cable along with one run of 1.5 sqmm cable for earth conductor and one run of PVC conduit shall be measured as one length. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
M&L for Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 sqmm drawn through in and incl suitable size PVC Conduit and all accessories fixed to wall/floors along with one run of 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note:- (a) 2 runs of 4 sqmm cable along with one run of 4 sqmm cable for earth conductor and one run of PVC conduit shall be measured as one length. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 6 sqmm drawn through in and incl suitable size PVC conduit and all accessories fixed to wall/floors along with one run of 6 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note:- (a) 2 runs of 6 sqmm cable along with one run of 6 sqmm cable for earth conductor and one run of PVC conduit shall be measured as one length. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
S&F factory made powder coated distribution board SP & N 8 way double door, including bus bar, Neutral bar, standard DIN rail, earth bar complete all as specified and conforming to IS: 8623 all as specified. Make/Model : Siemens/ Schnieder/ ABB or equivalent approved make.
S&F in replacement factory made powder coated distribution board TPN, 4 way single door including bus bar, Neutral bar, standard DIN rail, earth bar complete all as specified and conforming to IS: 8623 all as specified. Make/Model : Siemens/ Schnieder/ ABB or equivalent approved make.
S&F in replacement on distribution board MCCB four pole, 100 Amp ultimate breaking capacity 16 KA complete conforming to IEC -61439-1 complete all as specified. Make : Siemens/ L&T/ ABB or equivalent approved make.
S&F integrated LED bulk head luminarie fittings in engineering plastic housing with clear prismatic /opal diffuser /pressure aluminium die cast housing in white powder coating minimum IP-65 protection, system wattage not more than 10 watt (lumen output not less than 800 lumen) power factor more than 0.9, with surge protection device minimum 2KV, colour temperature not less than 5700K, LED driver with constant output voltage and current at input voltage of 140 Volt to 285 Volt AC at 50 Hz, glarefree, 0 UV radiation light fitting with wall mounting arrangement and making connections with PVC insulated copper conductor 3 core cable of 0.5 sqmm. Make : Wipro Cat part NO.LW07-4-XXX-57-G1 or equivalent in Philips Wipro/ Bajaj or equivalent approved make.
S&F in repairs Electronic energy meter 3 Phase 30 to 60Amps range capacity. Make : BENTEC / L&T/ABB or equivalent approved make. Note :- Old unserviceable meter shall be deposited to E/M store yard.
M&L for sub main wiring with PVC insulated unsheathed FRLS 1100 volts grade multi stranded copper conductor cable 4 runs of 6 sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed to wall/floors along with two runs of 6 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note:- (a) 4 runs of 6 sqmm cable along with two runs of 6 sqmm cable for earth conductor and one run of PVC casing caping shall be measured as one length. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
S&F factory made powder coated distribution board SP & N 4 way double door, including bus bar, Neutral bar, standard DIN rail, earth bar complete all as specified and conforming to IS: 8623 all as specified. Make/Model : Siemens/ Schnieder/ Legrand or equivalent approved make.
S&F in replacement on distribution board MCCB four pole, 63 Amp ultimate breaking capacity 16 KA complete conforming to IEC -61439-1 complete all as specified. Make : Siemens/ L&T/ ABB or equivalent approved make.
Supply & fix in repair 5 watt LED lamp complete all as specified and directed. Make : Philips/ Bajaj/ CG or equivalent approved make.
Supply and Fixing indoor decorative extruded aluminium anodised housing /CRCA sheet steel coated housing (suitably coated to improve resistance against corrosion) LED T8 batten type luminaire (LED batten shall be prewired box type) retrofit solution with and including replaceable retrofit cool day white LED tube rod with well designed aluminium heat sink /aluminium housing for excellent heat dissipation; 2 feet (appx) size, high efficiency electronic driver, system wattage 10 watt (lumen output not less than 1000 lumen), power factor more than 0.9, with surge protection device minimum 3KV, colour temperature not less than 5700K, LED driver with constant output voltage and current at input voltage of 140 Volt to 285 Volt AC at 50 Hz, CRI more than 80, glarefree, no UV radiation light fitting with wall mounting arrangement and making connections with PVC insulated copper conductor 3 core cable of 0.5 sqmm complete all as specified and directed. Make : Philips Cat part No.LHEXACP7IN1W00 or equivalent in Wipro/ Bajaj or equivalent approved make.
Taking down aluminum/copper point wiring on & including hard wood battens, surface conduit and board/ blocks etc or through conduits for light, socket or power point, fan point complete (Taking down of fittings such as switches, sockets, bells, ceiling rose, holders , regulators, light fittings, MCB, lamps etc shall be measured and paid seperately) and making good the disturbed plaster surfaces of wall, floor, ceiling and painting 2 coat of white wash/distamber to meet the existing surface and removing materials and debris to reinstate the premise neat and clean complete all as specified and directed.
M&L point wiring using approved colour coding as per IS for one light/bell/buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade ISI 694 marked cable for phase & neutral drawn through concealed PVC Conduit, ISI marked with and including new MS/ cast iron sunken boxes duly painted with two coats of anticorrosive paint over a coat of red oxide primer on surface in touch with wall and synthetic enamel paint over a coat of red oxide on other side, covered with 3mm thick plastic laminated sheet for mounting switches, regulators, sockets etc including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed. Make of Conduit : Avon Plast/ Supreme/ Diplast or equivalent approved make. Make of Wire : Plaza/ Polycab/ Havells or equivalent approved make.
One light point/fan/bell point controlled by one switch
All as per item No. 153 here in before but for one 3 pin socket out 5 amp on the same board
All as per item No. 153 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 153 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
M&L point wiring using approved colour coding as per IS for one light/bell/buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through PVC casing Caping with and including new MS/ cast iron sunken boxes duly painted with two coats of anticorrosive paint over a coat of red oxide primer on surface in touch with wall and synthetic enamel paint over a coat of red oxide on other side, covered with 3mm thick plastic laminated sheet for mounting switches, regulators, sockets etc including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed. Make of Casing Capping : Polycab/ Modi/ Presto Plast or equivalent approved make. Make of Wire : Plaza/ Polycab/ Havells or equivalent approved make.
One light point/fan/bell point controlled by one switch
All as per item No. 158 here in before but for One 3 pin socket out 5 amp on the same board
All as per item No. 158 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 158 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
Supply and Fixing indoor decorative extruded aluminium anodised housing /CRCA sheet steel coated housing (suitably coated to improve resistance against corrosion) LED T8 batten type luminaire (LED batten shall be prewired box type) retrofit solution with and including replaceable retrofit cool day white LED tube rod with well designed aluminium heat sink /aluminium housing for excellent heat dissipation; 4 feet (appx) size, high efficiency electronic driver, system wattage 20 watt (lumen output not less than 2000 lumen), power factor more than 0.9, with surge protection device minimum 3KV, colour temperature not less than 5700K, LED driver with constant output voltage and current at input voltage of 140 Volt to 285 Volt AC at 50 Hz, CRI more than 80, glarefree, no UV radiation light fitting with wall mounting arrangement and making connections with PVC insulated copper conductor 3 core cable of 0.5 sqmm complete all as specified and directed. Make : Philips Cat part No.LHEXBLP7IN1W020 or equivalent in Wipro/ Bajaj or equivalent approved make.
M&L for point wiring complete with 1.5 sqmm single core PVC insulated, unsheathed fire retacable 1100 volts grade, multi stranded with copper conductor drawn through and incl PVC casing caping with accessories in wall/roof/ceiling etc incl MS modular terminal boxes, concealed surface to walls covered with modular plates with cover etc and 1.5 sqmm PVC insulated, unsheathed copper conductor multistranded cable 1100V grade as earth continuity conductor & connecting to common earth dolly all as specified for Make of Casing Capping : Polycab/ Modi/ Presto Plast or equivalent approved make. Make of Wire : Plaza/ Polycab/ Havells or equivalent approved make. Note: (a) Switches, sockets outlets, blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separetely). (b) Connection of wire with switch, socket shall be through copper thumble (lugs) only.
One light point/fan/bell point controlled by one switch
All as per item No. 164 here in before but for One 3 pin socket out 5 amp on the same board
All as per item No. 164 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 164 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
M&L for point wiring complete with 1.5 sqmm single core PVC insulated, unsheathed fire retacable 1100 volts grade, multi stranded with copper conductor drawn through and incl PVC Conduit with accessories in wall/roof/ceiling etc incl MS modular terminal boxes, concealed surface to walls covered with modular plates with cover etc and 1.5 sqmm PVC insulated, unsheathed copper conductor multistranded cable 1100V grade as earth continuity conductor & connecting to common earth dolly all as specified for Make of Cable : Plaza/ Polycab/ Havells or equivalent approved make. Make of Conduit : Supreme/ Diplast/ Avon Plast or equivalent approved make. Note: (a) Switches, sockets outlets, blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separetely). (b) Connection of wire with switch, socket shall be through copper thumble (lugs) only.
One light point/fan/bell point controlled by one switch
All as per item No. 169 here in before but for One 3 pin socket out 5 amp on the same board
All as per item No. 169 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 169 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
Supply and Fix in repair switch piano flush type 5 Amps 240 volts single pole one way. Make : Anchor (Model Penta PC), Havells (Reo), SSK (Topline) or equivalent approved make.
Supply and Fix switch in repair piano flush type 15 Amps 240 volts single pole one way. Make : Anchor (Model Penta PC), Havells (Reo), SSK (Topline) or equivalent approved make.
Supply and Fix in repair shuttered socket outlet 3 pin 5 amps, flush type
Supply and Fix in repair shuttered socket outlet 2 in 1, 3 pin, 5 and15 amps
Supply and Fix in repair modular switch 1 way 6 amp.1 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti) or equivalent approved make.
Supply and Fix in repair modular Socket, 6A - 2/3 pin combined 2 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti) or equivalent approved make.
Supply and Fix in repair modular switch 1 way 16 amp.1 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti) or equivalent approved make.
Supply and Fix in repair modular Socket, 16A - 2/3 pin combined 2 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti) or equivalent approved make.
S&F Surface & wall mounted LED fitting including 5 watt LED tube rod complete with all accessories internally, pre-wired, connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed. Make : Philips Cat part No.LHEXBLP7IN1W005 or equivalent in Wipro/ Bajaj or equivalent approved make.
M&L for sub main wiring with PVC insulated unsheathed FRLS 1100 volts grade multi stranded copper conductor cable 4 runs of 4 sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed to wall/floors along with two runs of 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note:- (a) 4 runs of 4 sqmm cable along with two runs of 4 sqmm cable for earth conductor and one run of PVC casing caping shall be measured as one length. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
Supply and fixing building security luminaire of watt 10 watt LED 1000 lumens light High power LED, with unique peanut lens to ensure uniform distribution, higher spacing between poles and maintenance free system with excellent thermal management including prewired and all as specified and directed, Make : Philips/ Wipro/ Bajaj or equivalent approved make.
Supply and fixing electronic driver 10W suitable for bldg security light of make : Bajaj/ Philips all as directed by Engineer-in-Charge.
Supply and fixing electronic driver 20W suitable for bldg security light of make : Bajaj/ Philips all as directed by Engineer-in-Charge.
S&F 9 watt surface mounted sleek square down lighter enviornment friendly, new generation, energy saving with high power LED as light sources & clear glass including accessories complete all as specified and as directed. Make : Philips/ Wipro/ Bajaj or equivalent approved make.
M&L for taking down of ceiling fan of size 1200/1400mm for safety checking by replacing defective parts/painting/rewinding and re-fixing the ceiling fan after repairs,all as specified and as directed by Engr-in-charge. (Note:- The replacement of unserviceable items like capacitor, Bearings, Bush, Canopy, down rod etc.shall be made as directed by the Engineer-in-Charge which will be measured and paid separately under respective items as Supply and fix. However, parts of minor nature such as screws, lugs, insulation tape, nuts, bolts, washers etc after cleaning the metal surface, greasing/lubricant etc to make it functional and making connection by replacing PVC insulated unsheathed cable of copper conduct of size 1.5 Sqmm from ceiling rose/ connector fan (up to 0.50 Mtr length) including cost of labour for taking down the defective parts for above replacement are deemed to be inclusive in quoted rate all as directed.
Supply and fix rotor of ceiling fan of any size
Supply and fix fan canopies for ceiling fan size of 1200mm/1400mm
Supply and fix gun metal bush of suitable size for ceiling fan 1200mm /1400 mm sweep
Supply and fix fan bearing suitable for ceiling fan 1200mm /1400 mm sweep (bearing with 8 balls shall be used ) Make:- NBC/TATA/SKF or equivalent approved make.
Supply and fix down rod for ceiling fan with 15mm dia (of length not less than 45cm and not more than 60cm) with hanging clamps for ceiling fan complete all as specified and directed.
Supply and fix Rubber reel bushes for ceiling fan of size 1200/1400mm
Supply and fix 'U' clamp for hanging ceiling fan with all nuts, bolts and washers.
Supply and fix outer body of ceiling fan of any size
Supply and fix blades (made of aluminum) suitable for 1400mm sweep ceiling fan of any make with set of screws complete all as specified and directed.
Supply and fix safety pins 40mm to 50mm long with nuts and bolt with washers for ceiling fan of size 1200/1400mm
Supply and fix blades (made of aluminum) suitable for 1200mm sweep ceiling fan of any make with set of screws complete all as specified and directed .
Supply and fix down rod for ceiling fan with 15mm dia (of length not less than 90cm and not more than 120cm) with hanging clamps for ceiling fan complete all as specified and directed.
Supply and fix down rod for ceiling fan with 15mm dia (of length not less than 180cm and not more than 210cm) with hanging clamps for ceiling fan complete all as specified and directed.
M&L painting the ceiling fan 1200mm /1400 mm sweep with one coat of syntetic enamel paint as existing colour and writing the MES No- as directed by Engr in Charge.(taking down of fan, and re hanging measured under item No. 1 seperately. Note:- Painting of ceiling fan shall be done inside MES complex only.
Material and labour for winding of ceiling fan motor 1200 mm sweep of any make with super enameled copper winding wire of existing gauge (wt of copper winding wire per fan 350 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size 0.0076mm of length not more than one meter with each fan complete all as specified and directed. Note :- Motor shall be wound with machine inside MES complex only.
Description all as per Sl item No 203 here in above but ceiling fan of 1400 mm sweep
Supply and fixing in replacement of unserviceable energy efficeint Ceiling fan 1200mm sweep, energy efficient ISI mark with 5 star rating 230 Volts AC 50 Hz, single phase including provision of fixing arrangement, nut and bolt and flexible 3 core of size 1.5 sqmm not less than 0.5 m long complete including taking down existing one, writing MES No with synthetic enamel paint all as specified and as directed. Make : Havells cat Part No. ES Neo/ Bajaj/ Orient or equivalent approved make. Note:- (a) The contractor shall given a written guarantee of minimum two years from completion of work. (b) Old Unserviceable ceiling fan shall be deposited to MES store yard.
Taking down of exhuast fan any size/capacity after disconnecting cable connection, and refixing same in original position after necessary repair/over hauling etc complete all as specified and directed. However, The replacement of unserviceable items like Louvers, Bearings, Bush, etc. shall be made as directed by the Engineer-in-Charge which will be measured and paid separately under respective items as Supply & fix, but replacement of parts of minor nature such as screws, lugs, insulation tape, nuts, bolts, washers etc after cleaning the metal surface, greasing/lubricant etc to make it functional and making connection by replacing PVC insulated unsheathed cable of copper conduct of size 1.5 Sqmm from ceiling rose/ connector fan (up to 0.50 Mtr length) including cost of labour for taking down the defective parts for above replacement are deemed to be inclusive in quoted rate all as directed.
Material and labour for winding of Exhuast fan 300 mm sweep of any make with super enameled copper winding wire of existing gauge (wt of copper winding wire per fan 250 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size 0.0076mm of length not more than one meter with each fan complete all as specified and directed. Note :- Motor shall be wound with machine inside MES complex only.
Description all as per Sl item No 207 here in above but 250 mm sweep
Description all as per Sl item No 207 here in above but 200 mm sweep
Supply and fix fan bush of suitable size for exhaust fan of the any sweep
Supply and fix metal louvers of suitable size for exhaust fan of the 300mm sweep
Supply and fix fan bearing of suitable size for exhaust fan of 300mm sweep including greasing.
Supply and fix metal louvers of suitable size for exhaust fan of the 250/200 mm sweep
Supply and fix fan bearing of suitable size for exhaust fan of 250/200 mm sweep including greasing.
M&L painting the exhaust fan of 300mm sweep with one coat of syntetic enamel paint as exiting colour and writing the MES No and return to MES storeyard /user unit from the work shop .as directed by Engr in Charge. Note:- Painting of ceiling fan shall be done inside MES complex only.
All as per item No 215 above but 250 mm sweep
All as per item No 215 above but 200 mm sweep
S&F Domestic Exhaust Fans for kitchen, 300 mm sweep, 230 volt suqare type, heavy duty, 1400 RPM, corrosion less mild steel body of motor, plastic/ fibre blade for noise less operation, self operating louvers gives powerful performance round the clock, including necessary cutting, making holes on stone/brick walls where required, fixing arrangement with MS pipe 350 mm dia of required length for protect deshape of stone masonery, suitable hold fast with necessary nut, bolts / screws including taking down existing one writing MES No with synthetic enamel paint all specified and directed. Make- havells model-Ventil Air-DB/ bajaj/ Almonard or equivalent approved make. Note:- Old Unserviceable domestic exhaust fan shall be deposited to MES store yard.
S&F Exhaust fan 200 mm sweep 230 volt square type, heavy duty with louvers of PVC body including necessary nut, bolts / screws including taking down existing one writing MES No with synthetic enamel paint all specified and directed. Make-Havells Cat No Ventil DX-WH/BLK/ bajaj, Crompton Greaves or equivalent approved make. Note:- Old Unserviceable Exhaust fan shall be deposited to MES store yard.
M&L Earthing with Galvanised Earth Plate Electrode 600x600x 6mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with Galvanised Earth Strip of size 25x6mm (upto 7.5m length) by means of Bolts, Nuts, Check Nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar including GI 40mm bore (dia) light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt, Magneisum Sulphate (1 : 1 : 0.5) in alternate layers of not exc 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50 mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, Funnel with GI Watering Pipe 20mm bore (dia) medium grade including necessary Excavation in any type of soil, Returning, Filling in and Removal of surplus Spoil disposal to out side MD land and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including taking down old unserviceable one, complete all as per specified and as directed.
Note for Item here in above :- (a) All Joints should be joined by Exothermic Welding or Brazing.
(b) After completion of work earthing shall be tested by the contractor in presence of Engineer-in-Charge, User and proper record shall be maintained duly signed by all concerned.
(c) Earth resistance tester shall be provided by the contractor. It should be caliberated from authorised company/ lab.
(d) After testing if desired earth resistance of less than 5 Ohm is not obtained, the earthing will be redone at no extra cost to Govt till desired result is obtained.
M&L in repairs Galvanised Earth strip of size 25 x 4 mm fixed on proper post insulator at the instrument end complete all as per specified and as directed.
G Perumal and co
SARAVANARAJA CONSTRUCTIONS
KSR AND COMPANY
NAVEEN ENTERPRISES
devan enterprises
Lucky Enterprises
D.R ASSOCIATES
ANAND REFRIGERATION
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .