Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | l1₹1.9 LAccepted-AOC 108 BIBIZAI CHOURAHA NEAR GANDHAK FACTORY SHAHJAHANPUR UTTAR PRADESH 242001 | SHAHJAHANPUR | UTTAR PRADESH | 242001 | l1 | Accepted-AOC l1 | |
| 2 | l2₹2.2 L+₹23,231 (12.0%)Rejected-Finance 268 KARGALI BAZAR BERMO BOKARO 829104 JHARKHAND | BOKARO | BOKARO | JHARKHAND | 829104 | l2 | Rejected-Finance l2 | |
| 3 | Rejected-Technical AT KARGALI BAZAR BERMO DIST BOKARO JHARKHAND PIN 829104 | BERMO | BOKARO | JHARKHAND | 829104 | - | Rejected-Technical Not as per NIT |
| Sl No | Description | Qty | Unit | M/s Jai Hanuman Enterprises L1 | M/s Kiran Electrical works L2 |
|---|---|---|---|---|---|
| 1.01 | Erection of Metalic Pole of above 10 meter and upto 12 meter in cement concrete 1:3:6 (1 cement:3coarse sand:6graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc as required | 9 | no. | 6,050 ₹54,450 Lowest | 6,750 ₹60,750 |
| 1.02 | Erection of ACSR conductor of 7/3.35 mm to 7/4.00 diameter and above including binding etc. as required (6 span x 50 m x 3 wire) x 0.394 kg/m = 354.6 kg (Dog conductor) | 354.6 | kg. | 190 ₹67,374 Lowest | 210 ₹74,466 |
| 1.03 | Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for two 11 KV over head line conductors complete with 50 mm x 50 mm x 6 mm angle iron bracket welded to the channel iron and complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required. | 4 | no. | 1,850 ₹7,400 Lowest | 2,250 ₹9,000 |
| 1.04 | Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) pole top bracket/ cross arm for single 11 KV over head line conductor complete with 50 mm X 6mm flat iron clamp, bolts, nuts and washers including drilling holes for insulator pins, bolts and nuts etc and painting with primer and finish paint as required. | 5 | set | 1,650 ₹8,250 Lowest | 1,750 ₹8,750 |
| 1.05 | Erection of pole top/ straight two wire/ V shape two wire, angle iron/ channel iron, cross arm on steel tubular/ rail/ PCC pole for 11/22/ 33 KV as required. | 10 | set | 400 ₹4,000 Lowest | 500 ₹5,000 |
| 1.06 | Supplying of two lengths of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) double pole cross arm for three wire 11KV over head line conductors complete with through bolts and nuts for clamping to the poles, 50 mm X 6 mm M.S. flats welded on one side to the channel iron and with bolts and nuts on the other side for tying the cross arms together, including drilling holes for insulator pins/ fittings, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required. | 2 | set | 3,950 ₹7,900 Lowest | 4,500 ₹9,000 |
| 1.07 | Erection of double pole 3 wire cross arm for 11KV/ 22KV/ 33 KV over head lines as required. | 4 | no. | 850 ₹3,400 Lowest | 1,000 ₹4,000 |
| 1.08 | Supplying and erection of 11 kV Pin Insulator complete with large steel head G.I. Pin, nuts, washers, etc., as required. | 15 | set | 225 ₹3,375 Lowest | 250 ₹3,750 |
| 1.09 | Erection of 6 SWG G.I. wire (for Earthing & Cradling): (50 m x 3) x 3 span + (50 m x 7) span = 800 m x 0.116 kg = 92.8 kg | 92.8 | kg | 30 ₹2,784 Lowest | 35 ₹3,248 |
| 1.10 | Supplying and erection of galvanised stay set for 11 KV over head lines complete with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm thick, thimble, stay clamps, turn buckle (20 mm X 600 mm ), 7/ 4.00 mm dia G.I. stay wire and 11 KV strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required. | 6 | no. | 4,100 ₹24,600 Lowest | 4,500 ₹27,000 |
Tender Value
₹2.3 L
EMD Value
₹2,900
Closing Date
13 Jan 2025, 9:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
PE EnM Karo OCP
OFFICE OF PE EnM Karo OCP
Diversion cum erection of a portion of the 3.3 kV Workshop Feeder, w.r.t. Karo OCP, under BnK Area
2025_CCL_324698_1
P.E. (EnM)/ Karo OCP/ e-tender/ 2024-25/ 85
Open Tender
Electrical and Maintenance Works
Item Rate
7 days
KARO OCP
Please refer Tender documents.
3 documents required · 3 mandatory
₹2,900
28 Sept 2026
2 Jan 2025
14 Jan 2025
2 Jan 2025
13 Jan 2025
3 Jan 2025
2 Jan 2025 - 13 Jan 2025
Amount
Erection of Metalic Pole of above 10 meter and upto 12 meter in cement concrete 1:3:6 (1 cement:3coarse sand:6graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc as required
Erection of ACSR conductor of 7/3.35 mm to 7/4.00 diameter and above including binding etc. as required (6 span x 50 m x 3 wire) x 0.394 kg/m = 354.6 kg (Dog conductor)
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for two 11 KV over head line conductors complete with 50 mm x 50 mm x 6 mm angle iron bracket welded to the channel iron and complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required.
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) pole top bracket/ cross arm for single 11 KV over head line conductor complete with 50 mm X 6mm flat iron clamp, bolts, nuts and washers including drilling holes for insulator pins, bolts and nuts etc and painting with primer and finish paint as required.
Erection of pole top/ straight two wire/ V shape two wire, angle iron/ channel iron, cross arm on steel tubular/ rail/ PCC pole for 11/22/ 33 KV as required.
Supplying of two lengths of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) double pole cross arm for three wire 11KV over head line conductors complete with through bolts and nuts for clamping to the poles, 50 mm X 6 mm M.S. flats welded on one side to the channel iron and with bolts and nuts on the other side for tying the cross arms together, including drilling holes for insulator pins/ fittings, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required.
Erection of double pole 3 wire cross arm for 11KV/ 22KV/ 33 KV over head lines as required.
Supplying and erection of 11 kV Pin Insulator complete with large steel head G.I. Pin, nuts, washers, etc., as required.
Erection of 6 SWG G.I. wire (for Earthing & Cradling): (50 m x 3) x 3 span + (50 m x 7) span = 800 m x 0.116 kg = 92.8 kg
Supplying and erection of galvanised stay set for 11 KV over head lines complete with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm thick, thimble, stay clamps, turn buckle (20 mm X 600 mm ), 7/ 4.00 mm dia G.I. stay wire and 11 KV strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required.
Supplying & erection of 11 KV disc insulator for 11 KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required.
Total impact of GST for the purpose of CTC
M/s Kiran Electrical works (BID ID -1116599)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .