Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.9 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹31.0 L+₹1.1 L (3.55%)Rejected-Finance 6 GOODS SHED ROAD TITAGARH KOLKATA 700119 | TITAGARH | NORTH 24 PARGANAS | WEST BENGAL | 700119 | L2 | Rejected-Finance Highest | |
| 3 | L3₹31.9 L+₹1.9 L (6.49%)Rejected-Finance B 16 280 KALYANI NADIA 741235 | KALYANI | NADIA | WEST BENGAL | 741235 | L3 | Rejected-Finance Highest | |
| 4 | L4₹32.4 L+₹2.5 L (8.27%)Rejected-Finance 86 TOLLYGUNGE CIRCULAR ROAD KOLKATA WEST BENGAL 700053 | KOLKATA | KOLKATA | WEST BENGAL | 700053 | L4 | Rejected-Finance Highest | |
| 5 | L5₹38.6 L+₹8.7 L (28.9%)Rejected-Finance A 8 SAKHARAM GANESH DAUSKAR SARANI KOLKATA 700 025 | KOLKATA | KOLKATA | WEST BENGAL | 700025 | L5 | Rejected-Finance Highest |
Tender Value
Refer Docs
EMD Value
₹59,000
Closing Date
8 Sept 2020, 2:00 pmClosed
Superintending Engineer PWD Electrical
Superintending Engineer PWD North Bengal Electrical Circle P.W.D Inspection Bungalow Annex Building 1ST Floor Kutchery Road Venus More Siliguri
S.I.T.C of Air Conditioner Machines at CCU ICCU Recovery Room SNCU Principal Office M OT Morgue and other site of North Bengal Medical College and Hospital Campus in the district of Darjeeling
2020_WBPWD_293780_1
WBPWD/SENBEC/NIT-17/2020-2021
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
North Bengal Medical College and Hospital
Please refer Tender documents.
4 documents required · 4 mandatory
₹59,000
16 Sept 2020
22 Aug 2020
10 Sept 2020
22 Aug 2020
8 Sept 2020
26 Aug 2020
Amount
Dismantling the existing Window / Split type RAC machine carefully from its original location and covering this existing position by acp / Eboard including carying & deposited to section store as instructed by the EIC
HIWALL SPLIT AIR CONDITIONING Supply & Delivery of Hi-wall Split Air Conditioner having following specification. Cooling Capacity(KCal/Hr) - 6000 KCal/Hr ISEER Rating - 3 Star/2018-2019 as per BEE/BIS IS compliance - IS 1391 Refrigerant - R410A Compressor - Rotary/Scroll Evaporator & Condensor Coil : Copper Operating Outdoor Temparature = 50ºC and above Power Supply - 240V,50Hz ( +Tolerrance as per applicable standard) [Make: O General / Zamil / MITSUBISHI ELECTRIC / TOSHIBA]
Installation, Testing & Commissioning of Indoor & Outdoor unit of above Hi wall split AC machine after making hole in wall etc as per direction of EIC including S&F of necessary fixing arrangement for indoor and outdoor unit, duly painted, laying and making connection of refrigeration pipe, power cable, drain pipe etc as per direction of the EIC. The scope of work is also includes supply of following (i) Necessary refrigeration copper line with nitrial rubber insulation - 3 mtr (ii) necessary copper cable (FRLSZH type - make : Finolex / Havells / Polycab / RR Kable / Gloster) - 3mtr
S&F of additional following items for length exceeding 3 mtr for complete installation and commissioning of aboove AC machines.
(i) Supply & Fixing of extra refrigerant pipe with insulation foam insulation (as requisite dia)
(ii) 3 core PVC insulated FRLSZH grade copper cable (Make : Finolex / Havells / Polycab)
Supply & Fixing of PVC drain pipe 1" dia (make approved by EIC)
SUPPLY and delivery of 7.5TR capacity concealed type Split Air Conditioner of rated cooling capacity of 90000 BTU/hr. with 3Nos. twin rotary compressor,3nos. IDU of rated power supply-230V-1ph-50Hz. , 1no. ODU of rated power supply-400V-3ph-50Hz. Air-flow/per IDU:- 1000CFM. (Make: Hitachi / Daikin / O General)[ Principal Room, Morque Seminar Room]
Erection & Commissioning Charges for minimum7.5TR Air Conditioner
S&F of additional following items for complete installation and commissioning of aboove AC machines.
(i) Supply & Fixing of extra refrigerant pipe with insulation foam insulation (as requisite dia)
(ii) 3 core PVC insulated FRLSZH grade copper cable (Make : Finolex / Havells / Polycab)(required size)
Supply & Fixing of PVC drain pipe 1" dia (make approved by EIC)
Supply and fixing flexible canvass connection for Ductable & Concealed Split air-conditioners.
Charges for drop ceiling to cover the Indoor Units made of ACP 3mm thik (Make Aludecor or pwd approved
Supplying, fabrication & fixing M.S u-channel of 6 mm thick of size (75 mm x 40 mm x 40 mm) for making platform for installation of outdoor unit of 7.5TR Ductable & Concealed split AC incl. drilling 2 nos holes in each channel including cutting holes into the wall & grouting the same with cement concrete (1:1 ½ :3) etc. fabricated with horizontal angle of 25 mm x 25 mm x 6 mm including supporting angle 50 mm x50mm x 6 mm in each platform.The platform should be baricaded & safe for ODU Maintenance. Area of the platform is as per Machine configuration & load with adequate service access as per direction of EIC (for single ODU unit)
Supplying and Drawing 1.1 KV single core stranded 'FRLS' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the polythene pipe and by the prelaid GI fish wire and making necy. connection as required 2X4sqmm+1X2.5sqmm. (For A/c machine)
Supply & Fixing 240 V, 20 A Piano key type switch Brand approved by EIC) on sheet metal switch board incl. S & F 100x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
Supply & Fixing of 230V 50Hz 25A AC Starter OLP 3+ including four module modular Box and allied necy electrical connection.Make Electron or as per choice of E.I.C
NOTE Special Terms & Conditions :- i) The Agency must procure the materials from the Manufacturer / OEM or from their authorized. Sales channel so that the standard warranty / Support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them
ii) Documents that authenticates such procurement form the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM /authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution of work/submission of bill. iii) If any refurbished material is supplied and installed, panel action will be taken as per e
ARATI ENTERPRISE
REFRICON
Lyric International
MAXCOOL REFRIGERATION CO.
SKY DECORATIONS PRIVATE LIMITED
CARRION AIR COOLING
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .