| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 CrAccepted-AOC NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | ₹1.5 Cr | L1 | Accepted-AOC Being L1 |
| 2 | L2₹1.5 Cr+₹3.7 L (2.47%)Rejected-Finance NO 439 AHIV ADAN 11ND FLOOR 2RD STAGE INDIRA NAGAR BANGALORE 560 075 | BENGALURU URBAN | KARNATAKA | 560075 | ₹1.5 Cr+₹3.7 L (2.47%) | L2 | Rejected-Finance Not being L1 |
| 3 | L3₹1.5 Cr+₹3.7 L (2.48%)Rejected-Finance NO 83 THAMMAIAH GARDEN ABBIGERE CHIKKABANAVARA PO BANGALORE 560 090 | BENGALURU URBAN | KARNATAKA | 560090 | ₹1.5 Cr+₹3.7 L (2.48%) | L3 | Rejected-Finance Not being L1 |
| 4 | L4₹1.7 Cr+₹20.7 L (13.9%)Rejected-Finance 606 80 FEET ROAD 7TH BLOCK 2ND PHASE BANASHANKARI 3RD STAGE BANGALORE 560 085 | BENGALURU URBAN | KARNATAKA | 560085 | ₹1.7 Cr+₹20.7 L (13.9%) | L4 | Rejected-Finance Not being L1 |
| Sl No | Description | Qty | Unit | M/S SRI BALAJI ENTERPRISES L3 | devan enterprises L1 | Shiva Shakthi Electrical Enterprises L2 | Lucky Enterprises L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | Supply, installation, testing & commssioning of HT 11 kV, 3 Ph, 50 Hz totally enclosed ( metal enclouser) SF6 gas insulated switchgear having rated current carrying capacity upto 630 A, with 02 way Outdoor Ring Main Unit with 2 Isolator , (type CC+) , CU busbar,Type 2 way manual operated, outdoor, one side -extensible, with aluminium bus bar of 630 A capacity and coupling arrangement to connect the existing RMU of make ABB/Siemens complete comprising of (2 LBS) , rated power frequency voltage 28 kV, rated impulse withstand voltage 75 kV, rated current for ring main feeder - 630 A, ambient temperature (-5 deg to +55 deg celsius), design ambient temperature (40 degree C), including foundation as per OEM recommendation complete all as directed . The Cable boxes shall be suitably provided towards front/rear side, for 1 X 3C x 120 sq mm XLPE Cable with right angle Cable Termination protectors complete all as specified and as directed. | 4 | EACH JOB | 3,75,000 ₹15,00,000 | 2,90,000 ₹11,60,000 | 3,40,000 ₹13,60,000 | 34,850 ₹1,39,400 Lowest |
| 2.00 | Supply, installation, testing & commssioning of HT 11 kV, 3 Ph, 50 Hz totally enclosed ( metal enclouser) SF6 gas insulated switchgear having rated current carrying capacity upto 630 A, with 03 way Outdoor Ring Main Unit with 3 Isolator , (type CCC+) , CU busbar,Type 3 way manual operated, outdoor, one side -extensible, with aluminium bus bar of 630 A capacity and coupling arrangement to connect the existing RMU of make ABB/Siemens complete comprising of (3 LBS) , rated power frequency voltage 28 kV, rated impluse withstand voltage 75 kV, rated current for ring main feeder - 630 A, ambient temperature (-5 deg to +55 deg celsius), design ambient temperature (40 degree C), including foundation as per OEM recommendation complete all as directed . The Cable boxes shall be suitably provided towards front/rear side, for 1 X 3C x 120 sq mm XLPE Cable with right angle Cable Termination protectors complete all as specified and as directed. | 1 | EACH JOB | 4,65,000 ₹4,65,000 | 4,35,000 ₹4,35,000 | 6,10,000 ₹6,10,000 | 48,900 ₹48,900 Lowest |
| 3.00 | Supply, installation, testing & commssioningof HT 11kV,3Ph,50Hz totally enclosed( metal enclouser) SF6 gas insulated switchgear having rated current carrying capacity upto 630A, with 03 way Outdoor Ring Main Unit with 2 Isolator , 1 VCB ( type CCV+) with 01 set of Protection CT of ratio 40/1A , 2.5VA , 5P10 - 1 set for each VCB, STC 21kA for 3Sec ,IAC AFLR 21kA for 1sec ,CU busbar,Type 3 way manual operated,outdoor,one side -extensible,oudoor comprising of (2 LBS+1 VCBs) in a single unit (VCB to be manual), rated power frequency voltage 28kV,rated impluse withstand voltage 75kV,rated current for ring main feeder -630A,rated current for VCB 630A,short time current (ik)-21kA for 3sec,rated short making current 50kV,ambient temperature (-5deg to +55deg celsius),design ambient temperature (40degree C),with IP 54 Each Vacuum Circuit breaker including foundation as per OEM recommendation complete all as directed . The Cable boxes suitable towards front/rear side, for 1 X 3C x 400 sq mm XLPE Cable as incomer & 1x 3C x 120 sqmm as outgoing with right angle Cable Termination protectors complete all as specified and as directed. | 1 | EACH JOB | 6,15,000 ₹6,15,000 | 6,21,000 ₹6,21,000 | 4,40,000 ₹4,40,000 Lowest | 6,78,000 ₹6,78,000 |
| 3.01Note for item Ser No 1 to 3 :- (a) Only OEM make RMUs are acceptable. RMUs manufactured & supplied in the name of System integrator / Franchise partners /License Partners of OEM are not acceptable. SF6 Gas tank, RMU shall be manufactured by OEM in whose name for type tests are issued. | |||||||
| 3.02(b) Load break switch (630A) should have the following :- (i) Manual operated 12 KV, 630A Load Break switch and Earthing Switch with making capacity (ii) “Live Cable” LED Indicators through Capacitor Voltage Dividers mounted on the bushings (iii) Mechanical ON/OFF/EARTH Indication (iv) Anti-reflex operating handle (v) Cable Testing facility after opening the cable covers after doing the earthing suitably and without disconnecting the Cable terminations. (vi) Cable boxes suitable for 1x3Cx120 sq mm XLPE Cable with right angle Cable Termination Protectors | |||||||
| 3.03(vii) Cable Door should be arc proof and interlocked with respective Earthing Switches. For safety of operator it should not be possible to open the cable Door unless the earth Switch is ON. (viii) It should consist of an SF6 cubicle housing a switch disconnector and an earthing switch. Bus bars and all electrical connections are located inside the tank. The switch positions are closed – open – earthed. The operating shafts for the switches should be have rotary seals where they enter the SF6 cubicle. The operating mechanisms should be located outside on the front of the SF6 tank. Cable bushings shall be site replaceable type. Front covers containing the mimic diagram and having a degree of protection IP2X close the fronts. | |||||||
| 3.04(c) Circuit Breaker (630A) should have the following: (i) Manual operated 630 A Vacuum circuit breaker and Earthing Switch with making capacity (ii) Fault arc Interruption should be in Vacuum only. (iii) Auxiliary contacts 2NO and 2NC (iv) Anti-reflex operating handle (v) “Live Cable” LED Indicators thrugh Capacitor Voltage Dividers mounted on the bushings. (vi) 3O/C + 1E/F self powered relay with Low and high set for Over current and Earth Fault. Relay should have facility to trip the breaker from remote commands without requiring shunt trip coil. It shall be communicable via MODBUS Communication (vii) Mechanical ON/OFF/EARTH Indication. (viia) Protection CT 40/1A , 2.5VA , 5P10 - 1 set for each VCB (vii) Cable boxes suitable towards front/rear side, for 1 X 3C x 120 sq mm XLPE Cable with right angle Cable Termination protectors | |||||||
| 3.05(viii) The 630 Amp T-off circuit breaker module should consist of an SF6 cubicle with high grade SS 304 Tank housing a fixed type vacuum circuit breaker and a series disconnector & earthing switch. Current rating less than 630Amp is not permissible. An integrated relay and related CTs is used for tripping of the circuit breaker. Use of SF6 as Fault-interruption media is not allowed, because of safety and environmental reasons. Bus bars and all electrical connections should be located inside the tank. The operating shafts for the switches should be have rotary seals where they enter the SF6 cubicle. The operating mechanisms are located outside on the front of the SF6 tank. Cable bushings shall be site replaceable type so that in an unforeseen event of bushing breakage , the entire RMU shouldn’t be sent back to the factory. Front covers containing the mimic diagram having a degree of protection IP2X seal off the fronts. (ix) Vacuum bottles should be used as interrupters of the fault-currents & Vacuum bottle manufacturer should be same as RMU manufacturer. The make of vacuum bottles should be same as that of RMU. (x) The Earthing switch shall be fault making type only . i.e. earthing should not involve Vacuum breaker as the total number of VCB operations will reduce if every earthing operation is via VCB . (xi) Extension arrangement shall be provided as per existing RMU at site at the time of fixing and cost of same shall be included in the rate quoted. | |||||||
| 4.00 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cable, foundation etc, and getting out in soft /loose soil complete all as specified and as directed. | 2,100 | CUM | 350 ₹7,35,000 | 300 ₹6,30,000 | 260 ₹5,46,000 Lowest | 390 ₹8,19,000 |
| 5.00 | Returning filling in including spreading, leveling Watering and well ramming in layers not exceeding 25cm complete all as specified and as directed. | 1,450 | CUM | 65 ₹94,250 | 130 ₹1,88,500 | 30 ₹43,500 Lowest | 140 ₹2,03,000 |
Tender Value
₹1.4 Cr
EMD Value
₹2.2 L
Closing Date
29 Dec 2025, 6:00 pmClosed
Ranjeet Kumar, IDSE, CWE
Commander Works Engineers AF South Gangamma Circle Opp Guard Room 410 AFS Jalahalli Bangalore 560013
SPECIAL REPAIRS / REPLACEMENT OF HT EQUIPMENTS, CABLES , PROTECTIVE SWITCH GEARS AND ALLIED WORKS EAST AND WEST AREA AT AFS JALAHALLI
2025_MES_742372_1
85361/E8
Open Tender
Civil Works
Item Rate
180 days
GE (M) (AF) Jalahalli
As per Tender Document
8 documents required · 8 mandatory
₹1,000
GE (M) (AF) Jalahalli
₹2.2 L
Yes
31 Jan 2026
1 Dec 2025
5 Jan 2026
1 Dec 2025
29 Dec 2025
22 Dec 2025
1 Dec 2025 - 8 Dec 2025
Amount
Supply, installation, testing & commssioning of HT 11 kV, 3 Ph, 50 Hz totally enclosed ( metal enclouser) SF6 gas insulated switchgear having rated current carrying capacity upto 630 A, with 02 way Outdoor Ring Main Unit with 2 Isolator , (type CC+) , CU busbar,Type 2 way manual operated, outdoor, one side -extensible, with aluminium bus bar of 630 A capacity and coupling arrangement to connect the existing RMU of make ABB/Siemens complete comprising of (2 LBS) , rated power frequency voltage 28 kV, rated impulse withstand voltage 75 kV, rated current for ring main feeder - 630 A, ambient temperature (-5 deg to +55 deg celsius), design ambient temperature (40 degree C), including foundation as per OEM recommendation complete all as directed . The Cable boxes shall be suitably provided towards front/rear side, for 1 X 3C x 120 sq mm XLPE Cable with right angle Cable Termination protectors complete all as specified and as directed.
Supply, installation, testing & commssioning of HT 11 kV, 3 Ph, 50 Hz totally enclosed ( metal enclouser) SF6 gas insulated switchgear having rated current carrying capacity upto 630 A, with 03 way Outdoor Ring Main Unit with 3 Isolator , (type CCC+) , CU busbar,Type 3 way manual operated, outdoor, one side -extensible, with aluminium bus bar of 630 A capacity and coupling arrangement to connect the existing RMU of make ABB/Siemens complete comprising of (3 LBS) , rated power frequency voltage 28 kV, rated impluse withstand voltage 75 kV, rated current for ring main feeder - 630 A, ambient temperature (-5 deg to +55 deg celsius), design ambient temperature (40 degree C), including foundation as per OEM recommendation complete all as directed . The Cable boxes shall be suitably provided towards front/rear side, for 1 X 3C x 120 sq mm XLPE Cable with right angle Cable Termination protectors complete all as specified and as directed.
Supply, installation, testing & commssioningof HT 11kV,3Ph,50Hz totally enclosed( metal enclouser) SF6 gas insulated switchgear having rated current carrying capacity upto 630A, with 03 way Outdoor Ring Main Unit with 2 Isolator , 1 VCB ( type CCV+) with 01 set of Protection CT of ratio 40/1A , 2.5VA , 5P10 - 1 set for each VCB, STC 21kA for 3Sec ,IAC AFLR 21kA for 1sec ,CU busbar,Type 3 way manual operated,outdoor,one side -extensible,oudoor comprising of (2 LBS+1 VCBs) in a single unit (VCB to be manual), rated power frequency voltage 28kV,rated impluse withstand voltage 75kV,rated current for ring main feeder -630A,rated current for VCB 630A,short time current (ik)-21kA for 3sec,rated short making current 50kV,ambient temperature (-5deg to +55deg celsius),design ambient temperature (40degree C),with IP 54 Each Vacuum Circuit breaker including foundation as per OEM recommendation complete all as directed . The Cable boxes suitable towards front/rear side, for 1 X 3C x 400 sq mm XLPE Cable as incomer & 1x 3C x 120 sqmm as outgoing with right angle Cable Termination protectors complete all as specified and as directed.
Note for item Ser No 1 to 3 :- (a) Only OEM make RMUs are acceptable. RMUs manufactured & supplied in the name of System integrator / Franchise partners /License Partners of OEM are not acceptable. SF6 Gas tank, RMU shall be manufactured by OEM in whose name for type tests are issued.
(b) Load break switch (630A) should have the following :- (i) Manual operated 12 KV, 630A Load Break switch and Earthing Switch with making capacity (ii) “Live Cable” LED Indicators through Capacitor Voltage Dividers mounted on the bushings (iii) Mechanical ON/OFF/EARTH Indication (iv) Anti-reflex operating handle (v) Cable Testing facility after opening the cable covers after doing the earthing suitably and without disconnecting the Cable terminations. (vi) Cable boxes suitable for 1x3Cx120 sq mm XLPE Cable with right angle Cable Termination Protectors
(vii) Cable Door should be arc proof and interlocked with respective Earthing Switches. For safety of operator it should not be possible to open the cable Door unless the earth Switch is ON. (viii) It should consist of an SF6 cubicle housing a switch disconnector and an earthing switch. Bus bars and all electrical connections are located inside the tank. The switch positions are closed – open – earthed. The operating shafts for the switches should be have rotary seals where they enter the SF6 cubicle. The operating mechanisms should be located outside on the front of the SF6 tank. Cable bushings shall be site replaceable type. Front covers containing the mimic diagram and having a degree of protection IP2X close the fronts.
(c) Circuit Breaker (630A) should have the following: (i) Manual operated 630 A Vacuum circuit breaker and Earthing Switch with making capacity (ii) Fault arc Interruption should be in Vacuum only. (iii) Auxiliary contacts 2NO and 2NC (iv) Anti-reflex operating handle (v) “Live Cable” LED Indicators thrugh Capacitor Voltage Dividers mounted on the bushings. (vi) 3O/C + 1E/F self powered relay with Low and high set for Over current and Earth Fault. Relay should have facility to trip the breaker from remote commands without requiring shunt trip coil. It shall be communicable via MODBUS Communication (vii) Mechanical ON/OFF/EARTH Indication. (viia) Protection CT 40/1A , 2.5VA , 5P10 - 1 set for each VCB (vii) Cable boxes suitable towards front/rear side, for 1 X 3C x 120 sq mm XLPE Cable with right angle Cable Termination protectors
(viii) The 630 Amp T-off circuit breaker module should consist of an SF6 cubicle with high grade SS 304 Tank housing a fixed type vacuum circuit breaker and a series disconnector & earthing switch. Current rating less than 630Amp is not permissible. An integrated relay and related CTs is used for tripping of the circuit breaker. Use of SF6 as Fault-interruption media is not allowed, because of safety and environmental reasons. Bus bars and all electrical connections should be located inside the tank. The operating shafts for the switches should be have rotary seals where they enter the SF6 cubicle. The operating mechanisms are located outside on the front of the SF6 tank. Cable bushings shall be site replaceable type so that in an unforeseen event of bushing breakage , the entire RMU shouldn’t be sent back to the factory. Front covers containing the mimic diagram having a degree of protection IP2X seal off the fronts. (ix) Vacuum bottles should be used as interrupters of the fault-currents & Vacuum bottle manufacturer should be same as RMU manufacturer. The make of vacuum bottles should be same as that of RMU. (x) The Earthing switch shall be fault making type only . i.e. earthing should not involve Vacuum breaker as the total number of VCB operations will reduce if every earthing operation is via VCB . (xi) Extension arrangement shall be provided as per existing RMU at site at the time of fixing and cost of same shall be included in the rate quoted.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cable, foundation etc, and getting out in soft /loose soil complete all as specified and as directed.
Returning filling in including spreading, leveling Watering and well ramming in layers not exceeding 25cm complete all as specified and as directed.
Removing excavated surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.
Material and labour for broken stone boulders Hardcore of gauge n.exc 63 mm deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed using power roller exceeding 8 tonne and not exceeding 12 tonne capacity to a true surface with broken stones or boulders all as specified complete all as specified and as directed.
Rough excavation not exceeding 1.5 m deep and getting out in hard / dense soil and complete all as specified and as directed.
Material and labour for sand filling under floors or in foundations including watering, consolidation and complete all as specified and as directed.
Material and Labour for providing cement concrete in foundations, filling and mass concrete Type B1,1:2:4, using 20 mm graded stone aggregate complete all as specified and as directed.
Material and Labour for providing Plain Cement Concrete (1:3:6) type C-2 using 40 mm graded stone aggregate as in coping/collar of poles/ foundation of column for shed including necessary form work complete all as specified and as directed.
Material and Labour for Plain Cement Concrete coping 1:2:4 type B1 (using 20 mm graded stone agg) including necessary form work complete all as specified and as directed.
Material and labour Reinforced Cement Concrete M25 20mm graded stone aggregate for Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, lintel beams etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.
Material and Labour for Cement concrete 1:3:6 type C2 (using 40 mm graded stone agg) as in foundation, filling and for mass concrete complete all as specified and as directed.
Material and Labour in repairs Pre-cast Plain Cement Concrete 1:3:6 type C1 using 20 mm graded stone agg) cement concrete block masonry with solid blocks exceeding 10cm in width and set in cement mortar 1:6 including demolition of old brick work / stone masonry/PCC block built in cement mortar of any description complete all as specified and as directed.
Material and labour for Cement concrete 1:4:8 type D2 in foundations, filling and mass concrete complete all as specified and as directed.
Material and Labour for Spreading ribbed soil in trenches as in cable cushioning all as per IS 1255-1983 complete all as specified and as directed. Note :- Excavated approved soil shall be ribbed by using sieve to separate composite particles etc as per IS and refiiling in trenches before laying of cable 8 CM and 15 CM after laying of cable. Then gently punned down to a depth of 10 cm above the top of upper most cable (ii) For the purpose of measurement and payment only punned thickness only will be considered .
Material and Labour for well burnt sub class ‘B’ bricks as mechanical protection for under ground LT electric cables laid along with length of the bricks equal to the width of the trench complete all as specified and as directed.
Supply & Fixing of mild steel work in framed brackets of angle or tees, flat iron, channels, etc with web flanges cut to shape, drilled and countersunk of screw, including bending and welding angles, bend to curve shape wherever required necessary, gusset plates, riveting, etc. not exceeding, 10 kg each bracket, and hanging also fastening and fixing conforming to Gde Fe 290, Gde E-165, incl painting with 2 coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Material and labour for TMT bars 10mm dia & over cut to length bent to shape required including cranking bending spirally for hoping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with chip with deep quality confirming to FE 500/FE 500D complete all as specified and as directed..
Supply & Fixing in framed work as in doors or gates of angle, tubes or other section with gusset plates, rails, braces,guard bar etc., complete, to be prepared for hanging or sliding with and including hinges or steel hanging door fittings (exclusive of steel sheeting or other covering) and hanging; also fastening and fixing Fe 410 -W (Gde- E- 250) quality-A complete all as specified and directed.
Supply & Fixing Mild Steel Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS.1161-1979 grade St.-240 complete all as specified and directed.
Supply & Fixing Mild Steel angle iron Hand rails, fencing posts, flat iron including embeding in concrete and screwing etc. wind ties for roof including securing bolts, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc., flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
Supply only of chain link fencing Mild Steel galvanised square wire mesh of any size, dia of wire 4mm including line wires, to any type of standard rails, straining bolts, etc complete all as specified and directed.
Fixing only in repairs chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc inlcuding provision of binding wire and dismantling of old fencing wire mesh of any type complete all as specified and as directed.
Supply & Fixing in repairs MS round bars 10 mm dia and over Fe 290 (Gde - E-165) cut to length bent to shape required including cranking, bending spirally, hooping for columns, hooking ends complete all as specified and as directed.
Supply & Fixing in repairs Mild steel screw bolts (machine made) dia of neck 16 to 20mm with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, not exceeding 5cm long, complete all as specified and directed.
Material and Labour for 0.50 mm thick Pre-painted Galvalume zinc coating GI based corrugated steel sheet AZ 150 of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and as directed.
Material and Labour for 100 mm thick Plain Cement Concrete 1:2:4 type B-1 (using 20 mm graded crushed stone agg) as in Hard standing etc. with , spike rolling ,or making impression of expanded metal, while the concrete is green complete all as specified including demolition of old concrete (un reinforced) of any description and in any position not otherwise specifically provided complete all as specified and as directed.
Material and Labour Plain Cement Concrete (1:4:8) type D2 using 40mm graded aggregate 75mm thick as in sub base of floor finished even and rough to receive top layer all as specified and directed and demolition of old concrete (un reinforced) of any description and in any position not otherwise specifically provided complete all as specified and as directed..
Material and labour for machine pressed pre polished precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80mm thickness, M-40 Grade over sand cushion with grey cement and no pigment complete all as specified and as directed.
Material and Labour for rendering 15mm thick in cement mortar (1:4) on brick or concrete surfaces of wall and finishing the surface even and smooth without using extra cement complete all specified and directed.
Material and Labour preparation of newly plastered surfaces of wall and applying three coats of white washing on wall surfaces complete all as specified and directed.
Material and Labour Providing two coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces over 10 cm width or girth including preparation of new steel surfaces complete all as specified and as directed.
Supply & Laying of Telerex DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 120 mm and inner dia 103 mm polythylene including coupler & Bend with smoooth inernal and profiled external surface for non pressue under ground cable complete all as specified and as directed.
Supply & Laying of Telerex DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 110 mm and inner dia 95 mm polythylene including coupler & Bend with smoooth inernal and profiled external surface for non pressue under ground cable complete all as specified and as directed.
Supply & Laying of Telerex DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 90 mm and inner dia 75 mm polythylene including coupler & Bend with smoooth inernal and profiled external surface for non pressue under ground cable complete all as specified and as directed.
Supply & Laying of Telerex DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 63 mm and inner dia 50 mm polythylene including coupler & Bend with smoooth inernal and profiled external surface for non pressue under ground cable complete all as specified and as directed by Engineer-in-Charge
Supply & Laying of Telerex DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 50 mm and inner dia 38 mm polythylene including coupler & Bend with smoooth inernal and profiled external surface for non pressue under ground cable complete all as specified and as directed.
Supply and Fixing Galvanised Iron tubing light grade 40 mm dia fixed on walls/pole/ laid in trenches as protection pipe for under ground cable including provision of specials and clamps etc complete all as speified and directed
Supply and Fixing Galvanised Iron tubing light grade 50 mm dia fixed on walls/pole/ laid in trenches as protection pipe for under ground cable including provisioning of specials and clamps etc complete all as speified and directed
Supply and Fixing Galvanised Iron tubing light grade 80 mm dia fixed on walls/pole/ laid in trenches as protection pipe for under ground cable including provision of specials and clamps etc complete all as speified and directed
Supply and Fixing Galvanised Iron tubing light grade 100 mm dia fixed on walls/pole/ laid in trenches as protection pipe for under ground cable including provision of specials and clamps etc complete all as speified and directed
Dismantling and taking down of old Unserviceable HT Two pole structure with MS iron work and connected fitting / fixture such as insulators of any type, AB switches, DO fuses, Las, earthing strip, Structure foundation, coping, ms bracings, stay assy complete from the existing site all as directed.
Dismantling and taking down of old Unserviceable HT Four pole structure with MS iron work and connected fitting / fixture such as insulators of any type, AB switches, DO fuses, Las, earthing strip, Structure foundation, coping, ms bracings, stay assy complete from the existing site all as directed.
Supply & laying un-reinforced precast concrete cable cover, class HV,Type 1, flat, size 300 mm x 180 mm x 40 mm laid over under ground cable for protection complete all as specified and as directed.
Supply, laying & testing HT electric cable XLPE insulated screened PVC bedded, galvanised steel stip or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor, 11000 volts grade of size 3 core 95 Sqmm (Earthed) complete all as specified and as directed.
Supply, laying & testing HT electric cable XLPE insulated screened PVC bedded, galvanised steel stip or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor, 11000 volts grade of size 3 core 120 Sqmm (Earthed) complete all as specified and as directed.
Material and Labour for cable route indicator made out of Plain Cement Concrete Type B0 1:2:4 (using 12.5mm graded stone aggregate) of size 600 mm x 250 mm x 75 mm with top having semi circle shape and all sides having smooth and fair finshed by using cement slurry/cement mortar duly engraved as 11 KV MES HT CABLE with arrow mark on bothside and painted with 2 coats of synthetic enamal paint of red in colour over a coat of primer on all exterior sides duly grouted the same in Plain Cement Concrete (1:3:6) type C-2 (using 40 mm graded broken stone aggregate) of size 400 x 300 x 300 mm depth below gound level complete all as specified and directed.
Material and Labour for cable route indicator made out of Plain Cement Concrete Type B0 1:2:4 (using 12.5mm graded stone aggregate) of size 600 mm x 250 mm x 75 mm with top having semi circle shape and all sides having smooth and fair finshed by using cement slurry/cement mortar duly engraved as LT MES CABLE with arrow mark on bothside and painted with 2 coats of synthetic enamal paint of yellow in colour over a coat of primer on all exterior sides duly grouted the same in Plain Cement Concrete (1:3:6) type C-2 (using 40 mm graded broken stone aggregate) of size 400 x 300 x 300 mm depth below gound level complete all as specified and directed.
Material and Labour for boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 103 mm dia suitable for 0.4 MPa working pressure for Road crossing in civil authorities all as specified and directed.
Material and Labour for boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 95 mm dia suitable for 0.4 MPa working pressure for Road crossing in civil authorities complete all as specified and as directed.
Supply & Fixing of cable jointing kit for 11 KV grade cable for outdoor termination , heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE , armoured, Aluminium conductor cable of size of 50 sqmm to 95 sqmm complete all as specified and as directed.
Supply & Fixing of cable jointing kit for 11 KV grade cable for outdoor termination , heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE , armoured, Al conductor cable of size of 120 sqmm to 185 sqmm complete all as specified and as directed.
Supply & Fixing of cable jointing kit for 11 KV grade cable for indoor termination , heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE , armoured, Aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and as directed..
Supply & Fixing of cable jointing kit for 11 KV grade cable for indoor termination , heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE , armoured, Aluminium conductor cable of 120 sqmm to 185 sqmm complete all as specified and as directed.
Supply & Fixing of cable jointing kit for 11 KV (E) grade cable for straight through , heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE , armoured, Aluminiumconductor cable of size 120 to 185 sqmm complete all as specified and as directed..
Supply & Fixing of cable jointing kit for 11 KV (E) grade cable for straight through , heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE , armoured, Aluminium conductor cable of size 70 sqmm to 95 sqmm complete all as specified and as directed.
Taking out the existing unserviceable CT unit from the position, Supply and fix epoxy insulated 11 KV grade CT unit 40-100/1A , 2.5VA , 5P10 - 1 of existing size and shape for RMU complete including provision of new control wiring complete all as specified and as directed.
Taking out the existing unserviceable CT unit from the position supply and fix epoxy insulated 11 KV grade CT unit 200/5A, 2.5VA, Burden 5VA, 5P10 -1 of existing size and shape for RMU complete including provision of new control wiring complete all as specified and as directed.
Supply & Fixing in repairs epoxy insulated 11 KV grade PT unit 11kV/110V, Accuracy class 1.0 & Inc Class "E" with provision of new control wiring for RMU complete including taking down the existing unserviceable PT unit complete all as specified and as directed.
Supply & Fixing of new fabricatated high intensity standing HIP reflective sign board made from 2 mm thick hardened plastic aluminium combined sheet and two sheets placed back to back fixed with aluminum pop rivited to stainless steel square pipe of size 40 x 40 mm of 16 guage and frame of size 1300 x 840 mm for E/M installations. The frame support shall be of 25 mm and 50 mm round GI Pipe 2.7 mtr length welded to frame. Top end of legs placed with decorative stainless steel dome on both legs. HIP blue reflective sheet shall be of long lasting superior grade pasted on both side on plastic aluminium combined sheet and above the sheet pasted with weather proof white fluorescent computer aided cut tape of required height and width on sign board and border of white HIP sheet shall be pasted and fixed complete. The sign board shall placed in PCC foundation of size as per site requirement complete all as specified and as directed. Note : Matter for printing shall be provided by the department)
Supply & Fixing of informative sign board for E/M machineries, plants and Schematic diagrams made out of weather proof 3 mm thick rigid white coloured ACP/PVC sheet pasted on one side with coloured HIP refelctive computer aided cut tape of required height pasted on sign board incl fixing arrangements by stainless steel spacers mount stand of nut, bolt of 16 mm dia size fixed with suitable quantity on wall/panels/platform/doors/any description complete all as specified and as directed. Note : Soft copy of matter/drawings for printing shall be provided by the department )
Dismantling concrete poles 9/11 mtr height and struts of any size complete all as specified and as directed.
Dismantling steel poles/struts, any size complete all as specified and as directed.
Dismantling cross-arms of Mild Steel channel or angle sections etc. complete all as specified and as directed.
Dismantling of Aluminium Conductor steel reinforced or AAC conductors complete all as specified and as directed.
Dismantling stay assembly complete all as specified and as directed.
Material and Labour for Rubber mat of 1 meter x 2 meter x 19 mm thick HT type complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with solid single strand aluminium conductor of size 10.0 sq mm 4 core including necessary required aluminium cable lugs/thimbles/GI clamps for fixing on walls and Glands complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with multistrand aluminium conductor of size 25.0 sq mm 4 core including necessary required aluminium cable lugs/thimbles/GI clamps for fixing on walls and Glands complete all as specified and as directed.
Supply, installation, testing and commissioning of smart street light control system using GSM/Lux based technology having 20 KW 3 phase 64 Amp load capacity per phase and can be operated by IVRS/SMS/lux based infrared sensor etc complete with following:- (i) Nature switch operation should be based on natural light lux level. Require illuminnance level for switching on is ≤ 60 lux and for switching off ≥ 10 lux. The smart unit should have 4 timers that can be set via SMS. (ii) Surge protection device (SPD) should provide protection agaist indirect lightning & switching surges. It should conform to IEC61643-11 and should have 40 KA capacity. (iii) The sensor & SPD along with suitable power contactors and incoming-outgoing MCCB/MCBs should be enclosed in a enclosure made of rust proof, electric shock proof , metal weather proof conforming to IP65 with angle iron frame of suitable size 04 Nos legs 600 mm long , PCC 1:2:4 type B1using 20 mm graded aggregate for grouting of base including taking down old unserviceable panel etc complete. The scope of work also comprising the following :- The GPRS shall have seven segment display to show voltage, current, network and street light status , it should also have indicator for showing supply status , timer , overload or high low voltage. It should also able to measure voltage, current and automatic set street light overload current. Unit have facility to call back to registered number for power on/off and if any fault occurs at site.in SMS it should also monitor power/on/off time light on off time, ampere, voltage, unit mode, network percentage date and mobile number who called device number. The device should also have battery backup with minimum 24 hours backup capacity.
The panel should have three operation mode :- 1. GSM mode -in this mode light should be switched as per GSM controller's preset time by user by sms , 4 clock base timer facility should be availble 2. Nature switch based-in this mode light will be switched as per nature light lux level 3. Bypass mode -in this mode light will switched on directly for testing purpose and emeregncy switching .In GSM controller there should be facility to register 4 user by sms/call and alerts will be sent on all registered number and also call back on power on/off and faults on first registered number.The GSM controller should also compatible for cloud based data transmission for interfacing with web for future use, Password protection for Accessing the control of device via SMS/IVRS, complete all as specified and directed including the following subcomponent, supply and fixing features :-
(a) TPN MCCB 100 Amps capacity, 10 KA, 415 Volts -01 No. (Incoming) with separate SPD of 40 KA capacity. (Make of MCCB- L & T, C&S Havells) (b) Supply Resign cast CT'S - set of 3 (c) GSM based smart street light controller. (d) Lux based sensor to operate external as per light intensity. (e) Line Contactor, AC 3 duty, 3 phase, 415 volts. 50 Hz , 32 Amps -02 Nos (make - L & T, BCH, Havells) (f) MCB SP 32 Amps- 06 Nos (make -L & T, BCH, Havells) (g) Terminal block suitable for 100 Amp rating with brass contacts for INPUT/ and 63 Amp for OUTPUT termination. (h) GSM/Timer/Bypass Mode switch. (j) Panel wiring for control circuit with copper flexible 1.5 Sqmm & power wiring 10 Sqmm flexible. Make- Tricolite/ Kewintech/HPL
Mateial and labour of new octagonal Hot Dip GI street light pole of single section 3 mm thick having integral junction box with weather proof door arrangement at 500 mm height from base plate (size of the door shall be of 100 x 500 mm with gasket) having pole size of bottom dia 130 mm & top dia 70 mm, PCD 220 mm, 7.0 mtr height with base plate of size 220x 220 x 12 mm mounted on 4 Nos M 20 x 700 mm 'J' shape GI Fdn bolt, nut and washer complete including necessary earth work, excavation, foundation work by providing PCC 1:3:6 using 20 mm stone aggregate , provision of 1 No MCB SP 6 A rating in the junction box, necessary connector arrangement along with 1 No single arm 1000 mm long GI Street light bracket complete all as specified. Note:- Excavation, earth work, sub mains and RCC foundation will be measured and paid seperately under relevent item of this schedule.
Material and labour as in repair energy efficient street light luminaire LED type 70 watts, IP66 ,230volts, 50 Hz , in Deepdrawn aluminium housing and cast aluminium pipe mounting attachment including suitable heavy duty electronic driver also driver should withstand 265 volts and complete accessories, pre-wired and connection complete with suitable size of stranded copper flexible conductor and one no of 10 KV External SPD fixing in cable junction box complete all as specified and as directed.
Material and labour for sub mains by providing 3 core PVC insulated FRLS copper wire of 1.5 Sqmm multistranded from MCB to light fittings complete all as specified and as directed.
Taking down the existing serviceable LT street light cable of any size/core from the position carefully and relaying / re-routing the same after installing new street light pole and connecting the same by cutting the required length of cable and providing necessary aluminium cable lugs and accessories. etc. complete all as directed. Note : Excavation, earth work and bricks will be measured and paid separately under relevnt item of this schedule.
Supply, installation, testing & commissioning of maintenance free chemical earthing system comprising of 17mm dia copper bonded rod 3 mtr long horizontally pre welded T-terminal rod with provision for connection size of 50 x 150mm long, 6mm thickness with equal space either side, with 12mm dia hole of 02 numbers each on either side of the terminal clamp with 250 microns (average) coating thickness, tested and certified by CPRI India alongwith 50 Kg earth energizer compound and 10 litres earth resistance reducing liquid. The earthing energizer compound and resistance reducing earthing liquid shall be tested as per IEC-62561-7 read with ASTM G57-06, CI 3.4 A by any NABL accredited lab. The above mentioned rod shall be installed in 4-6 inch bore, 12 feet depth with a distance of minimum 3 meters between each installation complete all as specified and directed. Make : Model HTSP 317 of safeTrade or equivalent in Snaga/ Cubes 6 Global
The quoted rate shall also deemed to be included the following :- (i) Prior to installation of maintenance free chemical earthing, soil resistivity test to be carried out at the location where earthing work to be done in presence of Engr-in- Charge/JE (E/M),user and the report has to submit to Garrison Engineer with recommendation of manufacturer, if required additional interconnection of earthing (not more than 08 number of earthing) to achive earth result less then 1 Ohms. The arrangement done for soil resistivity testing and submission of report with recommendation deemed to be included in the quoted rate. (ii) The description/ size/ qty of items mentioned in above are for indicating only however qty/ size may vary at site condition to maintain the earth resistance 1 ohm. The contractor shall quote rate by considering all factors. (iii) Rate of earth energizer compound of 25 Kg of 02 bags and earth resistance reducing liquid 10 litre per cane for each pit deemed to be included in the quoted rate. (iv) Resistivity of earth energizer compound and resistance reducing earthing liquid shall be certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contractor along with the sample approval (v) Earth enhancing material should not leach into the adjacent soil or underground water channels and its PH value should be in neutral range complete all as specified and as directed. It should solidify when mixed with water and set like concrete.
(vi) Copper strip of size 20 x 3 mm shall be fixed on proper post insulator at the instrument end (copper strip upto 7.5 RM shall be considered in unit quoted rate and extra will be measured and paid separately). (vii) Testing of earth shall be carried out in presence of departmental and user representative and report shall be submitted to Garrison Engineer duly signed by all concerned. (viii) Earth resistance tester will be provided by the contractor. Tester should be calibrated from authorised company/ lab. (ix) Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintained duly signed by all concerned. After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained. (x) The contractor shall give a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion. (xi) No further maintenance or periodic watering or recharge shall be required in earthing during its guarantee period of over 03 years in all type of soil including soft/ disintegrated or hard rock.
(xii) During the guarantee period, if earth resistance is not maintained less than 1 ohm the contractor has to redo or rectify at no extra cost to Govt till desired result is maintained. (xiii) A security deposit of value equal to 2.5 % of the rate quoted for chemical earthing for each earthing shall be retained from payment due to the contractor from final bill for the guarantee period. (xiv) The electrode shall carry manufacturer's name . (xv) The connection clamp shall be permanentlly welded to the copper bounded rod to avoid any kind of connectivity loss,.The pre-welded copper bounded rod shall not need any additional clamp for termination. (xvi) The acceptable earth resistance at earth busbar/ test point shall not be more than 0.1 ohm. (xvii) Earth work such as auguring and making good the surrounding area shall carried out in any type of soil. (xviii) The contractor shall submit CPRI India certified document for copper bounded rod to ensure genuineness of material.
(xix) Sign board of mild steel sheet 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxide Zinc chrome primer showing result of earthing shall be fixed near the earth pit after completion as directed by engr -in- charge.
Material and Labour for Earth pit cover made of heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 9.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mm for each electrode pit complete including taking down all as specified and directed. Make : Model SEPC 250 of SAFE TRODE/ Electrogrip Model/ EGTEK3LC of ISG Global or equivalent in other make. Note :- The contractor shall submit load bearing capacity certificate from the manufacturer.
Supply & Fixing Providing Earth continuity conductor or main earthing lead by providing 20 x 3 mm copper strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required complete all as specified and as directed.
Material and Labour for Site clearance by Scraping of grass/wild growth/trees cutting not exceeding 0.30m girth etc in soft/loose soil by manually/mechanically including removing of rubbish from the site to a distance exceeding, 250m but n. exc 500m and deposited where directed at a level not exc. 1.5m above the starting point, complete all as specified and as directed
Forming Construction joints 30 mm deep x 10 mm wide filled with sealing compound grade 'A' complete all as specified and directed.
Dismantling structural steel work including doors, gates etc but excluding framed trusses etc complete all as specified and directed.
Dismantling posts or struts (wood, steel, or RCC) any section, any length not exceeding 5m including taking out embedded portion in concrete, brick work, masonry etc and incl necessary excavation for new post holes complete all as specified and as directed.
Shiva Shakthi Electrical Enterprises (BID ID -3510968)
M/S SRI BALAJI ENTERPRISES (BID ID -3508169)
Lucky Enterprises (BID ID -3516760)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.36 MB
85361Tender.pdf
Tender Documents • 2.67 MB
BOQ_831320.xls
BOQ • 0.64 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .