| 1 | Filtration and dehydration of oil of following indoor transformers | Filtration and dehydration of oil of following indoor transformers for achieving a dielectric strength of minimum 40KV ic testing furnishing test report for each equipment etc as required a 400 KVA indoor transformer | 2 | Jobs | Sanjay Pandurang Kambale And Topping 580021,BSNL Electrical Division, I Indfloor Vidyanagar Telephone Exchange, Near RB Patil Hospital, Hubbali 580021 Up Of Tested Quality Fresh Transformer Oil | 30 |
| 2 | Supplying and topping up of tested quality fresh transformer oil | Supplying and topping up of tested quality fresh transformer oil if required furnishing test report for each equipment etc as required | 50 | Ltr | Sanjay Pandurang Kambale And Fixing 580021,BSNL Electrical Division, I Indfloor Vidyanagar Telephone Exchange, Near RB Patil Hospital, Hubbali 580021 Of Silica Jell | 30 |
| 3 | Supplying and fixing of silica jell | Supplying and fixing of silica jell in polycarbonate breather of the existing 250KVA 400 KVA transformer etc as reqd | 2 | Jobs | Sanjay Pandurang Kambale 580021,BSNL Electrical Division, I Indfloor Vidyanagar Telephone Exchange, Near RB Patil Hospital, Hubbali 580021 | 30 |
| 4 | Servicing of all HT switchgears | Servicing of all HT switchgears on the 11KV outdoor structure provided for incoming BESCOM supply and outgoing supply to transformers such as GOS DOLO fuse unit lightening arresters by cleaning the contacts with emery papers lubricating the moving mechanism Ic taking shut down from EB authorities Grease oil of suitable quality and grade replacing the nut bolts screws washers all GI wherever required | 1 | Job | Sanjay Pandurang Kambale 580021,BSNL Electrical Division, I Indfloor Vidyanagar Telephone Exchange, Near RB Patil Hospital, Hubbali 580021 | 30 |
| 5 | Painting of 11KV outdoor MS structure | Painting of 11KV outdoor MS structure fencing Ic removing the old paint and corrosion by scratching with emery paper and applying one coat of anti corrosive paint and followed by two coats of approved aluminium paint etc complete as reqd | 1 | Job | Sanjay Pandurang Kambale Arresting Of Transformer 580021,BSNL Electrical Division, I Indfloor Vidyanagar Telephone Exchange, Near RB Patil Hospital, Hubbali 580021 Oil Leakage | 30 |
| 6 | Arresting of transformer oil leakage | Arresting of transformer oil leakage including disconnection of HT LT cables removing of transformer top cover replacing gaskets and oil seals reconnecting HT LT cables teasting etc complete as reqd | 1 | Jobs | Sanjay Pandurang Kambale 580021,BSNL Electrical Division, I Indfloor Vidyanagar Telephone Exchange, Near RB Patil Hospital, Hubbali 580021 | 30 |
| 7 | Servicing of 11KV HT panel | Servicing of 11KV HT panel consisting of one incoming from metering cubicle and two outgoing to 2 Nos transformers such as lowering of breakers drawing out from the panel greasing of all the moving components of the switch for smooth functioning checking CT PT etc checking metering portion repositioning the breakers testing with load etc as required | 1 | Job | Sanjay Pandurang Kambale 580021,BSNL Electrical Division, I Indfloor Vidyanagar Telephone Exchange, Near RB Patil Hospital, Hubbali 580021 | 30 |
| 8 | Filtration and dehydration of oil of 11 KV 400 A OCB 11KV HT panel | Filtration and dehydration of oil of 11 KV 400 A OCB 11KV HT panel consisting of one incoming from metering cubicle and two outgoing ic testing furnishing test report for each equipment etc as required | 1 | Job | Sanjay Pandurang Kambale 580021,BSNL Electrical Division, I Indfloor Vidyanagar Telephone Exchange, Near RB Patil Hospital, Hubbali 580021 | 30 |
| 9 | Supplying and keeping of ISI marked 11 KV 33KV rubber hand | Supplying and keeping of ISI marked 11 KV 33KV rubber hand gloves Pair in a suitable water resistant cover as required | 1 | set | Sanjay Pandurang Kambale 580021,BSNL Electrical Division, I Indfloor Vidyanagar Telephone Exchange, Near RB Patil Hospital, Hubbali 580021 | 30 |
| 10 | Supplying and laying of ISI marked 1 dot 1 KV 2mm thick rubber mattings | Supplying and laying of ISI marked 1 dot 1 KV 2mm thick rubber mattings as required | 4 | Sqmtr | Sanjay Pandurang Kambale Calibration Testing Checking 580021,BSNL Electrical Division, I Indfloor Vidyanagar Telephone Exchange, Near RB Patil Hospital, Hubbali 580021 And Correcting Of Pick | 30 |