Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹18.8 LAccepted-AOC VILLAGE MASTIAL PO NAIR TEHSIL JASWAN DISTRICT KANGRA HP | KANGRA | HIMACHAL PRADESH | 175013 | 1 | Accepted-AOC Due to L1 | |
| 2 | 2₹22.0 L+₹28,000 (1.29%)Rejected-Finance 0 MATADIN KAKRAHI KAKRAHI BHARTHANA ETAWA ETAWAH UTTAR PRADESH 206242 | ETAWAH | UTTAR PRADESH | 206242 | 2 | Rejected-Finance Due to L2 | |
| 3 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification | |
| 4 | Not Admitted-Fee/PreQual/Technical CHITRAKALA ART STUDIO GALLERY DREAMLAND JAKHU ROAD SHIMLA 171001 H P | SHIMLA | SHIMLA | HIMACHAL PRADESH | 171001 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification | |
| 5 | Not Admitted-Fee/PreQual/Technical 126 RAJ KUMAR SANGAT SINGH NAGAR ADARSH NAGAR JALANDHAR JALANDHAR PUNJAB 144008 | JALANDHAR | PUNJAB | 144008 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | Arun Rana L1 | Sanjeev Kumar L2 |
|---|---|---|---|---|---|
| 1.00 | Construction of RCC over head tank 70,000 Ltr cap. With 15.00 mtr stagiging height from ground level to bottom of dome slab co mprising of inlet, scour & over flow pipes as per details below from ground level to tank including bends of required degree, confirming to relevants code RCC stair case i/c G.I pipe railing 45 cms. wide if usual hight as per site requirement, Cast iron manhole cover of 500 mm dia and weight of frame and cover should not less than 40 kg. ventilator at top dome with minium opening of 450X450 cms. water level indicator including floats and measuring gauge,lightening conductor with earthing arrangement etc. The RCC over head reservoir shall include randeering/plastering of the uneven exposed surface, two coats of snowcem paint and any other component required for the completion of the job to the entire satisfaction of Engineer-in-charge. The offers shall also include details structural drawing/designe calculations to be approved by the competent authority based on the raft foundation by taking seismic forces in the design calculation expension joints as required at site. The offer shall also include the cost of providing and fixing of GMS/MS pipe, fittings complete including duck foot bends,puddle collars, expansion joints etc. connecting with rising main & distribution main with required length from the edge of foundation and any other component required for the completion of job upto the entire satisfaction of Engineer-in-charge. | 1 | Job | 21,70,000 ₹21,70,000 Lowest | 21,98,000 ₹21,98,000 |
Tender Value
₹19.6 L
EMD Value
₹36,900
Closing Date
14 Jul 2025, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
Jal Shakti Division Amb
Sub Head construction of OHSR 15 mtr. Staging height 70000 ltr. Capacity GP Pramb Saloi at Village Saloi )
2025_HPIPH_109406_1
EE-JSD-Amb-Tender 14.07.2025-Job-10
Open Tender
Civil Works
Item Rate
Amb
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
EE JSD Amb
₹36,900
27 Dec 2025
4 Jul 2025
14 Jul 2025
4 Jul 2025
14 Jul 2025
4 Jul 2025
Amount
Construction of RCC over head tank 70,000 Ltr cap. With 15.00 mtr stagiging height from ground level to bottom of dome slab co mprising of inlet, scour & over flow pipes as per details below from ground level to tank including bends of required degree, confirming to relevants code RCC stair case i/c G.I pipe railing 45 cms. wide if usual hight as per site requirement, Cast iron manhole cover of 500 mm dia and weight of frame and cover should not less than 40 kg. ventilator at top dome with minium opening of 450X450 cms. water level indicator including floats and measuring gauge,lightening conductor with earthing arrangement etc. The RCC over head reservoir shall include randeering/plastering of the uneven exposed surface, two coats of snowcem paint and any other component required for the completion of the job to the entire satisfaction of Engineer-in-charge. The offers shall also include details structural drawing/designe calculations to be approved by the competent authority based on the raft foundation by taking seismic forces in the design calculation expension joints as required at site. The offer shall also include the cost of providing and fixing of GMS/MS pipe, fittings complete including duck foot bends,puddle collars, expansion joints etc. connecting with rising main & distribution main with required length from the edge of foundation and any other component required for the completion of job upto the entire satisfaction of Engineer-in-charge.
Sanjeev Kumar (BID ID -534193)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .