| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.3 LAccepted-AOC ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹7.0 L+₹21,675 (3.21%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹7.3 L+₹54,630 (8.10%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹7.6 L+₹82,948 (12.3%)Rejected-AOC H NO 33 VPO KHERI SALABAT PUR DISTT RUPNAGAR PUNJAB 140111 | RUPNAGAR | RUPNAGAR | PUNJAB | 140111 | L4 | Rejected-AOC Other than lowest | |
| 5 | Rejected-Technical | - | Rejected-Technical Adverse remarks in WLR |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
10 Feb 2025, 6:00 pmClosed
AGE (I) Highground
AGE (I) Highground Chandigarh
REPAIR TO SUMMER APPPLIANCES AC, WATER COOLER, REFRIGRATOR, DEEP FREEZER AT AIR FORCE STATION HIGHGROUNDS UNDER AGE (I) HIGHGROUND
2025_MES_692883_1
AGE(I)/HG CHD/T-29/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE (I) Highground Chandigarh
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
AGE (I) Highground
₹20,000
Yes
24 May 2025
11 Jan 2025
17 Feb 2025
11 Jan 2025
10 Feb 2025
25 Jan 2025
Amount
AIR CONDITIONER
Material and labour for servicing to Split type AC operated on 240 volts single phase AC electric supply of any make/type capacity 1.5/2.0 Ton, both internal / external units of AC, dry cleaning with blower / vacuum cleaner, washing with soap solution and cleaning with water pressure through jet, make it fully serviceable, complete all as specified and as directed.
Supply & fixing sealed unit Rotary Compressor operated on "R-32/R-22 refrigerant" company replaced only suitable for split type AC 1.5 Ton capacity of existing make and model dully filled compressor oil including taking out old US compressor complete all as specified and as directed.
All as per item 3 here - in - before but for AC 2 Ton capacity complete all as specified and as directed.
All as per item 3 here - in - before but for AC 3 Ton capacity complete all as specified and as directed.
Supply & fixing the following spares/parts for split /window type AC unit including taking out old /US spares/parts complete all as specified and as directed.
Copper tube 1/2 inch bore including necessary insulation.
Copper tube 1/4 inch bore including necessary insulation.
Copper tube 5/8 inch bore including necessary insulation.
Insulation for copper tube of any size
Blade only for blower outdoor motor split unit any type.
Contactor suitable for 1.5 ton/2 ton Split AC ant type
Thermostat switch
Running Capacitor 45/6MFD any capacity
Running Capacitor 50/6MFD any capacity
Blower motor for outdoor unit.
Blower motor for indoor unit.
Remote Control system complete including PC Cards /Circuits.
Suction valve for outdoor unit
Capacitor 4MFD 230Volts. Make:Epcos/Usha/Tesla
Capillary tube copper 36mm
Copper filter
Copper Condenser for 1.5 Split AC for outdoor unit
Capacitor 1.5 MFD
Swing flap complete set
PVC filter
PVC blower for indoor unit of existing size and make
Supply and fix PCB indoor unit as per existing for 1.5 TR Split AC
Supply and fix PCB outdoor unit as per existing for 1.5 TR Split AC
Supply and fix PVC rigid water drain pipe 25mm dia complete all as specified and directed.
Supply and fixing flare nut for split ac 1.5/2 ton as required at site complete all as specified and directed
Material and labour for Internal wiring for split unit of any capacity with single core copper conductor FRLS cable as per existing size only complete all as specified and as directed.
Charging of refrigerant gas only after vaccuming dehydration, leak testing of the system as per standard pratice testing for proper cooling effects and satisfactory performance complete all as specified and as directed by Engr-in-charge for room Split/window type AC of capacity 1.5 TR complete all as specified and directed. Note refrigerant gas will be measured and paid separately.
Supply and charging Gas R-22 A or equivalent including necessary arrangement for charging gas & pressure testing complete all as specified and directed.
Supply and charging Gas R-32 A or equivalent including necessary arrangement for charging gas & pressure testing complete all as specified and directed.
Shifting of Split AC from any place and fix at other place all as specified and directed.
REFRIGRATOR
Taking out burnt compressor after disconnecting suction and discharge line Regrigerator of Capaicty 165/180 Litres and supply and fixing compressor and testing the performance all as specified and directed. Note: Re-Charging of gas will be measured and paid separetely.
All as per item No 38 here in - before but for Refrigerator 300 to 320 Litres capacity complete all as specified and as directed.
Supply & Fix in replacement the following items of existing make and model suitable for refrigerator 165/320 capacity including taking out old /US spares / parts complete all as specified and as directed.
Cooling chamber including cooling coil of size shape suitable for refrigerator of size and of capacity 165/180 litres.
Cooling chamber including cooling coil of size shape suitable for refrigerator of size and of capacity 250/286/310 litres.
Thermostat defrost type switch suitable for refrigerator of capacity 165/220/310 litres.
PTC Relay with overload suitable for refrigerator of capacity 165/190/200 litres.
PTC Relay with overload suitable for refrigerator of capacity 250/286/310 Litre.
Condenser coil of suitable for size of refrigeration capacity of 250/280/310 litres .
Magnetic door gasket including fixing accessories for refrigerator of 165/180 Litres capacity.( As per samples)
Magnetic door gasket including fixing accessories for refrigerator of 250/286/310 Litres capacity.( As per samples)
Capillary tube of size 0.36 for any type/size refrigerator.
Thermostate suitable for 250/286/310 litres
Copper pencil strainers of size 4" long double mouth
Wiring set complete consisting of PVC insulated flexible wire with stranded copper conductor of size 1.5 sqmm and fixing clips for refrigerator all types.
Freezer door for 165 litres refrigerator.
Freezer door for 286 to 310 litres refrigerator.
Bimetal 2 wire / 3 wire / 4 wire
Running capacitor 6 / 10 mfd
Forst free fan motor SP 230 volts
Sensor for cooling coil
Defrost timmer of any make of refrigerator
PIN valve for charging refrigerant
Repair to PCB of refrigerator of any capacity and make all as specified and directed
Supply and fix PCB in replacement of any size and capacity
Supply and charging Gas R-134 A or equivalent including necessary arrangement for charging gas & pressure testing complete all as specified and directed.
Charging of refrigerant gas only for refrigerator of size 165 to 320 litres after vaccuming dehydration, leak testing of the system as per standard pratice testing for proper cooling effects and satisfactory performance complete all as specified and as directed.
WATER COOLER
Supply and fixing sealed unit Hermatic Compressor Company replaced only suitable for Water Cooler 40/80Ltrs capacity of existing make and model duly filled of gas, compressor oil including taking out old/US compressor complete all as specified and as directed.
All as per item No 66 here in - before but for Water Cooler 60/120 Ltrs capacity complete all as specified and as directed.
Supply and fixing for replaced to the following items in lieu of provided with new of existing make and model suitable for water cooler any capacity including taking out old /US spares/parts complete all as specified and as directed.
Condensor motor only 1/35 HP
Fan blade only
Push Cock CP 15 mm.
Magnetic Rubber gasket for top cover any capacity.
PVC Drain pipe 32 mm bore not less than 1 metre in length.
Cleaning of water storage tank, detection of water leakage, brazing / welding to restore the leakage, scraping old paint, completely and painted with 2 coat of synthetic enamel paint over a coat of red oxide primer after filling the cavities of MS Sheet with filler to external surface complete all as specified and as directed.
Supply and charging Gas R-132 A or equivalent including necessary arrangement for charging gas & pressure testing complete all as specified and directed.
Charging of refrigerant gas only for water cooler of size 40/80, 60/120, 150 litres after vaccuming dehydration, leak testing of the system as per standard pratice testing for proper cooling effects and satisfactory performance complete all as specified and as directed.
DEEP FREEZER
Taking out burnt compressor for Deep freezer of Capaicty upto 320 Ltrs after disconnecting suction and discharge line and supply and fixing compressor and testing the performance all as specified and directed. Note:-Re Charging of gas will be measured and paid separetely.
Supply and charging Gas R-132 A or equivalent including necessary arrangement for charging gas & pressure testing complete all as specified and directed.
Supply and fixing for replaced to the following items in lieu of provided with new of existing make and model suitable for water cooler any capacity including taking out old /US spares/parts complete all as specified and as directed by Engineer-in-Charge.
Fan motor
Copper Dryer
Charging of refrigerant gas only for deep freezer of size 300 litres after vaccuming dehydration, leak testing of the system as per standard pratice testing for proper cooling effects and satisfactory performance complete all as specified and as directed. Note: Refrigerant gas will be measured and paid separately.
DESERT COOLER
Taking down carefully the following accessories /parts from existing desert cooler in lieu of providing new accessories /parts in desert cooler details as given in below complete all as specified and as directed:-
Fan motor 350 Watts 230 Volts 3 Speed copper winding single phase complete. Make: KHAITAN/Crompton
Submersible type Tulu pump 230Volts single phase 1750LPH at 1.5 mtr head complete Make : KHAITAN/Crompton
Fan blade only
Front girl of M S /PVC complete with slides operation
Wood wool pad set of three of best quality including fixed wth bamboo stick any size.
PVC flexible pipe heavy duty 15mm bore ISI Marked.
PVC Distribution Tee, Elbows and other minor items (heavy duty) 15mm bore
Internal wiring of desert cooler of any capacity
Supply and fix plug top 5 amps three pin .
Taking down desert cooler of any make/capacity carefully without damaging, scraping old paint, completely and painted with 2 coats of synthetic enamel paint over a coat of red oxide primer after filling the cavities of MS Sheet with filler to external surface and inner surface of bottom & sides painted with 2 - coat of black Japan paint completed all as specified and as directed. Note : Taking down and re-fixing in the same position after painting work shall be deemed to include in the unit rate of this item.
VOLTAGE STABILIZER
Material and labour for taking down voltage stabilizer of capacity 3 KVA to 5 KVA single phase 240 volts of any make & type tightening of all electric connections, assembling & testing after repair work including transportation to workshop & vice - versa and connection at site complete all as specified and as directed.
Material and labour for rewinding to burnt transformer of voltage stabilizer 5 KVA with copper winding wire including varnishing with super quality varnish, suitable size of thimble, mica paper and testing after rewinding complete all as specified and as directed.
All as per above item 99 here-in-before but 4 KVA complete all as specified and as directed.
All as per above item 99 here-in-before but 3 KVA complete all as specified and as directed.
Supply and fixing in replacement circuit plate as existing make and model suitable for 5 KVA complete all as specified and as directed.
All as per above item No 102 here-in-before but 4 KVA complete all as specified and as directed by Engineer-in-Charge.
All as per above item No 102 here-in-before but 3 KVA complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repair Time delay relay complete all as specified.
Supply and fix in repair Toggle switch complete all as specified.
Supply and fix in repair Auxiliary transformer up to 24 Volt complete all as specified and directed.
Supply and fix in repair Step up relay complete all as specified and directed.
Supply and fix in repair PVC connector base plate complete all as specified and directed.
Supply and fixing in repair connection lead of PVC insulated and sheathed copper conductor cable of size 1.5 Sqmm 3 core complete all as specified and directed.
All as Srl item No 110 above but of size 2.5 Sqmm. complete all as specified and directed.
Supply,and fix in replacement of voltage stabilizers for automatic operation phase naturally air cooled indoor type & designed for input variation between 170-270 V with output voltage stabilized at 230 Volts with capacity 5KVA. including taking down/ out old/ unserviceable voltage stabilizer complete all as specified and directed. Make :V-GuarD /Carrier/Bluestar
Note: The total amount shall subject to adjustment of credit of Rs 43116.00 for old Materials as per Schedule of Credit
SHRI BALA JI CONSTRUCTION COMPANY (BID ID -3234715)
M/S BALWINDER SINGH (BID ID -3223593)
LA ENTERPRISES (BID ID -3226156)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .