| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.5 LAccepted-Finance 2ND FLOOR COMMERCE CENTRE KULUR KAVOOR ROAD KULUR MANGALORE D K 575 013 | DAKSHINA KANNADA | KARNATAKA | 575013 | ₹14.5 L | L1 | Accepted-Finance Since L1, Accepted by the CA |
| 2 | L2₹16.5 LAccepted-Finance | ₹16.5 L | L2 | Accepted-Finance Not L1, since not Accepted by CA |
| 3 | Not Admitted-Finance | - | - | Not Admitted-Finance Others-Not qualified in Cover 2 as the bidder did not upload the ESI and EPF, so not accepted by CA. |
| Sl No | Description | Qty | Unit | Akey Electro Techniques L2 | M/s Anugraha power services L1 |
|---|---|---|---|---|---|
| 1.00 | Supplying of 1.1 kV, XLPE or Heat resistant PVC insulated, PVC extruded Inner Sheath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-397
3.5 core 240 Sqmm (30 GI strips -4 ×0,8 mm) | 180 | Metrers | 1,700 ₹3.1 L | 1,500 ₹2.7 L |
| 2.00 | Supplying of 1.1 kV, XLPE or Heat resistant PVC insulated, PVC extruded Inner Sheath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-397
4 core 16 Sqmm (11 GI strips -4 ×0,8 mm) | 50 | Metrers | 210 ₹10,500 | 170 ₹8,500 |
| 3.00 | Supplying of 1.1 kV, XLPE or Heat resistant PVC insulated, PVC extruded Inner Sheath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-397
4 core 25 Sqmm (13 GI strips -4 ×0,8 mm) | 50 | Metrers | 276 ₹13,800 | 225 ₹11,250 |
| 4.00 | Earth work excavation in all kinds of soils , Depth up to 1.50 m for pipelines/cables by Manual means up to 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift up to 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work | 6.6 | CMT | 900 ₹5,940 | 450 ₹2,970 |
| 5.00 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminium Rollers as directed by the departmental staff
120 to 240 Sqmm | 180 | Metrers | 75 ₹13,500 | 25 ₹4,500 |
| 6.00 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminium Rollers as directed by the departmental staff
2.5 to 25 Sqmm | 100 | Metrers | 40 ₹4,000 | 12 ₹1,200 |
| 7.00 | Supplying tinned Aluminium lugs and crimping and wiring to terminal point for wire of the following sizes.
240 Sq mm | 14 | Numbers | 335 ₹4,690 | 400 ₹5,600 |
| 8.00 | Supplying tinned Aluminium lugs and crimping and wiring to terminal point for wire of the following sizes.
25 Sq mm | 10 | Numbers | 100 ₹1,000 | 25 ₹250 |
| 9.00 | Supplying tinned Aluminium lugs and crimping and wiring to terminal point for wire of the following sizes.
16 Sq mm | 10 | Numbers | 100 ₹1,000 | 20 ₹200 |
| 10.00 | Supplying and making 3.5 C × (120 TO 225) sq mm heat shrinkable Straight Through Jointing Kit Suitable for 1.1 kV Class LTUG Cable as per IS-13573
3.5C × 240 sq mm | 2 | Numbers | 11,000 ₹22,000 | 8,500 ₹17,000 |
Tender Value
₹16.6 L
Closing Date
15 Jan 2026, 3:00 pmClosed
Deputy Director
NITK SURATHKAL
Providing New Electrical Panel Boards and Wiring works inside Main Electrical Panel Room of CCC Building (Phase 1) - in NITK
2026_NITK_892517_1
Tender No.25/2025-26/ HD
Open Tender
Electrical Works
45 days
Srinivasanagara
As per Tender Document
9 documents required · 9 mandatory
₹0
Exempted
10 Feb 2026
5 Jan 2026
16 Jan 2026
5 Jan 2026
15 Jan 2026
6 Jan 2026
Supplying of 1.1 kV, XLPE or Heat resistant PVC insulated, PVC extruded Inner Sheath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-397 3.5 core 240 Sqmm (30 GI strips -4 ×0,8 mm)
Supplying of 1.1 kV, XLPE or Heat resistant PVC insulated, PVC extruded Inner Sheath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-397 4 core 16 Sqmm (11 GI strips -4 ×0,8 mm)
Supplying of 1.1 kV, XLPE or Heat resistant PVC insulated, PVC extruded Inner Sheath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-397 4 core 25 Sqmm (13 GI strips -4 ×0,8 mm)
Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminium Rollers as directed by the departmental staff 120 to 240 Sqmm
Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminium Rollers as directed by the departmental staff 2.5 to 25 Sqmm
Supplying tinned Aluminium lugs and crimping and wiring to terminal point for wire of the following sizes. 240 Sq mm
Supplying tinned Aluminium lugs and crimping and wiring to terminal point for wire of the following sizes. 25 Sq mm
Supplying tinned Aluminium lugs and crimping and wiring to terminal point for wire of the following sizes. 16 Sq mm
Supplying and making 3.5 C × (120 TO 225) sq mm heat shrinkable Straight Through Jointing Kit Suitable for 1.1 kV Class LTUG Cable as per IS-13573 3.5C × 240 sq mm
Supplying and Fixing of heavy-duty Brass cable glands suitable for UG Cables of 1.1 Kv class A) 75 mm
Supplying and Fixing of heavy-duty Brass cable glands suitable for UG Cables of 1.1 Kv class A) 32 mm
Supplying heavy gauge PVC conduit pipe 19/20mm dia and 2mm thick confirming to IS2509 with suitable size bends, junction boxes, adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall /stone structure or raw plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 19/20 mm dia 2mm thick
Supplying heavy gauge PVC conduit pipe 19/20mm dia and 2mm thick confirming to IS2509 with suitable size bends, junction boxes, adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall /stone structure or raw plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.40 mm dia 2.5 mm thick
Removing the existing cables from the cable duct and dismantling it from panels and retemination work, and dismantling old detoriated panels and cables, Relocating the wiring inside panel room, shifting it to the dept store, including labours, tools, transportation etc complete.
Fabricating supplying and mounting MS box made out16 SWG suitable for floor/wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof flocking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats red oxide primer paints and finally finished with approved colour enamelled metal paint, naming of incoming and outgoing, cable alley with connectors, accessories, as required capacity wires,wirings,control MCBs etc, Suitable size MS C channel with welding work for floor mount should be provided. 420×200×30cm size Panel
Fabricating supplying and mounting MS box made out 16 SWG suitable for floor/wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof flocking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats red oxide primer paints and finally finished with approved colour enamelled metal paint, naming of incoming and outgoing, cable alley with connectors, accessories, as required capacity wires,wirings,control MCBs etc, Suitable size MS C channel with welding work for floor mount should be provided. 300×160×30cm size Panel
Fabricating supplying and mounting MS box made out16 SWG suitable for floor/wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof flocking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats red oxide primer paints and finally finished with approved colour enamelled metal paint, naming of incoming and outgoing, cable alley with connectors, accessories, as required capacity wires,wirings,control MCBs etc, Suitable size MS C channel with welding work for floor mount should be provided. 200×160×30cm size Panel
Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood / panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with adjustable thermal magnetic release, Microprocessor release shall have Earth Fault as per IS/IEC60947-2. (Icu=100%lcs). In 4P MCCB, all Poles should have protection for Short-Circuit /Overload. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. Make: Legrand, ABB, L &T, Schinder a) Four Pole 400 A 36 kA
Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood / panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with adjustable thermal magnetic release, Microprocessor release shall have Earth Fault as per IS/IEC60947-2. (Icu=100%lcs). In 4P MCCB, all Poles should have protection for Short-Circuit /Overload. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. Make: Legrand, ABB, L &T, Schinder a) Four Pole 125 A 25 kA
Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood / panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with adjustable thermal magnetic release, Microprocessor release shall have Earth Fault as per IS/IEC60947-2. (Icu=100%lcs). In 4P MCCB, all Poles should have protection for Short-Circuit /Overload. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. Make: Legrand, ABB, L &T, Schinder a) Four Pole 100 A 25 kA
Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood / panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with adjustable thermal magnetic release, Microprocessor release shall have Earth Fault as per IS/IEC60947-2. (Icu=100%lcs). In 4P MCCB, all Poles should have protection for Short-Circuit /Overload. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. Make: Legrand, ABB, L &T, Schinder a) Four Pole 200 A 25 kA
Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood / panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with adjustable thermal magnetic release, Microprocessor release shall have Earth Fault as per IS/IEC60947-2. (Icu=100%lcs). In 4P MCCB, all Poles should have protection for Short-Circuit /Overload. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. Make: Legrand, ABB, L &T, Schinder a) Four Pole 250 A 25 kA
Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood / panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with adjustable thermal magnetic release, Microprocessor release shall have Earth Fault as per IS/IEC60947-2. (Icu=100%lcs). In 4P MCCB, all Poles should have protection for Short-Circuit /Overload. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. Make: Legrand, ABB, L &T, Schinder a) Four Pole 800 A 50 kA
Supplying and fixing of 400 A 4 Pole onload change over (COS) switch 4 poles, AC-23ADuty, 415V, 50Hz, AC Supply. (Open Execution) Make: Legrand, ABB, L &T, Schinder
Supplying, fixing 400 A rated 3 phases with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic /FRP/DMC insulator which are mounted on powder coated 40x6mm M.S. flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 400Amps 4×50×10mm Aluminium strips
Supplying, fixing 250 A rated 3 phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic /FRP/DMC insulator which are mounted on powder coated 40x6mm M.S. flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 250Amps 4×30×10mm Aluminium strips
Supplying, fixing 600 A rated 3 phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic /FRP/DMC insulator which are mounted on powder coated 40x6mm M.S. flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 600Amps 4×75×10mm Aluminium strips
Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.
Supplying, fixing and wiring 0 to 600V 96x96mm AC Voltmeter on existing panel/wood board
Supplying of multi-function digital meter with three-line backlight LCD type display for voltage, Current, frequency, Power, power factor, kVA, kWH, kVAR suitable for 3phase ,4wire LT network with IP54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy
Supplying & fixing 63 Amp TPN miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 63Amp TPN
Supplying and fixing 2mm thick perforated cable tray and cover with powder coated paint on MS support using necessary GI bolts/nuts and washer or welding, core cutting in all required areas/ floors.A) 150×50mm
Supplying and fixing 2mm thick perforated cable tray and cover with powder coated paint on MS support using necessary GI bolts/nuts and washer or welding, core cutting in all required areas/ floors. A) 300×50mm
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100Vgrade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010. A)2.5 Sq mm
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100Vgrade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010. A)4 Sq mm
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100Vgrade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010. A)10 Sq mm
Supplying and fixing angle iron frame work fabricated out of M.S. angle iron and M.S. Flat with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 50 x 50 x 6 mm
Supply and laying of following size double walled corrugated (DWC) HDPE pipe including all necessary connecting cockets /coupling /tees /bends/End caps of same materials in existing trench as Per IS 14930 part II suitable for drawing Underground cables. 120 mm OD/ 103 mm ID
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.06 MB
Tendernotice_2.pdf
PDF • 5.79 MB
BOQ_938116.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid