computer servers Computer Servers ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values Specification Form Factor Rack Rack
Tower Size (RU) 1 - Processor Make Intel Intel
AMD
SPARC Max. Number of sockets available on chipset 2 Max. Number of sockets populated with processor 2 Number of core per Processor 8 As per GeM Catalogue. Processor Configuration E5-2620 v4
8 core
2.10 GHz with 20 MB smart cache memory
85 watt As per GeM Catalogue. Chipset compatible with CPU INTEL C610 Series Chipset - Availability of Co- Processor No - If Yes Co-Processor Configuration NA Phi-7210
64 core
1.30 GHz with 32 MB L2 cache memory
215 watt
Phi-7210F
1.30 GHz with 32 1/5 MB L2 cache memory
230 watt
Phi-7230
Phi-7230F
Phi-7250
68 core
1.40 GHz with 34 MB L2 cache memory
Phi-7250F
Phi-7290
72 core
1.50 GHz with 36 MB L2 cache memory
245 watt
Phi-7290F
260 watt
NA PCI Slots (Express Gen 3.0) 3 - Type of RAM DDR4 - RAM Size (GB) 32 RAM upgradable upto (GB) 256 DIMM Slots (No.) 8 - Type of Hard Disk Drive SAS SAS
NL SAS
SSD
SATA Hard disk drive Capacity (GB) 600 Hard disk drive Speed (RPM) 15K - RAID Controller Cache (MB) 0 - RAID Type 5 - RAID Controller Ports @12 Gbps 2 - Video Controller (support VGA or above resolution) Yes - Keyboard No - Mouse No - Bays (min. 2 internal or more hot plug) 4 - USB Ports (version 2.0/3.0) 3 - Certifications
Yes - 2/5 Compliance support by Windows
Red Hat or Novell. DVD ROM (or better) 8x or better - Network Card Supported 1G - FC HBA Dual port card NA - FC HBA Dual port card Speed NA - Power Management - - Redundant Power Supply Yes - Redundant Fan Yes - Total No of Ports 2x1GbE - Declare SPEC int_rate_base 2006 & specfp_rate_2006 for 1
2
4
8 prcessor as applicable. - - Server scalability to be achieved within the box without adding nodes Yes - RoHS Compliance Yes - BIS Registration number & its Validity - - Max. power consumption of the system (Watt) 900 - Availability of Type test reports consisting of verification of all the features & functional parameters & environmental tests sequences as under: a Dry heat test (For 16 hrs at a temperature of 45 degree C in accordance with IS: 90 00/part-3/section-5/197 7) b Cold test(For 4 hrs at a temperature of 0 degree C in accordance with IS: 9000/part-2/sec tion-4/1977 c Damp Heat Cyclic Test ( For 2 cycles of 24 hrs at a temperature of 40 degree C & 95% RH in No - 3/5 accordance with IS: 90 00/part-5/section-1/198 1) Note:- The server shall be checked for all the parameters before conditioning
After completion of the above environmental tests sequence
with a recovery period of 1 to 2 hrs
the server shall be functional Name address of Lab - - Test Report No. date - - Power Supply 230 V +/-10%
50 Hz - On Site OEM Warranty (years) 3 1
3
5 * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Sreenivasa Rao Daggubati 462013
Post box 2
Shamla hills
Next to Regional College campus
Bhopal 1 15 Required No ePBG Required No